Setup verification in linac-based radiosurgery

Author keywords

Linac based radiosurgery; Optical radiation detector; Quality assurance; Setup verification

Indexed keywords

ALIGNMENT; DEGREES OF FREEDOM (MECHANICS); IONIZING RADIATION; LINEAR ACCELERATORS; QUALITY ASSURANCE; RADIOTHERAPY;

EID: 0032825053     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598702     Document Type: Article
Times cited : (15)

References (11)
  • 2
    • 0023875610 scopus 로고    scopus 로고
    • A system for stereotactic radiosurgery with a linear accelerator
    • W. Lutz and K. R. Winston, "A system for stereotactic radiosurgery with a linear accelerator," Int. J. Radiat. Oncol., Biol., Phys. 14, 373-381 (1998).
    • (1998) Int. J. Radiat. Oncol., Biol., Phys. , vol.14 , pp. 373-381
    • Lutz, W.1    Winston, K.R.2
  • 3
  • 6
    • 0029842699 scopus 로고    scopus 로고
    • Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS)
    • S. S. Tsai, "Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS)," Phys. Med. Biol. 41, 1597-1620 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1597-1620
    • Tsai, S.S.1
  • 7
    • 0030872928 scopus 로고    scopus 로고
    • Quality assurance system to correct for errors arising from couch rotation in linac-based stereotactic radiosurgery
    • I. A. Brezovich, P. N. Pareek, W. E. Plott, and R. L. Jennelle, "Quality assurance system to correct for errors arising from couch rotation in linac-based stereotactic radiosurgery," Int. J. Radiat. Oncol., Biol., Phys. 38, 883-890 (1997).
    • (1997) Int. J. Radiat. Oncol., Biol., Phys. , vol.38 , pp. 883-890
    • Brezovich, I.A.1    Pareek, P.N.2    Plott, W.E.3    Jennelle, R.L.4
  • 8
    • 0031057615 scopus 로고    scopus 로고
    • Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID)
    • L. Dong, A. Shiu, S. Tung, and A. Boyer, "Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID)," Med. Phys. 24, 263-267 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 263-267
    • Dong, L.1    Shiu, A.2    Tung, S.3    Boyer, A.4
  • 9
    • 0031831866 scopus 로고    scopus 로고
    • Preliminary study of a metal a-Se-based portal detector
    • T. Falco, H. Wang, and B. G. Fallone, "Preliminary study of a metal a-Se-based portal detector," Med. Phys. 25, 814-823 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 814-823
    • Falco, T.1    Wang, H.2    Fallone, B.G.3
  • 11
    • 0031453264 scopus 로고    scopus 로고
    • Digital radiology using active matrix readout of amorphous selenium: Construction and evaluation of a real time prototype detector
    • W. Zhao, I. Blevis, S. German, J. A. Rowlands, D. Waechter, and Z. Huang, "Digital radiology using active matrix readout of amorphous selenium: Construction and evaluation of a real time prototype detector," Med. Phys. 24, 1834-1843 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1834-1843
    • Zhao, W.1    Blevis, I.2    German, S.3    Rowlands, J.A.4    Waechter, D.5    Huang, Z.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.