메뉴 건너뛰기




Volumn 31, Issue 2, 2005, Pages 251-259

Monitoring the formation of thermal lesions with heat-induced echo-strain imaging: A feasibility study

Author keywords

Coagulation; Echo shift; Echo strain; HIFU; Lesion; Speed of sound; Temperature; Thermal expansion; Time delay; Ultrasound

Indexed keywords

BACKSCATTERING; DEFORMATION; IMAGE ANALYSIS; TISSUE; ULTRASONICS;

EID: 13644252233     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2004.11.004     Document Type: Article
Times cited : (87)

References (35)
  • 1
    • 2942715060 scopus 로고    scopus 로고
    • Monitoring formation of high intensity focused ultrasound (HIFU) induced lesions using backscattered ultrasound
    • A. Anand, P.J. Kaczkowski Monitoring formation of high intensity focused ultrasound (HIFU) induced lesions using backscattered ultrasound ARLO 5 3 2004 88 94
    • (2004) ARLO , vol.5 , Issue.3 , pp. 88-94
    • Anand, A.1    Kaczkowski, P.J.2
  • 2
    • 0018600264 scopus 로고
    • Ultrasonic attenuation and propagation speed in mammalian tissues as a function of temperature
    • J.C. Bamber, C.R. Hill Ultrasonic attenuation and propagation speed in mammalian tissues as a function of temperature Ultrasound Med Biol 5 2 1979 149 157
    • (1979) Ultrasound Med Biol , vol.5 , Issue.2 , pp. 149-157
    • Bamber, J.C.1    Hill, C.R.2
  • 4
    • 0029274335 scopus 로고
    • Evaluation of accuracy of a theoretical model for predicting the necrosed tissue volume during focused ultrasound surgery
    • C.A. Damianou, K. Hynynen, X. Fan Evaluation of accuracy of a theoretical model for predicting the necrosed tissue volume during focused ultrasound surgery IEEE Trans Ultrason Ferroelec Freq Control 42 2 1995 182 187
    • (1995) IEEE Trans Ultrason Ferroelec Freq Control , vol.42 , Issue.2 , pp. 182-187
    • Damianou, C.A.1    Hynynen, K.2    Fan, X.3
  • 6
    • 0001603326 scopus 로고
    • Ultrasonically produced localized selective lesions in the central nervous system
    • W.J. Fry, J.W. Barnard, F.J. Fry Ultrasonically produced localized selective lesions in the central nervous system Am J Phys Med 34 3 1955 413 423
    • (1955) Am J Phys Med , vol.34 , Issue.3 , pp. 413-423
    • Fry, W.J.1    Barnard, J.W.2    Fry, F.J.3
  • 7
    • 0029677201 scopus 로고    scopus 로고
    • A clinical, noninvasive, MR imaging-monitored ultrasound surgery method
    • K. Hynynen, W.R. Freund, H.E. Cline A clinical, noninvasive, MR imaging-monitored ultrasound surgery method Radiographics 16 1 1996 185 195
    • (1996) Radiographics , vol.16 , Issue.1 , pp. 185-195
    • Hynynen, K.1    Freund, W.R.2    Cline, H.E.3
  • 8
    • 0032931389 scopus 로고    scopus 로고
    • The feasibility of elastographic visualization of HIFU-induced thermal lesions in soft tissues
    • F. Kallel, R.J. Stafford, R.E. Price The feasibility of elastographic visualization of HIFU-induced thermal lesions in soft tissues Ultrasound Med Biol 25 4 1999 641 647
    • (1999) Ultrasound Med Biol , vol.25 , Issue.4 , pp. 641-647
    • Kallel, F.1    Stafford, R.J.2    Price, R.E.3
  • 9
    • 0033663650 scopus 로고    scopus 로고
    • Cylindrical thermal coagulation necrosis using an interstitial applicator with a plane ultrasonic transducer: In vitro and in vivo experiments versus computer simulations
    • C. Lafon, F. Prat, J.Y. Chapelon Cylindrical thermal coagulation necrosis using an interstitial applicator with a plane ultrasonic transducer In vitro and in vivo experiments versus computer simulations Int J Hypertherm 16 6 2000 508 522
    • (2000) Int J Hypertherm , vol.16 , Issue.6 , pp. 508-522
    • Lafon, C.1    Prat, F.2    Chapelon, J.Y.3
  • 10
    • 0031383944 scopus 로고    scopus 로고
    • Ultrasonic mapping of temperature in hyperthermia: The thermal lens effect
    • C. Le Floch, M. Fink Ultrasonic mapping of temperature in hyperthermia The thermal lens effect IEEE Ultrason Sympos 2 1997 1301 1304
    • (1997) IEEE Ultrason Sympos , vol.2 , pp. 1301-1304
    • Le Floch, C.1    Fink, M.2
  • 12
    • 0029798475 scopus 로고    scopus 로고
    • Noninvasive temperature estimation in tissue via ultrasound echo-shifts: Part I. Analytical model
    • R. Maass-Moreno, C.A. Damianou Noninvasive temperature estimation in tissue via ultrasound echo-shifts: Part I. Analytical model J Acoust Soc Am 100 4 1996 2514 2521
    • (1996) J Acoust Soc Am , vol.100 , Issue.4 , pp. 2514-2521
    • Maass-Moreno, R.1    Damianou, C.A.2
  • 13
    • 0029794863 scopus 로고    scopus 로고
    • Noninvasive temperature estimation in tissue via ultrasound echo-shifts: Part II. in vitro study
    • R. Maass-Moreno, C.A. Damianou Noninvasive temperature estimation in tissue via ultrasound echo-shifts: Part II. In vitro study J Acoust Soc Am 100 4 1996 2522 2530
    • (1996) J Acoust Soc Am , vol.100 , Issue.4 , pp. 2522-2530
    • Maass-Moreno, R.1    Damianou, C.A.2
  • 14
    • 0035112474 scopus 로고    scopus 로고
    • MRI monitoring of the thermal ablation of tissue: Effects of long exposure times
    • N. McDannold, K. Hynynen, F. Jolesz MRI monitoring of the thermal ablation of tissue Effects of long exposure times J Magn Reson Imaging 13 3 2001 421 427
    • (2001) J Magn Reson Imaging , vol.13 , Issue.3 , pp. 421-427
    • McDannold, N.1    Hynynen, K.2    Jolesz, F.3
  • 15
    • 0036995128 scopus 로고    scopus 로고
    • Ultrasonic temperature imaging for the guidance of thermal ablation therapies: In vitro results
    • N.R. Miller, J.C. Bamber, G.R. ter Haar Ultrasonic temperature imaging for the guidance of thermal ablation therapies In vitro results Proc IEEE Ultrason Sympos 2 2002 1365 1368
    • (2002) Proc IEEE Ultrason Sympos , vol.2 , pp. 1365-1368
    • Miller, N.R.1    Bamber, J.C.2    Ter Haar, G.R.3
  • 16
    • 1542751253 scopus 로고    scopus 로고
    • Endovenous laser treatment of saphenous vein reflux
    • R.J. Min, N.M. Khilnani Endovenous laser treatment of saphenous vein reflux Tech Vasc Interv Radiol 6 3 2003 125 131
    • (2003) Tech Vasc Interv Radiol , vol.6 , Issue.3 , pp. 125-131
    • Min, R.J.1    Khilnani, N.M.2
  • 17
    • 0004260424 scopus 로고
    • Theory of thermoelasticity with applications
    • Sijthoff & Noordhoff Netherlands
    • J.L. Nowinski Theory of thermoelasticity with applications Alphen aan den Rijn 1978 Sijthoff & Noordhoff Netherlands
    • (1978) Alphen Aan Den Rijn
    • Nowinski, J.L.1
  • 18
    • 0025806883 scopus 로고
    • Elastography: A quantitative method for imaging the elasticity of biological tissues
    • J. Ophir, I. Céspedes, H. Ponnekanti Elastography A quantitative method for imaging the elasticity of biological tissues Ultrason Imaging 13 1991 111 134
    • (1991) Ultrason Imaging , vol.13 , pp. 111-134
    • Ophir, J.1    Céspedes, I.2    Ponnekanti, H.3
  • 19
    • 84888360034 scopus 로고
    • Analysis of tissue and arterial blood temperatures in resting forearm
    • H.H. Pennes Analysis of tissue and arterial blood temperatures in resting forearm J Appl Physiol 1 1948 93 122
    • (1948) J Appl Physiol , vol.1 , pp. 93-122
    • Pennes, H.H.1
  • 20
    • 0033276760 scopus 로고    scopus 로고
    • A time-efficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation
    • A. Pesavento, C. Perrey, M. Krueger A time-efficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation IEEE Trans Ultrason Ferroelec Freq Control 46 5 1999 1057 1067
    • (1999) IEEE Trans Ultrason Ferroelec Freq Control , vol.46 , Issue.5 , pp. 1057-1067
    • Pesavento, A.1    Perrey, C.2    Krueger, M.3
  • 21
    • 0032412292 scopus 로고    scopus 로고
    • Differential attenuation imaging for the characterization of high intensity focused ultrasound lesions
    • M. Ribault, J.Y. Chapelon, D. Cathignol Differential attenuation imaging for the characterization of high intensity focused ultrasound lesions Ultrason Imaging 20 3 1998 160 177
    • (1998) Ultrason Imaging , vol.20 , Issue.3 , pp. 160-177
    • Ribault, M.1    Chapelon, J.Y.2    Cathignol, D.3
  • 22
    • 0032876108 scopus 로고    scopus 로고
    • Elastographic characterization of HIFU-induced lesions in canine livers
    • R. Righetti, F. Kallel, R.J. Stafford Elastographic characterization of HIFU-induced lesions in canine livers Ultrasound Med Biol 25 7 1999 1099 1113
    • (1999) Ultrasound Med Biol , vol.25 , Issue.7 , pp. 1099-1113
    • Righetti, R.1    Kallel, F.2    Stafford, R.J.3
  • 24
    • 0029347489 scopus 로고
    • Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound
    • R. Seip, E.S. Ebbini Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound IEEE Trans Biomed Eng 42 8 1995 828 839
    • (1995) IEEE Trans Biomed Eng , vol.42 , Issue.8 , pp. 828-839
    • Seip, R.1    Ebbini, E.S.2
  • 25
    • 0032809552 scopus 로고    scopus 로고
    • Detection of high-intensity focused ultrasound liver lesions using dynamic elastometry
    • X. Shi, R.W. Martin, D. Rouseff Detection of high-intensity focused ultrasound liver lesions using dynamic elastometry Ultrason Imaging 21 2 1999 107 126
    • (1999) Ultrason Imaging , vol.21 , Issue.2 , pp. 107-126
    • Shi, X.1    Martin, R.W.2    Rouseff, D.3
  • 26
    • 0031365556 scopus 로고    scopus 로고
    • Quantitative analysis and applications of non-invasive temperature estimation using diagnostic ultrasound
    • C. Simon, P. VanBaren, E. Ebbini Quantitative analysis and applications of non-invasive temperature estimation using diagnostic ultrasound Proc IEEE Ultrason Sympos 2 1997 1319 1322
    • (1997) Proc IEEE Ultrason Sympos , vol.2 , pp. 1319-1322
    • Simon, C.1    Vanbaren, P.2    Ebbini, E.3
  • 27
    • 0037962058 scopus 로고    scopus 로고
    • Visualisation of HIFU lesions using elastography of the human prostate in vivo: Preliminary results
    • R. Souchon, O. Rouvière, A. Gelet Visualisation of HIFU lesions using elastography of the human prostate in vivo Preliminary results Ultrasound Med Biol 29 7 2003 1007 1015
    • (2003) Ultrasound Med Biol , vol.29 , Issue.7 , pp. 1007-1015
    • Souchon, R.1    Rouvière, O.2    Gelet, A.3
  • 28
    • 0037298609 scopus 로고    scopus 로고
    • A zero-crossing strain estimator for elastography
    • S. Srinivasan, J. Ophir A zero-crossing strain estimator for elastography Ultrasound Med Biol 29 2 2003 227 238
    • (2003) Ultrasound Med Biol , vol.29 , Issue.2 , pp. 227-238
    • Srinivasan, S.1    Ophir, J.2
  • 29
    • 0036821077 scopus 로고    scopus 로고
    • Elastographic imaging using staggered strain estimates
    • S. Srinivasan, J. Ophir, S.K. Alam Elastographic imaging using staggered strain estimates Ultrason Imaging 24 2002 229 245
    • (2002) Ultrason Imaging , vol.24 , pp. 229-245
    • Srinivasan, S.1    Ophir, J.2    Alam, S.K.3
  • 30
    • 0036821003 scopus 로고    scopus 로고
    • Temperature dependence of ultrasonic propagation speed and attenuation in canine tissue
    • U. Techavipoo, T. Varghese, J.A. Zagzebski Temperature dependence of ultrasonic propagation speed and attenuation in canine tissue Ultrason Imaging 24 2002 246 260
    • (2002) Ultrason Imaging , vol.24 , pp. 246-260
    • Techavipoo, U.1    Varghese, T.2    Zagzebski, J.A.3
  • 31
    • 0034949394 scopus 로고    scopus 로고
    • High intensity focused ultrasound for the treatment of tumors
    • G.R. ter Haar High intensity focused ultrasound for the treatment of tumors Echocardiography 18 4 2001 317 322
    • (2001) Echocardiography , vol.18 , Issue.4 , pp. 317-322
    • Ter Haar, G.R.1
  • 32
    • 0036222555 scopus 로고    scopus 로고
    • Ultrasound monitoring of temperature change during radiofrequency ablation--Preliminary in-vivo results
    • T. Varghese, J.A. Zagzebski, Q. Chen Ultrasound monitoring of temperature change during radiofrequency ablation--Preliminary in-vivo results Ultrasound Med Biol 28 3 2002 321 329
    • (2002) Ultrasound Med Biol , vol.28 , Issue.3 , pp. 321-329
    • Varghese, T.1    Zagzebski, J.A.2    Chen, Q.3
  • 33
    • 0041590978 scopus 로고    scopus 로고
    • Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation
    • C. Weidensteiner, B. Quesson, B. Caire-Gana Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation Magn Reson Med 50 2 2003 322 330
    • (2003) Magn Reson Med , vol.50 , Issue.2 , pp. 322-330
    • Weidensteiner, C.1    Quesson, B.2    Caire-Gana, B.3
  • 34
    • 0035158496 scopus 로고    scopus 로고
    • Assessment of thermal tissue ablation with MR elastography
    • T. Wu, J.P. Felmlee, J.F. Greenleaf Assessment of thermal tissue ablation with MR elastography Magn Reson Med 45 2001 80 87
    • (2001) Magn Reson Med , vol.45 , pp. 80-87
    • Wu, T.1    Felmlee, J.P.2    Greenleaf, J.F.3
  • 35
    • 0036663802 scopus 로고    scopus 로고
    • A modified block matching method for real-time freehand strain imaging
    • Y. Zhu, T.J. Hall A modified block matching method for real-time freehand strain imaging Ultrason Imaging 24 3 2002 161 176
    • (2002) Ultrason Imaging , vol.24 , Issue.3 , pp. 161-176
    • Zhu, Y.1    Hall, T.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.