메뉴 건너뛰기




Volumn 231, Issue 1, 2004, Pages 237-242

High-Spatial-Resolution 3D Balanced Turbo Field-Echo Technique for MR Angiography of the Renal Arteries: Initial Experience

Author keywords

Magnetic resonance (MR), three dimensional; Magnetic resonance (MR), vascular studies; Renal arteries, stenosis or obstruction

Indexed keywords

IOBITRIDOL; XENETIX 300;

EID: 12144285912     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2311030044     Document Type: Article
Times cited : (65)

References (16)
  • 1
    • 0032967860 scopus 로고    scopus 로고
    • Renal arteries: Optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold
    • Schoenberg SO, Bock M, Knopp MV, et al. Renal arteries: optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold. Radiology 1999; 211:667-679.
    • (1999) Radiology , vol.211 , pp. 667-679
    • Schoenberg, S.O.1    Bock, M.2    Knopp, M.V.3
  • 2
    • 0035049167 scopus 로고    scopus 로고
    • Assessment of gadolinium-enhanced time-resolved three-dimensional MR angiography for evaluating renal artery stenosis
    • Masunaga H, Takehara Y, Isoda H, et al. Assessment of gadolinium-enhanced time-resolved three-dimensional MR angiography for evaluating renal artery stenosis. AJR Am J Roentgenol 2001; 176:1213-1219.
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 1213-1219
    • Masunaga, H.1    Takehara, Y.2    Isoda, H.3
  • 3
    • 0343986506 scopus 로고    scopus 로고
    • Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: Time-resolved imaging versus single-phase imaging
    • Van Hoe L, De Jaegere T, Bosmans H, et al. Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: time-resolved imaging versus single-phase imaging. Radiology 2000; 214:149-156.
    • (2000) Radiology , vol.214 , pp. 149-156
    • Van Hoe, L.1    De Jaegere, T.2    Bosmans, H.3
  • 5
    • 0030742751 scopus 로고    scopus 로고
    • Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography
    • Hany TF, Debatin JF, Leung DA, Pfammatter T. Evaluation of the aortoiliac and renal arteries: comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography. Radiology 1997; 204:357-362.
    • (1997) Radiology , vol.204 , pp. 357-362
    • Hany, T.F.1    Debatin, J.F.2    Leung, D.A.3    Pfammatter, T.4
  • 6
    • 0031726189 scopus 로고    scopus 로고
    • Combined morphologic and functional assessment of renal artery stenosis using gadolinium enhanced magnetic resonance imaging
    • Schoenberg SO, Knopp MV, Bock M, Prince MR, Allenberg JR. Combined morphologic and functional assessment of renal artery stenosis using gadolinium enhanced magnetic resonance imaging. Nephrol Dial Transplant 1998; 13:2738-2742.
    • (1998) Nephrol Dial Transplant , vol.13 , pp. 2738-2742
    • Schoenberg, S.O.1    Knopp, M.V.2    Bock, M.3    Prince, M.R.4    Allenberg, J.R.5
  • 8
    • 0033227822 scopus 로고    scopus 로고
    • Diagnosis of renal vascular disease with MR angiography
    • Dong Q, Schoenberg SO, Carlos RC, et al. Diagnosis of renal vascular disease with MR angiography. RadioGraphics 1999; 19:1535-1554.
    • (1999) RadioGraphics , vol.19 , pp. 1535-1554
    • Dong, Q.1    Schoenberg, S.O.2    Carlos, R.C.3
  • 9
    • 0028269606 scopus 로고
    • Screening patients for renal artery stenosis: Value of three-dimensional time-of-flight MR angiography
    • Loubeyre P, Revel D, Garcia P, et al. Screening patients for renal artery stenosis: value of three-dimensional time-of-flight MR angiography. AJR Am J Roentgenol 1994; 162:847-852.
    • (1994) AJR Am J Roentgenol , vol.162 , pp. 847-852
    • Loubeyre, P.1    Revel, D.2    Garcia, P.3
  • 10
    • 0031087783 scopus 로고    scopus 로고
    • Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis
    • Duda SH, Schick F, Teufl F, et al. Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis. Acta Radiol 1997; 38:287-291.
    • (1997) Acta Radiol , vol.38 , pp. 287-291
    • Duda, S.H.1    Schick, F.2    Teufl, F.3
  • 12
    • 0035009703 scopus 로고    scopus 로고
    • Magnetization preparation during the steady state: Fat-saturated 3D TrueFISP
    • Scheffler K, Heid O, Hennig J. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP. Magn Reson Med 2001; 45:1075-1080.
    • (2001) Magn Reson Med , vol.45 , pp. 1075-1080
    • Scheffler, K.1    Heid, O.2    Hennig, J.3
  • 15
    • 0026486818 scopus 로고
    • Time-of-flight magnetic resonance angiography of the aorta and renal arteries
    • Lewin JS. Time-of-flight magnetic resonance angiography of the aorta and renal arteries. Invest Radiol 1992; 27(suppl):S84-S89.
    • (1992) Invest Radiol , vol.27 , Issue.SUPPL.
    • Lewin, J.S.1
  • 16
    • 0029837918 scopus 로고    scopus 로고
    • Transplant renal artery stenosis: Evaluation of diagnosis with magnetic resonance angiography compared with color duplex sonography and arteriography
    • Loubeyre P, Cahen R, Grozel F, et al. Transplant renal artery stenosis: evaluation of diagnosis with magnetic resonance angiography compared with color duplex sonography and arteriography. Transplantation 1996; 62: 446-450.
    • (1996) Transplantation , vol.62 , pp. 446-450
    • Loubeyre, P.1    Cahen, R.2    Grozel, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.