메뉴 건너뛰기




Volumn 11, Issue 2, 2008, Pages 60-66

Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: Synchronized analysis between visual images and pressure signals

Author keywords

Cavitation; Mechanical heart valve; Pneumatic ventricular assist device

Indexed keywords

ARTICLE; ARTIFICIAL HEART; ASSISTED CIRCULATION; CAMERA; COMPARATIVE STUDY; DIGITAL FILTERING; HEART ASSIST DEVICE; HEART VALVE PROSTHESIS; IMAGE ANALYSIS; OSCILLOSCOPE; PNEUMATIC VENTRICULAR ASSIST DEVICE; PRESSURE; PRIORITY JOURNAL; R WAVE; SENSOR; TIME; VELOCITY;

EID: 46749134309     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-008-0408-5     Document Type: Article
Times cited : (7)

References (19)
  • 1
    • 29844458743 scopus 로고    scopus 로고
    • Flow in prosthetic heart valves: State-of-the-art and future directions
    • 12
    • Yoganathan AP, Chandran KB, Sotiropoulos F. Flow in prosthetic heart valves: state-of-the-art and future directions. Ann Biomed Eng 2005;33(12):1689-1694
    • (2005) Ann Biomed Eng , vol.33 , pp. 1689-1694
    • Yoganathan, A.P.1    Chandran, K.B.2    Sotiropoulos, F.3
  • 2
    • 0003731071 scopus 로고
    • Institute of Hydraulic Research, University of Iowa Iowa City
    • Knapp RT, Daily JW, Hammitt FG. Cavitation. Iowa City: Institute of Hydraulic Research, University of Iowa. 1979
    • (1979) Cavitation
    • Knapp, R.T.1    Daily, J.W.2    Hammitt, F.G.3
  • 4
    • 0033213797 scopus 로고    scopus 로고
    • A discussion on the threshold limit for hemolysis related to Reynolds shear stress
    • Grigioni M, Daniele C, D'Avenio G, Barbaro V. A discussion on the threshold limit for hemolysis related to Reynolds shear stress. J Biomech 1999;32:1107-1112
    • (1999) J Biomech , vol.32 , pp. 1107-1112
    • Grigioni, M.1    Daniele, C.2    D'Avenio, G.3    Barbaro, V.4
  • 8
    • 12844253699 scopus 로고    scopus 로고
    • Statistical correlation between transient pressure drop and cavitation at closure of a mechanical heart valve
    • Wu C, Liu JS, Hwang NHC, Lin YKM. Statistical correlation between transient pressure drop and cavitation at closure of a mechanical heart valve. ASAIO J 2005;51:11-16
    • (2005) ASAIO J , vol.51 , pp. 11-16
    • Wu, C.1    Liu, J.S.2    Hwang, N.H.C.3    Lin, Y.K.M.4
  • 9
    • 26444461282 scopus 로고    scopus 로고
    • Effect of the diastolic and systolic duration on valve cavitation in a pediatric pulsatile ventricular assist device
    • Lukic B, Zapanta CM, Griffith KA, Weiss WJ. Effect of the diastolic and systolic duration on valve cavitation in a pediatric pulsatile ventricular assist device. ASAIO J 2005;51:546-550
    • (2005) ASAIO J , vol.51 , pp. 546-550
    • Lukic, B.1    Zapanta, C.M.2    Griffith, K.A.3    Weiss, W.J.4
  • 13
    • 33644653805 scopus 로고    scopus 로고
    • Acoustic and visual characteristic of cavitation induced by mechanical heart valves
    • Sohn K, Manning KB, Fontaine AA, Tarbell JM, Deutsch S. Acoustic and visual characteristic of cavitation induced by mechanical heart valves. J Heart Valve Dis 2005;14:551-558
    • (2005) J Heart Valve Dis , vol.14 , pp. 551-558
    • Sohn, K.1    Manning, K.B.2    Fontaine, A.A.3    Tarbell, J.M.4    Deutsch, S.5
  • 14
    • 0029895945 scopus 로고    scopus 로고
    • Fatigue and fracture of pyrolytic carbon: A damagetolerant approach to structural integrity and life prediction in ceramic heart valve prostheses
    • SupplI
    • Ritchie RO. Fatigue and fracture of pyrolytic carbon: a damagetolerant approach to structural integrity and life prediction in ceramic heart valve prostheses. J Heart Valve Dis 1996;5(Suppl I):S9-S31
    • (1996) J Heart Valve Dis , vol.5
    • Ritchie, R.O.1
  • 15
    • 34250776505 scopus 로고    scopus 로고
    • Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: Cavitation and closing velocity
    • 7
    • Lee HS, Homma A, Taenaka Y. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity. Artif Organs 2007;31(7):532-537
    • (2007) Artif Organs , vol.31 , pp. 532-537
    • Lee, H.S.1    Homma, A.2    Taenaka, Y.3
  • 17
    • 13544251735 scopus 로고    scopus 로고
    • Mechanical heart valve cavitation
    • 1
    • Johansen P. Mechanical heart valve cavitation. Expert Rev Med Devices 2004;1(1):95-104
    • (2004) Expert Rev Med Devices , vol.1 , pp. 95-104
    • Johansen, P.1
  • 18
    • 38349176290 scopus 로고    scopus 로고
    • Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: Using a monoleaflet valve
    • 1
    • Lee HS, Tatsumi E, Taenaka Y. Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: using a monoleaflet valve. ASAIO J 2008;54(1):25-30
    • (2008) ASAIO J , vol.54 , pp. 25-30
    • Lee, H.S.1    Tatsumi, E.2    Taenaka, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.