메뉴 건너뛰기




Volumn 26, Issue 1, 2009, Pages 10-16

Imaging surveillance following endovascular aneurysm repair

Author keywords

Angiography; Computed tomography; Endoleak; Endovascular aneurysm repair; Magnetic resonance imaging; Ultrasound

Indexed keywords


EID: 63149160635     PISSN: 07399529     EISSN: 10988963     Source Type: Journal    
DOI: 10.1055/s-0029-1208378     Document Type: Review
Times cited : (33)

References (40)
  • 1
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491-499
    • (1991) Ann Vasc Surg , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 2
    • 4544298467 scopus 로고    scopus 로고
    • Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: Randomised controlled trial
    • Greenhalgh RM, Brown LC, Kwong GP, Powell JT, Thompson SG. Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial. Lancet 2004;364:843-848
    • (2004) Lancet , vol.364 , pp. 843-848
    • Greenhalgh, R.M.1    Brown, L.C.2    Kwong, G.P.3    Powell, J.T.4    Thompson, S.G.5
  • 3
    • 38749127156 scopus 로고    scopus 로고
    • Endovascular vs. open repair of abdominal aortic aneurysms in the Medicare population
    • Schermerhorn ML, O'Malley AJ, Jhaveri A, et al. Endovascular vs. open repair of abdominal aortic aneurysms in the Medicare population. N Engl J Med 2008;358:464-474
    • (2008) N Engl J Med , vol.358 , pp. 464-474
    • Schermerhorn, M.L.1    O'Malley, A.J.2    Jhaveri, A.3
  • 4
    • 19044368230 scopus 로고    scopus 로고
    • Veith FJ, Baum RA, Ohki T, et al. Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. J Vasc Surg 2002;35:1029-1035
    • Veith FJ, Baum RA, Ohki T, et al. Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. J Vasc Surg 2002;35:1029-1035
  • 5
    • 3042697432 scopus 로고    scopus 로고
    • Imaging modalities for the detection and management of endoleaks
    • Stavropoulos SW, Baum RA. Imaging modalities for the detection and management of endoleaks. Semin Vasc Surg 2004;17:154-160
    • (2004) Semin Vasc Surg , vol.17 , pp. 154-160
    • Stavropoulos, S.W.1    Baum, R.A.2
  • 6
    • 58149293543 scopus 로고    scopus 로고
    • Aneurysm rupture after EVAR: Can the ultimate failure be predicted?
    • Schlosser FJ, Gusberg RJ, Dardik A, et al. Aneurysm rupture after EVAR: can the ultimate failure be predicted? Eur J Vasc Endovasc Surg 2009;37:15-22
    • (2009) Eur J Vasc Endovasc Surg , vol.37 , pp. 15-22
    • Schlosser, F.J.1    Gusberg, R.J.2    Dardik, A.3
  • 8
    • 0347447282 scopus 로고    scopus 로고
    • Follow-up after endovascular aortic aneurysm repair: The plain radiograph has an essential role in surveillance
    • Fearn S, Lawrence-Brown MMD, Semmens JB, Hartley D. Follow-up after endovascular aortic aneurysm repair: the plain radiograph has an essential role in surveillance. J Endovasc Ther 2003;10:894-901
    • (2003) J Endovasc Ther , vol.10 , pp. 894-901
    • Fearn, S.1    Lawrence-Brown, M.M.D.2    Semmens, J.B.3    Hartley, D.4
  • 9
    • 0348077423 scopus 로고    scopus 로고
    • Migration versus apparent migration: Importance of errors due to positioning variation in plain radiographic follow-up of aortic stent-grafts
    • Hodgson R, McWilliams RG, Simpson A, et al. Migration versus apparent migration: importance of errors due to positioning variation in plain radiographic follow-up of aortic stent-grafts. J Endovasc Ther 2003;10:902-910
    • (2003) J Endovasc Ther , vol.10 , pp. 902-910
    • Hodgson, R.1    McWilliams, R.G.2    Simpson, A.3
  • 10
    • 0346816493 scopus 로고    scopus 로고
    • Plain radiographic surveillance of abdominal aortic stent-grafts: The Liverpool/Perth protocol
    • Murphy M, Hodgson R, Harris PL, et al. Plain radiographic surveillance of abdominal aortic stent-grafts: the Liverpool/Perth protocol. J Endovasc Ther 2003;10:911-912
    • (2003) J Endovasc Ther , vol.10 , pp. 911-912
    • Murphy, M.1    Hodgson, R.2    Harris, P.L.3
  • 11
    • 63149131679 scopus 로고    scopus 로고
    • Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: A comparison with computed tomography aortography
    • September 30 Epub ahead of print
    • Manning BJ, O'Neill SM, Haider SN, et al. Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography. J Vasc Surg 2008; September 30 (Epub ahead of print)
    • (2008) J Vasc Surg
    • Manning, B.J.1    O'Neill, S.M.2    Haider, S.N.3
  • 12
    • 0037329016 scopus 로고    scopus 로고
    • Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts
    • Bendick PJ, Bove PG, Long GW, et al. Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg 2003;37:381-385
    • (2003) J Vasc Surg , vol.37 , pp. 381-385
    • Bendick, P.J.1    Bove, P.G.2    Long, G.W.3
  • 13
    • 33750515636 scopus 로고    scopus 로고
    • Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: Preliminary experience
    • Carrafiello G, Lagana D, Recaldini C, et al. Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience. Cardiovasc Intervent Radiol 2006;29:969-974
    • (2006) Cardiovasc Intervent Radiol , vol.29 , pp. 969-974
    • Carrafiello, G.1    Lagana, D.2    Recaldini, C.3
  • 14
    • 26944486193 scopus 로고    scopus 로고
    • Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts
    • AbuRahma AF, Welch CA, Mullins BB, Dyer B. Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts. J Endovasc Ther 2005;12:568-573
    • (2005) J Endovasc Ther , vol.12 , pp. 568-573
    • AbuRahma, A.F.1    Welch, C.A.2    Mullins, B.B.3    Dyer, B.4
  • 15
    • 20444485179 scopus 로고    scopus 로고
    • Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review
    • Ashoke R, Brown LC, Rodway A, et al. Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review. J Endovasc Ther 2005;12:297-305
    • (2005) J Endovasc Ther , vol.12 , pp. 297-305
    • Ashoke, R.1    Brown, L.C.2    Rodway, A.3
  • 16
    • 0036182773 scopus 로고    scopus 로고
    • Evaluation of abdominal aortic aneurysm after endoluminal treatment: Comparison of color Doppler sonography with biphasic helical CT
    • Golzarian J, Murgo S, Dussaussois L, et al. Evaluation of abdominal aortic aneurysm after endoluminal treatment: comparison of color Doppler sonography with biphasic helical CT. AJR Am J Roentgenol 2002;178:623-628
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 623-628
    • Golzarian, J.1    Murgo, S.2    Dussaussois, L.3
  • 17
    • 0035145546 scopus 로고    scopus 로고
    • Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: Validation with computed tomography
    • d'Audiffret A, Desgranges P, Kobeiter DH, Becquemin JP. Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: validation with computed tomography. J Vasc Surg 2001;33:42-49
    • (2001) J Vasc Surg , vol.33 , pp. 42-49
    • d'Audiffret, A.1    Desgranges, P.2    Kobeiter, D.H.3    Becquemin, J.P.4
  • 18
    • 2542436963 scopus 로고    scopus 로고
    • Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm
    • Elkouri S, Panneton JM, Andrews JC, et al. Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm. Ann Vasc Surg 2004;18:271-279
    • (2004) Ann Vasc Surg , vol.18 , pp. 271-279
    • Elkouri, S.1    Panneton, J.M.2    Andrews, J.C.3
  • 19
    • 4644350819 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair
    • Napoli V, Bargellini I, Sardella SG, et al. Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 2004;233:217-225
    • (2004) Radiology , vol.233 , pp. 217-225
    • Napoli, V.1    Bargellini, I.2    Sardella, S.G.3
  • 20
    • 0038417019 scopus 로고    scopus 로고
    • MR imaging for the detection of endoleaks in recipients of abdominal aortic stent-grafts with low magnetic susceptibility
    • Insko EK, Kulzer LM, Fairman RM, Carpenter JP, Stavropoulos SW. MR imaging for the detection of endoleaks in recipients of abdominal aortic stent-grafts with low magnetic susceptibility. Acad Radiol 2003;10:509-513
    • (2003) Acad Radiol , vol.10 , pp. 509-513
    • Insko, E.K.1    Kulzer, L.M.2    Fairman, R.M.3    Carpenter, J.P.4    Stavropoulos, S.W.5
  • 22
    • 0036781469 scopus 로고    scopus 로고
    • MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms
    • Cejna M, Loewe C, Schoder M, et al. MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. Eur Radiol 2002;12:2443-2450
    • (2002) Eur Radiol , vol.12 , pp. 2443-2450
    • Cejna, M.1    Loewe, C.2    Schoder, M.3
  • 23
    • 7044227734 scopus 로고    scopus 로고
    • MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses
    • Ayuso JR, de Caralt TM, Pages M, et al. MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses. J Magn Reson Imaging 2004;20:803-810
    • (2004) J Magn Reson Imaging , vol.20 , pp. 803-810
    • Ayuso, J.R.1    de Caralt, T.M.2    Pages, M.3
  • 24
    • 0346964280 scopus 로고    scopus 로고
    • Time-resolved magnetic resonance angiography as a noninvasive method to characterize endoleaks: Initial results compared with conventional angiography
    • Lookstein RA, Goldman J, Pukin L, Marin ML. Time-resolved magnetic resonance angiography as a noninvasive method to characterize endoleaks: initial results compared with conventional angiography. J Vasc Surg 2004;39:27-33
    • (2004) J Vasc Surg , vol.39 , pp. 27-33
    • Lookstein, R.A.1    Goldman, J.2    Pukin, L.3    Marin, M.L.4
  • 25
    • 45849085429 scopus 로고    scopus 로고
    • Time-resolved MR angiography for the classification of endoleaks after endovascular aneurysm repair
    • Cohen EI, Weinreb D, Siegelbaum R, et al. Time-resolved MR angiography for the classification of endoleaks after endovascular aneurysm repair. J Magn Reson Imaging 2008;27:500-503
    • (2008) J Magn Reson Imaging , vol.27 , pp. 500-503
    • Cohen, E.I.1    Weinreb, D.2    Siegelbaum, R.3
  • 26
    • 0034071614 scopus 로고    scopus 로고
    • Aortic aneurysmal disease: Assessment of stent-graft treatment - CT versus conventional angiography
    • Armerding MD, Rubin GD, Beaulieu CF, et al. Aortic aneurysmal disease: assessment of stent-graft treatment - CT versus conventional angiography. Radiology 2000;215:138-146
    • (2000) Radiology , vol.215 , pp. 138-146
    • Armerding, M.D.1    Rubin, G.D.2    Beaulieu, C.F.3
  • 27
    • 0037407663 scopus 로고    scopus 로고
    • Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: Value of unenhanced and delayed helical CT acquisitions
    • Rozenblit AM, Patlas M, Rosenbaum AT, et al. Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions. Radiology 2003;227:426-433
    • (2003) Radiology , vol.227 , pp. 426-433
    • Rozenblit, A.M.1    Patlas, M.2    Rosenbaum, A.T.3
  • 28
    • 33846674463 scopus 로고    scopus 로고
    • Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: Are unenhanced and delayed phase enhanced images effective for endoleak detection?
    • Iezzi R, Cotroneo AR, Filippone A, et al. Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? Radiology 2006;241:915-921
    • (2006) Radiology , vol.241 , pp. 915-921
    • Iezzi, R.1    Cotroneo, A.R.2    Filippone, A.3
  • 29
    • 49949085905 scopus 로고    scopus 로고
    • Multidetector-row computed tomography angiography in abdominal aortic aneurysm treated with endovascular repair: Evaluation of optimal timing of delayed phase imaging for the detection of low-flow endoleaks
    • Iezzi R, Cotroneo AR, Filippone A, et al. Multidetector-row computed tomography angiography in abdominal aortic aneurysm treated with endovascular repair: evaluation of optimal timing of delayed phase imaging for the detection of low-flow endoleaks. J Comput Assist Tomogr 2008;32:609-615
    • (2008) J Comput Assist Tomogr , vol.32 , pp. 609-615
    • Iezzi, R.1    Cotroneo, A.R.2    Filippone, A.3
  • 30
    • 26844572831 scopus 로고    scopus 로고
    • Recurrent endoleak detection and measurement of aneurysm size with CTA after coil embolization of endoleaks
    • Stavropoulos SW, Marin H, Fairman RM, et al. Recurrent endoleak detection and measurement of aneurysm size with CTA after coil embolization of endoleaks. J Vasc Interv Radiol 2005;16:1313-1317
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 1313-1317
    • Stavropoulos, S.W.1    Marin, H.2    Fairman, R.M.3
  • 31
    • 56149119702 scopus 로고    scopus 로고
    • Abdominal aorta: Evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms - initial observations
    • Chandarana H, Godoy MCB, Vlahos I, et al. Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms - initial observations. Radiology 2008;249:692-700
    • (2008) Radiology , vol.249 , pp. 692-700
    • Chandarana, H.1    Godoy, M.C.B.2    Vlahos, I.3
  • 32
    • 56149116093 scopus 로고    scopus 로고
    • Endoleaks after endovascular abdominal aortic aneurysm repair: Detection with dual-energy dual-source CT
    • Stolzmann P, Frauenfelder T, Pfammatter T, et al. Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 2008;249:682-691
    • (2008) Radiology , vol.249 , pp. 682-691
    • Stolzmann, P.1    Frauenfelder, T.2    Pfammatter, T.3
  • 33
    • 33846667184 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm: Can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose?
    • Macari M, Chandarana H, Schmidt B, et al. Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? Radiology 2006;241:908-914
    • (2006) Radiology , vol.241 , pp. 908-914
    • Macari, M.1    Chandarana, H.2    Schmidt, B.3
  • 34
    • 18444384843 scopus 로고    scopus 로고
    • Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms
    • Stavropoulos SW, Clark TWI, Carpenter JP, et al. Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol 2005;16:663-667
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 663-667
    • Stavropoulos, S.W.1    Clark, T.W.I.2    Carpenter, J.P.3
  • 35
    • 33751293106 scopus 로고    scopus 로고
    • Detection of endoleaks after endovascular aneurysm repair with use of technetium-99m sulfur colloid and Tc-99m-labeled red blood cell scans
    • Stavropoulos SW, Itkin M, Lakhani P, et al. Detection of endoleaks after endovascular aneurysm repair with use of technetium-99m sulfur colloid and Tc-99m-labeled red blood cell scans. J Vasc Interv Radiol 2006;17:1739-1743
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 1739-1743
    • Stavropoulos, S.W.1    Itkin, M.2    Lakhani, P.3
  • 36
    • 0032797283 scopus 로고    scopus 로고
    • Tc-99m sulfur colloid scintigraphy for detecting perigraft flow following endovascular aortic aneurysm repair: A feasibility study
    • Hovsepian DM, Siegel BA, Kimbiris G, et al. Tc-99m sulfur colloid scintigraphy for detecting perigraft flow following endovascular aortic aneurysm repair: a feasibility study. Cardiovasc Intervent Radiol 1999;22:447-451
    • (1999) Cardiovasc Intervent Radiol , vol.22 , pp. 447-451
    • Hovsepian, D.M.1    Siegel, B.A.2    Kimbiris, G.3
  • 37
    • 43249122720 scopus 로고    scopus 로고
    • Aneurysm Sac pressure measurement with minimally invasive implantable pressure sensors: An alternative to current surveillance regimes after EVAR?
    • Springer F, Gunther RW, Schmitz-Rode T. Aneurysm Sac pressure measurement with minimally invasive implantable pressure sensors: an alternative to current surveillance regimes after EVAR? Cardiovasc Intervent Radiol 2008;31:460-467
    • (2008) Cardiovasc Intervent Radiol , vol.31 , pp. 460-467
    • Springer, F.1    Gunther, R.W.2    Schmitz-Rode, T.3
  • 38
    • 41949130176 scopus 로고    scopus 로고
    • Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: An in vitro study
    • Springer F, Schlierf R, Pfeffer JG, et al. Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study. Eur Radiol 2007;17:2589-2597
    • (2007) Eur Radiol , vol.17 , pp. 2589-2597
    • Springer, F.1    Schlierf, R.2    Pfeffer, J.G.3
  • 39
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • Harris PL, Vallabhaneni SR, Desgranges P, et al. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. J Vasc Surg 2000;32:739-749
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3
  • 40
    • 43249114384 scopus 로고    scopus 로고
    • Endovascular aneurysm repair: Current and future status
    • Hinchliffe RJ, Ivancev K. Endovascular aneurysm repair: current and future status. Cardiovasc Intervent Radiol 2008;31:451-459
    • (2008) Cardiovasc Intervent Radiol , vol.31 , pp. 451-459
    • Hinchliffe, R.J.1    Ivancev, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.