Volumn 12, Issue 1, 2009, Pages 1-7

Journal of artificial organs 2008: The year in review

Author keywords

Apheresis; Artificial heart (basic); Artificial heart (clinical); Artificial liver; Artificial lung; Artificial pancreas; Artificial skin; Artificial valve; Biomaterial; Blood vessel prosthesis; Cardiopulmonary bypass; Dialysis; Pacemaker; Tissue engineering

Indexed keywords

BIOMATERIAL;

EID: 63549097294     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-009-0451-x     Document Type: Review
Times cited : (9)

References (42)
  • 1
    • 33645887818 scopus 로고    scopus 로고
    • Journal of Artificial Organs 2005: The year in review
    • Journal of Artificial Organs Editorial Committee.
    • Journal of Artificial Organs Editorial Committee. 2006 Journal of Artificial Organs 2005: the year in review J Artif Organs 9 1 7
    • (2006) J Artif Organs , vol.9 , pp. 1-7
  • 2
    • 34447306066 scopus 로고    scopus 로고
    • Journal of Artificial Organs 2006: The year in review
    • Journal of Artificial Organs Editorial Committee.
    • Journal of Artificial Organs Editorial Committee. 2007 Journal of Artificial Organs 2006: the year in review J Artif Organs 10 53 59
    • (2007) J Artif Organs , vol.10 , pp. 53-59
  • 3
    • 42149110886 scopus 로고    scopus 로고
    • Journal of Artificial Organs 2007: The year in review
    • Journal of Artificial Organs Editorial Committee.
    • Journal of Artificial Organs Editorial Committee. 2008 Journal of Artificial Organs 2007: the year in review J Artif Organs 11 4 11
    • (2008) J Artif Organs , vol.11 , pp. 4-11
  • 7
    • 59449096408 scopus 로고    scopus 로고
    • Improvement in magnetic field immunity of externally coupled transcutaneous energy transmission system for a totally implantable artificial heart
    • T. Yamamoto K. Koshiji A. Homma E. Tatsumi Y. Taenaka 2008 Improvement in magnetic field immunity of externally coupled transcutaneous energy transmission system for a totally implantable artificial heart J Artif Organs 11 238 240
    • (2008) J Artif Organs , vol.11 , pp. 238-240
    • Yamamoto, T.1    Koshiji, K.2    Homma, A.3    Tatsumi, E.4    Taenaka, Y.5
  • 8
    • 59449098971 scopus 로고    scopus 로고
    • Frequency analysis of high-intensity transient signals of transcranial doppler ultrasound in patients supported with a left ventricular assist device
    • K. Sato K. Hanazawa T. Okamoto S. Kyo J. Hayashi 2008 Frequency analysis of high-intensity transient signals of transcranial doppler ultrasound in patients supported with a left ventricular assist device J Artif Organs 11 201 203
    • (2008) J Artif Organs , vol.11 , pp. 201-203
    • Sato, K.1    Hanazawa, K.2    Okamoto, T.3    Kyo, S.4    Hayashi, J.5
  • 9
    • 42149172608 scopus 로고    scopus 로고
    • Oxygen metabolism during cardiopulmonary bypass with hemodilution using liposome-encapsulated hemoglobin in kid goats
    • R. Kansaku T. Mizuno E. Tatsumi Y. Ogata T. Ishizuka Y. Taenaka 2008 Oxygen metabolism during cardiopulmonary bypass with hemodilution using liposome-encapsulated hemoglobin in kid goats J Artif Organs 11 24 28
    • (2008) J Artif Organs , vol.11 , pp. 24-28
    • Kansaku, R.1    Mizuno, T.2    Tatsumi, E.3    Ogata, Y.4    Ishizuka, T.5    Taenaka, Y.6
  • 10
    • 53949107861 scopus 로고    scopus 로고
    • Poly-2-methoxyethylacrylate-coated bypass circuits reduce activation of coagulation system and inflammatory response in congenital cardiac surgery
    • Y. Suzuki K. Daitoku M. Minakawa K. Fukui I. Fukuda 2008 Poly-2-methoxyethylacrylate-coated bypass circuits reduce activation of coagulation system and inflammatory response in congenital cardiac surgery J Artif Organs 11 111 116
    • (2008) J Artif Organs , vol.11 , pp. 111-116
    • Suzuki, Y.1    Daitoku, K.2    Minakawa, M.3    Fukui, K.4    Fukuda, I.5
  • 11
    • 53949085957 scopus 로고    scopus 로고
    • Quantitative evaluation of hand cranking a roller pump in a crisis management drill
    • Y. Tomizawa A. Tokumine S. Ninomiya N. Momose T. Matayoshi 2008 Quantitative evaluation of hand cranking a roller pump in a crisis management drill J Artif Organs 11 117 122
    • (2008) J Artif Organs , vol.11 , pp. 117-122
    • Tomizawa, Y.1    Tokumine, A.2    Ninomiya, S.3    Momose, N.4    Matayoshi, T.5
  • 13
    • 42149184144 scopus 로고    scopus 로고
    • Surgery for acute aortic dissection using gelatin-resorcin-formalin glue: Perspective from 10 years of follow-up at a single center
    • M. Shiono 2008 Surgery for acute aortic dissection using gelatin-resorcin-formalin glue: Perspective from 10 years of follow-up at a single center Journal of Artificial Organs 11 19 23
    • (2008) Journal of Artificial Organs , vol.11 , pp. 19-23
    • Shiono, M.1
  • 14
    • 53949114415 scopus 로고    scopus 로고
    • Simulation of the fluid dynamics in artificial aortic roots: Comparison of two different types of prostheses
    • C.L. Bara J.F. Verhey 2008 Simulation of the fluid dynamics in artificial aortic roots: Comparison of two different types of prostheses Journal of Artificial Organs 11 123 129
    • (2008) Journal of Artificial Organs , vol.11 , pp. 123-129
    • Bara, C.L.1    Verhey, J.F.2
  • 15
    • 34548575509 scopus 로고    scopus 로고
    • Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device
    • H.S. Lee E. Akagawa A. Homma T. Tsukiya E. Tatsumi Y. Taenaka 2007 Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device J Artif Organs 10 181 185
    • (2007) J Artif Organs , vol.10 , pp. 181-185
    • Lee, H.S.1    Akagawa, E.2    Homma, A.3    Tsukiya, T.4    Tatsumi, E.5    Taenaka, Y.6
  • 16
    • 46749134309 scopus 로고    scopus 로고
    • Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: Synchronized analysis between visual images and pressure signals
    • H.S. Lee E. Akagawa T. Tsukiya E. Tatsumi Y. Taenaka 2008 Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: synchronized analysis between visual images and pressure signals J Artif Organs 11 60 66
    • (2008) J Artif Organs , vol.11 , pp. 60-66
    • Lee, H.S.1    Akagawa, E.2    Tsukiya, T.3    Tatsumi, E.4    Taenaka, Y.5
  • 18
    • 42149084478 scopus 로고    scopus 로고
    • Wavelet analysis of valve closing sound defects malfunction of bileaflet mechanical valve
    • H. Sugiki T. Murashita N. Shiiya Y. Matsui K. Sugiki 2008 Wavelet analysis of valve closing sound defects malfunction of bileaflet mechanical valve J Artif Organs 11 29 37
    • (2008) J Artif Organs , vol.11 , pp. 29-37
    • Sugiki, H.1    Murashita, T.2    Shiiya, N.3    Matsui, Y.4    Sugiki, K.5
  • 19
    • 46749123889 scopus 로고    scopus 로고
    • Correlation between ventricular flow field and valve closing sounds of mechanical mitral prostheses
    • T. Akutsu J. Saito R. Imai T. Suzuki X.D. Cao 2008 Correlation between ventricular flow field and valve closing sounds of mechanical mitral prostheses J Artif Organs 11 67 74
    • (2008) J Artif Organs , vol.11 , pp. 67-74
    • Akutsu, T.1    Saito, J.2    Imai, R.3    Suzuki, T.4    Cao, X.D.5
  • 20
    • 46749127373 scopus 로고    scopus 로고
    • Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses
    • T. Akutsu R. Imai J. Saito T. Suzuki 2008 Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses J Artif Organs 11 75 90
    • (2008) J Artif Organs , vol.11 , pp. 75-90
    • Akutsu, T.1    Imai, R.2    Saito, J.3    Suzuki, T.4
  • 21
    • 46749122277 scopus 로고    scopus 로고
    • Current status of the mechanical valve and bioprosthesis in Japan
    • S. Tokunaga R. Tominaga 2008 Current status of the mechanical valve and bioprosthesis in Japan J Artif Organs 11 53 59
    • (2008) J Artif Organs , vol.11 , pp. 53-59
    • Tokunaga, S.1    Tominaga, R.2
  • 22
    • 53949115046 scopus 로고    scopus 로고
    • Validity of identifying patient-prosthesis mismatch from the indexed effective orifice area
    • Y. Sakamoto K. Hashimoto H. Okuyama S. Ishii N. Kawada T. Inoue 2008 Validity of identifying patient-prosthesis mismatch from the indexed effective orifice area J Artif Organs 11 163 164
    • (2008) J Artif Organs , vol.11 , pp. 163-164
    • Sakamoto, Y.1    Hashimoto, K.2    Okuyama, H.3    Ishii, S.4    Kawada, N.5    Inoue, T.6
  • 24
    • 53949089819 scopus 로고    scopus 로고
    • Metallic biomaterials
    • M. Niinomi 2008 Metallic biomaterials J Artif Organs 11 105 110
    • (2008) J Artif Organs , vol.11 , pp. 105-110
    • Niinomi, M.1
  • 25
    • 59449107735 scopus 로고    scopus 로고
    • Polymeric membrane materials for artificial organs
    • H. Kawakami 2008 Polymeric membrane materials for artificial organs J Artif Organs 11 177 181
    • (2008) J Artif Organs , vol.11 , pp. 177-181
    • Kawakami, H.1
  • 26
    • 57849099465 scopus 로고    scopus 로고
    • Safety evaluation of surgical materials by cytotoxicity testing
    • B. Hexig R. Nakaoka T. Tsuchiya 2008 Safety evaluation of surgical materials by cytotoxicity testing J Artif Organs 11 204 211
    • (2008) J Artif Organs , vol.11 , pp. 204-211
    • Hexig, B.1    Nakaoka, R.2    Tsuchiya, T.3
  • 28
    • 53949121352 scopus 로고    scopus 로고
    • Comparison of mRNA expression of transcriptional factors and intercalated disk constituent proteins between in vivo and cultured cardiomyocytes
    • T. Nakamura Z. Feng T. Honda Y. Nomura T. Kitajima M. Umezu 2008 Comparison of mRNA expression of transcriptional factors and intercalated disk constituent proteins between in vivo and cultured cardiomyocytes J Artif Organs 11 134 140
    • (2008) J Artif Organs , vol.11 , pp. 134-140
    • Nakamura, T.1    Feng, Z.2    Honda, T.3    Nomura, Y.4    Kitajima, T.5    Umezu, M.6
  • 31
    • 53949107164 scopus 로고    scopus 로고
    • Characterization of acid-base status in maintenance hemodialysis: Physicochemical approach
    • A.B. Libório E.F. Daher M.C.M. de Castro 2008 Characterization of acid-base status in maintenance hemodialysis: physicochemical approach J Artif Organs 11 156 159
    • (2008) J Artif Organs , vol.11 , pp. 156-159
    • Libório, A.B.1    Daher, E.F.2    De Castro, M.C.M.3
  • 32
    • 53949114631 scopus 로고    scopus 로고
    • Molecular weight of polydisperse icodextrin effects its oncotic contribution to water transport
    • K. Nishimura Y. Kamiya K. Miyamoto S. Nomura T. Horiuchi 2008 Molecular weight of polydisperse icodextrin effects its oncotic contribution to water transport J Artif Organs 11 165 169
    • (2008) J Artif Organs , vol.11 , pp. 165-169
    • Nishimura, K.1    Kamiya, Y.2    Miyamoto, K.3    Nomura, S.4    Horiuchi, T.5
  • 33
    • 59449109887 scopus 로고    scopus 로고
    • Influence of blood corpuscles on the ultrafiltration of various proteins
    • A. Takezawa N. Tomisawa A.C. Yamashita 2008 Influence of blood corpuscles on the ultrafiltration of various proteins J Artif Organs 11 212 215
    • (2008) J Artif Organs , vol.11 , pp. 212-215
    • Takezawa, A.1    Tomisawa, N.2    Yamashita, A.C.3
  • 36
    • 46749139094 scopus 로고    scopus 로고
    • Clinical trial of allogeneic cultured dermal substitutes for intractable skin ulcer of the lower leg
    • N. Yamada E. Uchimura Y. Kuroyanagi 2008 Clinical trial of allogeneic cultured dermal substitutes for intractable skin ulcer of the lower leg J Artif Organs 11 100 103
    • (2008) J Artif Organs , vol.11 , pp. 100-103
    • Yamada, N.1    Uchimura, E.2    Kuroyanagi, Y.3
  • 37
    • 59449098673 scopus 로고    scopus 로고
    • Standardization for mass production of allogeneic cultured dermal substitute by measuring the amount of VEGF, bFGF, HGF, TGF-b, and IL-8
    • A. Hashimoto Y. Kuroyanagi 2008 Standardization for mass production of allogeneic cultured dermal substitute by measuring the amount of VEGF, bFGF, HGF, TGF-b, and IL-8 J Artif Organs 11 225 231
    • (2008) J Artif Organs , vol.11 , pp. 225-231
    • Hashimoto, A.1    Kuroyanagi, Y.2
  • 38
    • 59449108241 scopus 로고    scopus 로고
    • Comparative evaluation of re-epithelialization promoted by fresh or cryopreserved cultured dermal substitute
    • N. Yamada E. Uchinuma Y. Matsumoto Y. Kuroyanagi 2008 Comparative evaluation of re-epithelialization promoted by fresh or cryopreserved cultured dermal substitute J Artif Organs 11 221 224
    • (2008) J Artif Organs , vol.11 , pp. 221-224
    • Yamada, N.1    Uchinuma, E.2    Matsumoto, Y.3    Kuroyanagi, Y.4
  • 39
    • 59449091156 scopus 로고    scopus 로고
    • Application of cultured dermal substitute for amelioration of maxillary bone growth suppression after cleft palate operation in rats
    • N. Kurokawa M. Tsuji Y. Kuroyanagi 2008 Application of cultured dermal substitute for amelioration of maxillary bone growth suppression after cleft palate operation in rats J Artif Organs 11 216 220
    • (2008) J Artif Organs , vol.11 , pp. 216-220
    • Kurokawa, N.1    Tsuji, M.2    Kuroyanagi, Y.3
  • 41
    • 42149137935 scopus 로고    scopus 로고
    • Percutaneous and off-pump treatments for functional mitral regurgitation
    • K. Fukamachi 2008 Percutaneous and off-pump treatments for functional mitral regurgitation J Artif Organs 11 12 18
    • (2008) J Artif Organs , vol.11 , pp. 12-18
    • Fukamachi, K.1
  • 42
    • 85192572104 scopus 로고    scopus 로고
    • In remembrance of Dr. Tetsuzo Akutsu: A man who started artificial heart research
    • S. Takatani 2008 In remembrance of Dr. Tetsuzo Akutsu: a man who started artificial heart research J Artif Organs 11 1 3
    • (2008) J Artif Organs , vol.11 , pp. 1-3
    • Takatani, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.