메뉴 건너뛰기




Volumn 54, Issue 7, 2009, Pages 2079-2092

A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode

Author keywords

[No Author keywords available]

Indexed keywords

ABSORBED DOSE; BRACHYTHERAPY; COUNTING MODES; DOSE RATES; EQUIVALENT DOSE; FEASIBILITY STUDIES; GAMMA-RAY; IN-VIVO; MONTE CARLO SIMULATIONS; ORDER OF MAGNITUDES; PILE-UP; PLASTIC OPTICAL FIBERS; PLASTIC SCINTILLATIONS; PLASTIC SCINTILLATORS; PULSE-HEIGHT SPECTRUM; SCINTILLATION PHOTONS; WATER PHANTOMS; WIDE DYNAMIC RANGES;

EID: 63649121532     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/7/015     Document Type: Article
Times cited : (12)

References (20)
  • 1
    • 0030168994 scopus 로고    scopus 로고
    • Radiation-induced light in optical fibres and plastic scintillators: Application to brachytherapy dosimetry
    • Arnfield M R, Gaballa H E, Zwicker R D, Islam Q and Schmidt-Ullrich R 1996 Radiation-induced light in optical fibres and plastic scintillators: application to brachytherapy dosimetry IEEE Trans. Nucl. Sci. 43 2077-84
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.3 , pp. 2077-2084
    • Arnfield, M.R.1    Gaballa, H.E.2    Zwicker, R.D.3    Islam, Q.4    Schmidt-Ullrich, R.5
  • 2
    • 0009065660 scopus 로고
    • On the nature of light induced by radiation in transparent media in radiotherapy
    • Beddar A S, Attix F H and Mackie T R 1989 On the nature of light induced by radiation in transparent media in radiotherapy Med. Phys. 16 683
    • (1989) Med. Phys. , vol.16 , pp. 683
    • Beddar, A.S.1    Attix, F.H.2    MacKie, T.R.3
  • 3
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration
    • Beddar A S, Mackie T R and Attix F H 1992 Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration Phys. Med. Biol. 37 1883-900
    • (1992) Phys. Med. Biol. , vol.37 , Issue.10 , pp. 1883-1900
    • Beddar, A.S.1    MacKie, T.R.2    Attix, F.H.3
  • 5
    • 0001330522 scopus 로고
    • Visible glow under exposure of gamma-radiation
    • Cherenkov P A 1934 Visible glow under exposure of gamma-radiation Dokl. Akad. Nauk SSSR 2 451
    • (1934) Dokl. Akad. Nauk SSSR , vol.2 , pp. 451
    • Cherenkov, P.A.1
  • 6
    • 0029867605 scopus 로고    scopus 로고
    • Direct reading measurement of absorbed dose with plastic scintillators-the general concept and applications to ophthalmic plaque dosimetry
    • Fluhs D, Heintz M, Indenkampen F and Wieczorek C 1996 Direct reading measurement of absorbed dose with plastic scintillators-the general concept and applications to ophthalmic plaque dosimetry Med. Phys. 23 427-34
    • (1996) Med. Phys. , vol.23 , Issue.3 , pp. 427-434
    • Fluhs, D.1    Heintz, M.2    Indenkampen, F.3    Wieczorek, C.4
  • 7
    • 2342631301 scopus 로고    scopus 로고
    • Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry
    • Geso M, Robinson N, Schumer W and Williams K 2004 Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry Australas. Phys. Eng. Sci. Med. 27 5-10
    • (2004) Australas. Phys. Eng. Sci. Med. , vol.27 , Issue.1 , pp. 5-10
    • Geso, M.1    Robinson, N.2    Schumer, W.3    Williams, K.4
  • 8
    • 0020213666 scopus 로고
    • Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV
    • Hubbell J H 1982 Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV Int. J. Appl. Radiat. Isot. 33 1269-90
    • (1982) Int. J. Appl. Radiat. Isot. , vol.33 , Issue.11 , pp. 1269-1290
    • Hubbell, J.H.1
  • 13
    • 0342614959 scopus 로고    scopus 로고
    • Miniature scintillating detector for small field radiation therapy
    • Letourneau D, Pouliot J and Roy R 1999 Miniature scintillating detector for small field radiation therapy Med. Phys. 26 2555-61
    • (1999) Med. Phys. , vol.26 , Issue.12 , pp. 2555-2561
    • Letourneau, D.1    Pouliot, J.2    Roy, R.3
  • 16
    • 36649026668 scopus 로고    scopus 로고
    • An absorbed dose to water standard for HDR 192Ir brachytherapy sources based on water calorimetry: Numerical and experimental proof-of-principle
    • Sarfehnia A, Stewart K and Seuntjens J 2007 An absorbed dose to water standard for HDR 192Ir brachytherapy sources based on water calorimetry: numerical and experimental proof-of-principle Med. Phys. 34 49-57
    • (2007) Med. Phys. , vol.34 , Issue.1 , pp. 49-57
    • Sarfehnia, A.1    Stewart, K.2    Seuntjens, J.3
  • 17
    • 33749836987 scopus 로고    scopus 로고
    • A fibre optic scintillator dosimeter for absorbed dose measurements of low-energy x-ray-emitting brachytherapy sources
    • Sliski A, Soares C and Mitch G M 2006 A fibre optic scintillator dosimeter for absorbed dose measurements of low-energy x-ray-emitting brachytherapy sources Radiat. Prot. Dosim. 120 24-7
    • (2006) Radiat. Prot. Dosim. , vol.120 , Issue.1-4 , pp. 24-27
    • Sliski, A.1    Soares, C.2    Mitch, G.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.