메뉴 건너뛰기




Volumn 11, Issue 2, 2009, Pages 158-166

Fracture strength of zirconia implants after artificial aging

Author keywords

Artificial mouth; Fracture strength; Titanium implants; Zirconia implants

Indexed keywords

ALUMINUM OXIDE; BIOMEDICAL AND DENTAL MATERIALS; CLEARFIL PORCELAIN BOND; CLEARFIL SE BOND; PANAVIA TPN S; PANAVIA TPN-S; PHOSPHATE; RESIN CEMENT; SILANE DERIVATIVE; TITANIUM; TOOTH CEMENT; Y TZP CERAMIC; Y-TZP CERAMIC; YTTRIUM; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 65649098399     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2008.00105.x     Document Type: Article
Times cited : (113)

References (51)
  • 2
    • 0033628712 scopus 로고    scopus 로고
    • Implants and components: Entering the new millennium
    • Binon PP. Implants and components: entering the new millennium. Int J Oral Maxillofac Implants 2000 15 : 76 94.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 76-94
    • Binon, P.P.1
  • 3
    • 0024005742 scopus 로고
    • Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants
    • Albrektsson T, Dahl E, Enbom L, et al. Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants. J Periodontol 1988 59 : 287 296.
    • (1988) J Periodontol , vol.59 , pp. 287-296
    • Albrektsson, T.1    Dahl, E.2    Enbom, L.3
  • 4
    • 0033094778 scopus 로고    scopus 로고
    • Optimal esthetics in single-tooth replacement with the re-implant system: A case report
    • Heydecke G, Kohal R, Gläser R. Optimal esthetics in single-tooth replacement with the re-implant system: a case report. Int J Prosthodont 1999 12 : 184 189.
    • (1999) Int J Prosthodont , vol.12 , pp. 184-189
    • Heydecke, G.1    Kohal, R.2    Gläser, R.3
  • 5
    • 0347510752 scopus 로고    scopus 로고
    • Das Zirkonoxidabutment - Ein neues vollkeramisches Konzept zur ästhetischen Verbesserung der Suprastruktur in der Implantologie
    • Wohlwend A, Studer S, Schärer P. Das Zirkonoxidabutment - ein neues vollkeramisches Konzept zur ästhetischen Verbesserung der Suprastruktur in der Implantologie. Quintessenz Zahntechn 1996 22 : 364 381.
    • (1996) Quintessenz Zahntechn , vol.22 , pp. 364-381
    • Wohlwend, A.1    Studer, S.2    Schärer, P.3
  • 6
    • 0033957748 scopus 로고    scopus 로고
    • The role of metals in autoimmunity and the link to neuroendocrinology
    • Stejskal J, Stejskal VD. The role of metals in autoimmunity and the link to neuroendocrinology. Neuroendocrinol Lett 1999 20 : 351 364.
    • (1999) Neuroendocrinol Lett , vol.20 , pp. 351-364
    • Stejskal, J.1    Stejskal, V.D.2
  • 9
    • 17944399367 scopus 로고
    • Das Tübinger Sofort-Implantat
    • Schulte W, Heimke G. Das Tübinger Sofort-Implantat. Quintessenz 1976 27 : 17 23.
    • (1976) Quintessenz , vol.27 , pp. 17-23
    • Schulte, W.1    Heimke, G.2
  • 10
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999 20 : 1 25.
    • (1999) Biomaterials , vol.20 , pp. 1-25
    • Piconi, C.1    MacCauro, G.2
  • 12
    • 10744222195 scopus 로고    scopus 로고
    • Current status of zirconia used in total hip implants
    • Suppl4
    • Clarke IC, Manaka M, Green DD, et al. Current status of zirconia used in total hip implants. J Bone Joint Surg Am 2003 85 (Suppl 4 73 84.
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 73-84
    • Clarke, I.C.1    Manaka, M.2    Green, D.D.3
  • 13
    • 1842783267 scopus 로고    scopus 로고
    • Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics
    • Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater 2004 20 : 449 456.
    • (2004) Dent Mater , vol.20 , pp. 449-456
    • Guazzato, M.1    Albakry, M.2    Ringer, S.P.3    Swain, M.V.4
  • 14
    • 0017995815 scopus 로고
    • Effect of stress-induced phase transformation on the properties of polycrystalline zirconia containing metastable tetragonal phase
    • Gupta TK, Lange FF, Bechtold JH. Effect of stress-induced phase transformation on the properties of polycrystalline zirconia containing metastable tetragonal phase. J Mater Sci 1978 13 : 1464 1470.
    • (1978) J Mater Sci , vol.13 , pp. 1464-1470
    • Gupta, T.K.1    Lange, F.F.2    Bechtold, J.H.3
  • 15
    • 0021963531 scopus 로고
    • Interface analysis of titanium and zirconium bone implants
    • Albrektsson T, Hansson HA, Ivarsson B. Interface analysis of titanium and zirconium bone implants. Biomaterials 1985 6 : 97 101.
    • (1985) Biomaterials , vol.6 , pp. 97-101
    • Albrektsson, T.1    Hansson, H.A.2    Ivarsson, B.3
  • 16
    • 0347510754 scopus 로고
    • Die Versorgung des Lückengebißes mit implantatgetragenen Brücken. Eine Longitudinalstudie über 7,5 Jahre
    • Strub JR, Rohner D, Schärer P. Die Versorgung des Lückengebißes mit implantatgetragenen Brücken. Eine Longitudinalstudie über 7,5 Jahre. Zeitschrift für Zahnärztliche Implantologie 1987 3 : 242 254.
    • (1987) Zeitschrift für Zahnärztliche Implantologie , vol.3 , pp. 242-254
    • Strub, J.R.1    Rohner, D.2    Schärer, P.3
  • 17
    • 20744457194 scopus 로고    scopus 로고
    • Bone tissue responses to surface-modified zirconia implants: A histomorphometric and removal torque study in the rabbit
    • Suppl1. 20.
    • Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modified zirconia implants: a histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res 2005 7 (Suppl 1 S13 20.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. 13
    • Sennerby, L.1    Dasmah, A.2    Larsson, B.3    Iverhed, M.4
  • 19
    • 0033129752 scopus 로고    scopus 로고
    • Wear of composite resin veneering materials in a dual-axis chewing simulator
    • Kern M, Strub JR, Lü X-Y. Wear of composite resin veneering materials in a dual-axis chewing simulator. J Oral Rehabil 1999 26 : 372 378.
    • (1999) J Oral Rehabil , vol.26 , pp. 372-378
    • Kern, M.1    Strub, J.R.2    Lü, X.-Y.3
  • 20
    • 0024987053 scopus 로고
    • In-vitro-Testverfahren zur Evaluation dentaler Restaurationssysteme. 1. Computergesteuerter Kausimulator
    • Krejci I, Reich T, Lutz F, Albertoni M. In-vitro-Testverfahren zur Evaluation dentaler Restaurationssysteme. 1. Computergesteuerter Kausimulator. Schweiz Monatsschr Zahnmed 1990 100 : 953 960.
    • (1990) Schweiz Monatsschr Zahnmed , vol.100 , pp. 953-960
    • Krejci, I.1    Reich, T.2    Lutz, F.3    Albertoni, M.4
  • 22
    • 0034440773 scopus 로고    scopus 로고
    • Biting and chewing in overdentures, full dentures, and natural dentitions
    • Fontijn-Tekamp FA, Slagter AP, Van Der Bilt A, et al. Biting and chewing in overdentures, full dentures, and natural dentitions. J Dent Res 2000 79 : 1519 1524.
    • (2000) J Dent Res , vol.79 , pp. 1519-1524
    • Fontijn-Tekamp, F.A.1    Slagter, A.P.2    Van Der Bilt, A.3
  • 23
    • 0024082346 scopus 로고
    • Vollkeramische Brücken. Gerüste aus Kern-oder Hartkernmassen
    • Schwickerath H. Vollkeramische Brücken. Gerüste aus Kern-oder Hartkernmassen. Dent Lab 1988 36 : 1081 1083.
    • (1988) Dent Lab , vol.36 , pp. 1081-1083
    • Schwickerath, H.1
  • 24
    • 0022663275 scopus 로고
    • Dauerfestigkeit von Keramik
    • Schwickerath H. Dauerfestigkeit von Keramik. Dtsch Zahnärztl Z 1986 41 : 264 266.
    • (1986) Dtsch Zahnärztl Z , vol.41 , pp. 264-266
    • Schwickerath, H.1
  • 25
    • 0033771089 scopus 로고    scopus 로고
    • Zirconia as a sliding material: Histologic, laboratory, and clinical data
    • Cales B. Zirconia as a sliding material: histologic, laboratory, and clinical data. Clin Orthop 2000 1 : 94 112.
    • (2000) Clin Orthop , vol.1 , pp. 94-112
    • Cales, B.1
  • 26
    • 0028434170 scopus 로고
    • Long-term in vivo and in vitro aging of a zirconia ceramic used in orthopaedy
    • Cales B, Stefani Y, Lilley E. Long-term in vivo and in vitro aging of a zirconia ceramic used in orthopaedy. J Biomed Mater Res 1994 28 : 619 624.
    • (1994) J Biomed Mater Res , vol.28 , pp. 619-624
    • Cales, B.1    Stefani, Y.2    Lilley, E.3
  • 27
    • 26844583254 scopus 로고    scopus 로고
    • What future for zirconia as a biomaterial?
    • Chevalier J. What future for zirconia as a biomaterial? Biomaterials 2006 27 : 535 543.
    • (2006) Biomaterials , vol.27 , pp. 535-543
    • Chevalier, J.1
  • 28
    • 0033222358 scopus 로고    scopus 로고
    • The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic
    • Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L. The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dent Mater 1999 15 : 426 433.
    • (1999) Dent Mater , vol.15 , pp. 426-433
    • Kosmac, T.1    Oblak, C.2    Jevnikar, P.3    Funduk, N.4    Marion, L.5
  • 29
    • 0022043289 scopus 로고
    • Limitation of maximum strength of zirconia toughened ceramics by transformation toughening increment
    • Swain MV. Limitation of maximum strength of zirconia toughened ceramics by transformation toughening increment. J Am Ceram Soc 1985 68 : C97 C99.
    • (1985) J Am Ceram Soc , vol.68
    • Swain, M.V.1
  • 30
    • 84979438879 scopus 로고
    • Strengthening by surface damage in metastable tetragonal zirconia
    • Gupta TK. Strengthening by surface damage in metastable tetragonal zirconia. J Am Ceram Soc 1980 63 : 117 121.
    • (1980) J Am Ceram Soc , vol.63 , pp. 117-121
    • Gupta, T.K.1
  • 31
    • 0020829509 scopus 로고
    • A technique for introducing surface compression into zirconia ceramics
    • Green DJ. A technique for introducing surface compression into zirconia ceramics. J Am Ceram Soc 1983 66 : C178 C179.
    • (1983) J Am Ceram Soc , vol.66
    • Green, D.J.1
  • 32
    • 31544457886 scopus 로고    scopus 로고
    • Microstructural and crystallographic surface changes after grinding zirconia-based dental ceramics
    • Denry IL, Holloway JA. Microstructural and crystallographic surface changes after grinding zirconia-based dental ceramics. J Biomed Mater Res B Appl Biomater 2006 76 : 440 448.
    • (2006) J Biomed Mater Res B Appl Biomater , vol.76 , pp. 440-448
    • Denry, I.L.1    Holloway, J.A.2
  • 33
    • 11844264547 scopus 로고    scopus 로고
    • Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic
    • Guazzato M, Quach L, Albakry M, Swain MV. Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic. J Dent 2005 33 : 9 18.
    • (2005) J Dent , vol.33 , pp. 9-18
    • Guazzato, M.1    Quach, L.2    Albakry, M.3    Swain, M.V.4
  • 34
    • 0035983868 scopus 로고    scopus 로고
    • Reliability and properties of ground Y-TZP-zirconia ceramics
    • Luthardt RG, Holzhüter M, Sandkuhl O, et al. Reliability and properties of ground Y-TZP-zirconia ceramics. J Dent Res 2002 81 : 487 491.
    • (2002) J Dent Res , vol.81 , pp. 487-491
    • Luthardt, R.G.1    Holzhüter, M.2    Sandkuhl, O.3
  • 35
    • 85047673230 scopus 로고
    • Low temperature degradation of Y-TZP materials
    • Swab JJ. Low temperature degradation of Y-TZP materials. J Mater Sci 1991 26 : 6706 6714.
    • (1991) J Mater Sci , vol.26 , pp. 6706-6714
    • Swab, J.J.1
  • 36
    • 0022077265 scopus 로고
    • Transformation of yttria-doped tetragonal ZrO2 polycrystals by annealing in water
    • Sato T, Shimada M. Transformation of yttria-doped tetragonal ZrO2 polycrystals by annealing in water. J Am Ceram Soc 1985 68 : 356 359.
    • (1985) J Am Ceram Soc , vol.68 , pp. 356-359
    • Sato, T.1    Shimada, M.2
  • 37
    • 28944447516 scopus 로고    scopus 로고
    • Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia
    • Deville S, Chevalier J, Gremillard L. Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia. Biomaterials 2006 27 : 2186 2192.
    • (2006) Biomaterials , vol.27 , pp. 2186-2192
    • Deville, S.1    Chevalier, J.2    Gremillard, L.3
  • 38
    • 0346461396 scopus 로고    scopus 로고
    • Influence of implant length and diameter on stress distribution: A finite element analysis
    • Himmlová L, Dostálová T, Kácovský A, Konvicková S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent 2004 91 : 20 25.
    • (2004) J Prosthet Dent , vol.91 , pp. 20-25
    • Himmlová, L.1    Dostálová, T.2    Kácovský, A.3    Konvicková, S.4
  • 39
    • 23944485873 scopus 로고    scopus 로고
    • Early clinical experience with a new one-piece implant system in single tooth sites
    • Parel SM, Schow SR. Early clinical experience with a new one-piece implant system in single tooth sites. J Oral Maxillofac Surg 2005 63 : 2 10.
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 2-10
    • Parel, S.M.1    Schow, S.R.2
  • 40
    • 20744450568 scopus 로고    scopus 로고
    • Minimally invasive flapless implant surgery: A prospective multicenter study
    • Suppl1. 27.
    • Becker W, Goldstein M, Becker BE, Sennerby L. Minimally invasive flapless implant surgery: a prospective multicenter study. Clin Implant Dent Relat Res 2005 7 (Suppl 1 S21 27.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. 21
    • Becker, W.1    Goldstein, M.2    Becker, B.E.3    Sennerby, L.4
  • 41
    • 0036516691 scopus 로고    scopus 로고
    • Flapless implant surgery: A 10-year clinical retrospective analysis
    • Campelo LD, Camara JR. Flapless implant surgery: a 10-year clinical retrospective analysis. Int J Oral Maxillofac Implants 2002 17 : 271 276.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 271-276
    • Campelo, L.D.1    Camara, J.R.2
  • 42
    • 4444311165 scopus 로고    scopus 로고
    • Soft tissue healing around implants placed immediately after tooth extraction without incision: A clinical report
    • Covani U, Barone A, Cornelini R, Crespi R. Soft tissue healing around implants placed immediately after tooth extraction without incision: a clinical report. Int J Oral Maxillofac Implants 2004 19 : 549 553.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 549-553
    • Covani, U.1    Barone, A.2    Cornelini, R.3    Crespi, R.4
  • 43
    • 0032110788 scopus 로고    scopus 로고
    • Immediate implant placement: A procedure without incisions
    • Schwartz-Arad D, Chaushu G. Immediate implant placement: a procedure without incisions. J Periodontol 1998 69 : 743 750.
    • (1998) J Periodontol , vol.69 , pp. 743-750
    • Schwartz-Arad, D.1    Chaushu, G.2
  • 44
    • 33847398730 scopus 로고    scopus 로고
    • A rationale for retrievability of fixed, implant-supported prostheses: A complication-based analysis
    • Gervais MJ, Wilson PR. A rationale for retrievability of fixed, implant-supported prostheses: a complication-based analysis. Int J Prosthodont 2007 20 : 13 24.
    • (2007) Int J Prosthodont , vol.20 , pp. 13-24
    • Gervais, M.J.1    Wilson, P.R.2
  • 46
    • 0037928812 scopus 로고    scopus 로고
    • A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years
    • Berglundh T, Persson L, Klinge B. A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years. J Clin Periodontol 2002 29 : 197 212.
    • (2002) J Clin Periodontol , vol.29 , pp. 197-212
    • Berglundh, T.1    Persson, L.2    Klinge, B.3
  • 47
    • 0037364681 scopus 로고    scopus 로고
    • Persistent acute inflammation at the implant-abutment interface
    • Broggini N, McManus LM, Hermann JS, et al. Persistent acute inflammation at the implant-abutment interface. J Dent Res 2003 82 : 232 237.
    • (2003) J Dent Res , vol.82 , pp. 232-237
    • Broggini, N.1    McManus, L.M.2    Hermann, J.S.3
  • 48
    • 0036775113 scopus 로고    scopus 로고
    • Influence of the size of the microgap on crestal bone levels in non-submerged dental implants: A radiographic study in the canine mandible
    • King GN, Hermann JS, Schoolfield JD, Buser D, Cochran DL. Influence of the size of the microgap on crestal bone levels in non-submerged dental implants: a radiographic study in the canine mandible. J Periodontol 2002 73 : 1111 1117.
    • (2002) J Periodontol , vol.73 , pp. 1111-1117
    • King, G.N.1    Hermann, J.S.2    Schoolfield, J.D.3    Buser, D.4    Cochran, D.L.5
  • 49
    • 0038505163 scopus 로고    scopus 로고
    • Role of the microgap between implant and abutment: A retrospective histologic evaluation in monkeys
    • Piattelli A, Vrespa G, Petrone G, Iezzi G, Annibali S, Scarano A. Role of the microgap between implant and abutment: a retrospective histologic evaluation in monkeys. J Periodontol 2003 74 : 346 352.
    • (2003) J Periodontol , vol.74 , pp. 346-352
    • Piattelli, A.1    Vrespa, G.2    Petrone, G.3    Iezzi, G.4    Annibali, S.5    Scarano, A.6
  • 51
    • 0034264116 scopus 로고    scopus 로고
    • Development of gingival esthetics in the edentulous patient with immediately loaded, single-stage, implant-supported fixed prostheses: A clinical report
    • Kinsel RP, Lamb RE, Moneim A. Development of gingival esthetics in the edentulous patient with immediately loaded, single-stage, implant-supported fixed prostheses: a clinical report. Int J Oral Maxillofac Implants 2000 15 : 711 721.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 711-721
    • Kinsel, R.P.1    Lamb, R.E.2    Moneim, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.