메뉴 건너뛰기




Volumn 127, Issue 7, 2007, Pages 531-535

Minimally invasive plating for complex humeral shaft fractures

Author keywords

Humeral shaft fracture; Minimal invasive plate osteosynthesis; Plate osteosynthesis

Indexed keywords

ADULT; ARTICLE; BONE PLATE; BONE RADIOGRAPHY; CLINICAL ARTICLE; CLINICAL EXAMINATION; CONTROLLED STUDY; ELBOW; FEMALE; FOLLOW UP; FRACTURE HEALING; FRACTURE NONUNION; HUMAN; HUMERUS FRACTURE; INFECTION; JOINT FUNCTION; MALE; MINIMALLY INVASIVE SURGERY; OLECRANON FRACTURE; OSTEOSYNTHESIS; OUTCOME ASSESSMENT; PRIORITY JOURNAL; SCORING SYSTEM; SHOULDER; SURGICAL TECHNIQUE;

EID: 34547813191     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-007-0313-z     Document Type: Article
Times cited : (65)

References (18)
  • 1
    • 14744300697 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report
    • Apivatthakakul T, Arpornchayanon O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report. Injury 36:530-538
    • (2005) Injury , vol.36 , pp. 530-538
    • Apivatthakakul, T.1    Arpornchayanon, O.2    Bavornratanavech, S.3
  • 2
    • 0021950634 scopus 로고
    • The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience
    • Bell MJ, Beauchamp CG, Kellam JK, McMurtry RY (1985) The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. J Bone Joint Surg Br 67:293-296
    • (1985) J Bone Joint Surg Br , vol.67 , pp. 293-296
    • Bell, M.J.1    Beauchamp, C.G.2    Kellam, J.K.3    McMurtry, R.Y.4
  • 3
    • 0036799950 scopus 로고    scopus 로고
    • Fixation stability of comminuted humeral shaft fractures: Locked intramedullary nailing versus plate fixation
    • Chen AL, Joseph TN, Wolinksy PR, Tejwani NC, Kummer FJ, Egol KA, Koval KJ (2002) Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation. J Trauma 53:733-737
    • (2002) J Trauma , vol.53 , pp. 733-737
    • Chen, A.L.1    Joseph, T.N.2    Wolinksy, P.R.3    Tejwani, N.C.4    Kummer, F.J.5    Egol, K.A.6    Koval, K.J.7
  • 4
    • 0023115201 scopus 로고
    • A clinical method of functional assessment of the shoulder
    • Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160-164
    • (1987) Clin Orthop Relat Res , vol.214 , pp. 160-164
    • Constant, C.R.1    Murley, A.H.2
  • 5
    • 0033126760 scopus 로고    scopus 로고
    • Complications of intramedullary nailing for fractures of the humeral shaft: A review
    • Farragos AF, Schemitsch EH, McKee MD (1999) Complications of intramedullary nailing for fractures of the humeral shaft: A review. J Orthop Trauma 13:258-267
    • (1999) J Orthop Trauma , vol.13 , pp. 258-267
    • Farragos, A.F.1    Schemitsch, E.H.2    McKee, M.D.3
  • 7
    • 0017076151 scopus 로고
    • Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: Retrospective and prospective analysis
    • Gustilo RB, Anderson JT (1976) Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analysis. J Bone Joint Surg Am 58:453-458
    • (1976) J Bone Joint Surg Am , vol.58 , pp. 453-458
    • Gustilo, R.B.1    Anderson, J.T.2
  • 8
    • 0142138198 scopus 로고    scopus 로고
    • Guidelines for the clinical application of the LCP
    • Gautier E, Sommer C (2003) Guidelines for the clinical application of the LCP. Injury 34(Suppl 2):B63-76
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Gautier, E.1    Sommer, C.2
  • 9
    • 0027296544 scopus 로고
    • Surgical treatment of humeral shaft fractures - The Basel experience
    • Heim D, Herkert F, Hess P, Regazzoni P (1993) Surgical treatment of humeral shaft fractures - the Basel experience. J Trauma 35:226-232
    • (1993) J Trauma , vol.35 , pp. 226-232
    • Heim, D.1    Herkert, F.2    Hess, P.3    Regazzoni, P.4
  • 10
    • 0030800805 scopus 로고    scopus 로고
    • Treatment of humeral shaft fractures by retrograde locked nailing
    • Lin J, Hou SM, Hang YS, Chao EY (1997) Treatment of humeral shaft fractures by retrograde locked nailing. Clin Orthop Relat Res 342:147-155
    • (1997) Clin Orthop Relat Res , vol.342 , pp. 147-155
    • Lin, J.1    Hou, S.M.2    Hang, Y.S.3    Chao, E.Y.4
  • 11
    • 0037234027 scopus 로고    scopus 로고
    • Locked nailing of severely comminuted or segmental humeral fractures
    • Lin J, Hou SM (2003) Locked nailing of severely comminuted or segmental humeral fractures. Clin Orthop Relat Res 406:195-204
    • (2003) Clin Orthop Relat Res , vol.406 , pp. 195-204
    • Lin, J.1    Hou, S.M.2
  • 12
    • 2342515286 scopus 로고    scopus 로고
    • Bridging plate osteosynthesis of humeral shaft fractures
    • Livani B, Belangero WD (2004) Bridging plate osteosynthesis of humeral shaft fractures. Injury 35:587-595
    • (2004) Injury , vol.35 , pp. 587-595
    • Livani, B.1    Belangero, W.D.2
  • 13
    • 0025086070 scopus 로고
    • The treatment of nonunions and pseudarthroses of the humeral shaft
    • Rosen H (1990) The treatment of nonunions and pseudarthroses of the humeral shaft. Orthop Clin North Am 21:725-742
    • (1990) Orthop Clin North Am , vol.21 , pp. 725-742
    • Rosen, H.1
  • 14
    • 0001920572 scopus 로고
    • The vascular response of bone to internal fixation
    • In: Browner BD, Edwards CC (eds) Lea & Febiger, Philadelphia
    • Rhinelander FW (1987) The vascular response of bone to internal fixation. In: Browner BD, Edwards CC (eds) The science and practice of intramedullary nailing. Lea & Febiger, Philadelphia, pp 25-60
    • (1987) The Science and Practice of Intramedullary Nailing , pp. 25-60
    • Rhinelander, F.W.1
  • 15
    • 12244250402 scopus 로고    scopus 로고
    • Mechanical effects of the locked screw plate interface in internal fixator osteosyntheses
    • Seide K, Morlock MM, Schümann U (1999) Mechanical effects of the locked screw plate interface in internal fixator osteosyntheses. Trauma Berufskrankh 1:320-325
    • (1999) Trauma Berufskrankh , vol.1 , pp. 320-325
    • Seide, K.1    Morlock, M.M.2    Schümann, U.3
  • 16
    • 29444461184 scopus 로고    scopus 로고
    • Radial nerve palsy associated with fractures of the shaft of the humerus: A systematic review
    • Shao YC, Harwood P, Grotz MR, Limb D, Giannoudis PV (2005) Radial nerve palsy associated with fractures of the shaft of the humerus: A systematic review. J Bone Joint Surg Br 87:1647-1652
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 1647-1652
    • Shao, Y.C.1    Harwood, P.2    Grotz, M.R.3    Limb, D.4    Giannoudis, P.V.5
  • 17
    • 0142199888 scopus 로고    scopus 로고
    • General principles for the clinical use of the LCP
    • Wagner M, (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):B31-42
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Wagner, M.1
  • 18
    • 10044228433 scopus 로고    scopus 로고
    • Helical plate fixation for treatment of comminuted fractures of the proximal and middle one-third of the humerus
    • Yang KH (2005) Helical plate fixation for treatment of comminuted fractures of the proximal and middle one-third of the humerus. Injury 36:75-80
    • (2005) Injury , vol.36 , pp. 75-80
    • Yang, K.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.