Volumn 30, Issue 4, 2003, Pages 701-711

Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code

Author keywords

Brachytherapy; Cross section library; Dosimetry; MCNP; Monte Carlo

Indexed keywords

ATOMS; BENCHMARKING; CODES (SYMBOLS); DISEASES; DOSIMETRY; MONTE CARLO METHODS; ONCOLOGY; PHOTOELECTRICITY; RADIOTHERAPY; RATE CONSTANTS;

EID: 0037391530     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1562942     Document Type: Article
Times cited : (55)

References (41)
  • 2
    • 0032753788 scopus 로고    scopus 로고
    • Permanent prostate seed implant brachytherapy: Report of the American Association of Physicists in Medicine Task Group No. 64
    • Y. Yu, L. L. Anderson, Z. Li, D. E. Mellenberg, R. Nath, M. C. Schell, F. M. Waterman, A. Wu, and J. C. Blasko. "Permanent prostate seed implant brachytherapy: Report of the American Association of Physicists in Medicine Task Group No. 64," Med. Phys. 26, 2054-2076 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2054-2076
    • Yu, Y.1    Anderson, L.L.2    Li, Z.3    Mellenberg, D.E.4    Nath, R.5    Schell, M.C.6    Waterman, F.M.7    Wu, A.8    Blasko, J.C.9
  • 3
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • R. Nath, L. L. Anderson. G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, "Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43," Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 4
    • 0001959585 scopus 로고
    • Quantitative dosimetry methods in brachytherapy
    • edited by J. F. Williamson, B. R. Thomadsen, and R. Nath (Medical Physics Publishing, Madison, WI)
    • J. F. Williamson and A. S. Meigooni, "Quantitative dosimetry methods in brachytherapy," in Brachytherapy Physics, edited by J. F. Williamson, B. R. Thomadsen, and R. Nath (Medical Physics Publishing, Madison, WI, 1995), pp. 87-133.
    • (1995) Brachytherapy Physics , pp. 87-133
    • Williamson, J.F.1    Meigooni, A.S.2
  • 5
    • 0034004934 scopus 로고    scopus 로고
    • 103Pd interstitial brachytherapy seed
    • 103Pd interstitial brachytherapy seed," Med. Phys. 27, 643-654 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 643-654
    • Williamson, J.F.1
  • 6
    • 0025900734 scopus 로고
    • Comparison of measured and calculated dose rates in water near 1-125 and Ir-192 seeds
    • J. F. Williamson, "Comparison of measured and calculated dose rates in water near 1-125 and Ir-192 seeds," Med. Phys. 18, 776-786 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 776-786
    • Williamson, J.F.1
  • 7
    • 0028235964 scopus 로고
    • Comparison of radiation dosimetry in water and solid phantom materials for 1-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study
    • G. Luxton, "Comparison of radiation dosimetry in water and solid phantom materials for 1-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study," Med. Phys. 21, 631-641 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 631-641
    • Luxton, G.1
  • 8
  • 9
    • 0032427802 scopus 로고    scopus 로고
    • Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sources
    • J. F. Williamson, B. M. Coursey, L. A. DeWerd, W. F. Hanson. and R. Nath, "Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sources" Med. Phys. 25, 2269-2270 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2269-2270
    • Williamson, J.F.1    Coursey, B.M.2    DeWerd, L.A.3    Hanson, W.F.4    Nath, R.5
  • 10
    • 0003395844 scopus 로고    scopus 로고
    • edited by J. F. Briesmeister Los Alamos National Laboratory report. LA-13709-M April
    • "MCNP-A General Monte Carlo N-Particle Transport Code, Version 4C," edited by J. F. Briesmeister Los Alamos National Laboratory report. LA-13709-M April, 2000.
    • (2000) MCNP-A General Monte Carlo N-Particle Transport Code, Version 4C
  • 11
    • 0003883182 scopus 로고    scopus 로고
    • edited by L. S. Waters, Los Alamos National Laboratory Report, LA-UR 02-2607. April
    • "MCNPX User's Manual, Version 2.3.0," edited by L. S. Waters, Los Alamos National Laboratory Report, LA-UR 02-2607. April, 2002.
    • (2002) MCNPX User's Manual, Version 2.3.0
  • 12
    • 0023514509 scopus 로고
    • Monte Carlo evaluation of kerma at a point for photon transport problems
    • J. F. Williamson, "Monte Carlo evaluation of kerma at a point for photon transport problems," Med. Phys. 14, 567-576 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 567-576
    • Williamson, J.F.1
  • 17
    • 0034451289 scopus 로고    scopus 로고
    • Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations
    • H. Zaidi, "Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations," IEEE Trans. Nucl. Sci. 47, 2722-2735 (2000).
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 2722-2735
    • Zaidi, H.1
  • 18
    • 0035999411 scopus 로고    scopus 로고
    • Monte Carlo dose calculations in homogeneous media and at interfaces: A comparison between GEPTS, EGSnrc, MCNP and measurements
    • O. Chibani and X. A. Li, "Monte Carlo dose calculations in homogeneous media and at interfaces: A comparison between GEPTS, EGSnrc, MCNP and measurements," Med. Phys. 29, 835-847 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 835-847
    • Chibani, O.1    Li, X.A.2
  • 20
    • 0037149981 scopus 로고    scopus 로고
    • An analysis of MCNP cross-sections and tally methods for low-energy photon emitters
    • J. J. DeMarco, R. E. Wallace, and K. Boedeker, "An analysis of MCNP cross-sections and tally methods for low-energy photon emitters," Phys. Med. Biol. 47, 1321-1332 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1321-1332
    • DeMarco, J.J.1    Wallace, R.E.2    Boedeker, K.3
  • 21
    • 0035051575 scopus 로고    scopus 로고
    • Comparison of I-125 sources used for permanent interstitial implants
    • B. H. Heintz, R. E. Wallace, and J. M. Hevezi, "Comparison of I-125 sources used for permanent interstitial implants." Med. Phys. 28, 671-682 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 671-682
    • Heintz, B.H.1    Wallace, R.E.2    Hevezi, J.M.3
  • 26
    • 0003966102 scopus 로고    scopus 로고
    • Online, Gaithersburg, MD
    • M. J. Berger, J. H. Hubbell, S. M. Seltzer, J. S. Coursey, and D. S. Zucker, "XCOM: Photon Cross Section Database (version 1.2)," [Online] http://physics.nist.gov/xcom National Institute of Standards and Technology, Gaithersburg, MD, 1999. Originally published as M. J. Berger and J. H. Hubbell, "Photon Cross Sections on a Personal Computer," NBSIR 87-3597; and as M. J. Berger and J. H. Hubbell, "NIST X-ray and Gamma-ray Attenuation Coefficients and Cross Sections Database," NIST Standard Reference Database 8, National Institute of Standards and Technology, Gaithersburg, MD, 1987.
    • (1999) XCOM: Photon Cross Section Database (Version 1.2)
    • Berger, M.J.1    Hubbell, J.H.2    Seltzer, S.M.3    Coursey, J.S.4    Zucker, D.S.5
  • 27
    • 0003966099 scopus 로고    scopus 로고
    • Originally published, NBSIR 87-3597
    • M. J. Berger, J. H. Hubbell, S. M. Seltzer, J. S. Coursey, and D. S. Zucker, "XCOM: Photon Cross Section Database (version 1.2)," [Online] http://physics.nist.gov/xcom National Institute of Standards and Technology, Gaithersburg, MD, 1999. Originally published as M. J. Berger and J. H. Hubbell, "Photon Cross Sections on a Personal Computer," NBSIR 87-3597; and as M. J. Berger and J. H. Hubbell, "NIST X-ray and Gamma-ray Attenuation Coefficients and Cross Sections Database," NIST Standard Reference Database 8, National Institute of Standards and Technology, Gaithersburg, MD, 1987.
    • Photon Cross Sections on a Personal Computer
    • Berger, M.J.1    Hubbell, J.H.2
  • 28
    • 0345203600 scopus 로고
    • NIST Standard Reference Database 8, National Institute of Standards and Technology, Gaithersburg, MD
    • M. J. Berger, J. H. Hubbell, S. M. Seltzer, J. S. Coursey, and D. S. Zucker, "XCOM: Photon Cross Section Database (version 1.2)," [Online] http://physics.nist.gov/xcom National Institute of Standards and Technology, Gaithersburg, MD, 1999. Originally published as M. J. Berger and J. H. Hubbell, "Photon Cross Sections on a Personal Computer," NBSIR 87-3597; and as M. J. Berger and J. H. Hubbell, "NIST X-ray and Gamma-ray Attenuation Coefficients and Cross Sections Database," NIST Standard Reference Database 8, National Institute of Standards and Technology, Gaithersburg, MD, 1987.
    • (1987) NIST X-ray and Gamma-ray Attenuation Coefficients and Cross Sections Database
    • Berger, M.J.1    Hubbell, J.H.2
  • 30
    • 0032918665 scopus 로고    scopus 로고
    • Review of photon interaction cross section data in the medical and biological context
    • J. H. Hubbell, "Review of photon interaction cross section data in the medical and biological context." Phys. Med. Biol. 44, 1-22 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1-22
    • Hubbell, J.H.1
  • 33
  • 35
    • 85167048785 scopus 로고    scopus 로고
    • 9th International Symposium of Capture Gamma-Ray Spectroscopy and Related Topics, Budapest, Hungary, October. Data extracted from the NUDAT database, version 2.5, online
    • R. R. Kinsey et al., The NUDAT/PCNUDAT Program for Nuclear Data, 9th International Symposium of Capture Gamma-Ray Spectroscopy and Related Topics, Budapest, Hungary, October 1996. Data extracted from the NUDAT database, version 2.5, online at http://www.nndc.bnl.gov/
    • (1996) The NUDAT/PCNUDAT Program for Nuclear Data
    • Kinsey, R.R.1
  • 36
    • 0003852044 scopus 로고
    • NCRP Report No. 58, National Council on Radiation Protection and Measurements. Bethesda, MD
    • NCRP, A Handbook of Radioactivity Measurements, NCRP Report No. 58, National Council on Radiation Protection and Measurements. Bethesda, MD, 1985.
    • (1985) A Handbook of Radioactivity Measurements
  • 38
    • 0021907463 scopus 로고
    • Exposure contribution from Ti k x-rays produced in the titanium capsule of the clinical I-125 seed
    • H. Kubo, "Exposure contribution from Ti k x-rays produced in the titanium capsule of the clinical I-125 seed," Med. Phys. 12, 215-220 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 215-220
    • Kubo, H.1
  • 40
    • 0034068736 scopus 로고    scopus 로고
    • 192Ir brachytherapy sources: An EGS4 Monte Carlo study
    • 192Ir brachytherapy sources: an EGS4 Monte Carlo study," Phys. Med. Biol. 45, 703-717 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 703-717
    • Mainegra, E.1    Capote, R.2    Lopez, E.3
  • 41
    • 0034996402 scopus 로고    scopus 로고
    • Monte Carlo-aided dosimetry of the Source Tech Medical Model STM 1251 I-125 interstitial brachytherapy source
    • A. S. Kirov and J. F. Williamson, "Monte Carlo-aided dosimetry of the Source Tech Medical Model STM 1251 I-125 interstitial brachytherapy source," Med. Phys. 28, 764-772 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 764-772
    • Kirov, A.S.1    Williamson, J.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.