메뉴 건너뛰기




Volumn 24, Issue 6, 2009, Pages 1937-1945

Microbial inactivation properties of a new antimicrobialantithrombotic catheter lock solution (citratemethylene blueparabens)

Author keywords

Biofilm; Catheter infection; CRBSI; Haemodialysis; Lock solution

Indexed keywords

ANTIINFECTIVE AGENT; CITRATE SODIUM PLUS METHYL PARABEN PLUS METHYLENE BLUE PLUS PROPYL PARABEN; HEPARIN; UNCLASSIFIED DRUG;

EID: 64649094132     PISSN: 09310509     EISSN: 14602385     Source Type: Journal    
DOI: 10.1093/ndt/gfn776     Document Type: Article
Times cited : (41)

References (60)
  • 1
    • 0034153198 scopus 로고    scopus 로고
    • Description of a new surveillance system for bloodstream and vascular access infections in outpatient hemodialysis centers
    • Tokars JI. Description of a new surveillance system for bloodstream and vascular access infections in outpatient hemodialysis centers. Semin Dial 2000; 13: 97-100
    • (2000) Semin Dial , vol.13 , pp. 97-100
    • Tokars, J.I.1
  • 2
    • 0037868239 scopus 로고    scopus 로고
    • Impact of dialysis dose and membrane on infection-related hospitalization and death: Results of the HEMO Study
    • Allon M, Depner TA, Radeva M et al. Impact of dialysis dose and membrane on infection-related hospitalization and death: results of the HEMO Study. J Am Soc Nephrol 2003; 14: 1863-1870
    • (2003) J Am Soc Nephrol , vol.14 , pp. 1863-1870
    • Allon, M.1    Depner, T.A.2    Radeva, M.3
  • 3
    • 14844335024 scopus 로고    scopus 로고
    • National surveillance of dialysis-associated diseases in the United States, 2002
    • Finelli L, Miller JT, Tokars JI et al. National surveillance of dialysis-associated diseases in the United States, 2002. Semin Dial 2005; 18: 52-61
    • (2005) Semin Dial , vol.18 , pp. 52-61
    • Finelli, L.1    Miller, J.T.2    Tokars, J.I.3
  • 4
    • 23844495124 scopus 로고    scopus 로고
    • Electronic reporting of infections associated with hemodialysis
    • Klevens RM, Tokars JI, Andrus M. Electronic reporting of infections associated with hemodialysis. Nephrol News Issues 2005; 19: 37-38, 43
    • (2005) Nephrol News Issues , vol.19 , Issue.37-38 , pp. 43
    • Klevens, R.M.1    Tokars, J.I.2    Andrus, M.3
  • 5
    • 30944443546 scopus 로고    scopus 로고
    • Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients
    • Weijmer MC, Van Den Dorpel MA, Van de Ven PJ et al. Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients. J Am Soc Nephrol 2005; 16: 2769-2777
    • (2005) J Am Soc Nephrol , vol.16 , pp. 2769-2777
    • Weijmer, M.C.1    Van Den Dorpel, M.A.2    Van de Ven, P.J.3
  • 6
    • 3342975641 scopus 로고    scopus 로고
    • Locking of tunneled hemodialysis catheters with gentamicin and heparin
    • McIntyre CW, Hulme LJ, Taal M et al. Locking of tunneled hemodialysis catheters with gentamicin and heparin. Kidney Int 2004; 66: 801-805
    • (2004) Kidney Int , vol.66 , pp. 801-805
    • McIntyre, C.W.1    Hulme, L.J.2    Taal, M.3
  • 7
    • 0036063589 scopus 로고    scopus 로고
    • Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: A randomized controlled study
    • Dogra GK, Herson H, Hutchison B et al. Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: a randomized controlled study. JAm Soc Nephrol 2002; 13: 2133-2139
    • (2002) JAm Soc Nephrol , vol.13 , pp. 2133-2139
    • Dogra, G.K.1    Herson, H.2    Hutchison, B.3
  • 8
    • 0036797703 scopus 로고    scopus 로고
    • A randomized controlled trial of topical exit site mupirocin application in patients with tunnelled, cuffed haemodialysis catheters
    • Johnson DW, MacGinley R, Kay TD et al. A randomized controlled trial of topical exit site mupirocin application in patients with tunnelled, cuffed haemodialysis catheters. Nephrol Dial Transplant 2002; 17: 1802-1807
    • (2002) Nephrol Dial Transplant , vol.17 , pp. 1802-1807
    • Johnson, D.W.1    MacGinley, R.2    Kay, T.D.3
  • 9
    • 12244307828 scopus 로고    scopus 로고
    • Hemodialysis infection prevention with polysporin ointment
    • Lok CE, Stanley KE, Hux JE et al. Hemodialysis infection prevention with polysporin ointment. J Am Soc Nephrol 2003; 14: 169-179
    • (2003) J Am Soc Nephrol , vol.14 , pp. 169-179
    • Lok, C.E.1    Stanley, K.E.2    Hux, J.E.3
  • 10
    • 33847614336 scopus 로고    scopus 로고
    • Catheter lock solutions to prevent bloodstream infections in high-risk hemodialysis patients
    • Feely T, Copley A, Bleyer AJ. Catheter lock solutions to prevent bloodstream infections in high-risk hemodialysis patients. Am J Nephrol 2007; 27: 24-29
    • (2007) Am J Nephrol , vol.27 , pp. 24-29
    • Feely, T.1    Copley, A.2    Bleyer, A.J.3
  • 11
    • 30944463821 scopus 로고    scopus 로고
    • Prevention of uncuffed hemodialysis catheter-related bacteremia using an antibiotic lock technique: A prospective, randomized clinical trial
    • Kim SH, Song KI, Chang JW et al. Prevention of uncuffed hemodialysis catheter-related bacteremia using an antibiotic lock technique: a prospective, randomized clinical trial. Kidney Int 2006; 69: 161-164
    • (2006) Kidney Int , vol.69 , pp. 161-164
    • Kim, S.H.1    Song, K.I.2    Chang, J.W.3
  • 12
    • 33746174152 scopus 로고    scopus 로고
    • Enhancing the survival of tunneled haemodialysis catheters using an antibiotic lock in the elderly: A randomised, double-blind clinical trial
    • Saxena AK, Panhotra BR, Sundaram DS et al. Enhancing the survival of tunneled haemodialysis catheters using an antibiotic lock in the elderly: a randomised, double-blind clinical trial. Nephrology (Carlton) 2006; 11: 299-305
    • (2006) Nephrology (Carlton) , vol.11 , pp. 299-305
    • Saxena, A.K.1    Panhotra, B.R.2    Sundaram, D.S.3
  • 13
    • 33748091349 scopus 로고    scopus 로고
    • Mortality risk factors in chronic haemodialysis patients with infective endocarditis
    • Nori US, Manoharan A, Thornby JI et al. Mortality risk factors in chronic haemodialysis patients with infective endocarditis. Nephrol Dial Transplant 2006; 21: 2184-2190
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 2184-2190
    • Nori, U.S.1    Manoharan, A.2    Thornby, J.I.3
  • 14
    • 21244457258 scopus 로고    scopus 로고
    • A randomized, controlled trial of a new vascular catheter flush solution (minocycline-EDTA) in temporary hemodialysis access
    • Bleyer AJ, Mason L, Russell G et al. A randomized, controlled trial of a new vascular catheter flush solution (minocycline-EDTA) in temporary hemodialysis access. Infect Control Hosp Epidemiol 2005; 26: 520-524
    • (2005) Infect Control Hosp Epidemiol , vol.26 , pp. 520-524
    • Bleyer, A.J.1    Mason, L.2    Russell, G.3
  • 15
    • 2942735234 scopus 로고    scopus 로고
    • Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution
    • Betjes MG, van Agteren M. Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution. Nephrol Dial Transplant 2004; 19: 1546-1551
    • (2004) Nephrol Dial Transplant , vol.19 , pp. 1546-1551
    • Betjes, M.G.1    van Agteren, M.2
  • 16
    • 44449152491 scopus 로고    scopus 로고
    • Preventing haemodialysis catheter-related bacteraemia with an antimicrobial lock solution: A meta-analysis of prospective randomized trials
    • Labriola L, Crott R, Jadoul M. Preventing haemodialysis catheter-related bacteraemia with an antimicrobial lock solution: a meta-analysis of prospective randomized trials. Nephrol Dial Transplant 2008; 23: 1666-1672
    • (2008) Nephrol Dial Transplant , vol.23 , pp. 1666-1672
    • Labriola, L.1    Crott, R.2    Jadoul, M.3
  • 17
    • 38149018427 scopus 로고    scopus 로고
    • A meta-analysis of hemodialysis catheter locking solutions in the prevention of catheter-related infection
    • Jaffer Y, Selby NM, Taal MW et al. A meta-analysis of hemodialysis catheter locking solutions in the prevention of catheter-related infection. Am J Kidney Dis 2008; 51: 233-241
    • (2008) Am J Kidney Dis , vol.51 , pp. 233-241
    • Jaffer, Y.1    Selby, N.M.2    Taal, M.W.3
  • 18
    • 38149057228 scopus 로고    scopus 로고
    • Prophylaxis against dialysis catheter-related bacteremia: A glimmer of hope
    • Allon M. Prophylaxis against dialysis catheter-related bacteremia: a glimmer of hope. Am J Kidney Dis 2008; 51: 165-168
    • (2008) Am J Kidney Dis , vol.51 , pp. 165-168
    • Allon, M.1
  • 19
    • 0036909238 scopus 로고    scopus 로고
    • Guidelines for the prevention of intravascular catheter-related infections
    • O'Grady NP, Alexander M, Dellinger EP et al. Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control 2002; 30: 476-489
    • (2002) Am J Infect Control , vol.30 , pp. 476-489
    • O'Grady, N.P.1    Alexander, M.2    Dellinger, E.P.3
  • 20
    • 0034090864 scopus 로고    scopus 로고
    • Prevention of intravascular catheter-related infections
    • Mermel LA. Prevention of intravascular catheter-related infections. Ann Intern Med 2000; 132: 391-402
    • (2000) Ann Intern Med , vol.132 , pp. 391-402
    • Mermel, L.A.1
  • 21
    • 0242509905 scopus 로고    scopus 로고
    • Overspill of catheter locking solution: Safety and efficacy aspects
    • Polaschegg HD, Shah C. Overspill of catheter locking solution: safety and efficacy aspects. ASAIO J 2003; 49: 713-715
    • (2003) ASAIO J , vol.49 , pp. 713-715
    • Polaschegg, H.D.1    Shah, C.2
  • 22
    • 38149010037 scopus 로고    scopus 로고
    • Emergence of multiresistant Staphylococcus epidermidis (MRSE) after lock antibiotic regimen by gentamicin in permanent hemodialysis catheters. Perspective study, 1999-2003 (Abstract)
    • Guerraoui A, Dacosta EE, Roche BB et al. Emergence of multiresistant Staphylococcus epidermidis (MRSE) after lock antibiotic regimen by gentamicin in permanent hemodialysis catheters. Perspective study, 1999-2003 (Abstract). J Am Soc Nephrol 2004; 15: 368A
    • (2004) J Am Soc Nephrol , vol.15
    • Guerraoui, A.1    Dacosta, E.E.2    Roche, B.B.3
  • 23
    • 0034791480 scopus 로고    scopus 로고
    • Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis
    • Karaaslan H, Peyronnet P, Benevent D et al. Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis. Nephrol Dial Transplant 2001; 16: 2072-2074
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 2072-2074
    • Karaaslan, H.1    Peyronnet, P.2    Benevent, D.3
  • 24
    • 27144520237 scopus 로고    scopus 로고
    • Citrate kinetics in patients receiving long-term hemodialysis therapy
    • Bauer E, Derfler K, Joukhadar C et al. Citrate kinetics in patients receiving long-term hemodialysis therapy. Am J Kidney Dis 2005; 46: 903-907
    • (2005) Am J Kidney Dis , vol.46 , pp. 903-907
    • Bauer, E.1    Derfler, K.2    Joukhadar, C.3
  • 26
    • 33745354751 scopus 로고    scopus 로고
    • Antimicrobial locks: Putting the lock on catheter infections
    • Manierski C, Besarab A. Antimicrobial locks: putting the lock on catheter infections. Adv Chronic Kidney Dis 2006; 13: 245-258
    • (2006) Adv Chronic Kidney Dis , vol.13 , pp. 245-258
    • Manierski, C.1    Besarab, A.2
  • 27
    • 33745387611 scopus 로고    scopus 로고
    • Avoiding trouble down the line: The management and prevention of hemodialysis catheter-related infections
    • Lok CE. Avoiding trouble down the line: the management and prevention of hemodialysis catheter-related infections. Adv Chronic Kidney Dis 2006; 13: 225-244
    • (2006) Adv Chronic Kidney Dis , vol.13 , pp. 225-244
    • Lok, C.E.1
  • 28
    • 34548822177 scopus 로고    scopus 로고
    • Use of antimicrobial catheter lock solutions to prevent catheter-related bacteremia
    • Bleyer AJ. Use of antimicrobial catheter lock solutions to prevent catheter-related bacteremia. Clin J Am Soc Nephrol 2007; 2: 1073-1078
    • (2007) Clin J Am Soc Nephrol , vol.2 , pp. 1073-1078
    • Bleyer, A.J.1
  • 29
    • 67651082856 scopus 로고    scopus 로고
    • Standards NCfCL. M23-A2, 21, no. 7. National Committee for Clinical Laboratory Standards, Wayne, PA, 2000
    • Standards NCfCL. M23-A2, vol. 21, no. 7. National Committee for Clinical Laboratory Standards, Wayne, PA, 2000
  • 30
    • 0018913306 scopus 로고
    • Antimicrobial activity of heparin
    • Rosett W, Hodges GR. Antimicrobial activity of heparin. J Clin Microbiol 1980; 11: 30-34
    • (1980) J Clin Microbiol , vol.11 , pp. 30-34
    • Rosett, W.1    Hodges, G.R.2
  • 31
    • 34547748451 scopus 로고    scopus 로고
    • The antimicrobial effect of heparin on common respiratory pathogens
    • Zappala C, Chandan S, George N et al. The antimicrobial effect of heparin on common respiratory pathogens. Crit Care Resusc 2007; 9: 157-160
    • (2007) Crit Care Resusc , vol.9 , pp. 157-160
    • Zappala, C.1    Chandan, S.2    George, N.3
  • 32
    • 23344440202 scopus 로고    scopus 로고
    • Heparin stimulates Staphylococcus aureus biofilm formation
    • Shanks RM, Donegan NP, Graber ML et al. Heparin stimulates Staphylococcus aureus biofilm formation. Infect Immun 2005; 73: 4596-4606
    • (2005) Infect Immun , vol.73 , pp. 4596-4606
    • Shanks, R.M.1    Donegan, N.P.2    Graber, M.L.3
  • 33
    • 33750282738 scopus 로고    scopus 로고
    • Catheter lock solutions: It's time for a change
    • Mandolfo S, Borlandelli S, Elli A. Catheter lock solutions: it's time for a change. J Vasc Access 2006; 7: 99-102
    • (2006) J Vasc Access , vol.7 , pp. 99-102
    • Mandolfo, S.1    Borlandelli, S.2    Elli, A.3
  • 34
    • 34547913104 scopus 로고    scopus 로고
    • In vitro activity of daptomycin and vancomycin lock solutions on staphylococcal biofilms in a central venous catheter model
    • LaPlante KL, Mermel LA. In vitro activity of daptomycin and vancomycin lock solutions on staphylococcal biofilms in a central venous catheter model. Nephrol Dial Transplant 2007; 22: 2239-2246
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 2239-2246
    • LaPlante, K.L.1    Mermel, L.A.2
  • 36
    • 33748748203 scopus 로고    scopus 로고
    • Comparison of low-dose gentamicin with minocycline as catheter lock solutions in the prevention of catheter-related bacteremia
    • Nori US, Manoharan A, Yee J et al. Comparison of low-dose gentamicin with minocycline as catheter lock solutions in the prevention of catheter-related bacteremia. Am J Kidney Dis 2006; 48: 596-605
    • (2006) Am J Kidney Dis , vol.48 , pp. 596-605
    • Nori, U.S.1    Manoharan, A.2    Yee, J.3
  • 37
    • 33748707529 scopus 로고    scopus 로고
    • Antibiotic-lock therapy for long-term intravascular catheter-related bacteraemia: Results of an open, non-comparative study
    • Fernandez-Hidalgo N, Almirante B, Calleja R et al. Antibiotic-lock therapy for long-term intravascular catheter-related bacteraemia: results of an open, non-comparative study. J Antimicrob Chemother 2006; 57: 1172-1180
    • (2006) J Antimicrob Chemother , vol.57 , pp. 1172-1180
    • Fernandez-Hidalgo, N.1    Almirante, B.2    Calleja, R.3
  • 38
    • 34447639777 scopus 로고    scopus 로고
    • Treatment of dialysis catheter-related Staphylococcus aureus bacteremia with an antibiotic lock: A quality improvement report
    • Maya ID, Carlton D, Estrada E et al. Treatment of dialysis catheter-related Staphylococcus aureus bacteremia with an antibiotic lock: a quality improvement report. Am J Kidney Dis 2007; 50: 289-295
    • (2007) Am J Kidney Dis , vol.50 , pp. 289-295
    • Maya, I.D.1    Carlton, D.2    Estrada, E.3
  • 39
    • 0034938075 scopus 로고    scopus 로고
    • Trisodium citrate 30% vs. heparin 5% as catheter lock in the interdialytic period in twin- or double-lumen dialysis catheters for intermittent haemodialysis
    • Stas KJ, Vanwalleghem J, De Moor B et al. Trisodium citrate 30% vs. heparin 5% as catheter lock in the interdialytic period in twin- or double-lumen dialysis catheters for intermittent haemodialysis. Nephrol Dial Transplant 2001; 16: 1521-1522
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 1521-1522
    • Stas, K.J.1    Vanwalleghem, J.2    De Moor, B.3
  • 40
    • 0002849084 scopus 로고    scopus 로고
    • Concentrated sodium citrate (23%) for catheter lock
    • Ash SR, Mankus RA, Sutton JM et al. Concentrated sodium citrate (23%) for catheter lock. Hemodial Int 2000; 4: 22-31
    • (2000) Hemodial Int , vol.4 , pp. 22-31
    • Ash, S.R.1    Mankus, R.A.2    Sutton, J.M.3
  • 41
    • 0032826783 scopus 로고    scopus 로고
    • Sodium citrate for filling haemodialysis catheters
    • Bayes B, Bonal J, Romero R. Sodium citrate for filling haemodialysis catheters. Nephrol Dial Transplant 1999; 14: 2532-2533
    • (1999) Nephrol Dial Transplant , vol.14 , pp. 2532-2533
    • Bayes, B.1    Bonal, J.2    Romero, R.3
  • 42
    • 0344034219 scopus 로고    scopus 로고
    • Risks related to catheter locking solutions containing concentrated citrate
    • Polaschegg HD, Sodemann K. Risks related to catheter locking solutions containing concentrated citrate. Nephrol Dial Transplant 2003; 18: 2688-2690
    • (2003) Nephrol Dial Transplant , vol.18 , pp. 2688-2690
    • Polaschegg, H.D.1    Sodemann, K.2
  • 44
    • 0027512294 scopus 로고
    • Efficacy of 1.4 percent sodium citrate in maintaining arterial catheter patency in patients in a medical ICU
    • Branson PK, McCoy RA, Phillips BA et al. Efficacy of 1.4 percent sodium citrate in maintaining arterial catheter patency in patients in a medical ICU. Chest 1993; 103: 882-885
    • (1993) Chest , vol.103 , pp. 882-885
    • Branson, P.K.1    McCoy, R.A.2    Phillips, B.A.3
  • 45
    • 0031730215 scopus 로고    scopus 로고
    • Filling hemodialysis catheters in the interdialytic period: Heparin versus citrate versus polygeline. a prospective randomized study
    • Buturovic J, Ponikvar R, Kandus A et al. Filling hemodialysis catheters in the interdialytic period: heparin versus citrate versus polygeline. a prospective randomized study. Artif Organs 1998; 22: 945-947
    • (1998) Artif Organs , vol.22 , pp. 945-947
    • Buturovic, J.1    Ponikvar, R.2    Kandus, A.3
  • 46
    • 0035459437 scopus 로고    scopus 로고
    • Four percent trisodium citrate as an alternative anticoagulant for maintaining patency of central venous hemodialysis catheters: Case report and discussion
    • Michaud D, Komant T, Pfefferle P. Four percent trisodium citrate as an alternative anticoagulant for maintaining patency of central venous hemodialysis catheters: case report and discussion. AmJCritCare 2001; 10: 351-354
    • (2001) AmJCritCare , vol.10 , pp. 351-354
    • Michaud, D.1    Komant, T.2    Pfefferle, P.3
  • 47
    • 0035017218 scopus 로고    scopus 로고
    • A comparative prospective study on the use of low concentrate citrate lock versus heparin lock in permanent dialysis catheters
    • Hendrickx L, Kuypers D, Evenepoel P et al. A comparative prospective study on the use of low concentrate citrate lock versus heparin lock in permanent dialysis catheters. Int J Artif Organs 2001; 24: 208-211
    • (2001) Int J Artif Organs , vol.24 , pp. 208-211
    • Hendrickx, L.1    Kuypers, D.2    Evenepoel, P.3
  • 48
    • 16344394305 scopus 로고    scopus 로고
    • A prospective, randomized, double-blind crossover study on the use of 5% citrate lock versus 10% citrate lock in permanent hemodialysis catheters
    • Meeus G, Kuypers DR, Claes K et al. A prospective, randomized, double-blind crossover study on the use of 5% citrate lock versus 10% citrate lock in permanent hemodialysis catheters. Blood Purif 2005; 23: 101-115
    • (2005) Blood Purif , vol.23 , pp. 101-115
    • Meeus, G.1    Kuypers, D.R.2    Claes, K.3
  • 49
    • 33846657539 scopus 로고    scopus 로고
    • Sodium citrate 4% locking solution for central venous dialysis catheters - an effective, more cost-efficient alternative to heparin
    • Grudzinski L, Quinan P, Kwok S et al. Sodium citrate 4% locking solution for central venous dialysis catheters - an effective, more cost-efficient alternative to heparin. Nephrol Dial Transplant 2007; 22: 471-476
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 471-476
    • Grudzinski, L.1    Quinan, P.2    Kwok, S.3
  • 50
    • 33846671513 scopus 로고    scopus 로고
    • Trisodium citrate 4% - an alternative to heparin capping of haemodialysis catheters
    • Lok CE, Appleton D, Bhola C et al. Trisodium citrate 4% - an alternative to heparin capping of haemodialysis catheters. Nephrol Dial Transplant 2007; 22: 477-483
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 477-483
    • Lok, C.E.1    Appleton, D.2    Bhola, C.3
  • 51
    • 42549150104 scopus 로고    scopus 로고
    • Citrate 4% versus Heparin and the Reduction of Thrombosis Study (CHARTS)
    • MacRae JM, Dojcinovic I, Djurdjev O et al. Citrate 4% versus Heparin and the Reduction of Thrombosis Study (CHARTS). Clin J Am Soc Nephrol 2008; 3: 369-374
    • (2008) Clin J Am Soc Nephrol , vol.3 , pp. 369-374
    • MacRae, J.M.1    Dojcinovic, I.2    Djurdjev, O.3
  • 52
    • 33748032064 scopus 로고    scopus 로고
    • Catheter lock solutions influence staphylococcal biofilm formation on abiotic surfaces
    • Shanks RM, Sargent JL, Martinez RM et al. Catheter lock solutions influence staphylococcal biofilm formation on abiotic surfaces. Nephrol Dial Transplant 2006; 21: 2247-2255
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 2247-2255
    • Shanks, R.M.1    Sargent, J.L.2    Martinez, R.M.3
  • 53
    • 0036810375 scopus 로고    scopus 로고
    • Methylene blue - a therapeutic dye for all seasons?
    • Wainwright M, Crossley KB. Methylene blue - a therapeutic dye for all seasons? J Chemother 2002; 14: 431-443
    • (2002) J Chemother , vol.14 , pp. 431-443
    • Wainwright, M.1    Crossley, K.B.2
  • 54
    • 0032521297 scopus 로고    scopus 로고
    • Photobactericidal activity of phenothiazinium dyes against methicillin-resistant strains of Staphylococcus aureus
    • Wainwright M, Phoenix DA, Laycock SL et al. Photobactericidal activity of phenothiazinium dyes against methicillin-resistant strains of Staphylococcus aureus. FEMS Microbiol Lett 1998; 160: 177-181
    • (1998) FEMS Microbiol Lett , vol.160 , pp. 177-181
    • Wainwright, M.1    Phoenix, D.A.2    Laycock, S.L.3
  • 55
    • 0034870092 scopus 로고    scopus 로고
    • Comparison of the methylene blue and toluidine blue photobactericidal efficacy against gram-positive and gram-negative microorganisms
    • Usacheva MN, Teichert MC, Biel MA. Comparison of the methylene blue and toluidine blue photobactericidal efficacy against gram-positive and gram-negative microorganisms. Lasers Surg Med 2001; 29: 165-173
    • (2001) Lasers Surg Med , vol.29 , pp. 165-173
    • Usacheva, M.N.1    Teichert, M.C.2    Biel, M.A.3
  • 56
    • 0032197884 scopus 로고    scopus 로고
    • Effect of increasing methylation on the ability of methylene blue to cause diaphorase-catalysed oxidation of NADH
    • Rice L, Phoenix DA, Wainwright M et al. Effect of increasing methylation on the ability of methylene blue to cause diaphorase-catalysed oxidation of NADH. Biochem Soc Trans 1998; 26: S319
    • (1998) Biochem Soc Trans , vol.26
    • Rice, L.1    Phoenix, D.A.2    Wainwright, M.3
  • 57
    • 0347511728 scopus 로고    scopus 로고
    • The interaction of lipopolysaccharides with phenothiazine dyes
    • Usacheva MN, Teichert MC, Biel MA. The interaction of lipopolysaccharides with phenothiazine dyes. Lasers Surg Med 2003; 33: 311-319
    • (2003) Lasers Surg Med , vol.33 , pp. 311-319
    • Usacheva, M.N.1    Teichert, M.C.2    Biel, M.A.3
  • 58
    • 0035022508 scopus 로고    scopus 로고
    • Safety assessment of propyl paraben: A review of the published literature
    • Soni MG, Burdock GA, Taylor SL et al. Safety assessment of propyl paraben: a review of the published literature. Food Chem Toxicol 2001; 39: 513-532
    • (2001) Food Chem Toxicol , vol.39 , pp. 513-532
    • Soni, M.G.1    Burdock, G.A.2    Taylor, S.L.3
  • 59
    • 0036774921 scopus 로고    scopus 로고
    • Evaluation of the health aspects of methyl paraben: A review of the published literature
    • Soni MG, Taylor SL, Greenberg NA et al. Evaluation of the health aspects of methyl paraben: a review of the published literature. Food Chem Toxicol 2002; 40: 1335-1373
    • (2002) Food Chem Toxicol , vol.40 , pp. 1335-1373
    • Soni, M.G.1    Taylor, S.L.2    Greenberg, N.A.3
  • 60
    • 17044392658 scopus 로고    scopus 로고
    • Safety assessment of esters of p-hydroxybenzoic acid (parabens)
    • Soni MG, Carabin IG, Burdock GA. Safety assessment of esters of p-hydroxybenzoic acid (parabens). Food Chem Toxicol 2005; 43: 985-1015
    • (2005) Food Chem Toxicol , vol.43 , pp. 985-1015
    • Soni, M.G.1    Carabin, I.G.2    Burdock, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.