메뉴 건너뛰기




Volumn 42, Issue 1, 2009, Pages 51-60

Repeatability and concordance of the Pentacam system. Comparative study of corneal parameters measured with Pentacam and Atlas

Author keywords

Concordance; Corneal topography; Optical aberrations; Reliability study; Scheimpflug imaging; Zernike coefficients

Indexed keywords


EID: 65449117644     PISSN: 00303917     EISSN: 21718814     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (31)
  • 1
    • 0002202438 scopus 로고
    • The retinal image in the human eye
    • Pergamon, Oxford
    • W. N. Channan, "The retinal image in the human eye", in Progress in Retinal Research. Pergamon, Oxford (1983).
    • (1983) Progress in Retinal Research
    • Channan, W.N.1
  • 3
    • 0001444109 scopus 로고    scopus 로고
    • Contribution of corneal and lens to the aberrations of the human eye
    • P. Artal, A. Guirao, "Contribution of corneal and lens to the aberrations of the human eye", Opt Lett. 23, 1713-1715 (1998).
    • (1998) Opt Lett , vol.23 , pp. 1713-1715
    • Artal, P.1    Guirao, A.2
  • 4
    • 0034199902 scopus 로고    scopus 로고
    • Corneal wave-aberrations from videokeratography: Accuracy and limitations of the procedure
    • A. Guirao, P. Artal, "Corneal wave-aberrations from videokeratography: Accuracy and limitations of the procedure", J. Opt. Soc. Am. A 17, 955-965 (2000).
    • (2000) J. Opt. Soc. Am. A , vol.17 , pp. 955-965
    • Guirao, A.1    Artal, P.2
  • 6
    • 34247239221 scopus 로고    scopus 로고
    • Recent advances in ophthalmic anterior segment imaging: A new era for ophthalmic diagnosis?
    • A. Konstantopoulos, P. Hossain, D. F. Anderson, "Recent advances in ophthalmic anterior segment imaging: A new era for ophthalmic diagnosis?", Brit J Ophthalmol. 91, 551-557 (2007).
    • (2007) Brit J Ophthalmol , vol.91 , pp. 551-557
    • Konstantopoulos, A.1    Hossain, P.2    Anderson, D.F.3
  • 7
    • 28044436542 scopus 로고    scopus 로고
    • C. O'Donnell, C. Maldonado-Codina, Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS pentacam, Cornea 24, 920-924 (2005). 8 Y. Barkana, Y. Gerber, U. Elbaz, S. Schwartz, G. Ken-Dror, I. Avni, D. Zadok, Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry, J. Cataract Refr. Surg. 31, 1729-1735 (2005).
    • C. O'Donnell, C. Maldonado-Codina, "Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS pentacam", Cornea 24, 920-924 (2005). 8 Y. Barkana, Y. Gerber, U. Elbaz, S. Schwartz, G. Ken-Dror, I. Avni, D. Zadok, "Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry", J. Cataract Refr. Surg. 31, 1729-1735 (2005).
  • 8
    • 33646693629 scopus 로고    scopus 로고
    • Anterior chamber measurements using Pentacam rotating Scheimpflug camera
    • T. M. Rabsilber, R. Khoramnia, G. U. Auffarth, "Anterior chamber measurements using Pentacam rotating Scheimpflug camera", J. Cataract. Refr. Surg. 32, 456-459 (2006).
    • (2006) J. Cataract. Refr. Surg , vol.32 , pp. 456-459
    • Rabsilber, T.M.1    Khoramnia, R.2    Auffarth, G.U.3
  • 9
    • 33646762089 scopus 로고    scopus 로고
    • Evaluation of biometric methods for measuring the anterior chamber depht in the non-contact mode
    • B. Meinhardt, O. Stachs, J. Stave, R. Beck, R. Guthoff, "Evaluation of biometric methods for measuring the anterior chamber depht in the non-contact mode", Graef. Arch. Clin. Exp. 244, 559-564 (2006).
    • (2006) Graef. Arch. Clin. Exp , vol.244 , pp. 559-564
    • Meinhardt, B.1    Stachs, O.2    Stave, J.3    Beck, R.4    Guthoff, R.5
  • 10
    • 27644542761 scopus 로고    scopus 로고
    • Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound
    • B. Lackner, G. Schmidinger, S. Pieh, M. A. Funovics, C. Skorpik, "Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound", Optometry Vision Sci. 82, 892-899 (2005).
    • (2005) Optometry Vision Sci , vol.82 , pp. 892-899
    • Lackner, B.1    Schmidinger, G.2    Pieh, S.3    Funovics, M.A.4    Skorpik, C.5
  • 11
    • 29544440497 scopus 로고    scopus 로고
    • Comparison of three methods of measuring corneal thickness and anterior chamber depth
    • W. Buehl, D. Stojanac, S. Sacu, W. Drexler, O. Findl, "Comparison of three methods of measuring corneal thickness and anterior chamber depth", Am. J. Ophtalmol. 141, 7-12 (2006).
    • (2006) Am. J. Ophtalmol , vol.141 , pp. 7-12
    • Buehl, W.1    Stojanac, D.2    Sacu, S.3    Drexler, W.4    Findl, O.5
  • 12
    • 33746040471 scopus 로고    scopus 로고
    • Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device
    • G. Nemeth, A. Vajas, B, Kolozsvari, A. Berta, L. Modis Jr. "Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device", J. Cataract Refr. Surg. 32, 1331-1335 (2006).
    • (2006) J. Cataract Refr. Surg , vol.32 , pp. 1331-1335
    • Nemeth, G.1    Vajas, A.2    Kolozsvari, B.3    Berta, A.4    Modis Jr., L.5
  • 13
    • 33746960262 scopus 로고    scopus 로고
    • Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry
    • O. O. Ucakhan, M. Ozkan, A. Kampolat, "Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry", J. Cataract. Refr. Surg. 32, 970-977 (2006).
    • (2006) J. Cataract. Refr. Surg , vol.32 , pp. 970-977
    • Ucakhan, O.O.1    Ozkan, M.2    Kampolat, A.3
  • 14
    • 33747364036 scopus 로고    scopus 로고
    • Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy
    • J. B. Ciolino, M. W. Belin, "Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy", J. Cataract. Refr. Surg. 32, 1426-1431 (2006).
    • (2006) J. Cataract. Refr. Surg , vol.32 , pp. 1426-1431
    • Ciolino, J.B.1    Belin, M.W.2
  • 15
    • 33747893033 scopus 로고    scopus 로고
    • Comparison of Pentacam and Orbscan II on posterior curvature topography measurements in keratoconus eyes
    • S. Quisling, S. Sjoberg, B. Zimmerman, K. Goins, J. Sutphin, "Comparison of Pentacam and Orbscan II on posterior curvature topography measurements in keratoconus eyes", Ophthalmology 113, 1629-1632 (2006).
    • (2006) Ophthalmology , vol.113 , pp. 1629-1632
    • Quisling, S.1    Sjoberg, S.2    Zimmerman, B.3    Goins, K.4    Sutphin, J.5
  • 16
    • 33847163129 scopus 로고    scopus 로고
    • Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye
    • D. Chen, A. K. Lam, "Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye", J. Cataract. Refr. Surg. 33, 448-454 (2007).
    • (2007) J. Cataract. Refr. Surg , vol.33 , pp. 448-454
    • Chen, D.1    Lam, A.K.2
  • 17
    • 37349056419 scopus 로고    scopus 로고
    • Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements
    • H. Shankar, D. Taranath, T. Santhirathelagan, K. Pesudovs, "Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements", J. Cataract Refr. Surg. 34, 103-113 (2008).
    • (2008) J. Cataract Refr. Surg , vol.34 , pp. 103-113
    • Shankar, H.1    Taranath, D.2    Santhirathelagan, T.3    Pesudovs, K.4
  • 18
    • 33845495864 scopus 로고    scopus 로고
    • Comparison of different techniques of anterior chamber depth and keratometric measurements?
    • 2067
    • U. Elbaz, Y. Barkana, Y. Gerber, I. Avni, D. Zadok, "Comparison of different techniques of anterior chamber depth and keratometric measurements?, Am. J. Ophthalmol. 143, 48-53 (2067).
    • Am. J. Ophthalmol , vol.143 , pp. 48-53
    • Elbaz, U.1    Barkana, Y.2    Gerber, Y.3    Avni, I.4    Zadok, D.5
  • 19
    • 0031067860 scopus 로고    scopus 로고
    • Las mediciones clínicas en cardiología: Validez y errores de medición
    • J. Latour, V. Abraira, J. B. Cabello, J. López Sánchez, "Las mediciones clínicas en cardiología: Validez y errores de medición", Rev. Esp. Cardiol. 50, 117-128 (1997).
    • (1997) Rev. Esp. Cardiol , vol.50 , pp. 117-128
    • Latour, J.1    Abraira, V.2    Cabello, J.B.3    López Sánchez, J.4
  • 20
    • 0009947474 scopus 로고    scopus 로고
    • La evaluación de la fiabilidad en las observaciones clínicas: El coeficiente de correlación intraclase
    • L. Prieto, R. Lamarca, A. Casado, "La evaluación de la fiabilidad en las observaciones clínicas: El coeficiente de correlación intraclase", Med. Clin. 110, 142-145 (1998).
    • (1998) Med. Clin , vol.110 , pp. 142-145
    • Prieto, L.1    Lamarca, R.2    Casado, A.3
  • 21
    • 0032168704 scopus 로고    scopus 로고
    • Comparison of repeat videokeratography: Repeatability and accuracy
    • M. Jeandervin, J. Barr, "Comparison of repeat videokeratography: repeatability and accuracy", Optometry Vision Sci. 75, 663-669 (1998).
    • (1998) Optometry Vision Sci , vol.75 , pp. 663-669
    • Jeandervin, M.1    Barr, J.2
  • 22
    • 0036124279 scopus 로고    scopus 로고
    • The performance of four different corneal topographers on normal human corneas and its impact on orthokeratology lens fitting
    • P. Cho, A. K. Lam, J. Mountford, L. Ng, "The performance of four different corneal topographers on normal human corneas and its impact on orthokeratology lens fitting", Optometry Vision Sci. 79, 175-83 (2002).
    • (2002) Optometry Vision Sci , vol.79 , pp. 175-183
    • Cho, P.1    Lam, A.K.2    Mountford, J.3    Ng, L.4
  • 23
    • 84908219488 scopus 로고
    • Statical methods for assesing agreement between two methods of clinical measurement
    • J. M. Bland, D. G. Altman, "Statical methods for assesing agreement between two methods of clinical measurement", Lancet 1, 307-310 (1986).
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 0037244072 scopus 로고    scopus 로고
    • A new method for describing the aberrations of the eye using Zernike poyinomials
    • C. Campbell, "A new method for describing the aberrations of the eye using Zernike poyinomials", Optometry Vision Sci. 80, 79-83 (2003).
    • (2003) Optometry Vision Sci , vol.80 , pp. 79-83
    • Campbell, C.1
  • 26
    • 0021736206 scopus 로고
    • Mesure de l'accord entre deux juges: Cas quantitative
    • J. Fermanian, "Mesure de l'accord entre deux juges: Cas quantitative", Rev. Epidém. Santé Publ. 32 408-413 (1984).
    • (1984) Rev. Epidém. Santé Publ , vol.32 , pp. 408-413
    • Fermanian, J.1
  • 27
    • 33750315860 scopus 로고    scopus 로고
    • Repeatability and reproducibility of posterior corneal curvature measurements by combined scanning-slit and placido-disc topography after LASIK
    • M. J. Maldonado, J. C. Nieto, M. Diez-Cuenca, D. P. Piñero, "Repeatability and reproducibility of posterior corneal curvature measurements by combined scanning-slit and placido-disc topography after LASIK", Ophthalmology 113, 1918-1926 (2006).
    • (2006) Ophthalmology , vol.113 , pp. 1918-1926
    • Maldonado, M.J.1    Nieto, J.C.2    Diez-Cuenca, M.3    Piñero, D.P.4
  • 28
    • 0032167550 scopus 로고    scopus 로고
    • Evaluation of the EyeSys model II computerized videokeratoscope. Part I: Clinical assessment
    • T. Dave, D. Ruston, C. Fowler, "Evaluation of the EyeSys model II computerized videokeratoscope. Part I: Clinical assessment", Optometry Vision Sci 75, 647-655 (1998).
    • (1998) Optometry Vision Sci , vol.75 , pp. 647-655
    • Dave, T.1    Ruston, D.2    Fowler, C.3
  • 29
    • 0031680250 scopus 로고    scopus 로고
    • Comparison of three computerized videokeratoscopy systems with keratometry
    • R. C. Moura, B. L. Bowyer, S. X. Stevens, J. J. Rowsey, "Comparison of three computerized videokeratoscopy systems with keratometry", Cornea 17, 522-528 (1998).
    • (1998) Cornea , vol.17 , pp. 522-528
    • Moura, R.C.1    Bowyer, B.L.2    Stevens, S.X.3    Rowsey, J.J.4
  • 30
    • 33751325375 scopus 로고    scopus 로고
    • Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula
    • E. Borasio, J. Stevens, G. T. Smith, "Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula", J. Cataract. Refr. Surg. 32, 2004-2014 (2006).
    • (2006) J. Cataract. Refr. Surg , vol.32 , pp. 2004-2014
    • Borasio, E.1    Stevens, J.2    Smith, G.T.3
  • 31
    • 29544435798 scopus 로고    scopus 로고
    • The shape of the anterior and posterior surface of the aging human cornea
    • M. Dubbleman, V. A. D. P. SicamVADP, G. L. Van der Heijde, "The shape of the anterior and posterior surface of the aging human cornea", Vision Res. 46, 993-1001 (2006).
    • (2006) Vision Res , vol.46 , pp. 993-1001
    • Dubbleman, M.1    SicamVADP, V.A.D.P.2    Van der Heijde, G.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.