메뉴 건너뛰기




Volumn 181, Issue 3, 2009, Pages 230-236

Intraindividual assessment of the thoracic aorta using contrast and non-contrast-enhanced MR angiography

Author keywords

Aorta; Imaging sequences; MR angiography

Indexed keywords

GADOBENATE DIMEGLUMINE; CONTRAST MEDIUM; DIAGNOSTIC AGENT; DRUG DERIVATIVE; GADOBENIC ACID; MEGLUMINE; ORGANOMETALLIC COMPOUND;

EID: 61549112457     PISSN: 14389029     EISSN: 14389010     Source Type: Journal    
DOI: 10.1055/s-0028-1109039     Document Type: Article
Times cited : (13)

References (29)
  • 1
    • 34948904884 scopus 로고    scopus 로고
    • Three-dimensional contrast-enhanced MR angiography of aortic dissection: A pictorial essay
    • Liu Q, Lu JP, Wang F et al. Three-dimensional contrast-enhanced MR angiography of aortic dissection: a pictorial essay. Radiographics 2007; 27: 1311-1321
    • (2007) Radiographics , vol.27 , pp. 1311-1321
    • Liu, Q.1    Lu, J.P.2    Wang, F.3
  • 4
    • 34447617519 scopus 로고    scopus 로고
    • Nephrogene systemische fibrose nach anwendung gadoliniumhaltiger kontrastmittel - Ein statuspapier zum aktuellen stand des wissens
    • DOI 10.1055/s-2007-963166
    • Heinrich M, Uder M. Nephrogene systemische Fibrose nach Anwendung gadoliniumhaltiger Kontrastmittel - ein Statuspapier zum aktuellen Stand des Wissens. Fortschr Rontgenstr 2007; 179: 613-617 (Pubitemid 47091685)
    • (2007) RoFo Fortschritte Auf Dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren , vol.179 , Issue.6 , pp. 613-617
    • Heinrich, M.1    Uder, M.2
  • 5
    • 17444414187 scopus 로고    scopus 로고
    • Vascular diseases of the thorax: Evaluation with multidetector CT
    • DOI 10.1016/j.rcl.2005.02.010
    • Chiles C, Carr JJ. Vascular diseases of the thorax: evaluation with multidetector CT. Radiol Clin North Am 2005; 43: 543-569, viii (Pubitemid 40545050)
    • (2005) Radiologic Clinics of North America , vol.43 , Issue.3 , pp. 543-569
    • Chiles, C.1    Carr, J.J.2
  • 6
    • 33846503873 scopus 로고    scopus 로고
    • Quantitative analysis of ECG-gated high-resolution contrast-enhanced MR angiography of the thoracic aorta
    • DOI 10.2214/AJR.05.1467
    • Groves EM, Bireley W, Dill K et al. Quantitative analysis of ECG-gated high-resolution contrast-enhanced MR angiography of the thoracic aorta. Am J Roentgenol 2007; 188: 522-528 (Pubitemid 46167756)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.2 , pp. 522-528
    • Groves, E.M.1    Bireley, W.2    Dill, K.3    Carroll, T.J.4    Carr, J.C.5
  • 7
    • 30444455906 scopus 로고    scopus 로고
    • Beschleunigung der kardiovaskulären MRT mittels paralleler bildgebung: Grundlagen, praktische aspekte, klinische anwendungen und perspektiven
    • DOI 10.1055/s-2005-858686
    • Niendorf T, Sodickson D. Beschleunigung der kardiovaskulären MRT mittels paralleler Bildgebung: Grundlagen, praktische Aspekte, klinische Anwendungen und Perspektiven. Fortschr Röntgenstr 2006; 178: 15-30 (Pubitemid 43074728)
    • (2006) RoFo Fortschritte Auf Dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren , vol.178 , Issue.1 , pp. 15-30
    • Niendorf, T.1    Sodickson, D.2
  • 8
    • 34548062833 scopus 로고    scopus 로고
    • Comparison of different MRI techniques for the assessment of thoracic aortic pathology: 3D contrast enhanced MR angiography, turbo spin echo and balanced steady state free precession
    • DOI 10.1007/s10554-006-9204-6
    • Gebker R, Gomaa O, Schnackenburg B et al. Comparison of different MRI techniques for the assessment of thoracic aortic pathology: 3D contrast enhanced MR angiography, turbo spin echo and balanced steady state free precession. Int J Cardiovasc Imaging 2007; 23: 747-756 (Pubitemid 350055698)
    • (2007) International Journal of Cardiovascular Imaging , vol.23 , Issue.6 , pp. 747-756
    • Gebker, R.1    Gomaa, O.2    Schnackenburg, B.3    Rebakowski, J.4    Fleck, E.5    Nagel, E.6
  • 10
    • 21244487801 scopus 로고    scopus 로고
    • Three-dimensional, isotropic MRI: A unified approach to quantification and visualization in congenital heart disease
    • DOI 10.1007/s10554-004-4018-x
    • Sorensen TS, Beerbaum P, Korperich H et al. Three-dimensional, isotropic MRI: a unified approach to quantification and visualization in congenital heart disease. Int J Cardiovasc Imaging 2005; 21: 283-292 (Pubitemid 40895335)
    • (2005) International Journal of Cardiovascular Imaging , vol.21 , Issue.2-3 , pp. 283-292
    • Sorensen, T.S.1    Beerbaum, P.2    Korperich, H.3    Pedersen, E.M.4
  • 12
    • 43149092688 scopus 로고    scopus 로고
    • Assessment of thoracic aortic dimensions in an experimental setting: Comparison of different unenhanced magnetic resonance angiography techniques with electrocardiogram-gated computed tomography angiography for possible application in the pediatric population
    • DOI 10.1097/RLI.0b013e31815f8870, PII 0000442420080300000004
    • Ley-Zaporozhan J, Kreitner KF, Unterhinninghofen R et al. Assessment of Thoracic Aortic Dimensions in an Experimental Setting: Comparison of Different Unenhanced Magnetic Resonance Angiography Techniques With Electrocardiogram- Gated Computed Tomography Angiography for Possible Application in the Pediatric Population. Invest Radiol 2008; 43: 179-186 (Pubitemid 351643144)
    • (2008) Investigative Radiology , vol.43 , Issue.3 , pp. 179-186
    • Ley-Zaporozhan, J.1    Kreitner, K.-F.2    Unterhinninghofen, R.3    Helm, E.4    Puderbach, M.5    Schenk, J.-P.6    Deshpande, V.7    Krummenauer, F.8    Szabo, G.9    Kauczor, H.-U.10    Ley, S.11
  • 13
    • 40449112921 scopus 로고    scopus 로고
    • Non-contrast-enhanced MR angiography of the thoracic aorta using cardiac and navigator-gated magnetization-prepared three-dimensional steady-state free precession
    • DOI 10.1002/jmri.21256
    • Amano Y, Takahama K, Kumita S. Non-contrast-enhanced MR angiography of the thoracic aorta using cardiac and navigator-gated magnetization-prepared three-dimensional steady-state free precession. J Magn Reson Imaging 2008; 27: 504-509 (Pubitemid 351354733)
    • (2008) Journal of Magnetic Resonance Imaging , vol.27 , Issue.3 , pp. 504-509
    • Amano, Y.1    Takahama, K.2    Kumita, S.3
  • 14
    • 44449129863 scopus 로고    scopus 로고
    • Non-Contrast 3D SSFP MR Angiography of the Whole Chest Using Non-Selective RF Excitation over a Large Field of View: Comparison with Single-Phase 3D Contrast-Enhanced MRA
    • Krishnam MS, Tomasian A, Deshpande V et al. Non-Contrast 3D SSFP MR Angiography of the Whole Chest Using Non-Selective RF Excitation over a Large Field of View: Comparison with Single-Phase 3D Contrast-Enhanced MRA. Invest Radiol 2008; 43: 411-420
    • (2008) Invest Radiol , vol.43 , pp. 411-420
    • Krishnam, M.S.1    Tomasian, A.2    Deshpande, V.3
  • 16
    • 33645744208 scopus 로고    scopus 로고
    • The comparison of clinical imaging devices with respect to parallel readings in both devices
    • Krummenauer F. The comparison of clinical imaging devices with respect to parallel readings in both devices. Eur J Med Res 2006; 11: 119-122
    • (2006) Eur J Med Res , vol.11 , pp. 119-122
    • Krummenauer, F.1
  • 19
    • 40849130966 scopus 로고    scopus 로고
    • Nephrogenic Systemic Fibrosis: A Sufficient Reason to Avoid Gadolinium-Based Contrast in All Patients with Renal Impairment?
    • Willicombe M, Cunningham J. Nephrogenic Systemic Fibrosis: A Sufficient Reason to Avoid Gadolinium-Based Contrast in All Patients with Renal Impairment? Semin Dial 2008; 21: 140-141
    • (2008) Semin Dial , vol.21 , pp. 140-141
    • Willicombe, M.1    Cunningham, J.2
  • 20
    • 47249139148 scopus 로고    scopus 로고
    • Nonenhanced MR angiography
    • Miyazaki M, Lee VS. Nonenhanced MR angiography. Radiology 2008; 248: 20-43
    • (2008) Radiology , vol.248 , pp. 20-43
    • Miyazaki, M.1    Lee, V.S.2
  • 23
    • 35148879767 scopus 로고    scopus 로고
    • Steady-state free precession MRA of the renal arteries: Breath-hold and navigator-gated techniques vs. CE-MRA
    • Maki JH,Wilson GJ, Eubank WB et al. Steady-state free precession MRA of the renal arteries: Breath-hold and navigator-gated techniques vs. CE-MRA. J Magn Reson Imaging 2007; 26: 966-973
    • (2007) J Magn Reson Imaging , vol.26 , pp. 966-973
    • Maki, J.H.1    Wilson, G.J.2    Eubank, W.B.3
  • 25
    • 4143074672 scopus 로고    scopus 로고
    • Is postcontrast trueFISP imaging advantageous?
    • Jung B, Krombach GA, Gunther RW et al. Is postcontrast trueFISP imaging advantageous? Invest Radiol 2004; 39: 517-523
    • (2004) Invest Radiol , vol.39 , pp. 517-523
    • Jung, B.1    Krombach, G.A.2    Gunther, R.W.3
  • 27
    • 34248675200 scopus 로고    scopus 로고
    • Diagnostische Wertigkeit der kontrastverstärkten Magnetresonanzangiografie der Beckenstrombahn mit dem intravaskulären Kontrastmittel Vasovist®: Erste klinische Erfahrungen im Vergleich zur i. a. DSA
    • Vogt FM, Herborn CU, Parsons EC et al. Diagnostische Wertigkeit der kontrastverstärkten Magnetresonanzangiografie der Beckenstrombahn mit dem intravaskulären Kontrastmittel Vasovist®: Erste klinische Erfahrungen im Vergleich zur i. a. DSA. Fortschr Röntgenstr 2007; 179: 412-420
    • (2007) Fortschr Röntgenstr , vol.179 , pp. 412-420
    • Vogt, F.M.1    Herborn, C.U.2    Parsons, E.C.3
  • 28
    • 12144285912 scopus 로고    scopus 로고
    • High-spatial-resolution 3D balanced turbo field-echo technique for MR angiography of the renal arteries: Initial experience
    • Coenegrachts KL, Hoogeveen RM, Vaninbroukx JA et al. High-spatial- resolution 3D balanced turbo field-echo technique for MR angiography of the renal arteries: initial experience. Radiology 2004; 231: 237-242
    • (2004) Radiology , vol.231 , pp. 237-242
    • Coenegrachts, K.L.1    Hoogeveen, R.M.2    Vaninbroukx, J.A.3
  • 29
    • 45849103511 scopus 로고    scopus 로고
    • Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics
    • Dietrich O, Raya JG, Reeder SB et al. Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics. Magn Reson Imaging 2008; 26: 754-762
    • (2008) Magn Reson Imaging , vol.26 , pp. 754-762
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.