메뉴 건너뛰기




Volumn 11, Issue 4, 2008, Pages 191-200

A nonpulsatile total artificial heart with 1/R control

Author keywords

1 R control; Fluctuation; Nonpulsatile; Total artificial heart; Undulation pump

Indexed keywords

ANIMAL EXPERIMENT; ARTERIAL PRESSURE; ARTICLE; ARTIFICIAL HEART; BLOOD FLOW; BLOOD PUMP; GOAT; HEART OUTPUT; HEMOLYSIS; IMPLANTATION; NONHUMAN; PRIORITY JOURNAL; PULSATILE FLOW; UNDULATION PUMP TOTAL ARTIFICIAL HEART;

EID: 59449090561     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-008-0434-3     Document Type: Article
Times cited : (9)

References (21)
  • 8
    • 1542614575 scopus 로고    scopus 로고
    • Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation
    • O.H. Frazier N.A. Shah T.J. Myers K.D. Robertson I.D. Gregoric R. Delgado 2004 Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation Cardiology 101 111 116
    • (2004) Cardiology , vol.101 , pp. 111-116
    • Frazier, O.H.1    Shah, N.A.2    Myers, T.J.3    Robertson, K.D.4    Gregoric, I.D.5    Delgado, R.6
  • 9
    • 0034823947 scopus 로고    scopus 로고
    • HeartMate left ventricular assist devices: A multigeneration of implanted blood pumps
    • T.R. Maher K.C. Butler V.L. Poirier D.B. Gernes 2001 HeartMate left ventricular assist devices: a multigeneration of implanted blood pumps Artif Organs 25 422 426
    • (2001) Artif Organs , vol.25 , pp. 422-426
    • Maher, T.R.1    Butler, K.C.2    Poirier, V.L.3    Gernes, D.B.4
  • 10
    • 10044257696 scopus 로고    scopus 로고
    • Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump
    • M.K. Chung N. Zhang G.D. Tansley Y. Qian 2004 Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump Artif Organs 28 1089 1094
    • (2004) Artif Organs , vol.28 , pp. 1089-1094
    • Chung, M.K.1    Zhang, N.2    Tansley, G.D.3    Qian, Y.4
  • 13
    • 3142688417 scopus 로고    scopus 로고
    • Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart: Effects of pulsatile and nonpulsatile flow
    • A. Baba P. Dobsak I. Saito T. Isoyama K. Takiura Y. Abe T. Chinzei J. Vasku K. Imachi 2004 Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart: effects of pulsatile and nonpulsatile flow ASAIO J 50 321 327
    • (2004) ASAIO J , vol.50 , pp. 321-327
    • Baba, A.1    Dobsak, P.2    Saito, I.3    Isoyama, T.4    Takiura, K.5    Abe, Y.6    Chinzei, T.7    Vasku, J.8    Imachi, K.9
  • 15
    • 33744967067 scopus 로고    scopus 로고
    • Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: A feasibility study
    • O.H. Frazier E. Tuzun W.E. Cohn J.L. Conger K.A. Kadipasaoglu 2006 Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: a feasibility study ASAIO J 52 145 149
    • (2006) ASAIO J , vol.52 , pp. 145-149
    • Frazier, O.H.1    Tuzun, E.2    Cohn, W.E.3    Conger, J.L.4    Kadipasaoglu, K.A.5
  • 20
    • 0030036571 scopus 로고    scopus 로고
    • Can we develop a nonpulsatile permanent rotary blood pump? Yes, we can
    • Y. Nose K. Kawahito T. Nakazawa 1996 Can we develop a nonpulsatile permanent rotary blood pump? Yes, we can Artif Organs 20 467 474
    • (1996) Artif Organs , vol.20 , pp. 467-474
    • Nose, Y.1    Kawahito, K.2    Nakazawa, T.3
  • 21
    • 0022486563 scopus 로고
    • Arterial pressure pulsation during nonpulsatile biventricular bypass experiments: Possible idioperipheral pulsation
    • T. Tsutui Y. Nose 1986 Arterial pressure pulsation during nonpulsatile biventricular bypass experiments: possible idioperipheral pulsation Artif Organs 10 153 155
    • (1986) Artif Organs , vol.10 , pp. 153-155
    • Tsutui, T.1    Nose, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.