Volumn 55, Issue 1, 2009, Pages 19-23

In-vitro localization of initial flow-induced thrombus formation in bileaflet mechanical heart valves

Author keywords

[No Author keywords available]

Indexed keywords

ANTI-COAGULATION; AORTIC POSITION; BILEAFLET; BLOOD CLOTTING; CLOT FORMATION; IN-VITRO; IN-VIVO; INITIAL FLOW; INITIAL STAGES; MECHANICAL HEART VALVES; MOCK CIRCULATION; ST. JUDE MEDICAL; THROMBUS FORMATION; VALVE DESIGN;

EID: 62449113173     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e318190458f     Document Type: Article
Times cited : (17)

References (23)
  • 1
    • 0029552024 scopus 로고
    • Results with mechanical cardiac valvular prostheses
    • Akins CW: Results with mechanical cardiac valvular prostheses. Ann Thorac Surg 60: 1836-1844, 1995.
    • (1995) Ann Thorac Surg , vol.60 , pp. 1836-1844
    • Akins, C.W.1
  • 2
    • 33846240313 scopus 로고    scopus 로고
    • Identification of a 2-stage platelet aggregation process mediating shear-dependent thrombus formation
    • Maxwell MJ, Westein E, Nesbitt WS, et al: Identification of a 2-stage platelet aggregation process mediating shear-dependent thrombus formation. Blood 109: 566-576, 2007.
    • (2007) Blood , vol.109 , pp. 566-576
    • Maxwell, M.J.1    Westein, E.2    Nesbitt, W.S.3
  • 3
    • 0032954730 scopus 로고    scopus 로고
    • Pressure and flow fields in the hinge region of bileaflet mechanical heart valves
    • Gao ZB, Hosein N, Dai FF, Hwang NHC: Pressure and flow fields in the hinge region of bileaflet mechanical heart valves. J Heart Valve Dis 8: 197-205, 1999.
    • (1999) J Heart Valve Dis , vol.8 , pp. 197-205
    • Gao, Z.B.1    Hosein, N.2    Dai, F.F.3    Hwang, N.H.C.4
  • 4
    • 0034181001 scopus 로고    scopus 로고
    • An in vitro study of the hinge and near-field forward flow Dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve
    • Ellis JT, Travis BR, Yoganathan AP: An in vitro study of the hinge and near-field forward flow Dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve. Ann Biomed Eng 28: 524-532, 2000.
    • (2000) Ann Biomed Eng , vol.28 , pp. 524-532
    • Ellis, J.T.1    Travis, B.R.2    Yoganathan, A.P.3
  • 5
    • 0036740792 scopus 로고    scopus 로고
    • Microflow fields in the hinge region of the Carbomedics bileaflet mechanical heart valve design
    • Leo HL, He Z, Ellis JT, Yoganathan AP: Microflow fields in the hinge region of the Carbomedics bileaflet mechanical heart valve design. J Thorac Cardiovasc Surg 124: 561-574, 2002.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 561-574
    • Leo, H.L.1    He, Z.2    Ellis, J.T.3    Yoganathan, A.P.4
  • 6
    • 0042343780 scopus 로고    scopus 로고
    • An in vitro assessment by means of laser Doppler velocimetry of the Medtronic advantage bileaflet mechanical heart valve hinge flow
    • Saxena R, Lemmon J, Ellis J, Yoganathan AP: An in vitro assessment by means of laser Doppler velocimetry of the Medtronic advantage bileaflet mechanical heart valve hinge flow. J Thorac Cardiovasc Surg 126: 90-98, 2003.
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 90-98
    • Saxena, R.1    Lemmon, J.2    Ellis, J.3    Yoganathan, A.P.4
  • 7
    • 34547177301 scopus 로고    scopus 로고
    • Spatio-temporal flow analysis in bileaflet heart valve hinge regions: Potential analysis for blood element damage
    • Simon HA, Dasi LP, Leo HL, Yoganathan AP: Spatio-temporal flow analysis in bileaflet heart valve hinge regions: Potential analysis for blood element damage. Ann Biomed Eng 35: 1333-1346, 2007.
    • (2007) Ann Biomed Eng , vol.35 , pp. 1333-1346
    • Simon, H.A.1    Dasi, L.P.2    Leo, H.L.3    Yoganathan, A.P.4
  • 8
    • 0016864942 scopus 로고
    • Structural aspects of the milk clotting process: Comparative features with the blood clotting process
    • Jolles P: Structural aspects of the milk clotting process: Comparative features with the blood clotting process. Mol Cell Biochem 7: 73-85, 1975.
    • (1975) Mol Cell Biochem , vol.7 , pp. 73-85
    • Jolles, P.1
  • 9
    • 0020611086 scopus 로고
    • A blood analogue for the experimental study of flow-related thrombosis at prosthetic heart valves
    • Lewis JMO, MacLeod N: A blood analogue for the experimental study of flow-related thrombosis at prosthetic heart valves. Cardiovasc Res 17: 466-475, 1983.
    • (1983) Cardiovasc Res , vol.17 , pp. 466-475
    • Lewis, J.M.O.1    MacLeod, N.2
  • 10
    • 0030051353 scopus 로고    scopus 로고
    • The use of enzyme activated milk for in-vitro simulation of prosthetic valve thrombosis
    • Keggen LA, Black MM, Lawford PV, et al: The use of enzyme activated milk for in-vitro simulation of prosthetic valve thrombosis. J Heart Valve Dis 5: 74-83, 1996.
    • (1996) J Heart Valve Dis , vol.5 , pp. 74-83
    • Keggen, L.A.1    Black, M.M.2    Lawford, P.V.3
  • 11
    • 0034080224 scopus 로고    scopus 로고
    • Ultrasonic determination of clot deposition rates in a milk-based, in-vitro procedure for thrombogenicity assessment
    • Christy JRE, Marosek KW: Ultrasonic determination of clot deposition rates in a milk-based, in-vitro procedure for thrombogenicity assessment. J Heart Valve Dis 9: 379-388, 2000.
    • (2000) J Heart Valve Dis , vol.9 , pp. 379-388
    • Christy, J.R.E.1    Marosek, K.W.2
  • 12
    • 5144219874 scopus 로고    scopus 로고
    • An in-vitro technique for assessment of thrombogenicity in mechanical prosthetic cardiac valves: Eval- uation with a range of valve types
    • Martin AJ, Christy JRE: An in-vitro technique for assessment of thrombogenicity in mechanical prosthetic cardiac valves: Eval- uation with a range of valve types. J Heart Valve Dis 13: 509-520, 2004.
    • (2004) J Heart Valve Dis , vol.13 , pp. 509-520
    • Martin, A.J.1    Christy, J.R.E.2
  • 13
    • 4544291071 scopus 로고    scopus 로고
    • Flow-induced platelet activation in bileaflet and monoleaflet mechanical heart valves
    • Yin W, Alemu Y, Affeld K, et al: Flow-induced platelet activation in bileaflet and monoleaflet mechanical heart valves. Ann Biomed Eng 32: 1058-1066, 2004.
    • (2004) Ann Biomed Eng , vol.32 , pp. 1058-1066
    • Yin, W.1    Alemu, Y.2    Affeld, K.3
  • 14
    • 0034000468 scopus 로고    scopus 로고
    • Velocities, shear stresses and blood damage potential of the leakage jets of the Medtronic Paralell bileaflet valve
    • Zimmer R, Steegers A, Paul R, et al: Velocities, shear stresses and blood damage potential of the leakage jets of the Medtronic Paralell bileaflet valve. Int J Artif Organs 23: 41-48, 2000.
    • (2000) Int J Artif Organs , vol.23 , pp. 41-48
    • Zimmer, R.1    Steegers, A.2    Paul, R.3
  • 15
    • 27744445762 scopus 로고    scopus 로고
    • In-vivo turbulent stresses of bileaflet prosthesis leakage jets
    • Travis BR, Christensen TD, Smerup M, et al: In-vivo turbulent stresses of bileaflet prosthesis leakage jets. J Heart Valve Dis 14: 644-656, 2005.
    • (2005) J Heart Valve Dis , vol.14 , pp. 644-656
    • Travis, B.R.1    Christensen, T.D.2    Smerup, M.3
  • 16
    • 12344269940 scopus 로고    scopus 로고
    • Comparison of the hinge flow field of two bileaflet mechanical heart valves under aortic and mitral conditions
    • Simon HA, Leo HL, Carberry J, Yoganathan AP: Comparison of the hinge flow field of two bileaflet mechanical heart valves under aortic and mitral conditions. Ann Biomed Eng 32: 1607-1617, 2004.
    • (2004) Ann Biomed Eng , vol.32 , pp. 1607-1617
    • Simon, H.A.1    Leo, H.L.2    Carberry, J.3    Yoganathan, A.P.4
  • 17
    • 17944374250 scopus 로고    scopus 로고
    • Mechanical valve thrombosis in a chronic animal model: Differences between monoleaflet and bileaflet valves
    • Meuris B, Verbeken E, Flameng W: Mechanical valve thrombosis in a chronic animal model: Differences between monoleaflet and bileaflet valves. J Heart Valve Dis 14: 96-104, 2005.
    • (2005) J Heart Valve Dis , vol.14 , pp. 96-104
    • Meuris, B.1    Verbeken, E.2    Flameng, W.3
  • 18
    • 4544287269 scopus 로고    scopus 로고
    • Flow-induced platelet activation in mechanical heart valves
    • Bluestein D, Yin W, Affeld K, Jesty J: Flow-induced platelet activation in mechanical heart valves. J Heart Valve Dis 13: 501-508, 2004.
    • (2004) J Heart Valve Dis , vol.13 , pp. 501-508
    • Bluestein, D.1    Yin, W.2    Affeld, K.3    Jesty, J.4
  • 19
    • 0036847510 scopus 로고    scopus 로고
    • Platelet aggregation and activation under complex patterns of shear stress
    • Zhang JN, Bergeron AL, Yu Q, et al: Platelet aggregation and activation under complex patterns of shear stress. Thromb Haemost 88: 817-821, 2002.
    • (2002) Thromb Haemost , vol.88 , pp. 817-821
    • Zhang, J.N.1    Bergeron, A.L.2    Yu, Q.3
  • 20
    • 0030250479 scopus 로고    scopus 로고
    • Platelets are deposited early post-operatively on the leaflet of a mechanical heart valve in sheep without postoperative anticoagulants or antiplatelet agents. A scanning electron microscopic observation of the pyrolytic carbon surface in a mechanical heart valve
    • Okazaki Y, Wika KE, Matsuyoshi T, et al: Platelets are deposited early post-operatively on the leaflet of a mechanical heart valve in sheep without postoperative anticoagulants or antiplatelet agents. A scanning electron microscopic observation of the pyrolytic carbon surface in a mechanical heart valve. ASAIO J 42: M750-M754, 1996.
    • (1996) ASAIO J , vol.42
    • Okazaki, Y.1    Wika, K.E.2    Matsuyoshi, T.3
  • 21
    • 33847027372 scopus 로고    scopus 로고
    • Prospective randomised comparison of the CarboMedics and St. Jude Medical bileaflet mechanical heart valve prostheses: Ten year follow-up
    • BryanAJ, Rogers CA, Bayliss K, et al: Prospective randomised comparison of the CarboMedics and St. Jude Medical bileaflet mechanical heart valve prostheses: Ten year follow-up. J Thorac Cardisovasc Surg 133: 614-622, 2007.
    • (2007) J Thorac Cardisovasc Surg , vol.133 , pp. 614-622
    • Bryan, A.J.1    Rogers, C.A.2    Bayliss, K.3
  • 22
    • 34347337803 scopus 로고    scopus 로고
    • Single-center outcome analysis of 1,161 patients with St. Jude Medical and ATS open pivot mechanical heart valves
    • Bernet FH, Baykut D, Grize L, Zerkoski HR: Single-center outcome analysis of 1,161 patients with St. Jude Medical and ATS open pivot mechanical heart valves. J Heart Valve Dis 16: 151-158, 2007.
    • (2007) J Heart Valve Dis , vol.16 , pp. 151-158
    • Bernet, F.H.1    Baykut, D.2    Grize, L.3    Zerkoski, H.R.4
  • 23
    • 33845509902 scopus 로고    scopus 로고
    • Multicentered European study on the safety and effectiveness of the On-X prosthetic heart valve: Intermediate follow-up
    • Palatianos GM, Laczkovics AM, Simon P, et al: Multicentered European study on the safety and effectiveness of the On-X prosthetic heart valve: Intermediate follow-up. Ann Thorac Surg 83: 40-46, 2007.
    • (2007) Ann Thorac Surg , vol.83 , pp. 40-46
    • Palatianos, G.M.1    Laczkovics, A.M.2    Simon, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.