메뉴 건너뛰기




Volumn 40, Issue 3, 2009, Pages 240-244

Use of a "hybrid" locking plate for complex metaphyseal fractures and nonunions about the humerus

Author keywords

Humerus fracture; Hybrid; Locked plate; Metaphyseal; Novel

Indexed keywords

ADULT; AGED; ARTICLE; BONE PLATE; BONE RADIOGRAPHY; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FRACTURE FIXATION; FRACTURE HEALING; FRACTURE NONUNION; HUMAN; HUMERUS FRACTURE; MALE; METAPHYSIS; PRIORITY JOURNAL; RANGE OF MOTION; ADOLESCENT; BONE SCREW; DEVICES; FRACTURES, UNUNITED; HUMERAL FRACTURES; JOINT CHARACTERISTICS AND FUNCTIONS; MIDDLE AGED; OSTEOSYNTHESIS; PATHOPHYSIOLOGY; PHYSIOLOGY; PROCEDURES; RADIOGRAPHY; RETROSPECTIVE STUDY; TREATMENT OUTCOME; WEIGHT BEARING; YOUNG ADULT;

EID: 61549124730     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2008.07.019     Document Type: Article
Times cited : (33)

References (38)
  • 1
    • 0021950634 scopus 로고
    • The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience
    • Bell M.J., Beauchamp C.G., Kellam J.K., and McMurtry R.Y. The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. J Bone Joint Surg Br 67 2 (1985) 293-296
    • (1985) J Bone Joint Surg Br , vol.67 , Issue.2 , pp. 293-296
    • Bell, M.J.1    Beauchamp, C.G.2    Kellam, J.K.3    McMurtry, R.Y.4
  • 2
    • 33646905915 scopus 로고    scopus 로고
    • The use of locking plates in fracture care
    • Cantu R.V., and Koval K.J. The use of locking plates in fracture care. J Am Acad Orthop Surg 14 3 (2006) 183-190
    • (2006) J Am Acad Orthop Surg , vol.14 , Issue.3 , pp. 183-190
    • Cantu, R.V.1    Koval, K.J.2
  • 3
    • 0034152245 scopus 로고    scopus 로고
    • Randomized prospective study of humeral shaft fracture fixation: intramedullary nails versus plates
    • Chapman J.R., Henley M.B., Agel J., and Benca P.J. Randomized prospective study of humeral shaft fracture fixation: intramedullary nails versus plates. J Orthop Trauma 14 3 (2000) 162-166
    • (2000) J Orthop Trauma , vol.14 , Issue.3 , pp. 162-166
    • Chapman, J.R.1    Henley, M.B.2    Agel, J.3    Benca, P.J.4
  • 4
    • 38449107213 scopus 로고    scopus 로고
    • Clinical results of minimal screw plate fixation of forearm fractures
    • Crow B.D., Mundis G., and Anglen J.O. Clinical results of minimal screw plate fixation of forearm fractures. Am J Orthop 36 9 (2007) 477-480
    • (2007) Am J Orthop , vol.36 , Issue.9 , pp. 477-480
    • Crow, B.D.1    Mundis, G.2    Anglen, J.O.3
  • 5
    • 0033126760 scopus 로고    scopus 로고
    • Complications of intramedullary nailing for fractures of the humeral shaft: a review
    • Farragos A.F., Schemitsch E.H., and McKee M.D. Complications of intramedullary nailing for fractures of the humeral shaft: a review. J Orthop Trauma 13 4 (1999) 258-267
    • (1999) J Orthop Trauma , vol.13 , Issue.4 , pp. 258-267
    • Farragos, A.F.1    Schemitsch, E.H.2    McKee, M.D.3
  • 6
    • 33748453701 scopus 로고    scopus 로고
    • Hybrid locked plating of osteoporotic fractures of the humerus
    • Gardner M.J., Griffith M.H., Demetrakopoulos D., et al. Hybrid locked plating of osteoporotic fractures of the humerus. J Bone Joint Surg Am 88 9 (2006) 1962-1967
    • (2006) J Bone Joint Surg Am , vol.88 , Issue.9 , pp. 1962-1967
    • Gardner, M.J.1    Griffith, M.H.2    Demetrakopoulos, D.3
  • 7
    • 0142138198 scopus 로고    scopus 로고
    • Guidelines for the clinical application of the LCP
    • Gautier E., and Sommer C. Guidelines for the clinical application of the LCP. Injury 34 Suppl. 2 (2003) B63-76
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Gautier, E.1    Sommer, C.2
  • 8
    • 33847727840 scopus 로고    scopus 로고
    • Locking plate technology: current concepts
    • Greiwe R.M., and Archdeacon M.T. Locking plate technology: current concepts. J Knee Surg 20 1 (2007) 50-55
    • (2007) J Knee Surg , vol.20 , Issue.1 , pp. 50-55
    • Greiwe, R.M.1    Archdeacon, M.T.2
  • 9
    • 33750812273 scopus 로고    scopus 로고
    • Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation
    • Jawa A., McCarty P., Doornberg J., Harris M., and Ring D. Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation. J Bone Joint Surg Am 88 11 (2006) 2343-2347
    • (2006) J Bone Joint Surg Am , vol.88 , Issue.11 , pp. 2343-2347
    • Jawa, A.1    McCarty, P.2    Doornberg, J.3    Harris, M.4    Ring, D.5
  • 10
    • 34547813191 scopus 로고    scopus 로고
    • Minimally invasive plating for complex humeral shaft fractures
    • Jiang R., Luo C.F., Zeng B.F., and Mei G.H. Minimally invasive plating for complex humeral shaft fractures. Arch Orthop Trauma Surg 127 7 (2007) 531-535
    • (2007) Arch Orthop Trauma Surg , vol.127 , Issue.7 , pp. 531-535
    • Jiang, R.1    Luo, C.F.2    Zeng, B.F.3    Mei, G.H.4
  • 12
    • 0142138199 scopus 로고    scopus 로고
    • The LCP-concept in the operative treatment of distal humerus fractures-biological, biomechanical and surgical aspects
    • Korner J., Lill H., Muller L.P., Rommens P.M., Schneider E., and Linke B. The LCP-concept in the operative treatment of distal humerus fractures-biological, biomechanical and surgical aspects. Injury 34 Suppl. 2 (2003) B20-30
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Korner, J.1    Lill, H.2    Muller, L.P.3    Rommens, P.M.4    Schneider, E.5    Linke, B.6
  • 13
    • 0030004494 scopus 로고    scopus 로고
    • Surgical neck fractures of the proximal humerus: a laboratory evaluation of ten fixation techniques
    • Koval K.J., Blair B., Takei R., Kummer F.J., and Zuckerman J.D. Surgical neck fractures of the proximal humerus: a laboratory evaluation of ten fixation techniques. J Trauma 40 5 (1996) 778-783
    • (1996) J Trauma , vol.40 , Issue.5 , pp. 778-783
    • Koval, K.J.1    Blair, B.2    Takei, R.3    Kummer, F.J.4    Zuckerman, J.D.5
  • 14
    • 34249708441 scopus 로고    scopus 로고
    • Locking plate technology and its applications in upper extremity fracture care
    • vii
    • Larson A.N., and Rizzo M. Locking plate technology and its applications in upper extremity fracture care. Hand Clin 23 2 (2007) 269-278 vii
    • (2007) Hand Clin , vol.23 , Issue.2 , pp. 269-278
    • Larson, A.N.1    Rizzo, M.2
  • 15
    • 37849040165 scopus 로고    scopus 로고
    • Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures
    • Lever J.P., Aksenov S.A., Zdero R., Ahn H., McKee M.D., and Schemitsch E.H. Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures. J Orthop Trauma 22 1 (2008) 23-29
    • (2008) J Orthop Trauma , vol.22 , Issue.1 , pp. 23-29
    • Lever, J.P.1    Aksenov, S.A.2    Zdero, R.3    Ahn, H.4    McKee, M.D.5    Schemitsch, E.H.6
  • 16
    • 0034098148 scopus 로고    scopus 로고
    • Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail. A prospective, randomised trial
    • McCormack R.G., Brien D., Buckley R.E., McKee M.D., Powell J., and Schemitsch E.H. Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail. A prospective, randomised trial. J Bone Joint Surg Br 82 3 (2000) 336-339
    • (2000) J Bone Joint Surg Br , vol.82 , Issue.3 , pp. 336-339
    • McCormack, R.G.1    Brien, D.2    Buckley, R.E.3    McKee, M.D.4    Powell, J.5    Schemitsch, E.H.6
  • 17
    • 0029557994 scopus 로고
    • The application of the limited contact dynamic compression plate in the upper extremity: an analysis of 114 consecutive cases
    • McKee M.D., Seiler J.G., and Jupiter J.B. The application of the limited contact dynamic compression plate in the upper extremity: an analysis of 114 consecutive cases. Injury 26 10 (1995) 661-666
    • (1995) Injury , vol.26 , Issue.10 , pp. 661-666
    • McKee, M.D.1    Seiler, J.G.2    Jupiter, J.B.3
  • 18
    • 0031912864 scopus 로고    scopus 로고
    • Operative management of diaphyseal fractures of the humerus. Plate versus nail
    • Modabber M.R., and Jupiter J.B. Operative management of diaphyseal fractures of the humerus. Plate versus nail. Clin Orthop Relat Res 347 (1998) 93-104
    • (1998) Clin Orthop Relat Res , vol.347 , pp. 93-104
    • Modabber, M.R.1    Jupiter, J.B.2
  • 19
    • 0036854433 scopus 로고    scopus 로고
    • Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology
    • Perren S.M. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84 8 (2002) 1093-1110
    • (2002) J Bone Joint Surg Br , vol.84 , Issue.8 , pp. 1093-1110
    • Perren, S.M.1
  • 20
    • 0038351051 scopus 로고    scopus 로고
    • Unstable nonunions of the distal part of the humerus
    • Ring D., Gulotta L., and Jupiter J.B. Unstable nonunions of the distal part of the humerus. J Bone Joint Surg Am 85-A 6 (2003) 1040-1046
    • (2003) J Bone Joint Surg Am , vol.85 -A , Issue.6 , pp. 1040-1046
    • Ring, D.1    Gulotta, L.2    Jupiter, J.B.3
  • 21
    • 0037355886 scopus 로고    scopus 로고
    • Ununited diaphyseal fractures of the humerus: techniques for fixation of osteoporotic bone
    • Ring D., and Jupiter J. Ununited diaphyseal fractures of the humerus: techniques for fixation of osteoporotic bone. Tech Hand Up Extrem Surg 7 1 (2003) 2-6
    • (2003) Tech Hand Up Extrem Surg , vol.7 , Issue.1 , pp. 2-6
    • Ring, D.1    Jupiter, J.2
  • 22
    • 0032603244 scopus 로고    scopus 로고
    • Complex fractures of the distal humerus and their complications
    • Ring D., and Jupiter J.B. Complex fractures of the distal humerus and their complications. J Shoulder Elbow Surg 8 1 (1999) 85-97
    • (1999) J Shoulder Elbow Surg , vol.8 , Issue.1 , pp. 85-97
    • Ring, D.1    Jupiter, J.B.2
  • 23
    • 4043112149 scopus 로고    scopus 로고
    • Locking compression plates for osteoporotic nonunions of the diaphyseal humerus
    • Ring D., Kloen P., Kadzielski J., Helfet D., and Jupiter J.B. Locking compression plates for osteoporotic nonunions of the diaphyseal humerus. Clin Orthop Relat Res 425 (2004) 50-54
    • (2004) Clin Orthop Relat Res , vol.425 , pp. 50-54
    • Ring, D.1    Kloen, P.2    Kadzielski, J.3    Helfet, D.4    Jupiter, J.B.5
  • 26
    • 0036198119 scopus 로고    scopus 로고
    • Minimal versus maximal plate fixation techniques of the ulna: the biomechanical effect of number of screws and plate length
    • Sanders R., Haidukewych G.J., Milne T., Dennis J., and Latta L.L. Minimal versus maximal plate fixation techniques of the ulna: the biomechanical effect of number of screws and plate length. J Orthop Trauma 16 3 (2002) 166-171
    • (2002) J Orthop Trauma , vol.16 , Issue.3 , pp. 166-171
    • Sanders, R.1    Haidukewych, G.J.2    Milne, T.3    Dennis, J.4    Latta, L.L.5
  • 27
    • 0346310448 scopus 로고    scopus 로고
    • Revolution in plate osteosynthesis: new internal fixator systems
    • Schutz M., and Sudkamp N.P. Revolution in plate osteosynthesis: new internal fixator systems. J Orthop Sci 8 2 (2003) 252-258
    • (2003) J Orthop Sci , vol.8 , Issue.2 , pp. 252-258
    • Schutz, M.1    Sudkamp, N.P.2
  • 29
    • 0142230911 scopus 로고    scopus 로고
    • First clinical results of the locking compression plate (LCP)
    • Sommer C., Gautier E., Muller M., Helfet D.L., and Wagner M. First clinical results of the locking compression plate (LCP). Injury 34 Suppl. 2 (2003) B43-54
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Sommer, C.1    Gautier, E.2    Muller, M.3    Helfet, D.L.4    Wagner, M.5
  • 30
    • 0242659165 scopus 로고    scopus 로고
    • Intramedullary nailing of humeral shaft fractures with a locking flexible nail
    • Stannard J.P., Harris H.W., McGwin Jr. G., Volgas D.A., and Alonso J.E. Intramedullary nailing of humeral shaft fractures with a locking flexible nail. J Bone Joint Surg Am 85-A 11 (2003) 2103-2110
    • (2003) J Bone Joint Surg Am , vol.85 -A , Issue.11 , pp. 2103-2110
    • Stannard, J.P.1    Harris, H.W.2    McGwin Jr., G.3    Volgas, D.A.4    Alonso, J.E.5
  • 31
    • 16644362839 scopus 로고    scopus 로고
    • Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium
    • Stoffel K., Stachowiak G., Forster T., Gachter A., and Kuster M. Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium. J Orthop Trauma 18 9 (2004) 611-616
    • (2004) J Orthop Trauma , vol.18 , Issue.9 , pp. 611-616
    • Stoffel, K.1    Stachowiak, G.2    Forster, T.3    Gachter, A.4    Kuster, M.5
  • 32
    • 0032884781 scopus 로고    scopus 로고
    • Short musculoskeletal function assessment questionnaire: validity, reliability, and responsiveness
    • Swiontkowski M.F., Engelberg R., Martin D.P., and Agel J. Short musculoskeletal function assessment questionnaire: validity, reliability, and responsiveness. J Bone Joint Surg Am 81 9 (1999) 1245-1260
    • (1999) J Bone Joint Surg Am , vol.81 , Issue.9 , pp. 1245-1260
    • Swiontkowski, M.F.1    Engelberg, R.2    Martin, D.P.3    Agel, J.4
  • 33
    • 0029692879 scopus 로고    scopus 로고
    • The strength of plate fixation in relation to the number and spacing of bone screws
    • Tornkvist H., Hearn T.C., and Schatzker J. The strength of plate fixation in relation to the number and spacing of bone screws. J Orthop Trauma 10 3 (1996) 204-208
    • (1996) J Orthop Trauma , vol.10 , Issue.3 , pp. 204-208
    • Tornkvist, H.1    Hearn, T.C.2    Schatzker, J.3
  • 34
    • 33645666369 scopus 로고    scopus 로고
    • Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases
    • Vallier H.A., Hennessey T.A., Sontich J.K., and Patterson B.M. Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases. J Bone Joint Surg Am 88 4 (2006) 846-853
    • (2006) J Bone Joint Surg Am , vol.88 , Issue.4 , pp. 846-853
    • Vallier, H.A.1    Hennessey, T.A.2    Sontich, J.K.3    Patterson, B.M.4
  • 35
    • 0022653509 scopus 로고
    • Open reduction and internal fixation of humeral shaft fractures. Results using AO plating techniques
    • Vander Griend R., Tomasin J., and Ward E.F. Open reduction and internal fixation of humeral shaft fractures. Results using AO plating techniques. J Bone Joint Surg Am 68 3 (1986) 430-433
    • (1986) J Bone Joint Surg Am , vol.68 , Issue.3 , pp. 430-433
    • Vander Griend, R.1    Tomasin, J.2    Ward, E.F.3
  • 36
    • 0142199888 scopus 로고    scopus 로고
    • General principles for the clinical use of the LCP
    • Wagner M. General principles for the clinical use of the LCP. Injury 34 Suppl. 2 (2003) B31-42
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Wagner, M.1
  • 37
    • 16644403465 scopus 로고    scopus 로고
    • New concepts for bone fracture treatment and the Locking Compression Plate
    • Wagner M., Frenk A., and Frigg R. New concepts for bone fracture treatment and the Locking Compression Plate. Surg Technol Int 12 (2004) 271-277
    • (2004) Surg Technol Int , vol.12 , pp. 271-277
    • Wagner, M.1    Frenk, A.2    Frigg, R.3
  • 38
    • 40949100776 scopus 로고    scopus 로고
    • Locked versus unlocked plating with respect to plate length in an ulna fracture model
    • Weiss D.B., Kaar S.G., Frankenburg E.P., and Karunakar M.A. Locked versus unlocked plating with respect to plate length in an ulna fracture model. Bull NYU Hosp Joint Dis 66 1 (2008) 5-8
    • (2008) Bull NYU Hosp Joint Dis , vol.66 , Issue.1 , pp. 5-8
    • Weiss, D.B.1    Kaar, S.G.2    Frankenburg, E.P.3    Karunakar, M.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.