Volumn 27, Issue 1, 2004, Pages 5-10

Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry

Author keywords

Brachytherapy; Cardiovascular; Dosimetry; Scintillator

Indexed keywords

AMPLIFICATION; COMPUTER SIMULATION; MEDICINE; MONTE CARLO METHODS; PHOSPHORS; PHOTODIODES; PLASTICS; REAL TIME SYSTEMS; TISSUE; WATER;

EID: 2342631301     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178881     Document Type: Article
Times cited : (7)

References (18)
  • 1
    • 18344390645 scopus 로고    scopus 로고
    • Clinical and angiographic outcomes after use of Sr-90/Y-90 beta radiation for the treatment of in-stent restenosis: Results from the stents and radiation therapy 40 (START 40) registry
    • Suntharalingam, M., et al., Clinical and angiographic outcomes after use of Sr-90/Y-90 beta radiation for the treatment of in-stent restenosis: results from the stents and radiation therapy 40 (START 40) registry, Int. J. Radiation Oncol. Biol. Phys. 52: 1075, 2002.
    • (2002) Int. J. Radiation Oncol. Biol. Phys. , vol.52 , pp. 1075
    • Suntharalingam, M.1
  • 2
    • 0029152039 scopus 로고
    • High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angioplasty: Preliminary dosimetric test of a new source presentation
    • Popowski, Y., et al., High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angioplasty: Preliminary dosimetric test of a new source presentation, Int. J. Radiation Oncology Biol. Phys., 33(1): 211-215, 1995.
    • (1995) Int. J. Radiation Oncology Biol. Phys. , vol.33 , Issue.1 , pp. 211-215
    • Popowski, Y.1
  • 3
    • 0037148683 scopus 로고    scopus 로고
    • Intravascular brachytherapy, of the coronary, arteries
    • (February )
    • Fox. R.A., Intravascular brachytherapy, of the coronary, arteries, Phys. Med. Biol., 47: R1-R30, (February 2002).
    • (2002) Phys. Med. Biol. , vol.47
    • Fox, R.A.1
  • 4
    • 0032941450 scopus 로고    scopus 로고
    • Intravascular brachytherapy physics
    • AAPM report Task Group No. 60 February
    • AAPM report Task Group No. 60, Intravascular brachytherapy physics, Med. Phys. 26(2): 119-152, February 1999.
    • (1999) Med. Phys. , vol.26 , Issue.2 , pp. 119-152
  • 5
    • 0031942882 scopus 로고
    • Calibration and characterisation of beta-particles sources for intravascular brachytherapy
    • March
    • Soares, C.G., Halpern, D.G. and Wang, C.K., Calibration and characterisation of beta-particles sources for intravascular brachytherapy, Med. Phys. 25(3): 339-346, March 1988.
    • (1988) Med. Phys. , vol.25 , Issue.3 , pp. 339-346
    • Soares, C.G.1    Halpern, D.G.2    Wang, C.K.3
  • 6
    • 2342616937 scopus 로고    scopus 로고
    • Consistency standards for source strength of beta-particle sources
    • Soares, C.G., Consistency standards for source strength of beta-particle sources, Vascular Radiotherapy Monitor, 3(3): 59-63, 2001.
    • (2001) Vascular Radiotherapy Monitor , vol.3 , Issue.3 , pp. 59-63
    • Soares, C.G.1
  • 7
    • 0033678807 scopus 로고    scopus 로고
    • A Monte Carlo calculation of dosimetric parameters of Sr90/90Y and 192Ir SS sources for intravascular brachytherapy
    • November
    • Wang, R. and Li, X.A., A Monte Carlo calculation of dosimetric parameters of Sr90/90Y and 192Ir SS sources for intravascular brachytherapy, Med. Phys. 27(11): 2528-2535, November 2000.
    • (2000) Med. Phys. , vol.27 , Issue.11 , pp. 2528-2535
    • Wang, R.1    Li, X.A.2
  • 8
    • 0035117289 scopus 로고    scopus 로고
    • Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: A comparison between EGS4, EGSnrc and MNCP
    • February
    • Wang, R. and Li, X.A., Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: A comparison between EGS4, EGSnrc and MNCP, Med. Phys., 28(2): 134-141, February 2001.
    • (2001) Med. Phys. , vol.28 , Issue.2 , pp. 134-141
    • Wang, R.1    Li, X.A.2
  • 9
    • 0033854446 scopus 로고    scopus 로고
    • Verification of absolute dose rates for intravascular brachytherapy beta sources
    • Piessens, M. and Reynaert, N., Verification of absolute dose rates for intravascular brachytherapy beta sources, Phys. Med. Biol., 45: 2219-2231, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2219-2231
    • Piessens, M.1    Reynaert, N.2
  • 10
    • 0028293283 scopus 로고
    • A new Scintillator detectors system for the quality assurance of Cobalt and high-energy therapy machines
    • Beddar, A.S., A new Scintillator detectors system for the quality assurance of Cobalt and high-energy therapy machines, Phys. Med. Biol., 39: 253-263, 1994.
    • (1994) Phys. Med. Biol. , vol.39 , pp. 253-263
    • Beddar, A.S.1
  • 11
    • 0033930606 scopus 로고    scopus 로고
    • Water equivalence of plastic scintillators in megavoltage radiotherapy bremsstrahlung beams
    • Clift, M.A., Sutton, R.A. and Webb, D.V., Water equivalence of plastic scintillators in megavoltage radiotherapy bremsstrahlung beams, Phys. Med. Biol., 45: 1885-1895, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1885-1895
    • Clift, M.A.1    Sutton, R.A.2    Webb, D.V.3
  • 12
    • 0343776958 scopus 로고    scopus 로고
    • A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy
    • April
    • Bambynek, M., Flühs, D, and Quast, U., A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy, Med. Phys., 27(4): 662-667, April 2000.
    • (2000) Med. Phys. , vol.27 , Issue.4 , pp. 662-667
    • Bambynek, M.1    Flühs, D.2    Quast, U.3
  • 14
    • 0034760771 scopus 로고    scopus 로고
    • Dosimetric effect of source centring and residual plaque for β-emitting catheter based intravascular brachytherapy sources
    • October
    • Sehgal, V., Li, Z. and Palta, J.R., Dosimetric effect of source centring and residual plaque for β-emitting catheter based intravascular brachytherapy sources, Med. Phys., 28(10): 2162-2171, October 2001.
    • (2001) Med. Phys. , vol.28 , Issue.10 , pp. 2162-2171
    • Sehgal, V.1    Li, Z.2    Palta, J.R.3
  • 15
    • 85039518724 scopus 로고    scopus 로고
    • Private communication, ARPANSA, Yallambie Vic. Australia., September
    • Kotler, L., Private communication, ARPANSA, Yallambie Vic. Australia., September 2002.
    • (2002)
    • Kotler, L.1
  • 16
    • 0036122336 scopus 로고    scopus 로고
    • Monte Carlo dosimetry of tandem positioned B emitting intravascular brachytherapy source train
    • April
    • Wallace, S.A., Schumer, W., and Horrigan, M., Monte Carlo dosimetry of tandem positioned B emitting intravascular brachytherapy source train, Med. Phys., 26(4):, April 2002.
    • (2002) Med. Phys. , vol.26 , Issue.4
    • Wallace, S.A.1    Schumer, W.2    Horrigan, M.3
  • 17
    • 0345392718 scopus 로고    scopus 로고
    • A comparison of polyacrylamide gels and radiochromic film for source measurements in intravascular brachytherapy
    • Amin, M.N., Bonnett, D.E., and Harding, P.F., A comparison of polyacrylamide gels and radiochromic film for source measurements in intravascular brachytherapy, British Journal of Radiology, 76: 824-831, 2003.
    • (2003) British Journal of Radiology , vol.76 , pp. 824-831
    • Amin, M.N.1    Bonnett, D.E.2    Harding, P.F.3
  • 18
    • 0038107451 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry: Optimisation of light collection efficiency
    • Beddar, A.S., et al., Plastic scintillation dosimetry: optimisation of light collection efficiency, Phys. Med. Biol., 48: 1141-1152, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1141-1152
    • Beddar, A.S.1