메뉴 건너뛰기




Volumn 457, Issue 6, 2009, Pages 1415-1422

Glass microneedles for force measurements: A finite-element analysis model

Author keywords

Calibration; Cellular force probe; FEA simulation; Frequency response; Myofibril kinetics

Indexed keywords

ARTICLE; FINITE ELEMENT ANALYSIS; GLASS MICRONEEDLE; MATHEMATICAL PARAMETERS; MUSCLE FIBRIL; MUSCLE FORCE; MUSCLE STIFFNESS; NEEDLE; PRIORITY JOURNAL;

EID: 62549106588     PISSN: 00316768     EISSN: 14322013     Source Type: Journal    
DOI: 10.1007/s00424-008-0605-3     Document Type: Article
Times cited : (25)

References (13)
  • 1
    • 0024596709 scopus 로고
    • Simultaneous recordings of force and sliding movement between a myosin-coated glass microneedle and actin cables in vitro
    • S Chaen K Oiwa T Shimmen H Iwamoto H Sugi 1989 Simultaneous recordings of force and sliding movement between a myosin-coated glass microneedle and actin cables in vitro Proc Natl Acad Sci U S A 86 1510 1514
    • (1989) Proc Natl Acad Sci U S A , vol.86 , pp. 1510-1514
    • Chaen, S.1    Oiwa, K.2    Shimmen, T.3    Iwamoto, H.4    Sugi, H.5
  • 2
    • 3042568780 scopus 로고    scopus 로고
    • Calibration of AFM cantilever stiffness: A microfabricated array of reflective springs
    • PJ Cumpson P Zhdan J Hedley 2004 Calibration of AFM cantilever stiffness: a microfabricated array of reflective springs Ultramicroscopy 100 241 251
    • (2004) Ultramicroscopy , vol.100 , pp. 241-251
    • Cumpson, P.J.1    Zhdan, P.2    Hedley, J.3
  • 5
    • 0030031120 scopus 로고    scopus 로고
    • Multiple- and single-molecule analysis of the actomyosin motor by nanometer piconewton manipulation with a microneedle: Unitary steps and forces
    • A Ishijima H Kojima H Higuchi Y Harada T Funatsu T Yanagida 1996 Multiple- and single-molecule analysis of the actomyosin motor by nanometer piconewton manipulation with a microneedle: unitary steps and forces Biophys J 70 383 400
    • (1996) Biophys J , vol.70 , pp. 383-400
    • Ishijima, A.1    Kojima, H.2    Higuchi, H.3    Harada, Y.4    Funatsu, T.5    Yanagida, T.6
  • 7
    • 0023919181 scopus 로고
    • Force measurements by micromanipulation of a single actin filament by glass needles
    • A Kishino T Yanagida 1988 Force measurements by micromanipulation of a single actin filament by glass needles Nature 334 74 76
    • (1988) Nature , vol.334 , pp. 74-76
    • Kishino, A.1    Yanagida, T.2
  • 8
    • 17444431193 scopus 로고    scopus 로고
    • Sarcomeric determinants of striated muscle relaxation kinetics
    • C Poggesi C Tesi R Stehle 2005 Sarcomeric determinants of striated muscle relaxation kinetics Pflugers Arch 449 505 517
    • (2005) Pflugers Arch , vol.449 , pp. 505-517
    • Poggesi, C.1    Tesi, C.2    Stehle, R.3
  • 10
    • 0032109073 scopus 로고    scopus 로고
    • Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope
    • JE Sader 1998 Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope J Appl Phys 81 64 76
    • (1998) J Appl Phys , vol.81 , pp. 64-76
    • Sader, J.E.1
  • 11
    • 0023826020 scopus 로고    scopus 로고
    • Surface-charge properties of fluorine-doped lead borosilicate glass
    • M Shimbo K Furukawa K Tanzawa T Higuchi 1998 Surface-charge properties of fluorine-doped lead borosilicate glass IEEE 35 124 128
    • (1998) IEEE , vol.35 , pp. 124-128
    • Shimbo, M.1    Furukawa, K.2    Tanzawa, K.3    Higuchi, T.4
  • 12
    • 33847665548 scopus 로고    scopus 로고
    • Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope: Arbitrary mode order
    • CA van Eysden JE Sader 2007 Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope: arbitrary mode order J Appl Phys 101 44908
    • (2007) J Appl Phys , vol.101 , pp. 44908
    • Van Eysden, C.A.1    Sader, J.E.2
  • 13
    • 0001456211 scopus 로고    scopus 로고
    • Frequency shifts of cantilevers vibrating in various media
    • S Weigert M Dreier M Hegner 1996 Frequency shifts of cantilevers vibrating in various media Appl Phys Lett 69 2834 2836
    • (1996) Appl Phys Lett , vol.69 , pp. 2834-2836
    • Weigert, S.1    Dreier, M.2    Hegner, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.