Volumn 34, Issue 4, 2008, Pages 607-616

Dual-Mode Ultrasound Transducer for Image-Guided Interstitial Thermal Therapy

Author keywords

Dual mode; Interstitial therapy; Ultrasound transducer

Indexed keywords

ACOUSTIC WAVE PROPAGATION; MEDICAL IMAGING; PATIENT MONITORING; PATIENT TREATMENT; TUMORS; ULTRASONIC DEVICES;

EID: 40949122319     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2007.09.011     Document Type: Article
Times cited : (36)

References (30)
  • 1
    • 2942715060 scopus 로고    scopus 로고
    • Monitoring formation of high intensity focused ultrasound (HIFU) induced lesions using backscattered ultrasound
    • Anand A., and Kaczkowski P. Monitoring formation of high intensity focused ultrasound (HIFU) induced lesions using backscattered ultrasound. ARLO 5 (2004) 88-94
    • (2004) ARLO , vol.5 , pp. 88-94
    • Anand, A.1    Kaczkowski, P.2
  • 4
    • 27144556951 scopus 로고    scopus 로고
    • Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators
    • Chopra R., Burtnyk M., Haider M.A., and Bronskill M.J. Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators. Phys Med Biol 50 (2005) 4957-4975
    • (2005) Phys Med Biol , vol.50 , pp. 4957-4975
    • Chopra, R.1    Burtnyk, M.2    Haider, M.A.3    Bronskill, M.J.4
  • 5
    • 0001814584 scopus 로고
    • Ultrasonic power balances
    • Preston R.C. (Ed), Springer Verlag, Berlin
    • Davidson F. Ultrasonic power balances. In: Preston R.C. (Ed). Output Measurements for Medical Ultrasound (1991), Springer Verlag, Berlin 55
    • (1991) Output Measurements for Medical Ultrasound , pp. 55
    • Davidson, F.1
  • 6
    • 4444384019 scopus 로고    scopus 로고
    • Radiofrequency ablation of liver tumours: Systematic review
    • Decadt B., and Siriwardena A.K. Radiofrequency ablation of liver tumours: Systematic review. Lancet Oncol 5 (2004) 550-560
    • (2004) Lancet Oncol , vol.5 , pp. 550-560
    • Decadt, B.1    Siriwardena, A.K.2
  • 7
    • 0942286911 scopus 로고    scopus 로고
    • Transurethral ultrasound applicators with directional heating patterns for prostate thermal therapy: In vivo evaluation using magnetic resonance thermometry
    • Diederich C., Stafford R., Nau W., Burdette E., Price R., and Hazle J. Transurethral ultrasound applicators with directional heating patterns for prostate thermal therapy: In vivo evaluation using magnetic resonance thermometry. Med Phys 31 (2004) 405-413
    • (2004) Med Phys , vol.31 , pp. 405-413
    • Diederich, C.1    Stafford, R.2    Nau, W.3    Burdette, E.4    Price, R.5    Hazle, J.6
  • 8
    • 8744255879 scopus 로고    scopus 로고
    • Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostate
    • Diederich C.J., Nau W.H., Ross A.B., Tyreus P.D., Butts K., Rieke V., and Sommer G. Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostate. Int J Hyperthermia 20 (2004) 739-756
    • (2004) Int J Hyperthermia , vol.20 , pp. 739-756
    • Diederich, C.J.1    Nau, W.H.2    Ross, A.B.3    Tyreus, P.D.4    Butts, K.5    Rieke, V.6    Sommer, G.7
  • 9
    • 33750723510 scopus 로고    scopus 로고
    • Dual-mode ultrasound phased arrays for image-guided surgery
    • Ebbini S.E., Yao H., and Shrestha A. Dual-mode ultrasound phased arrays for image-guided surgery. Ultrasonic Imag 28 (2006) 65-82
    • (2006) Ultrasonic Imag , vol.28 , pp. 65-82
    • Ebbini, S.E.1    Yao, H.2    Shrestha, A.3
  • 10
    • 1842611882 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging of thermally- and chemically-induced lesions in soft tissues: Preliminary ex vivo results
    • Fahey B.J., Nightingale K.R., Stutz D.L., and Trahey G.E. Acoustic radiation force impulse imaging of thermally- and chemically-induced lesions in soft tissues: Preliminary ex vivo results. Ultrasound Med Biol 30 (2004) 321-328
    • (2004) Ultrasound Med Biol , vol.30 , pp. 321-328
    • Fahey, B.J.1    Nightingale, K.R.2    Stutz, D.L.3    Trahey, G.E.4
  • 15
    • 0032992274 scopus 로고    scopus 로고
    • Theoretical comparison of two interstitial ultrasound applicators designed to induce cylindrical zones of tissue ablation
    • Lafon C., Chavrier F., Prat F., Chapelon J., and Cathignol D. Theoretical comparison of two interstitial ultrasound applicators designed to induce cylindrical zones of tissue ablation. Med Biol Eng Comput 37 (1999) 298-303
    • (1999) Med Biol Eng Comput , vol.37 , pp. 298-303
    • Lafon, C.1    Chavrier, F.2    Prat, F.3    Chapelon, J.4    Cathignol, D.5
  • 16
    • 0033663650 scopus 로고    scopus 로고
    • Cylindrical thermal coagulation necrosis using an interstitial applicator with a plane ultrasonic transducer: In vitro and in vivo experiments versus computer simulation
    • Lafon C., Prat F., Chapelon J.Y., Gorry F., Margonari J., Theillère Y., and Cathignol D. Cylindrical thermal coagulation necrosis using an interstitial applicator with a plane ultrasonic transducer: In vitro and in vivo experiments versus computer simulation. Int J of Hyperthermia 16 6 (2000) 508-522
    • (2000) Int J of Hyperthermia , vol.16 , Issue.6 , pp. 508-522
    • Lafon, C.1    Prat, F.2    Chapelon, J.Y.3    Gorry, F.4    Margonari, J.5    Theillère, Y.6    Cathignol, D.7
  • 17
    • 0033121876 scopus 로고    scopus 로고
    • Study of polymer ultrasound transducer and complex ultrasonic transducer with PZT/PVDF multi-layer structure
    • Liu X.Z., Ye S., Gong X., Zhang W., and Lu R. Study of polymer ultrasound transducer and complex ultrasonic transducer with PZT/PVDF multi-layer structure. Acustica 85 3 (1999) 420-426
    • (1999) Acustica , vol.85 , Issue.3 , pp. 420-426
    • Liu, X.Z.1    Ye, S.2    Gong, X.3    Zhang, W.4    Lu, R.5
  • 20
    • 0037298654 scopus 로고    scopus 로고
    • Transoesophageal ultrasound applicator for sector-based thermal ablation: First in vivo experiments
    • Melodelima D., Lafon C., Prat F., Theillère Y., Arefiev A., and Cathignol D. Transoesophageal ultrasound applicator for sector-based thermal ablation: First in vivo experiments. Ultrasound Med Biol 29 (2003) 285-291
    • (2003) Ultrasound Med Biol , vol.29 , pp. 285-291
    • Melodelima, D.1    Lafon, C.2    Prat, F.3    Theillère, Y.4    Arefiev, A.5    Cathignol, D.6
  • 21
    • 33746638743 scopus 로고    scopus 로고
    • 64-element intraluminal ultrasound cylindrical phased array for transesophageal thermal ablation under fast MR temperature mapping: An ex vivo study
    • Melodelima D., Salomir R., Mougenot C., Moonen C., and Cathignol D. 64-element intraluminal ultrasound cylindrical phased array for transesophageal thermal ablation under fast MR temperature mapping: An ex vivo study. Med Phys 33 (2006) 2926-2934
    • (2006) Med Phys , vol.33 , pp. 2926-2934
    • Melodelima, D.1    Salomir, R.2    Mougenot, C.3    Moonen, C.4    Cathignol, D.5
  • 23
    • 0036998412 scopus 로고    scopus 로고
    • Endoscopic treatment of cholangiocarcinoma and carcinoma of the duodenal papilla by intraductal high-intensity US: Results of a pilot study
    • Prat F., Lafon C., Melodelima D., Theillière Y., Fritsch J., Pelletier G., Buffet C., and Cathignol D. Endoscopic treatment of cholangiocarcinoma and carcinoma of the duodenal papilla by intraductal high-intensity US: Results of a pilot study. Gastrointest Endosc 56 (2002) 909-915
    • (2002) Gastrointest Endosc , vol.56 , pp. 909-915
    • Prat, F.1    Lafon, C.2    Melodelima, D.3    Theillière, Y.4    Fritsch, J.5    Pelletier, G.6    Buffet, C.7    Cathignol, D.8
  • 24
    • 1642617291 scopus 로고    scopus 로고
    • Thermo-mechanical stress effect on 1-3 piezocomposite power transducer performance
    • Richard C., Lee H.S., and Guyomar D. Thermo-mechanical stress effect on 1-3 piezocomposite power transducer performance. Ultrasonics 42 (2004) 417-424
    • (2004) Ultrasonics , vol.42 , pp. 417-424
    • Richard, C.1    Lee, H.S.2    Guyomar, D.3
  • 25
    • 0030290061 scopus 로고    scopus 로고
    • Computer optimization of transducer transfer functions using constraints on bandwidth, ripple, and loss
    • Rhyne T.L. Computer optimization of transducer transfer functions using constraints on bandwidth, ripple, and loss. IEEE Trans Ultrason Ferroelectr Freq Control 43 (1996) 1136-1149
    • (1996) IEEE Trans Ultrason Ferroelectr Freq Control , vol.43 , pp. 1136-1149
    • Rhyne, T.L.1
  • 26
    • 0033083007 scopus 로고    scopus 로고
    • Percutaneous microwave coagulation therapy for solitary metastatic liver tumors from colorectal cancer: A pilot clinical study
    • Seki T., Wakabayashi M., Nakagawa T., Imamura M., Tamai T., Nishimura A., Yamashiki N., and Inoue K. Percutaneous microwave coagulation therapy for solitary metastatic liver tumors from colorectal cancer: A pilot clinical study. Am J Gastroenterol 94 (1999) 322-327
    • (1999) Am J Gastroenterol , vol.94 , pp. 322-327
    • Seki, T.1    Wakabayashi, M.2    Nakagawa, T.3    Imamura, M.4    Tamai, T.5    Nishimura, A.6    Yamashiki, N.7    Inoue, K.8
  • 27
    • 0024872082 scopus 로고
    • The role of piezocomposites in ultrasonic transducers
    • Smith W. The role of piezocomposites in ultrasonic transducers. Ultrason Symp 2 (1989) 755-766
    • (1989) Ultrason Symp , vol.2 , pp. 755-766
    • Smith, W.1
  • 29
    • 0034998299 scopus 로고    scopus 로고
    • Laser-induced thermotherapy of malignant liver tumors: General principals, equipment(s), procedure(s) -side effects, complications and results
    • Vogl T.J., Eichler K., Straub R., Engelmann K., Zangos S., Woitaschek D., Böttger M., and Mack M.G. Laser-induced thermotherapy of malignant liver tumors: General principals, equipment(s), procedure(s) -side effects, complications and results. Eur J Ultrasound 13 (2001) 117-127
    • (2001) Eur J Ultrasound , vol.13 , pp. 117-127
    • Vogl, T.J.1    Eichler, K.2    Straub, R.3    Engelmann, K.4    Zangos, S.5    Woitaschek, D.6    Böttger, M.7    Mack, M.G.8
  • 30
    • 0035324495 scopus 로고    scopus 로고
    • Discussion of one-D piezoelectric transducer models with loss
    • Whitworth G. Discussion of one-D piezoelectric transducer models with loss. IEEE Trans Ultrason Ferroelectr Freq Control 48 (2001) 844-846
    • (2001) IEEE Trans Ultrason Ferroelectr Freq Control , vol.48 , pp. 844-846
    • Whitworth, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.