메뉴 건너뛰기




Volumn , Issue , 2008, Pages 3669-3672

In vitro evaluation of an oscillating dual-mode ultrasound probe for sector imaging and directive therapy

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC FIELDS; PROBES; ULTRASONICS;

EID: 61849115237     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2008.4650003     Document Type: Conference Paper
Times cited : (2)

References (14)
  • 1
    • 32144459357 scopus 로고    scopus 로고
    • Extracorporeal high intensity focused ultrasound in the treatment of patients with solid malignancy
    • F. Wu, "Extracorporeal high intensity focused ultrasound in the treatment of patients with solid malignancy," Minim. Invasive. Ther. Allied. Technol., vol. 15, pp. 26-35, 2006.
    • (2006) Minim. Invasive. Ther. Allied. Technol , vol.15 , pp. 26-35
    • Wu, F.1
  • 3
    • 0034306054 scopus 로고    scopus 로고
    • Ultrasound applicators with internal water-cooling for high-powered interstitial thermal therapy
    • D. Deardorff and C. J. Diederich, "Ultrasound applicators with internal water-cooling for high-powered interstitial thermal therapy," IEEE Trans. Biomedical Eng., vol. 47, pp. 1356-1365, 2000.
    • (2000) IEEE Trans. Biomedical Eng , vol.47 , pp. 1356-1365
    • Deardorff, D.1    Diederich, C.J.2
  • 5
    • 33750723510 scopus 로고    scopus 로고
    • Dual-mode ultrasound phased arrays for image-guided surgery
    • S. E. Ebbini, H. Yao, and A. Shrestha, "Dual-mode ultrasound phased arrays for image-guided surgery," Ultrasonic Imag., vol. 28, pp. 65-82, 2006.
    • (2006) Ultrasonic Imag , vol.28 , pp. 65-82
    • Ebbini, S.E.1    Yao, H.2    Shrestha, A.3
  • 7
  • 10
    • 0036130266 scopus 로고    scopus 로고
    • Optimizing the shape of ultrasound transducers for interstitial thermal ablation
    • C. Lafon, D. Melodelima, Y. Theilliére, F. Prat, J. Y. Chapelon, D. Cathignol, "Optimizing the shape of ultrasound transducers for interstitial thermal ablation," Med. Phys., vol. 29, pp. 290-297, 2002.
    • (2002) Med. Phys , vol.29 , pp. 290-297
    • Lafon, C.1    Melodelima, D.2    Theilliére, Y.3    Prat, F.4    Chapelon, J.Y.5    Cathignol, D.6
  • 11
    • 0141940275 scopus 로고    scopus 로고
    • High intensity focused ultrasound: Surgery of the future?
    • J. E. Kennedy, G. R. ter Haar, D. Cranston, "High intensity focused ultrasound: surgery of the future?" Br. J. Radiol., vol. 76, pp. 590-599, 2003.
    • (2003) Br. J. Radiol , vol.76 , pp. 590-599
    • Kennedy, J.E.1    ter Haar, G.R.2    Cranston, D.3
  • 12
    • 0037035346 scopus 로고    scopus 로고
    • Theoretical model of internally cooled interstitial ultrasound applicators for thermal therapy
    • P. D. Tyréus and C. J. Diederich, "Theoretical model of internally cooled interstitial ultrasound applicators for thermal therapy," Phys. Med. Biol., vol. 47, pp. 1073-1089, 2002.
    • (2002) Phys. Med. Biol , vol.47 , pp. 1073-1089
    • Tyréus, P.D.1    Diederich, C.J.2
  • 14
    • 2942715060 scopus 로고    scopus 로고
    • A. Anand and P. M. Kaczkowski, Monitoring of high intensity focused ultrasound (HIFU) induced lesions using backscattered ultrasound, J. Acoust. Soc. Amer., ARLO, 5, pp. 88-94, 2004
    • A. Anand and P. M. Kaczkowski, "Monitoring of high intensity focused ultrasound (HIFU) induced lesions using backscattered ultrasound," J. Acoust. Soc. Amer., ARLO, vol. 5, pp. 88-94, 2004


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.