-
1
-
-
0036325261
-
New technical developments in multislice CT-part 1: approaching isotropic resolution with sub-millimeter 16-slice scanning
-
Flohr T., Stierstorfer K., Bruder H., et al. New technical developments in multislice CT-part 1: approaching isotropic resolution with sub-millimeter 16-slice scanning. Rofo 174 (2002) 839-845
-
(2002)
Rofo
, vol.174
, pp. 839-845
-
-
Flohr, T.1
Stierstorfer, K.2
Bruder, H.3
-
2
-
-
2542425641
-
Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature
-
Völk M., Hamer O.W., Feuerbach S., et al. Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature. Eur Radiol 14 (2004) 827-834
-
(2004)
Eur Radiol
, vol.14
, pp. 827-834
-
-
Völk, M.1
Hamer, O.W.2
Feuerbach, S.3
-
3
-
-
0035989949
-
A performance comparison of flat-panel imager-based MV and kV cone-beam CT
-
Groh B.A., Siewerdsen J.H., Drake D.G., et al. A performance comparison of flat-panel imager-based MV and kV cone-beam CT. Med Phys 29 (2002) 967-975
-
(2002)
Med Phys
, vol.29
, pp. 967-975
-
-
Groh, B.A.1
Siewerdsen, J.H.2
Drake, D.G.3
-
4
-
-
0038418577
-
Performance of a flat-panel detector in the detection of artificial erosive changes: comparison with conventional screen-film and storage-phosphor radiography
-
Ludwig K., Henschel A., Bernhardt T.M., et al. Performance of a flat-panel detector in the detection of artificial erosive changes: comparison with conventional screen-film and storage-phosphor radiography. Eur Radiol 13 (2003) 1316-1323
-
(2003)
Eur Radiol
, vol.13
, pp. 1316-1323
-
-
Ludwig, K.1
Henschel, A.2
Bernhardt, T.M.3
-
5
-
-
12544249502
-
Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience
-
Nikolaou K., Flohr T., Stierstorfer K., et al. Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience. Eur Radiol 15 (2005) 329-333
-
(2005)
Eur Radiol
, vol.15
, pp. 329-333
-
-
Nikolaou, K.1
Flohr, T.2
Stierstorfer, K.3
-
6
-
-
0036851816
-
Effects of raloxifene on fracture severity in postmenopausal women with osteoporosis: results from the MORE study
-
Siris E., Adachi J.D., Lu Y., et al. Effects of raloxifene on fracture severity in postmenopausal women with osteoporosis: results from the MORE study. Osteoporos Int 13 (2002) 907-913
-
(2002)
Osteoporos Int
, vol.13
, pp. 907-913
-
-
Siris, E.1
Adachi, J.D.2
Lu, Y.3
-
7
-
-
16844387152
-
Bone response to treatment with lower doses of conjugated estrogens with and without medroxyprogesterone acetate in early postmenopausal women
-
Lindsay R., Gallagher J.C., Kleerekoper M., et al. Bone response to treatment with lower doses of conjugated estrogens with and without medroxyprogesterone acetate in early postmenopausal women. Osteoporos Int 16 (2005) 372-379
-
(2005)
Osteoporos Int
, vol.16
, pp. 372-379
-
-
Lindsay, R.1
Gallagher, J.C.2
Kleerekoper, M.3
-
8
-
-
33845357774
-
Severity of vertebral fracture reflects deterioration of bone microarchitecture
-
Genant H.K., Delmas P.D., Chen P., et al. Severity of vertebral fracture reflects deterioration of bone microarchitecture. Osteoporos Int 18 (2007) 69-76
-
(2007)
Osteoporos Int
, vol.18
, pp. 69-76
-
-
Genant, H.K.1
Delmas, P.D.2
Chen, P.3
-
9
-
-
13844293153
-
Raloxifene- and estradiol-mediated effects on uterus, bone and B lymphocytes in mice
-
Erlandsson M.C., Jonsson C.A., Lindberg M.K., et al. Raloxifene- and estradiol-mediated effects on uterus, bone and B lymphocytes in mice. J Endocrinol 175 (2002) 319-327
-
(2002)
J Endocrinol
, vol.175
, pp. 319-327
-
-
Erlandsson, M.C.1
Jonsson, C.A.2
Lindberg, M.K.3
-
10
-
-
0037125379
-
Risks and benefits of estrogen plus progestin in healthy postmenopausal women: principal results from the Women's Health Initiative randomized controlled trial
-
Rossouw J.E., Anderson G.L., Prentice R.L., et al. Risks and benefits of estrogen plus progestin in healthy postmenopausal women: principal results from the Women's Health Initiative randomized controlled trial. JAMA 288 (2002) 321-333
-
(2002)
JAMA
, vol.288
, pp. 321-333
-
-
Rossouw, J.E.1
Anderson, G.L.2
Prentice, R.L.3
-
11
-
-
29644439883
-
Standardized bending and breaking test for the normal and osteoporotic metaphyseal tibias of the rat: effect of estradiol, testosterone, and raloxifene
-
Stürmer E.K., Seidlová-Wuttke D., Sehmisch S., et al. Standardized bending and breaking test for the normal and osteoporotic metaphyseal tibias of the rat: effect of estradiol, testosterone, and raloxifene. J Bone Miner Res 21 (2006) 89-96
-
(2006)
J Bone Miner Res
, vol.21
, pp. 89-96
-
-
Stürmer, E.K.1
Seidlová-Wuttke, D.2
Sehmisch, S.3
-
12
-
-
0021882525
-
Quantitative determination of the effect of induced alternating currents on the integration of autologous spongiosa transplants
-
Stürmer K.M., and Schmit-Neuerburg K.P. Quantitative determination of the effect of induced alternating currents on the integration of autologous spongiosa transplants. Unfallchirurgie 11 (1985) 168-173
-
(1985)
Unfallchirurgie
, vol.11
, pp. 168-173
-
-
Stürmer, K.M.1
Schmit-Neuerburg, K.P.2
-
13
-
-
29144534207
-
Role of osteoporosis in trauma diagnostics
-
Bitterling H., Vogel T., Dobler T., et al. Role of osteoporosis in trauma diagnostics. Rofo 177 (2005) 1663-1669
-
(2005)
Rofo
, vol.177
, pp. 1663-1669
-
-
Bitterling, H.1
Vogel, T.2
Dobler, T.3
-
15
-
-
0032928869
-
Quantitative computer tomography
-
Prevrhal S., and Genant H.K. Quantitative computer tomography. Radiologe 39 (1999) 194-202
-
(1999)
Radiologe
, vol.39
, pp. 194-202
-
-
Prevrhal, S.1
Genant, H.K.2
-
16
-
-
22044443714
-
Clinical practice. Screening for osteoporosis
-
Raisz L.G. Clinical practice. Screening for osteoporosis. N Engl J Med 353 (2005) 164-171
-
(2005)
N Engl J Med
, vol.353
, pp. 164-171
-
-
Raisz, L.G.1
-
17
-
-
0032898905
-
Micro-CT. Technology and application for assessing bone structure
-
Engelke K., Karolczak M., Lutz A., et al. Micro-CT. Technology and application for assessing bone structure. Radiologe 39 (1999) 203-212
-
(1999)
Radiologe
, vol.39
, pp. 203-212
-
-
Engelke, K.1
Karolczak, M.2
Lutz, A.3
-
18
-
-
14844323000
-
The bone quality framework: determinants of bone strength and their interrelationships, and implications for osteoporosis management
-
Felsenberg D., and Boonen S. The bone quality framework: determinants of bone strength and their interrelationships, and implications for osteoporosis management. Clin Ther 27 (2005) 1-11
-
(2005)
Clin Ther
, vol.27
, pp. 1-11
-
-
Felsenberg, D.1
Boonen, S.2
-
19
-
-
0345015502
-
Excised bone structures in mice: imaging at three-dimensional synchrotron radiation micro CT
-
Martin-Badosa E., Amblard D., Nuzzo S., et al. Excised bone structures in mice: imaging at three-dimensional synchrotron radiation micro CT. Radiology 229 (2003) 921-928
-
(2003)
Radiology
, vol.229
, pp. 921-928
-
-
Martin-Badosa, E.1
Amblard, D.2
Nuzzo, S.3
-
20
-
-
23044459875
-
Flat-panel computed tomography: a new method for visualizing fine bone detail in living mice
-
Obert M., Ahlemeyer B., Baumgart-Vogt E., et al. Flat-panel computed tomography: a new method for visualizing fine bone detail in living mice. J Comput Assist Tomogr 29 (2005) 560-565
-
(2005)
J Comput Assist Tomogr
, vol.29
, pp. 560-565
-
-
Obert, M.1
Ahlemeyer, B.2
Baumgart-Vogt, E.3
-
21
-
-
0030053035
-
Accuracy and the influence of marrow fat on quantitative CT and dual-energy x-ray absorptiometry measurements of the femoral neck in vitro
-
Kuiper J.W., van Kuijk C., Grashuis J.L., et al. Accuracy and the influence of marrow fat on quantitative CT and dual-energy x-ray absorptiometry measurements of the femoral neck in vitro. Osteoporosis Int 6 (1996) 25-30
-
(1996)
Osteoporosis Int
, vol.6
, pp. 25-30
-
-
Kuiper, J.W.1
van Kuijk, C.2
Grashuis, J.L.3
-
22
-
-
0024439165
-
Impact of marrow fat in accuracy of quantitative CT
-
Glüer C.C., and Genant H.K. Impact of marrow fat in accuracy of quantitative CT. J Comput Assist Tomogr 13 (1989) 1023-1035
-
(1989)
J Comput Assist Tomogr
, vol.13
, pp. 1023-1035
-
-
Glüer, C.C.1
Genant, H.K.2
-
23
-
-
16544384782
-
Experimental flat-panel high-spatial-resolution volume CT of the temporal bone
-
Gupta R., Bartling S.H., Basu S.K., et al. Experimental flat-panel high-spatial-resolution volume CT of the temporal bone. AJNR Am J Neuroradiol 25 (2004) 1417-1424
-
(2004)
AJNR Am J Neuroradiol
, vol.25
, pp. 1417-1424
-
-
Gupta, R.1
Bartling, S.H.2
Basu, S.K.3
-
24
-
-
31044442530
-
Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom
-
Taschereau R., Chow P.L., and Chatziioannou A.F. Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom. Med Phys 33 (2006) 216-224
-
(2006)
Med Phys
, vol.33
, pp. 216-224
-
-
Taschereau, R.1
Chow, P.L.2
Chatziioannou, A.F.3
-
25
-
-
34948833684
-
Flat-panel detector-based volume computed tomography: a novel 3D imaging technique to monitor osteolytic bone lesions in a mouse tumor metastasis model
-
Missbach-Guentner J., Dullin C., Zientkowska M., et al. Flat-panel detector-based volume computed tomography: a novel 3D imaging technique to monitor osteolytic bone lesions in a mouse tumor metastasis model. Neoplasia 9 (2007) 755-765
-
(2007)
Neoplasia
, vol.9
, pp. 755-765
-
-
Missbach-Guentner, J.1
Dullin, C.2
Zientkowska, M.3
-
26
-
-
45849090257
-
Morphological changes of mammary carcinomas in mice over time as monitored by flat-panel detector volume computed tomography
-
Missbach-Guentner J., Dullin C., Kimmina S., et al. Morphological changes of mammary carcinomas in mice over time as monitored by flat-panel detector volume computed tomography. Neoplasia 10 (2008) 663-673
-
(2008)
Neoplasia
, vol.10
, pp. 663-673
-
-
Missbach-Guentner, J.1
Dullin, C.2
Kimmina, S.3
-
27
-
-
33144456935
-
Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging
-
Greschus S., Kiessling F., Lichy M.P., et al. Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging. Neoplasia 7 (2005) 730-740
-
(2005)
Neoplasia
, vol.7
, pp. 730-740
-
-
Greschus, S.1
Kiessling, F.2
Lichy, M.P.3
-
28
-
-
7044270611
-
Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis
-
Kiessling F., Greschus S., Lichy M.P., et al. Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis. Nat Med 10 (2005) 1133-1138
-
(2005)
Nat Med
, vol.10
, pp. 1133-1138
-
-
Kiessling, F.1
Greschus, S.2
Lichy, M.P.3
-
29
-
-
54949157336
-
Musculoskeletal applications of flat-panel volume CT
-
Reichardt B., Sarwar A., Bartling S.H., et al. Musculoskeletal applications of flat-panel volume CT. Skeletal Radiol 37 (2008) 1069-1076
-
(2008)
Skeletal Radiol
, vol.37
, pp. 1069-1076
-
-
Reichardt, B.1
Sarwar, A.2
Bartling, S.H.3
|