Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID)
Dong L, Shiu A, Tung S and Boyer A 1997 Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID) Med. Phys. 24 263-7
Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: image-based correction of gantry motion nonidealities
Fahrig R and Holdsworth D W 2000 Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: image-based correction of gantry motion nonidealities Med. Phys 27 30-8
The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy
Hong T S, Tome W A, Chappell R J, Chinnaiyan P, Mehta M P and Harari P M 2005 The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy Int. J. Radiat. Oncol. Biol. Phys. 61 779-88
An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers' position
Rosca F, Lorenz F, Hacker F L, Chin L M, Ramakrishna N and Zygmanski P 2006 An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers' position Med. Phys. 33 1780-7
Radiosurgery target point alignment errors detected with portal film verification
Serago C F, Lewin A A, Houdek P V, Gonzalez-Arias S, Schwade J G, Abitbol A and Marcial-Vega V 1992 Radiosurgery target point alignment errors detected with portal film verification Int. J. Radiat. Oncol. Biol. Phys. 24 777-80
On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers
Treuer H, Hoevels M, Luyken K, Gierich A, Kocher M, Muller R P and Sturm V 2000 On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers Phys. Med. Biol. 45 2331-42
Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS)
Tsai J S 1996 Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS) Phys. Med. Biol. 41 1597-620
Quality assurance in stereotactic radiosurgery using a standard linear accelerator
Tsai J S, Buck B A, Svensson G K, Alexander E III, Cheng C W, Mannarino E G and Loeffler J S 1991 Quality assurance in stereotactic radiosurgery using a standard linear accelerator Int. J. Radiat. Oncol. Biol. Phys. 21 737-48
Introducing a system for automated control of rotation axes, collimator and laser adjustment for a medical linear accelerator
Winkler P, Bergmann H, Stuecklschweiger G and Guss H 2003 Introducing a system for automated control of rotation axes, collimator and laser adjustment for a medical linear accelerator Phys. Med. Biol. 48 1123-32
A personal-computer-based method to obtain 'star-shots' of mechanical and optical isocenters for gantry rotation of linear accelerators
Woo M K 2002 A personal-computer-based method to obtain 'star-shots' of mechanical and optical isocenters for gantry rotation of linear accelerators Med. Phys. 29 2753-5