메뉴 건너뛰기




Volumn 32, Issue 4, 2008, Pages 609-615

Multidetector-row computed tomography angiography in abdominal aortic aneurysm treated with endovascular repair: Evaluation of optimal timing of delayed phase imaging for the detection of low-flow endoleaks

Author keywords

Aneurysm; Aorta; Aortic; Computed tomography; CT; Grafts; Interventional procedures; Late phase imaging

Indexed keywords

CONTRAST MEDIA; DIAGNOSIS; MULTIDETECTOR COMPUTED TOMOGRAPHY; PATIENT TREATMENT; REPAIR; TIMING CIRCUITS;

EID: 49949085905     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/RCT.0b013e31814b271d     Document Type: Article
Times cited : (44)

References (32)
  • 1
    • 0008212787 scopus 로고    scopus 로고
    • Realistic expectations for patients with stent-graft treatment of abdominal aortic aneurysms. Results of a European multicentre registry
    • 19 99;17:507-516
    • Cuypers P, Buth J, Harris PL, et al. Realistic expectations for patients with stent-graft treatment of abdominal aortic aneurysms. Results of a European multicentre registry. Eur J Vasc Endovasc Surg. 19 99;17:507-516.
    • Eur J Vasc Endovasc Surg
    • Cuypers, P.1    Buth, J.2    Harris, P.L.3
  • 2
    • 0033360826 scopus 로고    scopus 로고
    • Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention
    • Gilling-Smith G, Brennan J, Harris P, et al. Endotension after endovascular aneurysm repair: definition, classification, and strategies for surveillance and intervention. J Endovasc Surg. 1999;6:305-307.
    • (1999) J Endovasc Surg , vol.6 , pp. 305-307
    • Gilling-Smith, G.1    Brennan, J.2    Harris, P.3
  • 3
    • 0031056971 scopus 로고    scopus 로고
    • Endovascular aortic stent-grafts: Transcatheter embolization of persistent perigraft leaks
    • Golzarian J, Struyven J, Abada HT, et al. Endovascular aortic stent-grafts: transcatheter embolization of persistent perigraft leaks. Radiology. 1997;202:731-734.
    • (1997) Radiology , vol.202 , pp. 731-734
    • Golzarian, J.1    Struyven, J.2    Abada, H.T.3
  • 4
    • 0345073276 scopus 로고    scopus 로고
    • Leakages after endovascular repair of aortic aneurysms: Classification based on findings at CT, angiography, and radiography
    • Gorich J, Rilinger N, Sokiranski R, et al. Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography. Radiology. 1999;213:767-772.
    • (1999) Radiology , vol.213 , pp. 767-772
    • Gorich, J.1    Rilinger, N.2    Sokiranski, R.3
  • 5
    • 0034235048 scopus 로고    scopus 로고
    • Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial
    • Zarins CK, White RA, Hodgson KJ, et al. Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial. J Vasc Surg. 2000;32:90-107.
    • (2000) J Vasc Surg , vol.32 , pp. 90-107
    • Zarins, C.K.1    White, R.A.2    Hodgson, K.J.3
  • 6
    • 0029133971 scopus 로고
    • Delayed rupture of aortic aneurysms following endovascular stent grafting
    • Lumsden AB, Allen RC, Chaikof EL, et al. Delayed rupture of aortic aneurysms following endovascular stent grafting. Am J Surg. 1995;170: 174-178.
    • (1995) Am J Surg , vol.170 , pp. 174-178
    • Lumsden, A.B.1    Allen, R.C.2    Chaikof, E.L.3
  • 7
    • 0034972381 scopus 로고    scopus 로고
    • Lessons learnt from the EUROSTAR registry on endovascular repair of abdominal aneurysm repair
    • Vallabhaneni SR, Harris PL. Lessons learnt from the EUROSTAR registry on endovascular repair of abdominal aneurysm repair. Eur J Radiol. 2001;39:34-41.
    • (2001) Eur J Radiol , vol.39 , pp. 34-41
    • Vallabhaneni, S.R.1    Harris, P.L.2
  • 8
    • 0035116961 scopus 로고    scopus 로고
    • Is proximal aortic neck dilatation after endovascular aneurysm exclusion a cause for concern?
    • Makaroun MS, Deaton DH. Is proximal aortic neck dilatation after endovascular aneurysm exclusion a cause for concern? J Vasc Surg. 2001;33:39-45.
    • (2001) J Vasc Surg , vol.33 , pp. 39-45
    • Makaroun, M.S.1    Deaton, D.H.2
  • 9
    • 19044368230 scopus 로고    scopus 로고
    • Nature and significance of endoleaks and endotension: Summary of opinions expressed at an international conference
    • Veith FJ, Baum RA, Ohki T, et al. Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. J Vasc Surg. 2002;35:1029-1035.
    • (2002) J Vasc Surg , vol.35 , pp. 1029-1035
    • Veith, F.J.1    Baum, R.A.2    Ohki, T.3
  • 10
    • 0141748303 scopus 로고    scopus 로고
    • Endoleaks after endovascular repair of abdominal aortic aneurysms
    • Baum RA, Stavropoulos SW, Carpenter JP. Endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol. 2003;14: 1111-1117.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 1111-1117
    • Baum, R.A.1    Stavropoulos, S.W.2    Carpenter, J.P.3
  • 11
    • 4644350819 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair
    • Napoli V, Bargellini I, Sardella SG, et al. Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology. 2004;233:217-225.
    • (2004) Radiology , vol.233 , pp. 217-225
    • Napoli, V.1    Bargellini, I.2    Sardella, S.G.3
  • 12
    • 0031872430 scopus 로고    scopus 로고
    • Helical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition
    • Golzarian J, Dussaussois L, Abada HT, et al. Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR Am J Roentgenol. 1998;171:329-331.
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 329-331
    • Golzarian, J.1    Dussaussois, L.2    Abada, H.T.3
  • 13
    • 0028845144 scopus 로고
    • Endovascular repair of abdominal aortic aneurysm: Value of postoperative follow-up with helical CT
    • Rozenblit A, Marin ML, Veith FJ, et al. Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up with helical CT. AJR Am J Roentgenol. 1995;165:1473-1479.
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 1473-1479
    • Rozenblit, A.1    Marin, M.L.2    Veith, F.J.3
  • 14
    • 0037407663 scopus 로고    scopus 로고
    • Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: Value of unenhanced and delayed helical CT acquisitions
    • Rozenblit A, Patlas M, Rosenbaum AT, et al. Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions. Radiology. 2003;227:426-433.
    • (2003) Radiology , vol.227 , pp. 426-433
    • Rozenblit, A.1    Patlas, M.2    Rosenbaum, A.T.3
  • 15
    • 0034976858 scopus 로고    scopus 로고
    • Analysis of initial CT findings after endovascular repair of abdominal aortic aneurysm
    • Sawhney R, Kerlan RK, Wall SD, et al. Analysis of initial CT findings after endovascular repair of abdominal aortic aneurysm. Radiology. 2001;220:157-160.
    • (2001) Radiology , vol.220 , pp. 157-160
    • Sawhney, R.1    Kerlan, R.K.2    Wall, S.D.3
  • 16
    • 0031006742 scopus 로고    scopus 로고
    • Spiral CT angiography in the assessment of abdominal aortic aneurysms after stent grafting: Value of maximum intensity projections
    • Dorffner R, Thurnher S, Youssefzadeh S, et al. Spiral CT angiography in the assessment of abdominal aortic aneurysms after stent grafting: value of maximum intensity projections. J Comput Assist Tomogr. 1997;21: 472-477.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 472-477
    • Dorffner, R.1    Thurnher, S.2    Youssefzadeh, S.3
  • 17
    • 0034974385 scopus 로고    scopus 로고
    • Endoluminal repair of abdominal aortic aneurysms - state of the art
    • May J, White GH, Harris JP. Endoluminal repair of abdominal aortic aneurysms - state of the art. Eur J Radiol. 2001;39:16-21.
    • (2001) Eur J Radiol , vol.39 , pp. 16-21
    • May, J.1    White, G.H.2    Harris, J.P.3
  • 18
    • 0348109333 scopus 로고    scopus 로고
    • Delayed helical CT acquisition in the detection of endoleak
    • Golzarian J. Delayed helical CT acquisition in the detection of endoleak. Radiology. 2004;230:299-300.
    • (2004) Radiology , vol.230 , pp. 299-300
    • Golzarian, J.1
  • 19
    • 0030947672 scopus 로고    scopus 로고
    • Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: Classification, incidence, diagnosis, and management
    • White GH, Yu W, May J, et al. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg. 1997;4: 152-168.
    • (1997) J Endovasc Surg , vol.4 , pp. 152-168
    • White, G.H.1    Yu, W.2    May, J.3
  • 20
    • 0031647176 scopus 로고    scopus 로고
    • Type III and type IVendoleak: Toward a complete definition of blood flow in the sac after endoluminal AAA repair
    • White GH, May J, Waugh RC, et al. Type III and type IVendoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg. 1998;5:305-309.
    • (1998) J Endovasc Surg , vol.5 , pp. 305-309
    • White, G.H.1    May, J.2    Waugh, R.C.3
  • 21
    • 0033364198 scopus 로고    scopus 로고
    • Endotension: An explanation for continued AAA growth after successful endoluminal repair
    • White GH, May J, Petrasek P, et al. Endotension: an explanation for continued AAA growth after successful endoluminal repair. J Endovasc Surg. 1999;6:308-315.
    • (1999) J Endovasc Surg , vol.6 , pp. 308-315
    • White, G.H.1    May, J.2    Petrasek, P.3
  • 22
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86:420-428.
    • (1979) Psychol Bull , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 23
    • 0141518516 scopus 로고    scopus 로고
    • Receiver operating characteristic curves and their use in radiology
    • Obuchowski NA. Receiver operating characteristic curves and their use in radiology. Radiology. 2003;229:3-8.
    • (2003) Radiology , vol.229 , pp. 3-8
    • Obuchowski, N.A.1
  • 24
    • 2342446592 scopus 로고    scopus 로고
    • Receiver operating characteristic (ROC) curve: Practical review for radiologists
    • Park S, Goo JMG, Jo C-H. Receiver operating characteristic (ROC) curve: practical review for radiologists. Korean J Radiol. 2004;5: 11-18.
    • (2004) Korean J Radiol , vol.5 , pp. 11-18
    • Park, S.1    Goo, J.M.G.2    Jo, C.-H.3
  • 25
    • 0022470978 scopus 로고
    • ROC methodology in radiologic imaging
    • Metz CE. ROC methodology in radiologic imaging. Invest Radiol. 1986;21:720-733.
    • (1986) Invest Radiol , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 26
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • De Long ER, De Long DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44:837-844.
    • (1988) Biometrics , vol.44 , pp. 837-844
    • De Long, E.R.1    De Long, D.M.2    Clarke-Pearson, D.L.3
  • 28
    • 0032992669 scopus 로고    scopus 로고
    • Longitudinal aneurysm shrinkage following endovascular aortic aneurysm repair: A source of intermediate and late complications
    • Harris P, Brennan J, Martin J, et al. Longitudinal aneurysm shrinkage following endovascular aortic aneurysm repair: a source of intermediate and late complications. J Endovasc Surg. 1999;6:11-16.
    • (1999) J Endovasc Surg , vol.6 , pp. 11-16
    • Harris, P.1    Brennan, J.2    Martin, J.3
  • 29
    • 0035107335 scopus 로고    scopus 로고
    • Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection
    • Hittmair K, Fleischmann D. Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection. J Comput Assist Tomogr. 2001;25:287-294.
    • (2001) J Comput Assist Tomogr , vol.25 , pp. 287-294
    • Hittmair, K.1    Fleischmann, D.2
  • 30
    • 33846674463 scopus 로고    scopus 로고
    • Multidetector-row CT in abdominal aortic aneurysm treated with endovascular repair: Are unenhanced and delayed phase enhanced images really effective for endoleak detection?
    • Iezzi R, Cotroneo AR, Filippone A, et al. Multidetector-row CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images really effective for endoleak detection? Radiology. 2006;241:915-921.
    • (2006) Radiology , vol.241 , pp. 915-921
    • Iezzi, R.1    Cotroneo, A.R.2    Filippone, A.3
  • 31
    • 33846667184 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm: Can the arterial phase at CT evaluation after endovascular be eliminated to reduce radiation dose?
    • Macari M, Chandarana H, Schmidt B, et al. Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular be eliminated to reduce radiation dose? Radiology. 2006;241:908-914.
    • (2006) Radiology , vol.241 , pp. 908-914
    • Macari, M.1    Chandarana, H.2    Schmidt, B.3
  • 32
    • 35348983089 scopus 로고    scopus 로고
    • Endoleakage after endovascular treatment of abdominal aortic aneurysms: Diagnosis, significance and treatment
    • Golzarian J, Valenti D. Endoleakage after endovascular treatment of abdominal aortic aneurysms: diagnosis, significance and treatment. Eur Radiol. 2006;16:2849-2857.
    • (2006) Eur Radiol , vol.16 , pp. 2849-2857
    • Golzarian, J.1    Valenti, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.