메뉴 건너뛰기




Volumn 95, Issue 4 SUPPL., 2009, Pages 27-34

Friction couples in total hip replacement

Author keywords

[No Author keywords available]

Indexed keywords

POLYETHYLENE;

EID: 65749085730     PISSN: 18770568     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.otsr.2009.04.003     Document Type: Review
Times cited : (14)

References (54)
  • 1
    • 0030726206 scopus 로고    scopus 로고
    • The long term results of Charnley low-friction arthroplasty in young patients who have congenital dislocation, degenerative osteoarthrosis or rheumatoid arthritis
    • Sochart D.H., and Porter M. The long term results of Charnley low-friction arthroplasty in young patients who have congenital dislocation, degenerative osteoarthrosis or rheumatoid arthritis. J. Bone Joint Surg Am 79 (1997) 1599-1617
    • (1997) J. Bone Joint Surg Am , vol.79 , pp. 1599-1617
    • Sochart, D.H.1    Porter, M.2
  • 2
    • 65749084912 scopus 로고    scopus 로고
    • o 62. Paris. Expansion scientifique publications : 1997. p. 53-69.
    • o 62. Paris. Expansion scientifique publications : 1997. p. 53-69.
  • 3
    • 0036023527 scopus 로고    scopus 로고
    • A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    • Dumbleton J.H., Manley M.T., and Edidin A. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17 (2002) 649-661
    • (2002) J Arthroplasty , vol.17 , pp. 649-661
    • Dumbleton, J.H.1    Manley, M.T.2    Edidin, A.3
  • 4
    • 0344927558 scopus 로고    scopus 로고
    • Assessment of polyethylene wear in total hip replacement
    • Devane P.A., and Horne J.G. Assessment of polyethylene wear in total hip replacement. Clin Orthop 369 (1999) 59-72
    • (1999) Clin Orthop , vol.369 , pp. 59-72
    • Devane, P.A.1    Horne, J.G.2
  • 5
    • 26844522305 scopus 로고    scopus 로고
    • The acetabular insert-metal backing interface
    • Wasielewski R.C., Jacobs J.J., et al. The acetabular insert-metal backing interface. J Arthroplasty 20 (2005) 914-922
    • (2005) J Arthroplasty , vol.20 , pp. 914-922
    • Wasielewski, R.C.1    Jacobs, J.J.2
  • 6
    • 0027407506 scopus 로고
    • Amstutz HC: In vivo wear of polyethylene acetabular components
    • Kabo J.M., Gebhard J.S., and Loren G. Amstutz HC: In vivo wear of polyethylene acetabular components. J Bone Joint Surg Br 75 (1993) 254-258
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 254-258
    • Kabo, J.M.1    Gebhard, J.S.2    Loren, G.3
  • 7
    • 65749095216 scopus 로고    scopus 로고
    • o 78. p. 63-96.
    • o 78. p. 63-96.
  • 8
    • 65749092088 scopus 로고    scopus 로고
    • Malchau D, Gower A, et al. Prognosis of total hip replacement update and validation of results from the Swedish national hip arthroplasty registry 1979-1998. Scientific exhibition presented at the 67th Annual Meeting of the AAOS, Orlando, USA. March 15-19. 2000. p. 1-16.
    • Malchau D, Gower A, et al. Prognosis of total hip replacement update and validation of results from the Swedish national hip arthroplasty registry 1979-1998. Scientific exhibition presented at the 67th Annual Meeting of the AAOS, Orlando, USA. March 15-19. 2000. p. 1-16.
  • 9
    • 33645879240 scopus 로고    scopus 로고
    • Analyse de surface après explantation de 40 cupules retentives en polyéthylène à double mobilité
    • Adam P., Farizon F., and Fessy M.H. Analyse de surface après explantation de 40 cupules retentives en polyéthylène à double mobilité. Rev Chir Orthop 91 (2005) 627-636
    • (2005) Rev Chir Orthop , vol.91 , pp. 627-636
    • Adam, P.1    Farizon, F.2    Fessy, M.H.3
  • 10
    • 65749111318 scopus 로고    scopus 로고
    • Wear of bipolar hip prostheses
    • Kusaba A., and Kuroki Y. Wear of bipolar hip prostheses. J Arthroplasty 11 (1998) 602-608
    • (1998) J Arthroplasty , vol.11 , pp. 602-608
    • Kusaba, A.1    Kuroki, Y.2
  • 11
    • 39849084088 scopus 로고    scopus 로고
    • Étude d'une série de 438 cupules non cimentées à double mobilité
    • Philipot R., Farizon F., Camilleri J.P., et al. Étude d'une série de 438 cupules non cimentées à double mobilité. Rev Chir Orthop 94 (2008) 43-48
    • (2008) Rev Chir Orthop , vol.94 , pp. 43-48
    • Philipot, R.1    Farizon, F.2    Camilleri, J.P.3
  • 12
    • 39849108058 scopus 로고    scopus 로고
    • Résultat à 5 ans de la cupule double mobilité evora
    • Leclerc S., Benoit J.Y., de Rosa J.P., et al. Résultat à 5 ans de la cupule double mobilité evora. Rev Chir Orthop 94 (2008) 37-42
    • (2008) Rev Chir Orthop , vol.94 , pp. 37-42
    • Leclerc, S.1    Benoit, J.Y.2    de Rosa, J.P.3
  • 14
    • 0033814067 scopus 로고    scopus 로고
    • Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
    • Nevelos J., Ingham E., Doyle C., et al. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J. Arthroplasty 15 (2000) 793-795
    • (2000) J. Arthroplasty , vol.15 , pp. 793-795
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3
  • 15
    • 0029902177 scopus 로고    scopus 로고
    • Ceramic femoral head fractures in total hip arthroplasty
    • Fritsh E.W., and Gleitz M. Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop Del Res 328 (1996) 129-134
    • (1996) Clin Orthop Del Res , vol.328 , pp. 129-134
    • Fritsh, E.W.1    Gleitz M2
  • 16
    • 0031940455 scopus 로고    scopus 로고
    • Ceramics for total hip replacement; what a surgeon should know
    • Willmann G. Ceramics for total hip replacement; what a surgeon should know. Orthopedics 21 (1998) 173-177
    • (1998) Orthopedics , vol.21 , pp. 173-177
    • Willmann, G.1
  • 17
    • 0033814112 scopus 로고    scopus 로고
    • An in vivo determination of total hip arthroplasty pistoning during activity
    • Lombardi A.V., Mallory T.H., Denis D.A., et al. An in vivo determination of total hip arthroplasty pistoning during activity. J Arthroplasty 15 (2000) 702-709
    • (2000) J Arthroplasty , vol.15 , pp. 702-709
    • Lombardi, A.V.1    Mallory, T.H.2    Denis, D.A.3
  • 18
    • 34249933860 scopus 로고    scopus 로고
    • Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation
    • Walker W.L., O'Toole G.C., Walter W.K., et al. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty 22 (2007) 496-503
    • (2007) J Arthroplasty , vol.22 , pp. 496-503
    • Walker, W.L.1    O'Toole, G.C.2    Walter, W.K.3
  • 19
    • 0041419860 scopus 로고    scopus 로고
    • Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup
    • Hasegawa M., Sudo A., Hirata H., et al. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup. J Arthroplasty 18 (2003) 658-661
    • (2003) J Arthroplasty , vol.18 , pp. 658-661
    • Hasegawa, M.1    Sudo, A.2    Hirata, H.3
  • 20
    • 21444450339 scopus 로고    scopus 로고
    • Early osteolysis following second generation metal-on-metal replacement
    • Park Y.S., Moon Y.W., Lim S.J., et al. Early osteolysis following second generation metal-on-metal replacement. J Bone Joint Surg Am 87 (2005) 1515-1521
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1515-1521
    • Park, Y.S.1    Moon, Y.W.2    Lim, S.J.3
  • 21
    • 23044447438 scopus 로고    scopus 로고
    • Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement: a prospective randomised study
    • Kim V.H. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement: a prospective randomised study. J Bone Joint Surg Am 87 (2005) 1769-1776
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1769-1776
    • Kim, V.H.1
  • 22
    • 0038441585 scopus 로고    scopus 로고
    • Zirconia and alumina ceramics in comparison with stainless steel heads. PE wear after a minimum 10 years follow-up
    • Hernigou Ph, and Bahrami I. Zirconia and alumina ceramics in comparison with stainless steel heads. PE wear after a minimum 10 years follow-up. J. Bone Joint Surg 85 B (2003) 504-509
    • (2003) J. Bone Joint Surg , vol.85 B , pp. 504-509
    • Hernigou Ph1    Bahrami, I.2
  • 23
    • 0000398086 scopus 로고
    • Friction, lubrification and wear of cobalt-chromium, alumina and zirconia hip prosthesis compared on a joint simulator
    • Feb. 17-20. Washington DC
    • McKellop H, Lu B, Benyal P. Friction, lubrification and wear of cobalt-chromium, alumina and zirconia hip prosthesis compared on a joint simulator. Annual Meeting of the Orthopaedics Research Society. 1992. Feb. 17-20. Washington DC.
    • (1992) Annual Meeting of the Orthopaedics Research Society
    • McKellop, H.1    Lu, B.2    Benyal, P.3
  • 24
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running measured in two patients
    • Bergmann G., Gratchen F., et al. Hip joint loading during walking and running measured in two patients. J Biomech 26 (1993) 969-990
    • (1993) J Biomech , vol.26 , pp. 969-990
    • Bergmann, G.1    Gratchen, F.2
  • 25
    • 10744222195 scopus 로고    scopus 로고
    • Current status of zirconia used in total hip implants
    • Clarke I.-C., Manaka M., Green D.D., et al. Current status of zirconia used in total hip implants. J Bone Joint Surg Am 85 Suppl. 4 (2003) 73-84
    • (2003) J Bone Joint Surg Am , vol.85 , Issue.SUPPL. 4 , pp. 73-84
    • Clarke, I.-C.1    Manaka, M.2    Green, D.D.3
  • 26
    • 0037657959 scopus 로고    scopus 로고
    • Revision total hip arthroplasty performed after fracture of a ceramic femoral head
    • Allain J., Roudot-Thoraval F., Delécrin J., et al. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. J Bone Joint Surg 85 A (2003) 825-830
    • (2003) J Bone Joint Surg , vol.85 A , pp. 825-830
    • Allain, J.1    Roudot-Thoraval, F.2    Delécrin, J.3
  • 28
    • 0022481953 scopus 로고
    • The Mc Kee-Farrar hip arthroplasty: a long-term study
    • August A.C., Aldam C.H., and Pynsent P.B. The Mc Kee-Farrar hip arthroplasty: a long-term study. J Bone Joint Surg 68-B (1986) 520-527
    • (1986) J Bone Joint Surg , vol.68 -B , pp. 520-527
    • August, A.C.1    Aldam, C.H.2    Pynsent, P.B.3
  • 29
    • 33744808260 scopus 로고    scopus 로고
    • Metallosis after contemporary metal-on-metal total hip arthroplasty: five to nine year follow-up
    • Korovessis P., Petsinis G., and Repanti M. Metallosis after contemporary metal-on-metal total hip arthroplasty: five to nine year follow-up. J. Bone Joint Surg 88 B (2006) 1183-1191
    • (2006) J. Bone Joint Surg , vol.88 B , pp. 1183-1191
    • Korovessis, P.1    Petsinis, G.2    Repanti, M.3
  • 30
    • 34249824258 scopus 로고    scopus 로고
    • TM polyéthylène cimentées : résultats préliminaires des cupules de Muller
    • TM polyéthylène cimentées : résultats préliminaires des cupules de Muller. Rev Chir Orthop 93 (2007) 302-304
    • (2007) Rev Chir Orthop , vol.93 , pp. 302-304
    • Augereau, B.1    Levaï, J.P.2    Nick, C.3    Boisgard, S.4
  • 31
    • 9644273922 scopus 로고    scopus 로고
    • Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty
    • Ladon D., Doherty A., Newson R., et al. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty 19 (2004) 78-83
    • (2004) J Arthroplasty , vol.19 , pp. 78-83
    • Ladon, D.1    Doherty, A.2    Newson, R.3
  • 32
    • 0034999690 scopus 로고    scopus 로고
    • The risk of cancer following total hip or knee arthroplasty
    • Tharami R., Dorey F.J., and Schmalzried T.P. The risk of cancer following total hip or knee arthroplasty. J. Bone Joint Surg 83 A (2001) 774-780
    • (2001) J. Bone Joint Surg , vol.83 A , pp. 774-780
    • Tharami, R.1    Dorey, F.J.2    Schmalzried, T.P.3
  • 33
    • 33646039225 scopus 로고    scopus 로고
    • Malignant tumors at the site of total hip prothesis: analysis review of 46 cases
    • Visuri T., Pulkkinen P., and Paavolainen P. Malignant tumors at the site of total hip prothesis: analysis review of 46 cases. J Arthroplasty 21 (2006) 311-323
    • (2006) J Arthroplasty , vol.21 , pp. 311-323
    • Visuri, T.1    Pulkkinen, P.2    Paavolainen, P.3
  • 34
    • 11844305550 scopus 로고    scopus 로고
    • An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements
    • Davies A.P., Willert H.G., et al. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg 87A (2005) 18-27
    • (2005) J Bone Joint Surg , vol.87 A , pp. 18-27
    • Davies, A.P.1    Willert, H.G.2
  • 35
    • 11844293972 scopus 로고    scopus 로고
    • Metal-on-metal beating and hypersensitivity in patients with artificial hip joints: a clinical and histological study
    • Willert H.G., Buchhorm G., et al. Metal-on-metal beating and hypersensitivity in patients with artificial hip joints: a clinical and histological study. J Bone Joint Surg 87A (2005) 28-36
    • (2005) J Bone Joint Surg , vol.87 A , pp. 28-36
    • Willert, H.G.1    Buchhorm, G.2
  • 36
    • 65749115286 scopus 로고    scopus 로고
    • MacMinn D, Daniel C. Passage trans-placentaire du chrome et du cobalt associé au couple de frottement metal-métal. Communication au congrès AAOS 2006 Chicago.
    • MacMinn D, Daniel C. Passage trans-placentaire du chrome et du cobalt associé au couple de frottement metal-métal. Communication au congrès AAOS 2006 Chicago.
  • 37
    • 9644257169 scopus 로고    scopus 로고
    • Large versus small femoral heads in metal on metal hip arthroplasty
    • Cuckler J., Moore K., Lombardi A., et al. Large versus small femoral heads in metal on metal hip arthroplasty. J Arthroplasty 19 Suppl. 3 (2004) 44-48
    • (2004) J Arthroplasty , vol.19 , Issue.SUPPL. 3 , pp. 44-48
    • Cuckler, J.1    Moore, K.2    Lombardi, A.3
  • 38
    • 33750870614 scopus 로고    scopus 로고
    • Current in-vivo wear of metal-on-metal bearings assessed by exercise-related rise in plasma cobalt level
    • Kham M., Takahoshi T., Kurper J.H., et al. Current in-vivo wear of metal-on-metal bearings assessed by exercise-related rise in plasma cobalt level. J Orthop Res (2006) 2029-2035
    • (2006) J Orthop Res , pp. 2029-2035
    • Kham, M.1    Takahoshi, T.2    Kurper, J.H.3
  • 39
    • 34249780509 scopus 로고    scopus 로고
    • Prothèses métal-métal cimentées de seconde génération : 10 ans de suivi clinique et biologique
    • Lazennec J.Y., Boyer P., Poupon J., et al. Prothèses métal-métal cimentées de seconde génération : 10 ans de suivi clinique et biologique. Rev Chir Orthop 96 (2007) 298-302
    • (2007) Rev Chir Orthop , vol.96 , pp. 298-302
    • Lazennec, J.Y.1    Boyer, P.2    Poupon, J.3
  • 40
    • 0029810740 scopus 로고    scopus 로고
    • Metal-on-metal surface replacement of the hip: experience of the McMinn prosthesis
    • McMinn D., Treacy R., Lin K., et al. Metal-on-metal surface replacement of the hip: experience of the McMinn prosthesis. Clin Orthop 329 S (1996) 589-598
    • (1996) Clin Orthop , vol.329 S , pp. 589-598
    • McMinn, D.1    Treacy, R.2    Lin, K.3
  • 41
    • 33845510652 scopus 로고    scopus 로고
    • Highly cross-linked polyethylene in total hip arthroplasty
    • Gordon A.C., D'Lima D., and Colwell C.W. Highly cross-linked polyethylene in total hip arthroplasty. J AAOS 14 (2006) 511-523
    • (2006) J AAOS , vol.14 , pp. 511-523
    • Gordon, A.C.1    D'Lima, D.2    Colwell, C.W.3
  • 42
    • 16244371708 scopus 로고    scopus 로고
    • Harris WH: Third-body wear testing of a highly cross-linked acetabular liner: the effect of large femoral head size in the presence of particulate (PMMA) debris
    • Bragdon C.R., Jasty M., and Murotoglu O. Harris WH: Third-body wear testing of a highly cross-linked acetabular liner: the effect of large femoral head size in the presence of particulate (PMMA) debris. J. Arthroplasty 20 (2005) 379-385
    • (2005) J. Arthroplasty , vol.20 , pp. 379-385
    • Bragdon, C.R.1    Jasty, M.2    Murotoglu, O.3
  • 43
    • 26444582223 scopus 로고    scopus 로고
    • Impingement of acetabular cups in a hip simulator: comparison of highly cross-linked and conventional polyethylene
    • Holley K.G., Furman B.D., et al. Impingement of acetabular cups in a hip simulator: comparison of highly cross-linked and conventional polyethylene. J Arthroplasty 20 (2005) 77-86
    • (2005) J Arthroplasty , vol.20 , pp. 77-86
    • Holley, K.G.1    Furman, B.D.2
  • 44
    • 40749130415 scopus 로고    scopus 로고
    • Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double blind randomized and controlled trial using RSA
    • Glyn-Jones S., Isaas S., et al. Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double blind randomized and controlled trial using RSA. J Arthroplasty 23 (2008) 337-343
    • (2008) J Arthroplasty , vol.23 , pp. 337-343
    • Glyn-Jones, S.1    Isaas, S.2
  • 45
    • 34548225119 scopus 로고    scopus 로고
    • Incidence and volume of pelvic osteolysis at early follow-up with highly cross-linked and non cross-linked polyethylene
    • Leung S.B., Egawa H., Stepniewski A., et al. Incidence and volume of pelvic osteolysis at early follow-up with highly cross-linked and non cross-linked polyethylene. J Arthroplasty 22 (2007) 13439
    • (2007) J Arthroplasty , vol.22 , pp. 13439
    • Leung, S.B.1    Egawa, H.2    Stepniewski, A.3
  • 46
    • 2642564678 scopus 로고    scopus 로고
    • Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
    • Bradford L., Baker D.A., Graham J., et al. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. J Bone Joint Surg 86A (2004) 1271-1282
    • (2004) J Bone Joint Surg , vol.86 A , pp. 1271-1282
    • Bradford, L.1    Baker, D.A.2    Graham, J.3
  • 47
    • 0029989624 scopus 로고    scopus 로고
    • Early failure of hylamer acetabular inserts due to eccentric wear
    • Chmell M.J., Poss R., Thomas W.H., et al. Early failure of hylamer acetabular inserts due to eccentric wear. J Arthroplasty 11 (1996) 351-355
    • (1996) J Arthroplasty , vol.11 , pp. 351-355
    • Chmell, M.J.1    Poss, R.2    Thomas, W.H.3
  • 48
    • 0031811155 scopus 로고    scopus 로고
    • Early osteolysys with hylamer acetabular liners
    • Graeter J.H., and Nervis R. Early osteolysys with hylamer acetabular liners. J Arthroplasty 13 (1998) 464-466
    • (1998) J Arthroplasty , vol.13 , pp. 464-466
    • Graeter, J.H.1    Nervis, R.2
  • 49
    • 0033957831 scopus 로고    scopus 로고
    • Factors contributing to rapid wear and osteolysis in hip with modular acetabular bearings made of hylamer
    • Scott D.L., Campbelle P.A., et al. Factors contributing to rapid wear and osteolysis in hip with modular acetabular bearings made of hylamer. J Arthroplasty 15 (2000) 35-46
    • (2000) J Arthroplasty , vol.15 , pp. 35-46
    • Scott, D.L.1    Campbelle, P.A.2
  • 50
    • 0034987572 scopus 로고    scopus 로고
    • Read penetration into hylamer acetabular liner sterilized by gamma irradiation in air and in a nitrogen atmosphere
    • Yamauchi K6I, Hasegawa Y., et al. Read penetration into hylamer acetabular liner sterilized by gamma irradiation in air and in a nitrogen atmosphere. J Arthroplasty 16 (2001) 463-470
    • (2001) J Arthroplasty , vol.16 , pp. 463-470
    • Yamauchi K6I1    Hasegawa, Y.2
  • 51
    • 34547572936 scopus 로고    scopus 로고
    • Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation
    • Kop A.M., Dip G., et al. Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation. J Arthroplasty 22 (2007) 775-779
    • (2007) J Arthroplasty , vol.22 , pp. 775-779
    • Kop, A.M.1    Dip, G.2
  • 52
    • 34447339921 scopus 로고    scopus 로고
    • The biology of aseptic osteolysis
    • Holt G., Murnaghan C., et al. The biology of aseptic osteolysis. Clin Orthop Relat Res 460 (2007) 240-252
    • (2007) Clin Orthop Relat Res , vol.460 , pp. 240-252
    • Holt, G.1    Murnaghan, C.2
  • 53
    • 0242496251 scopus 로고    scopus 로고
    • Variation in the TNF gene promoter and risk of osteolysis after total hip arthroplasty
    • Wilkinson J.M., Wilson A.G., et al. Variation in the TNF gene promoter and risk of osteolysis after total hip arthroplasty. J Bone Miner Res 118 (2003) 1995-2001
    • (2003) J Bone Miner Res , vol.118 , pp. 1995-2001
    • Wilkinson, J.M.1    Wilson, A.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.