Volumn 36, Issue 5, 2009, Pages 1848-1858

Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant

Author keywords

6711 InterSource125; Breast implant; Film dosimetry; I 125; Low dose rate brachytherapy; MCNPX; Monte Carlo; TLD dosimetry

Indexed keywords

COMPOSITION EFFECTS; DOSIMETRY; HISTOLOGY; MONTE CARLO METHODS; ONCOLOGY; PHASE SPACE METHODS; RADIOTHERAPY;

EID: 65449135529     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3116777     Document Type: Article
Times cited : (34)

References (36)
  • 1
    • 29244483395 scopus 로고    scopus 로고
    • First report of a permanent breast seed implant (PBSI) as adjuvant radiation for early stage breast cancer
    • 0360-3016,. 10.1016/j.ijrob2005.06.031
    • J. P. Pignol, B. Keller, E. Rakovitch, and R. Sankreacha, " First report of a permanent breast seed implant (PBSI) as adjuvant radiation for early stage breast cancer.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 64, 176-181 (2006). 10.1016/j.ijrobp.2005.06.031
    • (2006) Int. J. Radiat. Oncol., Biol., Phys. , vol.64 , pp. 176-181
    • Pignol, J.P.1    Keller, B.2    Rakovitch, E.3    Sankreacha, R.4
  • 2
    • 18944395386 scopus 로고    scopus 로고
    • A permanent breast seed implant as partial breast radiation therapy for early-stage patients: A comparison of palladium-103 and iodine-125 isotopes based on radiation safety considerations
    • 0360-3016,. 10.1016/j.ijrob2004.10.014
    • B. Keller, R. Sankreacha, E. Rakovitch, P. O'Brien, and J. P. Pignol, " A permanent breast seed implant as partial breast radiation therapy for early-stage patients: A comparison of palladium-103 and iodine-125 isotopes based on radiation safety considerations.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 62, 358-365 (2005). 10.1016/j.ijrobp.2004.10.014
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.62 , pp. 358-365
    • Keller, B.1    Sankreacha, R.2    Rakovitch, E.3    O'Brien, P.4    Pignol, J.P.5
  • 3
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • 0094-2405,. 10.1118/1.597458
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43.," Med. Phys. 0094-2405 22, 209-234 (1995). 10.1118/1.597458
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 4
  • 5
    • 0024461534 scopus 로고
    • The accuracy of single-seed dose superposition for I-125 implants
    • 0094-2405,. 10.1118/1.596320
    • G. S. Burns and D. E. Raeside, " The accuracy of single-seed dose superposition for I-125 implants.," Med. Phys. 0094-2405 16, 627-631 (1989). 10.1118/1.596320
    • (1989) Med. Phys. , vol.16 , pp. 627-631
    • Burns, G.S.1    Raeside, D.E.2
  • 6
    • 23944509702 scopus 로고    scopus 로고
    • Dosimetric effects of seed anisotropy and interseed attenuation for P 103 d and i 125 prostate implants
    • 0094-2405,. 10.1118/1.1897466
    • O. Chibani, J. F. Williamson, and D. Todor, " Dosimetric effects of seed anisotropy and interseed attenuation for P 103 d and I 125 prostate implants.," Med. Phys. 0094-2405 32, 2557-2566 (2005). 10.1118/1.1897466
    • (2005) Med. Phys. , vol.32 , pp. 2557-2566
    • Chibani, O.1    Williamson, J.F.2    Todor, D.3
  • 7
    • 33644624376 scopus 로고    scopus 로고
    • Impact of interseed attenuation and tissue composition for permanent prostate implants
    • 0094-2405,. 10.1118/1.2168295
    • J. F. Carrier, L. Beaulieu, F. Therriault-Proulx, and R. Roy, " Impact of interseed attenuation and tissue composition for permanent prostate implants.," Med. Phys. 0094-2405 33, 595-604 (2006). 10.1118/1.2168295
    • (2006) Med. Phys. , vol.33 , pp. 595-604
    • Carrier, J.F.1    Beaulieu, L.2    Therriault-Proulx, F.3    Roy, R.4
  • 10
    • 33845310036 scopus 로고    scopus 로고
    • Monte Carlo and experimental dosimetry of an i 125 brachytherapy seed
    • 0094-2405,. 10.1118/1.2388158
    • J. Dolan, Z. Li, and J. F. Williamson, " Monte Carlo and experimental dosimetry of an I 125 brachytherapy seed.," Med. Phys. 0094-2405 33, 4675-4685 (2006). 10.1118/1.2388158
    • (2006) Med. Phys. , vol.33 , pp. 4675-4685
    • Dolan, J.1    Li, Z.2    Williamson, J.F.3
  • 11
    • 0036158984 scopus 로고    scopus 로고
    • Determination of dosimetric characteristics of InterSource125 Iodine brachytherapy source
    • 0969-8043,. 10.1016/S0969-8043(01)00258-5
    • A. S. Meigooni, M. M. Yoe-Sein, A. Y. Al-Otoom, and K. T. Sowards, " Determination of dosimetric characteristics of InterSource125 Iodine brachytherapy source.," Appl. Radiat. Isot. 0969-8043 56, 589-599 (2002). 10.1016/S0969-8043(01)00258-5
    • (2002) Appl. Radiat. Isot. , vol.56 , pp. 589-599
    • Meigooni, A.S.1    Yoe-Sein, M.M.2    Al-Otoom, A.Y.3    Sowards, K.T.4
  • 12
    • 0035190490 scopus 로고    scopus 로고
    • Dosimetric study of a new InterSource125 iodine seed
    • 0094-2405,. 10.1118/1.1415072
    • B. Reniers, S. Vynckier, and P. Scalliet, " Dosimetric study of a new InterSource125 iodine seed.," Med. Phys. 0094-2405 28, 2285-2288 (2001). 10.1118/1.1415072
    • (2001) Med. Phys. , vol.28 , pp. 2285-2288
    • Reniers, B.1    Vynckier, S.2    Scalliet, P.3
  • 13
    • 48349124498 scopus 로고    scopus 로고
    • A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants
    • 0094-2405,. 10.1118/1.2955754
    • H. Afsharpour, M. D'Amours, B. Cot́, J. F. Carrier, F. Verhaegen, and L. Beaulieu, " A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants.," Med. Phys. 0094-2405 35, 3671-3681 (2008). 10.1118/1.2955754
    • (2008) Med. Phys. , vol.35 , pp. 3671-3681
    • Afsharpour, H.1    D'Amours, M.2    Cot́, B.3    Carrier, J.F.4    Verhaegen, F.5    Beaulieu, L.6
  • 14
    • 22544440841 scopus 로고    scopus 로고
    • Precise radiochromic film dosimetry using a flat-bed document scanner
    • 0094-2405,. 10.1118/1.1929253
    • S. Devic, J. Seuntjens, E. Sham, and E. B. Podgorsak, " Precise radiochromic film dosimetry using a flat-bed document scanner.," Med. Phys. 0094-2405 32, 2245-2253 (2005). 10.1118/1.1929253
    • (2005) Med. Phys. , vol.32 , pp. 2245-2253
    • Devic, S.1    Seuntjens, J.2    Sham, E.3    Podgorsak, E.B.4
  • 15
    • 48349092548 scopus 로고    scopus 로고
    • The use of new GAFCHROMIC EBT film i 125 seed dosimetry in Solid Watere phantom
    • 0094-2405,. 10.1118/1.2955746
    • S. -T. Chiu-Tsao, D. Medich, and J. Munro III, " The use of new GAFCHROMIC EBT film I 125 seed dosimetry in Solid Water phantom.," Med. Phys. 0094-2405 35, 3787-3799 (2008). 10.1118/1.2955746
    • (2008) Med. Phys. , vol.35 , pp. 3787-3799
    • Chiu-Tsao, S.-T.1    Medich, D.2    Iii, M.J.3
  • 16
    • 0023717249 scopus 로고
    • A comparison of solid phantoms with water for dosimetry of i 125 brachytherapy sources
    • 0094-2405,. 10.1118/1.596182
    • A. S. Meigooni, J. A. Meli, and R. Nath, " A comparison of solid phantoms with water for dosimetry of I 125 brachytherapy sources.," Med. Phys. 0094-2405 15, 695-701 (1988). 10.1118/1.596182
    • (1988) Med. Phys. , vol.15 , pp. 695-701
    • Meigooni, A.S.1    Meli, J.A.2    Nath, R.3
  • 17
    • 0021703395 scopus 로고
    • Response of LiF powder to i 125 photons
    • 0094-2405,. 10.1118/1.595600
    • K. A. Weaver, " Response of LiF powder to I 125 photons.," Med. Phys. 0094-2405 11, 850-854 (1984). 10.1118/1.595600
    • (1984) Med. Phys. , vol.11 , pp. 850-854
    • Weaver, K.A.1
  • 18
    • 0032217054 scopus 로고    scopus 로고
    • Anisotropy functions of i 125 and i 192 r seed sources
    • 0094-2405,. 10.1118/1.598458
    • K. A. Weaver, " Anisotropy functions of I 125 and I 192 r seed sources.," Med. Phys. 0094-2405 25, 2271-2278 (1998). 10.1118/1.598458
    • (1998) Med. Phys. , vol.25 , pp. 2271-2278
    • Weaver, K.A.1
  • 19
    • 65449134865 scopus 로고    scopus 로고
    • MCNPX TM User's Manual LA-CP-05-0369, edited by D. B. Pelowitz (Los Alamos National Laboratory, NM).
    • MCNPX TM User's Manual LA-CP-05-0369, edited by, D. B. Pelowitz, (Los Alamos National Laboratory, NM, 2005).
    • (2005)
  • 20
    • 65449154078 scopus 로고    scopus 로고
    • MCNPX, Version 2.5.e (Los Alamos Laboratory, NM).
    • J. S. Hendricks, MCNPX, Version 2.5.e (Los Alamos Laboratory, NM, 2004).
    • (2004)
    • Hendricks, J.S.1
  • 21
    • 65449184642 scopus 로고    scopus 로고
    • MCNP - A general Monte Carlo N-particle transport code, version 4C," in Los Alamos National Laboratory, Report No. LA-13709-M
    • J. F. Briesmeister, "MCNP-A general Monte Carlo N-particle transport code, version 4C," in Los Alamos National Laboratory, Report No. LA-13709-M, 2000, pp. 2-56.
    • (2000) , pp. 2-56
    • Briesmeister, J.F.1
  • 22
    • 65449174385 scopus 로고    scopus 로고
    • Lawrence Livermore National Laboratory Report No. UCRL-JC-148180, (unpublished).
    • D. E. Cullen and R. E. MacFarlane, Lawrence Livermore National Laboratory Report No. UCRL-JC-148180, 2002 (unpublished).
    • (2002)
    • Cullen, D.E.1    MacFarlane, R.E.2
  • 24
    • 0037391530 scopus 로고    scopus 로고
    • Brachytherapy dosimetry of i 125 and P 103 d sources using an updated cross section library for the MCNP Monte Carlo transport code
    • 0094-2405,. 10.1118/1.1562942
    • T. D. Bohm, P. M. DeLuca, and L. A. DeWerd, " Brachytherapy dosimetry of I 125 and P 103 d sources using an updated cross section library for the MCNP Monte Carlo transport code.," Med. Phys. 0094-2405 30, 701-711 (2003). 10.1118/1.1562942
    • (2003) Med. Phys. , vol.30 , pp. 701-711
    • Bohm, T.D.1    Deluca, P.M.2    Dewerd, L.A.3
  • 25
    • 0001561153 scopus 로고
    • Atomic weights of the elements 1987
    • 0033-4545,. 10.1351/pac198860060841
    • J. R. de Laeter, " Atomic weights of the elements 1987.," Pure Appl. Chem. 0033-4545 60, 841-854 (1988). 10.1351/pac198860060841
    • (1988) Pure Appl. Chem. , vol.60 , pp. 841-854
    • De Laeter, J.R.1
  • 26
    • 65449164327 scopus 로고
    • Tissue substitutes in radiation dosimetry and measurement," ICRU Report No. 44.
    • "Tissue substitutes in radiation dosimetry and measurement," ICRU Report No. 44, 1989.
    • (1989)
  • 28
    • 33846566263 scopus 로고    scopus 로고
    • Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters
    • 0094-2405,. 10.1118/1.2400843
    • R. E. P. Taylor, G. Yegin, and D. W. O. Rogers, " Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters.," Med. Phys. 0094-2405 34, 445-457 (2007). 10.1118/1.2400843
    • (2007) Med. Phys. , vol.34 , pp. 445-457
    • Taylor, R.E.P.1    Yegin, G.2    Rogers, D.W.O.3
  • 29
    • 0026749829 scopus 로고
    • Interseed effects on dose for i 125 brachytherapy implants
    • 0094-2405,. 10.1118/1.596871
    • A. S. Meigooni, J. A. Meli, and R. Nath, " Interseed effects on dose for I 125 brachytherapy implants.," Med. Phys. 0094-2405 19, 385-390 (1992). 10.1118/1.596871
    • (1992) Med. Phys. , vol.19 , pp. 385-390
    • Meigooni, A.S.1    Meli, J.A.2    Nath, R.3
  • 30
    • 44649200461 scopus 로고    scopus 로고
    • BrachyGUI: An adjunct to an accelerated Monte Carlo photon transport code for patient-specific brachytherapy dose calculations and analysis
    • 10.1088/1742-6596/102/1/012018
    • E. Poon, Y. Le, J. F. Williamson, and F. Verhaegen, " BrachyGUI: An adjunct to an accelerated Monte Carlo photon transport code for patient-specific brachytherapy dose calculations and analysis.," J. Phys.: Conf. Ser. 102, 0120018 (2008). 10.1088/1742-6596/102/1/012018
    • (2008) J. Phys.: Conf. Ser. , vol.102 , pp. 0120018
    • Poon, E.1    Le, Y.2    Williamson, J.F.3    Verhaegen, F.4
  • 31
    • 62649136074 scopus 로고    scopus 로고
    • Tolerance and acceptance of partial breast irradiation using permanent breast P 103 d seed implant (PBSI)
    • J. P. Pignol, E. Rakovitch, B. Keller, R. Sankreacha, and C. Chartier, " Tolerance and acceptance of partial breast irradiation using permanent breast P 103 d seed implant (PBSI).," Int. J. Radiat. Oncol., Biol., Phys. 73 (5), 1482-1488 (2009).
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.73 , Issue.5 , pp. 1482-1488
    • Pignol, J.P.1    Rakovitch, E.2    Keller, B.3    Sankreacha, R.4    Chartier, C.5
  • 32
    • 65449180429 scopus 로고    scopus 로고
    • MCNP-A general Monte Carlo N-particle transport code, version 4C," in Los Alamos National Laboratory, Report No. LA-13709-M, 2-183.
    • J. F. Briesmeister, "MCNP-A general Monte Carlo N-particle transport code, version 4C," in Los Alamos National Laboratory, Report No. LA-13709-M, 2000, pp. 2-183.
    • (2000)
    • Briesmeister, J.F.1
  • 33
    • 0027508221 scopus 로고
    • The impact of anatomic variations on absorbed radiation doses in mammography
    • 0144-8420.
    • S. Eklund, A. Thilander, W. Leitz, and S. Mattsson, " The impact of anatomic variations on absorbed radiation doses in mammography.," Radiat. Prot. Dosim. 0144-8420 49, 167-170 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.49 , pp. 167-170
    • Eklund, S.1    Thilander, A.2    Leitz, W.3    Mattsson, S.4
  • 35
    • 38349000693 scopus 로고    scopus 로고
    • Tissue segmentation in Monte Carlo treatment planning: A simulation study using dual-energy CT images
    • 0167-8140,. 10.1016/j.radonc.2007.11.008
    • M. Bazalova, J. F. Carrier, L. Beaulieu, and F. Verhaegen, " Tissue segmentation in Monte Carlo treatment planning: A simulation study using dual-energy CT images.," Radiother. Oncol. 0167-8140 86, 93-98 (2008). 10.1016/j.radonc.2007.11.008
    • (2008) Radiother. Oncol. , vol.86 , pp. 93-98
    • Bazalova, M.1    Carrier, J.F.2    Beaulieu, L.3    Verhaegen, F.4
  • 36
    • 42449122744 scopus 로고    scopus 로고
    • Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations
    • 0031-9155,. 10.1088/0031-9155/53/9/015
    • M. Bazalova, J. F. Carrier, L. Beaulieu, and F. Verhaegen, " Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations.," Phys. Med. Biol. 0031-9155 53, 2439-2456 (2008). 10.1088/0031-9155/53/9/015
    • (2008) Phys. Med. Biol. , vol.53 , pp. 2439-2456
    • Bazalova, M.1    Carrier, J.F.2    Beaulieu, L.3    Verhaegen, F.4