메뉴 건너뛰기




Volumn 15, Issue 2, 2005, Pages 329-333

Flat panel computed tomography of human ex vivo heart and bone specimens: Initial experience

Author keywords

Computed tomography; Flat panel detector

Indexed keywords

ARTICLE; BONE TISSUE; CLINICAL EXAMINATION; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; CONTROLLED STUDY; CORONARY ARTERY; EX VIVO STUDY; EXPERIENCE; EXPLANT; FOOT; HEART; HUMAN; HUMAN TISSUE; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; IN VIVO STUDY; PRIORITY JOURNAL; TRABECULAR BONE; VELOCITY;

EID: 12544249502     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-004-2537-4     Document Type: Article
Times cited : (35)

References (22)
  • 1
    • 0036325261 scopus 로고    scopus 로고
    • New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning
    • 10.1055/s-2002-32692
    • Flohr T, Stierstorfer K, Bruder H, Simon J, Schaller S (2002) New technical developments in multislice CT - part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174(7):839-845 10.1055/s-2002-32692
    • (2002) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.174 , Issue.7 , pp. 839-845
    • Flohr, T.1    Stierstorfer, K.2    Bruder, H.3    Simon, J.4    Schaller, S.5
  • 2
    • 0034257868 scopus 로고    scopus 로고
    • Single-slice rebinning reconstruction in spiral cone-beam computed tomography
    • 10.1109/42.887836
    • Bruder H, Kachelriess M, Schaller S, Stierstorfer K, Flohr T (2000) Single-slice rebinning reconstruction in spiral cone-beam computed tomography. IEEE Trans Med Imaging 19(9):873-887 10.1109/42.887836
    • (2000) IEEE Trans. Med. Imaging , vol.19 , Issue.9 , pp. 873-887
    • Bruder, H.1    Kachelriess, M.2    Schaller, S.3    Stierstorfer, K.4    Flohr, T.5
  • 3
    • 0038418577 scopus 로고    scopus 로고
    • Performance of a flat-panel detector in the detection of artificial erosive changes: Comparison with conventional screen-film and storage-phosphor radiography
    • 12764648
    • Ludwig K, Henschel A, Bernhardt TM, Lenzen H, Wormanns D, Diederich S et al (2003) Performance of a flat-panel detector in the detection of artificial erosive changes: Comparison with conventional screen-film and storage-phosphor radiography. Eur Radiol 13(6):1316-1323 12764648
    • (2003) Eur. Radiol. , vol.13 , Issue.6 , pp. 1316-1323
    • Ludwig, K.1    Henschel, A.2    Bernhardt, T.M.3    Lenzen, H.4    Wormanns, D.5    Diederich, S.6
  • 4
    • 0036781512 scopus 로고    scopus 로고
    • Digital radiography with large-area flat-panel detectors
    • 1:STN:280:DC%2BD38vosVGisw%3D%3D
    • Kotter E, Langer M (2002) Digital radiography with large-area flat-panel detectors. Eur Radiol 12(10):2562-2570 1:STN:280:DC%2BD38vosVGisw%3D%3D
    • (2002) Eur. Radiol. , vol.12 , Issue.10 , pp. 2562-2570
    • Kotter, E.1    Langer, M.2
  • 5
    • 0038457603 scopus 로고    scopus 로고
    • The use of flat-panel detectors for CT imaging
    • 10.1007/s00117-003-0897-4
    • Kalender WA (2003) The use of flat-panel detectors for CT imaging. Radiologe 43(5):379-387 10.1007/s00117-003-0897-4
    • (2003) Radiologe , vol.43 , Issue.5 , pp. 379-387
    • Kalender, W.A.1
  • 6
    • 2542425641 scopus 로고    scopus 로고
    • Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: Technical background, basic image quality parameters, and review of the literature
    • 10.1007/s00330-004-2243-2
    • Volk M, Hamer OW, Feuerbach S, Strotzer M (2004) Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: Technical background, basic image quality parameters, and review of the literature. Eur Radiol 14(5):827-834 10.1007/s00330-004-2243-2
    • (2004) Eur. Radiol. , vol.14 , Issue.5 , pp. 827-834
    • Volk, M.1    Hamer, O.W.2    Feuerbach, S.3    Strotzer, M.4
  • 7
    • 0035989949 scopus 로고    scopus 로고
    • A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    • 10.1118/1.1477234
    • Groh BA, Siewerdsen JH, Drake DG, Wong JW, Jaffray DA (2002) A performance comparison of flat-panel imager-based MV and kV cone-beam CT. Med Phys 29(6):967-975 10.1118/1.1477234
    • (2002) Med. Phys. , vol.29 , Issue.6 , pp. 967-975
    • Groh, B.A.1    Siewerdsen, J.H.2    Drake, D.G.3    Wong, J.W.4    Jaffray, D.A.5
  • 8
    • 0034086714 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • 10.1118/1.599009
    • Jaffray DA, Siewerdsen JH (2000) Cone-beam computed tomography with a flat-panel imager: Initial performance characterization. Med Phys 27(6):1311-1323 10.1118/1.599009
    • (2000) Med. Phys. , vol.27 , Issue.6 , pp. 1311-1323
    • Jaffray, D.A.1    Siewerdsen, J.H.2
  • 9
    • 0037418182 scopus 로고    scopus 로고
    • Image in cardiovascular medicine. Coronary artery imaging with flat-panel computed tomography
    • 10.1161/01.CIR.0000056031.70883.C5
    • Knollmann F, Pfoh A (2003) Image in cardiovascular medicine. Coronary artery imaging with flat-panel computed tomography. Circulation 107(8):1209 10.1161/01.CIR.0000056031.70883.C5
    • (2003) Circulation , vol.107 , Issue.8 , pp. 1209
    • Knollmann, F.1    Pfoh, A.2
  • 10
    • 0026552271 scopus 로고
    • A cone-beam tomography algorithm for orthogonal circle-and-line orbit
    • 10.1088/0031-9155/37/3/005
    • Zeng GL, Gullberg GT (1992) A cone-beam tomography algorithm for orthogonal circle-and-line orbit. Phys Med Biol 37(3):563-577 10.1088/0031-9155/37/3/005
    • (1992) Phys. Med. Biol. , vol.37 , Issue.3 , pp. 563-577
    • Zeng, G.L.1    Gullberg, G.T.2
  • 11
    • 0036373605 scopus 로고    scopus 로고
    • New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging
    • 10.1055/s-2002-32930
    • Flohr T, Bruder H, Stierstorfer K, Simon J, Schaller S, Ohnesorge B (2002) New technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174(8):1022-1027 10.1055/s-2002-32930
    • (2002) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.174 , Issue.8 , pp. 1022-1027
    • Flohr, T.1    Bruder, H.2    Stierstorfer, K.3    Simon, J.4    Schaller, S.5    Ohnesorge, B.6
  • 13
    • 0346848771 scopus 로고    scopus 로고
    • Complementary results of computed tomography and magnetic resonance imaging of the heart and coronary arteries: A review and future outlook
    • 14719573
    • Nikolaou K, Poon M, Sirol M, Becker CR, Fayad ZA (2003) Complementary results of computed tomography and magnetic resonance imaging of the heart and coronary arteries: A review and future outlook. Cardiol Clin 21(4):639-655 14719573
    • (2003) Cardiol. Clin. , vol.21 , Issue.4 , pp. 639-655
    • Nikolaou, K.1    Poon, M.2    Sirol, M.3    Becker, C.R.4    Fayad, Z.A.5
  • 14
    • 2942748335 scopus 로고    scopus 로고
    • Coronary artery disease: New insights and their implications for radiology
    • 10.1007/s00330-003-2175-2
    • Dewey M, Borges AC, Kivelitz D, Taupitz M, Wagner S, Baumann G et al (2004) Coronary artery disease: New insights and their implications for radiology. Eur Radiol 14(6):1048-1054 10.1007/s00330-003-2175-2
    • (2004) Eur. Radiol. , vol.14 , Issue.6 , pp. 1048-1054
    • Dewey, M.1    Borges, A.C.2    Kivelitz, D.3    Taupitz, M.4    Wagner, S.5    Baumann, G.6
  • 15
    • 0037044418 scopus 로고    scopus 로고
    • Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: Current and potential future concepts
    • 10.1161/01.CIR.0000034392.34211.FC
    • Fayad ZA, Fuster V, Nikolaou K, Becker C (2002) Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: Current and potential future concepts. Circulation 106(15):2026-2034 10.1161/01.CIR.0000034392.34211.FC
    • (2002) Circulation , vol.106 , Issue.15 , pp. 2026-2034
    • Fayad, Z.A.1    Fuster, V.2    Nikolaou, K.3    Becker, C.4
  • 16
    • 0032422150 scopus 로고    scopus 로고
    • 3D angiography. Clinical interest. First applications in interventional neuroradiology
    • 1:STN:280:DyaK1M7lslyhug%3D%3D
    • Anxionnat R, Bracard S, Macho J, Da Costa E, Vaillant R, Launay L et al (1998) 3D angiography. Clinical interest. First applications in interventional neuroradiology. J Neuroradiol 25(4):251-262 1:STN:280:DyaK1M7lslyhug%3D%3D
    • (1998) J. Neuroradiol. , vol.25 , Issue.4 , pp. 251-262
    • Anxionnat, R.1    Bracard, S.2    Macho, J.3    Da Costa, E.4    Vaillant, R.5    Launay, L.6
  • 17
    • 0035191083 scopus 로고    scopus 로고
    • Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: Initial results
    • 11719688
    • El Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T et al (2001) Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: Initial results. Radiology 221(3):843-849
    • (2001) Radiology , vol.221 , Issue.3 , pp. 843-849
    • El Sheik, M.1    Heverhagen, J.T.2    Alfke, H.3    Froelich, J.J.4    Hornegger, J.5    Brunner, T.6
  • 18
    • 0036082380 scopus 로고    scopus 로고
    • Three-dimensional CT with a modified C-arm image intensifier: Feasibility
    • 12091697
    • Linsenmaier U, Rock C, Euler E, Wirth S, Brandl R, Kotsianos D et al (2002) Three-dimensional CT with a modified C-arm image intensifier: feasibility. Radiology 224(1):286-292 12091697
    • (2002) Radiology , vol.224 , Issue.1 , pp. 286-292
    • Linsenmaier, U.1    Rock, C.2    Euler, E.3    Wirth, S.4    Brandl, R.5    Kotsianos, D.6
  • 19
    • 0034257874 scopus 로고    scopus 로고
    • Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation
    • 10.1109/42.887842
    • Ning R, Chen B, Yu R, Conover D, Tang X, Ning Y (2000) Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation. IEEE Trans Med Imaging 19(9):949-963 10.1109/42.887842
    • (2000) IEEE Trans. Med. Imaging , vol.19 , Issue.9 , pp. 949-963
    • Ning, R.1    Chen, B.2    Yu, R.3    Conover, D.4    Tang, X.5    Ning, Y.6
  • 20
    • 0038710363 scopus 로고    scopus 로고
    • Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: Preliminary phantom study
    • 10.1118/1.1582470
    • Ning R, Tang X, Conover D, Yu R (2003) Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: Preliminary phantom study. Med Phys 30(7):1694-1705 10.1118/1.1582470
    • (2003) Med. Phys. , vol.30 , Issue.7 , pp. 1694-1705
    • Ning, R.1    Tang, X.2    Conover, D.3    Yu, R.4
  • 21
    • 0038509013 scopus 로고    scopus 로고
    • Flat-panel detectors in X-ray systems
    • 10.1007/s00117-003-0890-y
    • Spahn M, Heer V, Freytag R (2003) Flat-panel detectors in X-ray systems. Radiologe 43(5):340-350 10.1007/s00117-003-0890-y
    • (2003) Radiologe , vol.43 , Issue.5 , pp. 340-350
    • Spahn, M.1    Heer, V.2    Freytag, R.3
  • 22
    • 0842345477 scopus 로고    scopus 로고
    • Low-contrast detectability in volume rendering: A phantom study on multidetector-row spiral CT data
    • 10.1007/s00330-003-2084-4
    • Shin HO, Falck CV, Galanski M (2004) Low-contrast detectability in volume rendering: A phantom study on multidetector-row spiral CT data. Eur Radiol 14(2):341-349 10.1007/s00330-003-2084-4
    • (2004) Eur. Radiol. , vol.14 , Issue.2 , pp. 341-349
    • Shin, H.O.1    Falck, C.V.2    Galanski, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.