메뉴 건너뛰기




Volumn 14, Issue 5, 2005, Pages 644-656

In-vivo turbulent stresses of bileaflet prosthesis leakage jets

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BLOOD FLOW VELOCITY; CORONARY ARTERY BLOOD FLOW; DOPPLER ECHOGRAPHY; EQUIPMENT DESIGN; EXERCISE; FEMALE; HEART VENTRICLE PRESSURE; IN VIVO STUDY; METHODOLOGY; MITRAL VALVE; MITRAL VALVE PROSTHESIS; NONHUMAN; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROSTHESIS LOOSENING; QUANTITATIVE ANALYSIS; RISK FACTOR; SAINT JUDE HEART VALVE PROSTHESIS; SHEAR STRESS; SWINE; THROMBOEMBOLISM; TURBULENT FLOW;

EID: 27744445762     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (35)
  • 1
    • 0032198438 scopus 로고    scopus 로고
    • ACC/AHA Guidelines for the Management of Patients With Valvular Heart Disease. Executive Summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients With Valvular Heart Disease)
    • Bonow RO, Carabello B, de Leon AC, et al. ACC/AHA Guidelines for the Management of Patients With Valvular Heart Disease. Executive Summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients With Valvular Heart Disease). J Heart Valve Dis 1998;7:672-707
    • (1998) J. Heart Valve Dis. , vol.7 , pp. 672-707
    • Bonow, R.O.1    Carabello, B.2    de Leon, A.C.3
  • 2
    • 0034741648 scopus 로고    scopus 로고
    • Bileaflet aortic valve prosthesis pivot geometry influences platelet secretion and anionic phospholipid exposure
    • Travis BR, Marzec UM, Leo HL, et al. Bileaflet aortic valve prosthesis pivot geometry influences platelet secretion and anionic phospholipid exposure. Ann Biomed Eng 2001;29:657-664
    • (2001) Ann. Biomed. Eng. , vol.29 , pp. 657-664
    • Travis, B.R.1    Marzec, U.M.2    Leo, H.L.3
  • 3
    • 0031281261 scopus 로고    scopus 로고
    • Three-component laser Doppler velocimetry measurements in the regurgitant flow region of a Björk-Shiley monostrut mitral valve
    • Meyer RS, Deutsch S, Maymir JC, Geselowitz DB, Tarbell JM. Three-component laser Doppler velocimetry measurements in the regurgitant flow region of a Björk-Shiley monostrut mitral valve. Ann Biomed Eng 1997;25:1081-1091
    • (1997) Ann. Biomed. Eng. , vol.25 , pp. 1081-1091
    • Meyer, R.S.1    Deutsch, S.2    Maymir, J.C.3    Geselowitz, D.B.4    Tarbell, J.M.5
  • 4
    • 0034879360 scopus 로고    scopus 로고
    • A reevaluation and discussion on the threshold limit for hemolysis in a turbulent shear flow
    • Lu PC, Lai HC, Liu JS. A reevaluation and discussion on the threshold limit for hemolysis in a turbulent shear flow. J Biomech 2001;34:1361-1364
    • (2001) J. Biomech. , vol.34 , pp. 1361-1364
    • Lu, P.C.1    Lai, H.C.2    Liu, J.S.3
  • 5
    • 0035085186 scopus 로고    scopus 로고
    • The sensitivity of indicators of thrombosis initiation to a bileaflet prosthesis leakage stimulus
    • Travis BR, Marzec UM, Ellis JT, et al. The sensitivity of indicators of thrombosis initiation to a bileaflet prosthesis leakage stimulus. J Heart Valve Dis 2001;10:228-238
    • (2001) J. Heart Valve Dis. , vol.10 , pp. 228-238
    • Travis, B.R.1    Marzec, U.M.2    Ellis, J.T.3
  • 6
    • 27744563165 scopus 로고    scopus 로고
    • Personal Communication
    • Yoganathan AP. 2001. Personal Communication
    • (2001)
    • Yoganathan, A.P.1
  • 8
    • 0022592273 scopus 로고
    • In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses
    • Woo YR, Yoganathan AP. In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses. J Biomech 1986;19:39-51
    • (1986) J. Biomech. , vol.19 , pp. 39-51
    • Woo, Y.R.1    Yoganathan, A.P.2
  • 10
    • 0029828882 scopus 로고    scopus 로고
    • An in-vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves
    • Ellis JT, Healy TM, Fontaine AA, et al. An in-vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves. J Heart Valve Dis 1996;5:600-606
    • (1996) J. Heart Valve Dis. , vol.5 , pp. 600-606
    • Ellis, J.T.1    Healy, T.M.2    Fontaine, A.A.3
  • 11
    • 0032990519 scopus 로고    scopus 로고
    • Leakage flow at mechanical heart valve prostheses: Improved washout or increased blood damage?
    • Steegers A, Paul R, Reul H, Rau G. Leakage flow at mechanical heart valve prostheses: Improved washout or increased blood damage? J Heart Valve Dis 1999;8:312-323
    • (1999) J. Heart Valve Dis. , vol.8 , pp. 312-323
    • Steegers, A.1    Paul, R.2    Reul, H.3    Rau, G.4
  • 12
    • 0030865224 scopus 로고    scopus 로고
    • Effects of tilting disk heart valve gap width on regurgitant flow through an artificial heart mitral valve
    • Maymir JC, Deutsch S, Meyer RS, Geselowitz DB, Tarbell JM. Effects of tilting disk heart valve gap width on regurgitant flow through an artificial heart mitral valve. Artif Organs 1997;21:1014-1025
    • (1997) Artif. Organs , vol.21 , pp. 1014-1025
    • Maymir, J.C.1    Deutsch, S.2    Meyer, R.S.3    Geselowitz, D.B.4    Tarbell, J.M.5
  • 13
    • 0035319375 scopus 로고    scopus 로고
    • Laser Doppler velocimetry and flow visualization studies in the regurgitant leakage flow region of three mechanical mitral valves
    • Meyer RS, Deutsch S, Bachmann CB, Tarbell JM. Laser Doppler velocimetry and flow visualization studies in the regurgitant leakage flow region of three mechanical mitral valves. Artif Organs 2001;25:292-299
    • (2001) Artif. Organs , vol.25 , pp. 292-299
    • Meyer, R.S.1    Deutsch, S.2    Bachmann, C.B.3    Tarbell, J.M.4
  • 14
    • 0036107519 scopus 로고    scopus 로고
    • An analysis of turbulent shear stresses in leakage flow through a bileaflet mechanical prostheses
    • Travis BR, Leo HL, Shah PA, Frakes DH, Yoganathan AP. An analysis of turbulent shear stresses in leakage flow through a bileaflet mechanical prostheses. J Biomech Eng 2002;124:155-165
    • (2002) J. Biomech. Eng. , vol.124 , pp. 155-165
    • Travis, B.R.1    Leo, H.L.2    Shah, P.A.3    Frakes, D.H.4    Yoganathan, A.P.5
  • 15
    • 0033966638 scopus 로고    scopus 로고
    • A comparison of the hinge and near-hinge flow fields of the St. Jude Medical hemodynamic plus and Regent bileaflet mechanical heart valves
    • Ellis JT, Yoganathan AP. A comparison of the hinge and near-hinge flow fields of the St. Jude Medical hemodynamic plus and Regent bileaflet mechanical heart valves. J Thorac Cardiovasc Surg 2000;119:83-93
    • (2000) J. Thorac. Cardiovasc. Surg. , vol.119 , pp. 83-93
    • Ellis, J.T.1    Yoganathan, A.P.2
  • 16
    • 0042343780 scopus 로고    scopus 로고
    • An in vitro assessment by means of laser Doppler velocimetry of the Medtronic advantage bileaflet mechanical heart valve hinge flow
    • Saxena R, Lemmon J, Ellis J, Yoganathan A. An in vitro assessment by means of laser Doppler velocimetry of the Medtronic advantage bileaflet mechanical heart valve hinge flow. J Thorac Cardiovasc Surg 2003;126:90-98
    • (2003) J. Thorac. Cardiovasc. Surg. , vol.126 , pp. 90-98
    • Saxena, R.1    Lemmon, J.2    Ellis, J.3    Yoganathan, A.4
  • 17
    • 0036740792 scopus 로고    scopus 로고
    • Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design
    • Leo HL, He Z, Ellis JT, Yoganathan AP. Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design. J Thorac Cardiovasc Surg 2002;124:561-574
    • (2002) J. Thorac. Cardiovasc. Surg. , vol.124 , pp. 561-574
    • Leo, H.L.1    He, Z.2    Ellis, J.T.3    Yoganathan, A.P.4
  • 18
    • 0030059598 scopus 로고    scopus 로고
    • In vitro testing of artificial heart valves: Comparison between Newtonian and non-Newtonian fluids
    • Pohl M, Wendt MO, Werner S, Koch B, Lerche D. In vitro testing of artificial heart valves: Comparison between Newtonian and non-Newtonian fluids. Artif Organs 1996;20:37-46
    • (1996) Artif. Organs , vol.20 , pp. 37-46
    • Pohl, M.1    Wendt, M.O.2    Werner, S.3    Koch, B.4    Lerche, D.5
  • 20
    • 0027511274 scopus 로고
    • Frequency and severity of intravascular hemolysis after left-sided cardiac valve replacement with Medtronic Hall and St. Jude Medical prostheses, and influence of prosthetic type, position, size and number
    • Skoularigis J, Essop MR, Skudicky D, Middlemost SJ, Sareli P. Frequency and severity of intravascular hemolysis after left-sided cardiac valve replacement with Medtronic Hall and St. Jude Medical prostheses, and influence of prosthetic type, position, size and number. Am J Cardiol 1993;71:587-591
    • (1993) Am. J. Cardiol. , vol.71 , pp. 587-591
    • Skoularigis, J.1    Essop, M.R.2    Skudicky, D.3    Middlemost, S.J.4    Sareli, P.5
  • 21
    • 0033562636 scopus 로고    scopus 로고
    • Intravascular hemolysis after mitral and aortic valve replacement with different types of mechanical prostheses
    • Ismeno G, Renzulli A, Carozza A, et al. Intravascular hemolysis after mitral and aortic valve replacement with different types of mechanical prostheses. Int J Cardiol 1999;69:179-183
    • (1999) Int. J. Cardiol. , vol.69 , pp. 179-183
    • Ismeno, G.1    Renzulli, A.2    Carozza, A.3
  • 22
    • 0028325512 scopus 로고
    • A new perivascular multi-element pulsed Doppler ultrasound system for in vivo studies of velocity fields and turbulent stresses in large vessels
    • Nygaard H, Hasenkam JM, Pedersen EM, Kim WY, Paulsen PK. A new perivascular multi-element pulsed Doppler ultrasound system for in vivo studies of velocity fields and turbulent stresses in large vessels. Med Biol Eng Comput 1994;32:55-62
    • (1994) Med. Biol. Eng. Comput. , vol.32 , pp. 55-62
    • Nygaard, H.1    Hasenkam, J.M.2    Pedersen, E.M.3    Kim, W.Y.4    Paulsen, P.K.5
  • 23
    • 0030420775 scopus 로고    scopus 로고
    • Towards better uncertainty estimates for turbulent statistics
    • Benedict LH, Gould RD. Towards better uncertainty estimates for turbulent statistics. Exp Fluids 1996;22:129-136
    • (1996) Exp. Fluids , vol.22 , pp. 129-136
    • Benedict, L.H.1    Gould, R.D.2
  • 24
    • 0023831457 scopus 로고
    • Laser Doppler velocity bias in separated turbulent flows
    • Petrie H, Samimy M, Addy A. Laser Doppler velocity bias in separated turbulent flows. Exp Fluids 1988;6:80-88
    • (1988) Exp. Fluids , vol.6 , pp. 80-88
    • Petrie, H.1    Samimy, M.2    Addy, A.3
  • 25
    • 2442503776 scopus 로고
    • Oblique flow vectors from dispersing jets produce the velocity overestimation on angle corrected continuous wave Doppler studies: In vitro laser Doppler investigations
    • Yoganathan AP, Recusani F, Valdez-Cruz L, Sung HW, Sahn DJ. Oblique flow vectors from dispersing jets produce the velocity overestimation on angle corrected continuous wave Doppler studies: In vitro laser Doppler investigations. Circulation 1987;76(Suppl.IV):353-355
    • (1987) Circulation , vol.76 , Issue.SUPPL. IV , pp. 353-355
    • Yoganathan, A.P.1    Recusani, F.2    Valdez-Cruz, L.3    Sung, H.W.4    Sahn, D.J.5
  • 27
    • 0034000468 scopus 로고    scopus 로고
    • Velocities, shear stresses and blood damage potential of the leakage jets of the Medtronic Parallel bileaflet valve
    • Zimmer R, Steegers A, Paul R, Affeld K, Reul H. Velocities, shear stresses and blood damage potential of the leakage jets of the Medtronic Parallel bileaflet valve. Int J Artif Organs 2000;23:41-48
    • (2000) Int. J. Artif. Organs , vol.23 , pp. 41-48
    • Zimmer, R.1    Steegers, A.2    Paul, R.3    Affeld, K.4    Reul, H.5
  • 29
    • 0031464974 scopus 로고    scopus 로고
    • 19 mm sized bileaflet valve prostheses flow field investigated by bidimensional laser Doppler velocimetry
    • Barbaro V, Grigioni M, Daniele C, D'Avenio G, Boccanera G. 19 mm sized bileaflet valve prostheses flow field investigated by bidimensional laser Doppler velocimetry. Int J Artif Organs 1997;20:622-636
    • (1997) Int. J. Artif. Organs , vol.20 , pp. 622-636
    • Barbaro, V.1    Grigioni, M.2    Daniele, C.3    D'Avenio, G.4    Boccanera, G.5
  • 30
    • 0030152830 scopus 로고    scopus 로고
    • Identification of peak stresses in cardiac prostheses: A comparison of two dimensional versus three dimensional principle stress analyses
    • Fontaine A, Ellis J, Healy T, Hopmeyer J, Yoganathan A. Identification of peak stresses in cardiac prostheses: A comparison of two dimensional versus three dimensional principle stress analyses. Am Soc Artif Intern Organs J 1996;42:154-163
    • (1996) Am. Soc. Artif. Intern. Organs J. , vol.42 , pp. 154-163
    • Fontaine, A.1    Ellis, J.2    Healy, T.3    Hopmeyer, J.4    Yoganathan, A.5
  • 31
    • 0025082325 scopus 로고
    • Estimation of shear stress-related blood damage in heart valve prostheses - In vitro comparison of 25 aortic valves
    • Giersiepen M, Wurzinger L, Opitz R, Reul H. Estimation of shear stress-related blood damage in heart valve prostheses - in vitro comparison of 25 aortic valves. Int J Artif Organs 1990;13:300-306
    • (1990) Int. J. Artif. Organs , vol.13 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.2    Opitz, R.3    Reul, H.4
  • 32
    • 0034176164 scopus 로고    scopus 로고
    • Turbulence characteristics downstream of bileaflet aortic valve prostheses
    • Liu J, Lu P, Chu S. Turbulence characteristics downstream of bileaflet aortic valve prostheses. J Biomech Eng 2000;122:118-124
    • (2000) J. Biomech. Eng. , vol.122 , pp. 118-124
    • Liu, J.1    Lu, P.2    Chu, S.3
  • 33
    • 0022672034 scopus 로고
    • Two-component laser velocimeter measurements downstream of heart valve prostheses in pulsatile flow
    • Tiederman W, Steinle M, Phillips W. Two-component laser velocimeter measurements downstream of heart valve prostheses in pulsatile flow. J Biomech Eng 1988;108:59-64
    • (1988) J. Biomech. Eng. , vol.108 , pp. 59-64
    • Tiederman, W.1    Steinle, M.2    Phillips, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.