-
2
-
-
0026687889
-
An overview of minimally invasive technologies
-
Ginsberg B. H., "An overview of minimally invasive technologies," Clinical Chemistry, 38(9), 1596-1600 (1992).
-
(1992)
Clinical Chemistry
, vol.38
, Issue.9
, pp. 1596-1600
-
-
Ginsberg, B.H.1
-
3
-
-
3142547033
-
Reverse iontophoresis for non-invasive transdermal monitoring
-
DOI 10.1088/0967-3334/25/3/R01, PII S0967333404542739
-
Leboulanger B., Guy R. H. and Delgado-Charro M. B., "Reverse iontophoresis for non-invasive transdermal monitoring," Physiological Measurement, 26(3), R35-R50 (2004). (Pubitemid 38901997)
-
(2004)
Physiological Measurement
, vol.25
, Issue.3
-
-
Leboulanger, B.1
Guy, R.H.2
Delgado-Charro, M.B.3
-
4
-
-
0030111936
-
Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides
-
Pan S., Chung H., Arnold M. A. and Small G. W., "Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides," Anal. Chemistry, 68(7), 1124-1135 (1996). (Pubitemid 126681788)
-
(1996)
Analytical Chemistry
, vol.68
, Issue.7
, pp. 1124-1135
-
-
Pan, S.1
-
5
-
-
0026668743
-
Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation
-
Robinson M. R., Eaton R. P., Haaland D. M., Koepp G. W., Thomas E. V., Stallard B. R. and Robinson P. L., "Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation," Clin. Chem., 38(9), 1618-1622 (1992).
-
(1992)
Clin. Chem.
, vol.38
, Issue.9
, pp. 1618-1622
-
-
Robinson, M.R.1
Eaton, R.P.2
Haaland, D.M.3
Koepp, G.W.4
Thomas, E.V.5
Stallard, B.R.6
Robinson, P.L.7
-
6
-
-
0028731080
-
Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissue in the near-infrared
-
Maier J. S., Walker S. A., Fantini S., Franceschini M. A. and Gratton E., "Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissue in the near-infrared," Optics Lett., 19(24), 2062-2064 (1994).
-
(1994)
Optics Lett.
, vol.1
, Issue.24
, pp. 2062-2064
-
-
Maier, J.S.1
Walker, S.A.2
Fantini, S.3
Franceschini, M.A.4
Gratton, E.5
-
7
-
-
0026891886
-
Noninvasive optical polarimetric glucose sensing using a true phase measurement technique
-
DOI 10.1109/10.142650
-
Cote G. L., Fox M. D. and Nortrop R. B., "Noninvasive optical polarimetric glucose sensing using a true phase measurement technique," IEEE Transactions on biomedical engineering, 39(7), 752-756 (1992). (Pubitemid 23133305)
-
(1992)
IEEE Transactions on Biomedical Engineering
, vol.39
, Issue.7
, pp. 752-756
-
-
Cote, G.L.1
Fox, M.D.2
Northrop, R.B.3
-
8
-
-
0028493491
-
Multispectral polarimetric glucose detection using a single Pockels cell
-
King T.W., Cote G. L., McNichols R. and Goetz Jr. M. J., "Multispectral polarimetric glucose detection using a single Pockels cell," Optical Engineering, 33(8), 2746-2753 (1994).
-
(1994)
Optical Engineering
, vol.33
, Issue.8
, pp. 2746-2753
-
-
King, T.W.1
Cote, G.L.2
McNichols, R.3
Goetz Jr., M.J.4
-
9
-
-
0029329088
-
Application of a multivariate technique to Raman spectra for quantification of body chemicals
-
Goetz M. J., Cote G. L., March W. E., Erckens R. J. and Motamedi M., "Application of a multivariate technique to Raman spectra for quantification of body chemicals," IEEE Transactions on Biomedical Engineering, 42(7), 728-731 (1995).
-
(1995)
IEEE Transactions on Biomedical Engineering
, vol.42
, Issue.7
, pp. 728-731
-
-
Goetz, M.J.1
Cote, G.L.2
March, W.E.3
Erckens, R.J.4
Motamedi, M.5
-
10
-
-
0000876181
-
Rapid, noninvasive concentration measurements of aqueous biological analytes by near-infrared Raman spectroscopy
-
Berger A. J., Wang Y. and Feld M. S., "Rapid, noninvasive concentration measurements of aqueous biological analytes by near-infrared Raman spectroscopy," Appl. Opt., 35(12), 209-212 (1996). (Pubitemid 126590876)
-
(1996)
Applied Optics
, vol.35
, Issue.1
, pp. 209-212
-
-
Berger, A.J.1
Wang, Y.2
Feld, M.S.3
-
11
-
-
0033081688
-
Glucose sensor for low-cost lifetime-based sensing using a genetically engineered protein
-
DOI 10.1006/abio.1998.2974
-
Tolosa L., Gryczynskj J., Eichhorn L. R., Dartelbaum J. D., Castellano F. N., Rao G. and Lakowicz J. R., "Glucose sensor for low-cost lifetime-based sensing using a genetically engineered protein," Anal. Biochem., 267, 114-120,(1999). (Pubitemid 29061813)
-
(1999)
Analytical Biochemistry
, vol.267
, Issue.1
, pp. 114-120
-
-
Tolosa, L.1
Gryczynski, I.2
Eichhorn, L.R.3
Dattelbaum, J.D.4
Castellano, F.N.5
Rao, G.6
Lakowicz, J.R.7
-
12
-
-
0032799808
-
A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel
-
DOI 10.1021/ac990060r
-
Russell R. J., Pishko M. V., Gefrides C. C., McShane M. J. and Cote G. L., "A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel," Anal. Chem. 71(15), 3126-3132 (1999). (Pubitemid 29372728)
-
(1999)
Analytical Chemistry
, vol.71
, Issue.15
, pp. 3126-3132
-
-
Russell, R.J.1
Pishko, M.V.2
Gefrides, C.C.3
McShane, M.J.4
Cote, G.L.5
-
13
-
-
0038628894
-
Noninvasive blood glucose monitoring with optical coherence tomography: A pilot study in human subjects
-
DOI 10.2337/diacare.25.12.2263
-
Larin K. V., Motamedi M., Eledrisi M. S. and Esenaliev R. O., "Noninvasive blood glucose monitoring with optical coherence tomography, a pilot study in human subjects," Diabetes Care, 25, 2263-2267 (2002). (Pubitemid 41071038)
-
(2002)
Diabetes Care
, vol.25
, Issue.12
, pp. 2263-2267
-
-
Larin, K.V.1
Eledrisi, M.S.2
Motamedi, M.3
Esenaliev, R.O.4
-
14
-
-
0038119770
-
Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: A pilot study
-
DOI 10.1088/0031-9155/48/10/310, PII S0031915503587954
-
Larin K. V., Motamedi M., Ashitkov T. V. and Esenaliev R. O., "Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study," Physics in Medicine and Biology, 48(10), 1371-1390 (2003). (Pubitemid 36700471)
-
(2003)
Physics in Medicine and Biology
, vol.48
, Issue.10
, pp. 1371-1390
-
-
Larin, K.V.1
Motamedi, M.2
Ashitkov, T.V.3
Esenaliev, R.O.4
-
15
-
-
0033716459
-
Glucose monitoring in vivo by measuring laser-induced acoustic profiles
-
Bednov A., Karabutov A., Savateeva E., March W. and Oraevsky A, "Glucose monitoring in vivo by measuring laser-induced acoustic profiles," Proceedings of SPIE, 3916, 9-18, (2000).
-
(2000)
Proceedings of SPIE
, vol.3916
, pp. 9-18
-
-
Bednov, A.1
Karabutov, A.2
Savateeva, E.3
March, W.4
Oraevsky A5
-
16
-
-
85165634569
-
Reagentless near JR determination of glucose in whole blood using multivariate calibration
-
Haaland D. M., Robinson M. R., Koepp G. W., Thomas E. V. and Eaton R. P., "Reagentless near JR determination of glucose in whole blood using multivariate calibration", Appl. Spectr., 46(10), 1 575-1 578 (1992).
-
(1992)
Appl. Spectr.
, vol.46
, Issue.10
, pp. 578
-
-
Haaland, D.M.1
Robinson, M.R.2
Koepp, G.W.3
Thomas, E.V.4
Eaton, R.P.5
-
17
-
-
0030073462
-
Simultaneous measurements of glucose, glutamine, ammonia, lactate, and glutamate in aqueous solutions by near-infrared spectroscopy
-
Chung H., Arnold M. A., Rhiel M., and Murhammer D. W., "Simultaneous measurements of glucose, glutamine, ammonia, lactate and glutamate in aqueous solutions by near JR spectroscopy," Appl. Spectr., 50(2), 270-276, (1996). (Pubitemid 126620524)
-
(1996)
Applied Spectroscopy
, vol.50
, Issue.2
, pp. 270-276
-
-
Chung, H.1
Arnold, M.A.2
Rhiel, M.3
Murhammer, D.W.4
-
18
-
-
0032141573
-
Near-infrared spectroscopy for determination of glucose, lactate, and ammonia in cell culture media
-
McShane M. J. and Cote G. L., "Near infrared spectroscopy for determination of glucose, lactate, and ammonia in cell culture media," Appl. Spectr., 52(8), 1073-1078 (1998). (Pubitemid 128603975)
-
(1998)
Applied Spectroscopy
, vol.52
, Issue.8
, pp. 1073-1078
-
-
McShane, M.J.1
Cote, G.L.2
-
19
-
-
33846561537
-
High antinoise photoacoustic tomography based on a modified filtered backprojection algorithm with combination wavelet
-
DOI 10.1118/1.2426406
-
Zeng L. M., Xing D., Gu H. M., Yang D.W., Yang S. H. and Xiang L. Z., "High antinoise photoacoustic tomography based on a modified filtered backprojection algorithm with combination wavelet," Med. Phys., 34(2), 556-563 (2007). (Pubitemid 46185135)
-
(2007)
Medical Physics
, vol.34
, Issue.2
, pp. 556-563
-
-
Zeng, L.1
Xing, D.2
Gu, H.3
Yang, D.4
Yang, S.5
Xiang, L.6
-
20
-
-
50049108205
-
Design of High-Resolution Photoacoustic Imaging System Based on LabVIEW Station
-
Zeng L. M., Liu G. D., Ren Z., Huang Z. And Shao B. L., "Design of High-Resolution Photoacoustic Imaging System Based on LabVIEW Station," Acta Photonica Sinica, 37(7), 1436-1440 (2008).
-
(2008)
Acta Photonica Sinica
, vol.37
, Issue.7
, pp. 1436-1440
-
-
Zeng, L.M.1
Liu, G.D.2
Ren, Z.3
Huang, Z.4
Shao, B.L.5
-
21
-
-
0038391518
-
Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain
-
DOI 10.1038/nbt839
-
Wang X. D., Pang Y. J., Ku G., Xie X. Y., Stoica G. and Wang L. H., "Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain," Nature Biotechnology, 21(7), 803-806 (2003). (Pubitemid 36791400)
-
(2003)
Nature Biotechnology
, vol.21
, Issue.7
, pp. 803-806
-
-
Wang, X.1
Pang, Y.2
Ku, G.3
Xie, X.4
Stoica, G.5
Wang, L.V.6
-
22
-
-
33646421952
-
Fast microwave-induced thermoacoustic tomography based on multi-element phase-controlled focus technique
-
Zeng L. M., Xing D., Gu H. M., Yang D.W., Yang S. H. and Xiang L. Z., "Fast microwave-induced thermoacoustic tomography based on multi-element phase-controlled focus technique," Chin. Phys. Lett., 23(5), 1215-1218 (2006).
-
(2006)
Chin. Phys. Lett.
, vol.23
, Issue.5
, pp. 1215-1218
-
-
Zeng, L.M.1
Xing, D.2
Gu, H.M.3
Yang, D.W.4
Yang, S.H.5
Xiang, L.Z.6
-
23
-
-
50949116086
-
Image reconstruction of high-quality photoacoustic tomography using wavelet-analysis-based algorithm
-
Zeng L. M., Liu G. D., Shao B. L., Ren Z. and Huang Z., "Image reconstruction of high-quality photoacoustic tomography using wavelet-analysis-based algorithm," Proc. IEEE ICBBE, 2565-2570 (2008).
-
(2008)
Proc. IEEE ICBBE
, pp. 2565-2570
-
-
Zeng, L.M.1
Liu, G.D.2
Shao, B.L.3
Ren, Z.4
Huang, Z.5
-
24
-
-
0030393889
-
Time-resolved laser optoacoustic tomography of inhomogeneous media
-
Karabutov A. A., Podymova N. B., Letokhov V. S., "Time-resolved laser optoacoustic tomography of inhomogeneous media," Appl. Phys. B, 63, 545-563 (1996).
-
(1996)
Appl. Phys. B
, vol.63
, pp. 545-563
-
-
Karabutov, A.A.1
Podymova, N.B.2
Letokhov, V.S.3
-
25
-
-
0027754155
-
Glucose determination by a pulsed photoacoustic technique using a gelatin based phantom
-
Quan K. M., Christison G. B., MacKenzie H. A. and Hodgson P., "Glucose determination by a pulsed photoacoustic technique using a gelatin based phantom," Phys Med Biol, 38(12), 1911-1922 (1993).
-
(1993)
Phys Med Biol
, vol.38
, Issue.12
, pp. 1911-1922
-
-
Quan, K.M.1
Christison, G.B.2
MacKenzie, H.A.3
Hodgson, P.4
-
26
-
-
85136319628
-
Blood glucose measurements by photoacoustics
-
MacKenzie H. A., Ashton H. S., Shen Y. C., Lindberg J., Rae P., Quan K. M. and Spiers S., "Blood glucose measurements by photoacoustics," OSA TOPS, 22,156-159 (1998).
-
(1998)
OSA TOPS
, vol.22
, pp. 156-159
-
-
MacKenzie, H.A.1
Ashton, H.S.2
Shen, Y.C.3
Lindberg, J.4
Rae, P.5
Quan, K.M.6
Spiers, S.7
-
27
-
-
33847225922
-
Noninvasive continuous glucose monitoring using photoacoustic technology - Results from the first 62 subjects
-
DOI 10.1089/dia.2006.0059
-
Weiss R., Yegorchikov Y., Shusterman A. and Raz I., "Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects," Diabetes Technol Ther, 9(1), 68-74 (2007). (Pubitemid 46309709)
-
(2007)
Diabetes Technology and Therapeutics
, vol.9
, Issue.1
, pp. 68-74
-
-
Weiss, R.1
Yegorchikov, Y.2
Shusterman, A.3
Raz, I.4
|