메뉴 건너뛰기




Volumn 7280, Issue , 2009, Pages

Design of a portable noninvasive photoacoustic glucose monitoring system integrated laser diode excitation with annular array detection

Author keywords

Annular array; Blood glucose; Laser diode; Photoacoustic

Indexed keywords

1550 NM; ACCURATE LOCATION; ANNULAR ARRAY; ANNULAR ARRAY TRANSDUCERS; BACKWARD MODES; BLOOD GLUCOSE; DESIGN METHOD; DIABETES MELLITUS; DUAL-WAVELENGTH; FOCUSING ALGORITHM; GLUCOSE MONITORING SYSTEM; HIGH SIGNAL-TO-NOISE RATIO; HOLLOW STRUCTURE; INTEGRATED LASER DIODES; LASER DIODE; LASER DIODES; LASER SOURCES; NEAR INFRARED; NONIVASIVE; OPTICAL PULSE ENERGY; PHOTOACOUSTIC; PHOTOACOUSTIC SIGNALS; PULSED LASER DIODES;

EID: 65949104285     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.822563     Document Type: Conference Paper
Times cited : (13)

References (27)
  • 2
    • 0026687889 scopus 로고
    • An overview of minimally invasive technologies
    • Ginsberg B. H., "An overview of minimally invasive technologies," Clinical Chemistry, 38(9), 1596-1600 (1992).
    • (1992) Clinical Chemistry , vol.38 , Issue.9 , pp. 1596-1600
    • Ginsberg, B.H.1
  • 3
    • 3142547033 scopus 로고    scopus 로고
    • Reverse iontophoresis for non-invasive transdermal monitoring
    • DOI 10.1088/0967-3334/25/3/R01, PII S0967333404542739
    • Leboulanger B., Guy R. H. and Delgado-Charro M. B., "Reverse iontophoresis for non-invasive transdermal monitoring," Physiological Measurement, 26(3), R35-R50 (2004). (Pubitemid 38901997)
    • (2004) Physiological Measurement , vol.25 , Issue.3
    • Leboulanger, B.1    Guy, R.H.2    Delgado-Charro, M.B.3
  • 4
    • 0030111936 scopus 로고    scopus 로고
    • Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides
    • Pan S., Chung H., Arnold M. A. and Small G. W., "Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides," Anal. Chemistry, 68(7), 1124-1135 (1996). (Pubitemid 126681788)
    • (1996) Analytical Chemistry , vol.68 , Issue.7 , pp. 1124-1135
    • Pan, S.1
  • 6
    • 0028731080 scopus 로고
    • Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissue in the near-infrared
    • Maier J. S., Walker S. A., Fantini S., Franceschini M. A. and Gratton E., "Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissue in the near-infrared," Optics Lett., 19(24), 2062-2064 (1994).
    • (1994) Optics Lett. , vol.1 , Issue.24 , pp. 2062-2064
    • Maier, J.S.1    Walker, S.A.2    Fantini, S.3    Franceschini, M.A.4    Gratton, E.5
  • 7
    • 0026891886 scopus 로고
    • Noninvasive optical polarimetric glucose sensing using a true phase measurement technique
    • DOI 10.1109/10.142650
    • Cote G. L., Fox M. D. and Nortrop R. B., "Noninvasive optical polarimetric glucose sensing using a true phase measurement technique," IEEE Transactions on biomedical engineering, 39(7), 752-756 (1992). (Pubitemid 23133305)
    • (1992) IEEE Transactions on Biomedical Engineering , vol.39 , Issue.7 , pp. 752-756
    • Cote, G.L.1    Fox, M.D.2    Northrop, R.B.3
  • 8
    • 0028493491 scopus 로고
    • Multispectral polarimetric glucose detection using a single Pockels cell
    • King T.W., Cote G. L., McNichols R. and Goetz Jr. M. J., "Multispectral polarimetric glucose detection using a single Pockels cell," Optical Engineering, 33(8), 2746-2753 (1994).
    • (1994) Optical Engineering , vol.33 , Issue.8 , pp. 2746-2753
    • King, T.W.1    Cote, G.L.2    McNichols, R.3    Goetz Jr., M.J.4
  • 10
    • 0000876181 scopus 로고    scopus 로고
    • Rapid, noninvasive concentration measurements of aqueous biological analytes by near-infrared Raman spectroscopy
    • Berger A. J., Wang Y. and Feld M. S., "Rapid, noninvasive concentration measurements of aqueous biological analytes by near-infrared Raman spectroscopy," Appl. Opt., 35(12), 209-212 (1996). (Pubitemid 126590876)
    • (1996) Applied Optics , vol.35 , Issue.1 , pp. 209-212
    • Berger, A.J.1    Wang, Y.2    Feld, M.S.3
  • 12
    • 0032799808 scopus 로고    scopus 로고
    • A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel
    • DOI 10.1021/ac990060r
    • Russell R. J., Pishko M. V., Gefrides C. C., McShane M. J. and Cote G. L., "A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel," Anal. Chem. 71(15), 3126-3132 (1999). (Pubitemid 29372728)
    • (1999) Analytical Chemistry , vol.71 , Issue.15 , pp. 3126-3132
    • Russell, R.J.1    Pishko, M.V.2    Gefrides, C.C.3    McShane, M.J.4    Cote, G.L.5
  • 13
    • 0038628894 scopus 로고    scopus 로고
    • Noninvasive blood glucose monitoring with optical coherence tomography: A pilot study in human subjects
    • DOI 10.2337/diacare.25.12.2263
    • Larin K. V., Motamedi M., Eledrisi M. S. and Esenaliev R. O., "Noninvasive blood glucose monitoring with optical coherence tomography, a pilot study in human subjects," Diabetes Care, 25, 2263-2267 (2002). (Pubitemid 41071038)
    • (2002) Diabetes Care , vol.25 , Issue.12 , pp. 2263-2267
    • Larin, K.V.1    Eledrisi, M.S.2    Motamedi, M.3    Esenaliev, R.O.4
  • 14
    • 0038119770 scopus 로고    scopus 로고
    • Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: A pilot study
    • DOI 10.1088/0031-9155/48/10/310, PII S0031915503587954
    • Larin K. V., Motamedi M., Ashitkov T. V. and Esenaliev R. O., "Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study," Physics in Medicine and Biology, 48(10), 1371-1390 (2003). (Pubitemid 36700471)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.10 , pp. 1371-1390
    • Larin, K.V.1    Motamedi, M.2    Ashitkov, T.V.3    Esenaliev, R.O.4
  • 15
  • 16
    • 85165634569 scopus 로고
    • Reagentless near JR determination of glucose in whole blood using multivariate calibration
    • Haaland D. M., Robinson M. R., Koepp G. W., Thomas E. V. and Eaton R. P., "Reagentless near JR determination of glucose in whole blood using multivariate calibration", Appl. Spectr., 46(10), 1 575-1 578 (1992).
    • (1992) Appl. Spectr. , vol.46 , Issue.10 , pp. 578
    • Haaland, D.M.1    Robinson, M.R.2    Koepp, G.W.3    Thomas, E.V.4    Eaton, R.P.5
  • 17
    • 0030073462 scopus 로고    scopus 로고
    • Simultaneous measurements of glucose, glutamine, ammonia, lactate, and glutamate in aqueous solutions by near-infrared spectroscopy
    • Chung H., Arnold M. A., Rhiel M., and Murhammer D. W., "Simultaneous measurements of glucose, glutamine, ammonia, lactate and glutamate in aqueous solutions by near JR spectroscopy," Appl. Spectr., 50(2), 270-276, (1996). (Pubitemid 126620524)
    • (1996) Applied Spectroscopy , vol.50 , Issue.2 , pp. 270-276
    • Chung, H.1    Arnold, M.A.2    Rhiel, M.3    Murhammer, D.W.4
  • 18
    • 0032141573 scopus 로고    scopus 로고
    • Near-infrared spectroscopy for determination of glucose, lactate, and ammonia in cell culture media
    • McShane M. J. and Cote G. L., "Near infrared spectroscopy for determination of glucose, lactate, and ammonia in cell culture media," Appl. Spectr., 52(8), 1073-1078 (1998). (Pubitemid 128603975)
    • (1998) Applied Spectroscopy , vol.52 , Issue.8 , pp. 1073-1078
    • McShane, M.J.1    Cote, G.L.2
  • 19
    • 33846561537 scopus 로고    scopus 로고
    • High antinoise photoacoustic tomography based on a modified filtered backprojection algorithm with combination wavelet
    • DOI 10.1118/1.2426406
    • Zeng L. M., Xing D., Gu H. M., Yang D.W., Yang S. H. and Xiang L. Z., "High antinoise photoacoustic tomography based on a modified filtered backprojection algorithm with combination wavelet," Med. Phys., 34(2), 556-563 (2007). (Pubitemid 46185135)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 556-563
    • Zeng, L.1    Xing, D.2    Gu, H.3    Yang, D.4    Yang, S.5    Xiang, L.6
  • 20
    • 50049108205 scopus 로고    scopus 로고
    • Design of High-Resolution Photoacoustic Imaging System Based on LabVIEW Station
    • Zeng L. M., Liu G. D., Ren Z., Huang Z. And Shao B. L., "Design of High-Resolution Photoacoustic Imaging System Based on LabVIEW Station," Acta Photonica Sinica, 37(7), 1436-1440 (2008).
    • (2008) Acta Photonica Sinica , vol.37 , Issue.7 , pp. 1436-1440
    • Zeng, L.M.1    Liu, G.D.2    Ren, Z.3    Huang, Z.4    Shao, B.L.5
  • 21
    • 0038391518 scopus 로고    scopus 로고
    • Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain
    • DOI 10.1038/nbt839
    • Wang X. D., Pang Y. J., Ku G., Xie X. Y., Stoica G. and Wang L. H., "Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain," Nature Biotechnology, 21(7), 803-806 (2003). (Pubitemid 36791400)
    • (2003) Nature Biotechnology , vol.21 , Issue.7 , pp. 803-806
    • Wang, X.1    Pang, Y.2    Ku, G.3    Xie, X.4    Stoica, G.5    Wang, L.V.6
  • 22
    • 33646421952 scopus 로고    scopus 로고
    • Fast microwave-induced thermoacoustic tomography based on multi-element phase-controlled focus technique
    • Zeng L. M., Xing D., Gu H. M., Yang D.W., Yang S. H. and Xiang L. Z., "Fast microwave-induced thermoacoustic tomography based on multi-element phase-controlled focus technique," Chin. Phys. Lett., 23(5), 1215-1218 (2006).
    • (2006) Chin. Phys. Lett. , vol.23 , Issue.5 , pp. 1215-1218
    • Zeng, L.M.1    Xing, D.2    Gu, H.M.3    Yang, D.W.4    Yang, S.H.5    Xiang, L.Z.6
  • 23
    • 50949116086 scopus 로고    scopus 로고
    • Image reconstruction of high-quality photoacoustic tomography using wavelet-analysis-based algorithm
    • Zeng L. M., Liu G. D., Shao B. L., Ren Z. and Huang Z., "Image reconstruction of high-quality photoacoustic tomography using wavelet-analysis-based algorithm," Proc. IEEE ICBBE, 2565-2570 (2008).
    • (2008) Proc. IEEE ICBBE , pp. 2565-2570
    • Zeng, L.M.1    Liu, G.D.2    Shao, B.L.3    Ren, Z.4    Huang, Z.5
  • 24
    • 0030393889 scopus 로고    scopus 로고
    • Time-resolved laser optoacoustic tomography of inhomogeneous media
    • Karabutov A. A., Podymova N. B., Letokhov V. S., "Time-resolved laser optoacoustic tomography of inhomogeneous media," Appl. Phys. B, 63, 545-563 (1996).
    • (1996) Appl. Phys. B , vol.63 , pp. 545-563
    • Karabutov, A.A.1    Podymova, N.B.2    Letokhov, V.S.3
  • 25
    • 0027754155 scopus 로고
    • Glucose determination by a pulsed photoacoustic technique using a gelatin based phantom
    • Quan K. M., Christison G. B., MacKenzie H. A. and Hodgson P., "Glucose determination by a pulsed photoacoustic technique using a gelatin based phantom," Phys Med Biol, 38(12), 1911-1922 (1993).
    • (1993) Phys Med Biol , vol.38 , Issue.12 , pp. 1911-1922
    • Quan, K.M.1    Christison, G.B.2    MacKenzie, H.A.3    Hodgson, P.4
  • 27
    • 33847225922 scopus 로고    scopus 로고
    • Noninvasive continuous glucose monitoring using photoacoustic technology - Results from the first 62 subjects
    • DOI 10.1089/dia.2006.0059
    • Weiss R., Yegorchikov Y., Shusterman A. and Raz I., "Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects," Diabetes Technol Ther, 9(1), 68-74 (2007). (Pubitemid 46309709)
    • (2007) Diabetes Technology and Therapeutics , vol.9 , Issue.1 , pp. 68-74
    • Weiss, R.1    Yegorchikov, Y.2    Shusterman, A.3    Raz, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.