-
3
-
-
0020629020
-
Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations
-
JH Bargren JD Blaha MA Freeman 1983 Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations Clin Orthop Relat Res 173 178 183
-
(1983)
Clin Orthop Relat Res
, vol.173
, pp. 178-183
-
-
Bargren, J.H.1
Blaha, J.D.2
Freeman, M.A.3
-
4
-
-
27644524497
-
Computer navigation versus standard instrumentation for TKA: A single-surgeon experience
-
DOI 10.1097/01.blo.0000186561.70566.95
-
M Bolognesi A Hofmann 2005 Computer navigation versus standard instrumentation for TKA: a single-surgeon experience Clin Orthop Relat Res 440 162 169 (Pubitemid 41579210)
-
(2005)
Clinical Orthopaedics and Related Research
, Issue.440
, pp. 162-169
-
-
Bolognesi, M.1
Hofmann, A.2
-
5
-
-
33745609210
-
Kinematic navigation in total knee replacement - Experience from the first 50 cases
-
CW Chang CY Yang 2006 Kinematic navigation in total knee replacement-experience from the first 50 cases J Formos Med Assoc 105 468 474 (Pubitemid 43986080)
-
(2006)
Journal of the Formosan Medical Association
, vol.105
, Issue.6
, pp. 468-474
-
-
Chang, C.-W.1
Yang, C.-Y.2
-
6
-
-
23044438302
-
Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique
-
DOI 10.1016/j.arth.2005.04.004, PII S0883540305002299
-
PL Chin KY Yang SJ Yeo NN Lo 2005 Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique J Arthroplasty 20 618 626 (Pubitemid 41073476)
-
(2005)
Journal of Arthroplasty
, vol.20
, Issue.5
, pp. 618-626
-
-
Chin, P.L.1
Kuang, Y.Y.2
Seng, J.Y.3
Ngai, N.L.4
-
7
-
-
65049084144
-
A radiologic study of the reference line for measuring posterior slope angle on lateral view of the knee
-
CH Choi IH Sung HJ Kim 2007 A radiologic study of the reference line for measuring posterior slope angle on lateral view of the knee J Korean Orthop Assoc 42 236 240
-
(2007)
J Korean Orthop Assoc
, vol.42
, pp. 236-240
-
-
Choi, C.H.1
Sung, I.H.2
Kim, H.J.3
-
8
-
-
65049085683
-
Radiographic analysis of the tibial axis on the antero-posterior and lateral view of knee
-
JB Chung CD Han IW Yang JH Che 2005 Radiographic analysis of the tibial axis on the antero-posterior and lateral view of knee J Korean Knee Soc 17 58 63
-
(2005)
J Korean Knee Soc
, vol.17
, pp. 58-63
-
-
Chung, J.B.1
Han, C.D.2
Yang, I.W.3
Che, J.H.4
-
10
-
-
0025239766
-
Prediction of total knee motion using a three-dimensional computer-graphics model
-
DOI 10.1016/0021-9290(90)90368-D
-
A Garg PS Walker 1990 Prediction of total knee motion using a three-dimensional computer-graphics model J Biomech 23 45 58 (Pubitemid 20117197)
-
(1990)
Journal of Biomechanics
, vol.23
, Issue.1
, pp. 45-58
-
-
Garg, A.1
Walker, P.S.2
-
11
-
-
0346099499
-
Total knee arthroplasty implanted with and without kinematic navigation
-
DOI 10.1007/s00264-003-0501-6
-
R Hart M Janecek A Chaker P Bucek 2003 Total knee arthroplasty implanted with and without kinematic navigation Int Orthop 27 366 369 (Pubitemid 38044256)
-
(2003)
International Orthopaedics
, vol.27
, Issue.6
, pp. 366-369
-
-
Hart, R.1
Janecek, M.2
Chaker, A.3
Bucek, P.4
-
14
-
-
0035024525
-
Navigiert implantierte knietotalendoprothesen - Eine vergleichsstudie zum konventionellen instrumentarium
-
DOI 10.1055/s-2001-15041
-
JY Jenny C Boeri 2001 Navigated implantation of total knee endoprostheses-a comparative study with conventional instrumentation Z Orthop Ihre Grenzgeb 139 117 119 (Pubitemid 32424217)
-
(2001)
Zeitschrift fur Orthopadie und Ihre Grenzgebiete
, vol.139
, Issue.2
, pp. 117-119
-
-
Jenny, J.-Y.1
Boeri, C.2
-
15
-
-
26844512815
-
Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: A case-control study of 235 cases compared with 235 conventionally implanted prostheses
-
DOI 10.1016/j.arth.2005.02.002, PII S0883540305001129
-
JY Jenny U Clemens S Kohler H Kiefer W Konermann RK Miehlke 2005 Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses J Arthroplasty 20 832 839 (Pubitemid 41463681)
-
(2005)
Journal of Arthroplasty
, vol.20
, Issue.7
, pp. 832-839
-
-
Jenny, J.-Y.1
Clemens, U.2
Kohler, S.3
Kiefer, H.4
Konermann, W.5
Miehlke, R.K.6
-
16
-
-
0024950157
-
Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty
-
CC Jiang JN Insall 1989 Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty Clin Orthop Relat Res 248 50 56 (Pubitemid 20204780)
-
(1989)
Clinical Orthopaedics and Related Research
, Issue.248
, pp. 50-56
-
-
Jiang, C.-C.1
Insall, J.N.2
-
17
-
-
4844219768
-
Effects of rotation on measurement of lower limb alignment for knee osteotomy
-
DOI 10.1016/j.orthres.2004.03.016, PII S0736026604000841
-
H Kawakami N Sugano K Yonenobu H Yoshikawa T Ochi A Hattori N Suzuki 2004 Effects of rotation on measurement of lower limb alignment for knee osteotomy J Orthop Res 22 1248 1253 (Pubitemid 39317915)
-
(2004)
Journal of Orthopaedic Research
, vol.22
, Issue.6
, pp. 1248-1253
-
-
Kawakami, H.1
Sugano, N.2
Yonenobu, K.3
Yoshikawa, H.4
Ochi, T.5
Hattori, A.6
Suzuki, N.7
-
18
-
-
0036888128
-
Underestimation of varus angulation in knees with flexion deformity
-
DOI 10.1016/S0968-0160(02)00049-2, PII S0968016002000492
-
T Koshino M Takeyama LS Jiang T Yoshida T Saito 2002 Underestimation of varus angulation in knees with flexion deformity Knee 9 275 279 (Pubitemid 35287525)
-
(2002)
Knee
, vol.9
, Issue.4
, pp. 275-279
-
-
Koshino, T.1
Takeyama, M.2
Jiang, L.S.3
Yoshida, T.4
Saito, T.5
-
19
-
-
0025358109
-
A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee
-
KA Krackow CL Pepe EJ Galloway 1990 A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee Orthopedics 13 861 868 (Pubitemid 20243953)
-
(1990)
Orthopedics
, vol.13
, Issue.8
, pp. 861-868
-
-
Krackow, K.A.1
Pepe, C.L.2
Galloway, E.J.3
-
20
-
-
19944432952
-
Importance of the lateral anatomic tibial slope as a guide to the tibial cut in total knee arthroplasty in Japanese patients
-
DOI 10.1007/s00776-004-0855-7
-
T Kuwano K Urabe H Miura R Nagamine S Matsuda M Satomura T Sasaki S Sakai H Honda Y Iwamoto 2005 Importance of the lateral anatomic tibial slope as a guide to the tibial cut in total knee arthroplasty in Japanese patients J Orthop Sci 10 42 47 (Pubitemid 40193007)
-
(2005)
Journal of Orthopaedic Science
, vol.10
, Issue.1
, pp. 42-47
-
-
Kuwano, T.1
Urabe, K.2
Miura, H.3
Nagamine, R.4
Matsuda, S.5
Satomura, M.6
Sasaki, T.7
Sakai, S.8
Honda, H.9
Iwamoto, Y.10
-
21
-
-
0038304575
-
Instrumentation pitfalls you just can't go on autopilot!
-
DOI 10.1054/arth.2003.50066
-
RS Laskin 2003 Instrumentation pitfalls: you just can't go on autopilot! J Arthroplasty 18 18 22 (Pubitemid 36542553)
-
(2003)
Journal of Arthroplasty
, vol.18
, Issue.1-3 SUPPL
, pp. 18-22
-
-
Laskin, R.S.1
-
22
-
-
33750627923
-
Computer-assisted navigation in TKA: Where we are and where we are going
-
RS Laskin B Beksaç 2006 Computer-assisted navigation in TKA: where we are and where we are going Clin Orthop Relat Res 452 127 131
-
(2006)
Clin Orthop Relat Res
, vol.452
, pp. 127-131
-
-
Laskin, R.S.1
Beksaç, B.2
-
23
-
-
0017353885
-
Influence of positioning of prosthesis in total knee replacement
-
PA Lotke ML Ecker 1977 Influence of positioning of prosthesis in total knee replacement J Bone Joint Surg Am 59 77 79
-
(1977)
J Bone Joint Surg Am
, vol.59
, pp. 77-79
-
-
Lotke, P.A.1
Ecker, M.L.2
-
24
-
-
0034880976
-
The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties
-
DOI 10.1054/arth.2001.23569
-
J Mahaluxmivala MJ Bankes P Nicolai CH Aldam PW Allen 2001 The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties J Arthroplasty 16 635 640 (Pubitemid 32751451)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.5
, pp. 635-640
-
-
Mahaluxmivala, J.1
Bankes, M.J.K.2
Nicolai, P.3
Aldam, C.H.4
Allen, P.W.5
-
25
-
-
0037257447
-
Tibial shaft axis does not always serve as a correct coronal landmark in total knee arthroplasty for varus knees
-
DOI 10.1054/arth.2003.50002
-
S Matsuda H Mizu-uchi H Miura R Nagamine K Urabe Y Iwamoto 2003 Tibial shaft axis does not always serve as a correct coronal landmark in total knee arthroplasty for varus knees J Arthroplasty 18 56 62 (Pubitemid 36164404)
-
(2003)
Journal of Arthroplasty
, vol.18
, Issue.1
, pp. 56-62
-
-
Matsuda, S.1
Mizu-Uchi, H.2
Miura, H.3
Nagamine, R.4
Urabe, K.5
Iwamoto, Y.6
-
26
-
-
33846839286
-
A prospective, randomized study of computer-assisted and conventional total knee arthroplasty: Three-dimensional evaluation of implant alignment and rotation
-
DOI 10.2106/JBJS.F.00386
-
G Matziolis D Krocker U Weiss S Tohtz C Perka 2007 A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation J Bone Joint Surg Am 89 236 243 (Pubitemid 46214339)
-
(2007)
Journal of Bone and Joint Surgery - Series A
, vol.89
, Issue.2
, pp. 236-243
-
-
Matziolis, G.1
Krocker, D.2
Weiss, U.3
Tohtz, S.4
Perka, C.5
-
27
-
-
0035022484
-
Navigation in der knieendoprothetik - Vorlaufige klinische erfahrungen und prospektiv vergleichende studie gegenuber konventioneller implantationstechnik
-
DOI 10.1055/s-2001-15040
-
RK Mielke U Clemens JH Jens S Kershally 2001 Navigation in knee endoprosthesis implantation-preliminary experiences and prospective comparative study with conventional implantation technique Z Orthop Ihre Grenzgeb 139 109 116 (Pubitemid 32424216)
-
(2001)
Zeitschrift fur Orthopadie und Ihre Grenzgebiete
, vol.139
, Issue.2
, pp. 109-116
-
-
Mielke, R.K.1
Clemens, U.2
Jens, J.-H.3
Kershally, S.4
-
28
-
-
65049088049
-
Comparison of the radiological results between linker-guided and navigation-guided total knee arthroplasty
-
YW Moon JG Seo HJ Kang YS Kim 2006 Comparison of the radiological results between linker-guided and navigation-guided total knee arthroplasty J Korean Knee Soc 18 39 46
-
(2006)
J Korean Knee Soc
, vol.18
, pp. 39-46
-
-
Moon, Y.W.1
Seo, J.G.2
Kang, H.J.3
Kim, Y.S.4
-
29
-
-
11244315174
-
Distal femoral cut perpendicular to the mechanical axis may induce varus instability in flexion in medial osteoarthritic knees with varus deformity in total knee arthroplasty: A pitfall of the navigation system
-
DOI 10.1007/s00776-004-0818-z
-
R Nagamine K Kondo S Ikemura A Shiranita S Nakashima T Hara H Ihara Y Sugioka 2004 Distal femoral cut perpendicular to the mechanical axis may induce varus instability in flexion in medial osteoarthritic knees with varus deformity in total knee arthroplasty: a pitfall of the navigation system J Orthop Sci 9 555 559 (Pubitemid 40064682)
-
(2004)
Journal of Orthopaedic Science
, vol.9
, Issue.6
, pp. 555-559
-
-
Nagamine, R.1
Kondo, K.2
Ikemura, S.3
Shiranita, A.4
Nakashima, S.5
Hara, T.6
Ihara, H.7
Sugioka, Y.8
-
30
-
-
0034892245
-
Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty
-
DOI 10.1054/arth.2001.23714
-
J Novotny MH Gonzalez FM Amirouche YC Li 2001 Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty J Arthroplasty 16 641 647 (Pubitemid 32751452)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.5
, pp. 641-647
-
-
Novotny, J.1
Gonzalez, M.H.2
Amirouche, F.M.L.3
Li, Y.C.4
-
31
-
-
0027170064
-
Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty
-
MH Oswald RP Jakob E Schneider HM Hoogewoud 1993 Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty J Arthroplasty 8 419 426 (Pubitemid 23246177)
-
(1993)
Journal of Arthroplasty
, vol.8
, Issue.4
, pp. 419-426
-
-
Oswald, M.H.1
Jakob, R.P.2
Schneider, E.3
Hoogewoud, H.-M.4
-
32
-
-
4444354636
-
Navigation in total-knee arthroplasty: CT-based implantation compared with the conventional technique
-
DOI 10.1080/00016470410001259
-
L Perlick H Bäthis M Tingart C Perlick J Grifka 2004 Navigation in total-knee arthroplasty: CT-based implantation compared with the conventional technique Acta Orthop Scand 75 464 470 (Pubitemid 39179534)
-
(2004)
Acta Orthopaedica Scandinavica
, vol.75
, Issue.4
, pp. 464-470
-
-
Perlick, L.1
Bathis, H.2
Tingart, M.3
Perlick, C.4
Grifka, J.5
-
33
-
-
0023893141
-
Radiographic assessment of knee alignment after total knee arthroplasty
-
TL Petersen GA Engh 1988 Radiographic assessment of knee alignment after total knee arthroplasty J Arthroplasty 3 67 72 (Pubitemid 18105678)
-
(1988)
Journal of Arthroplasty
, vol.3
, Issue.1
, pp. 67-72
-
-
Petersen, T.L.1
Engh, G.A.2
-
36
-
-
0030869964
-
The accuracy of femoral intramedullary guides in total knee arthroplasty
-
DOI 10.1016/S0883-5403(97)90141-8
-
SC Reed J Gollish 1997 The accuracy of femoral intramedullary guides in total knee arthroplasty J Arthroplasty 12 677 682 (Pubitemid 27427947)
-
(1997)
Journal of Arthroplasty
, vol.12
, Issue.6
, pp. 677-682
-
-
Reed, S.C.1
Gollish, J.2
-
37
-
-
0027936866
-
Long-term outcomes of contralateral knees after unilateral total knee arthroplasty for osteoarthritis
-
DOI 10.1016/0883-5403(94)90043-4
-
MA Ritter SA Herbst EM Keating PM Faris JB Meding 1994 Long-term survival analysis of a posterior cruciate-retaining total condylar total knee arthroplasty Clin Orthop Relat Res 309 136 145 (Pubitemid 24266576)
-
(1994)
Journal of Arthroplasty
, vol.9
, Issue.4
, pp. 347-349
-
-
Ritter, M.A.1
Carr, K.D.2
Keating, E.M.3
Faris, P.M.4
-
38
-
-
65049087444
-
Comparison of results of total knee arthroplasty performed using a navigation system and the conventional technique
-
EK Song JK Seon JY Chung SG Cho IK Kong 2006 Comparison of results of total knee arthroplasty performed using a navigation system and the conventional technique J Korean Orthop Assoc 41 1002 1007
-
(2006)
J Korean Orthop Assoc
, vol.41
, pp. 1002-1007
-
-
Song, E.K.1
Seon, J.K.2
Chung, J.Y.3
Cho, S.G.4
Kong, I.K.5
-
39
-
-
0043030086
-
Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study
-
M Sparmann B Wolke H Czupalla D Banzer A Zink 2003 Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study J Bone Joint Surg Br 85 830 835
-
(2003)
J Bone Joint Surg Br
, vol.85
, pp. 830-835
-
-
Sparmann, M.1
Wolke, B.2
Czupalla, H.3
Banzer, D.4
Zink, A.5
-
40
-
-
0036394724
-
Computer-assisted navigation in total knee replacement: Results of an initial experience in thirty-five patients
-
SD Stulberg P Loan V Sarin 2002 Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients J Bone Joint Surg Am 84A Suppl 2 90 98 (Pubitemid 35168340)
-
(2002)
Journal of Bone and Joint Surgery - Series A
, vol.84
, Issue.2 SUPPL
, pp. 90-98
-
-
Stulberg, S.D.1
Loan, P.2
Sarin, V.3
-
41
-
-
33845417222
-
Computer-assisted surgery versus manual total knee arthroplasty: A case-controlled study
-
SD Stulberg MA Yaffe SS Koo 2006 Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study J Bone Joint Surg Am 88 Suppl 4 47 54
-
(2006)
J Bone Joint Surg Am
, vol.88
, Issue.4 SUPPL
, pp. 47-54
-
-
Stulberg, S.D.1
Yaffe, M.A.2
Koo, S.S.3
|