메뉴 건너뛰기




Volumn 402, Issue 1-2, 2009, Pages 7-13

Overview on self-monitoring of blood glucose

Author keywords

Diabetes; Glucose; Portable glucose meter; Self monitoring

Indexed keywords

GALACTOSE; GLUCOSE; HEMOGLOBIN A1C; INSULIN; MALTOSE; NONSTEROID ANTIINFLAMMATORY AGENT; ORAL ANTIDIABETIC AGENT; PARACETAMOL; XYLOSE;

EID: 60649089405     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cca.2009.01.002     Document Type: Review
Times cited : (109)

References (85)
  • 1
    • 40249120466 scopus 로고    scopus 로고
    • Standards of medical care in diabetes - 2008
    • American Diabetes Association. Standards of medical care in diabetes - 2008. Diabetes Care 31 Suppl 1 (2008) S12-54
    • (2008) Diabetes Care , vol.31 , Issue.SUPPL. 1
    • American Diabetes Association1
  • 2
    • 0036177713 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks D.B., Bruns D.E., Goldstein D.E., Maclaren N.K., McDonald J.M., and Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 48 (2002) 436-472
    • (2002) Clin Chem , vol.48 , pp. 436-472
    • Sacks, D.B.1    Bruns, D.E.2    Goldstein, D.E.3    Maclaren, N.K.4    McDonald, J.M.5    Parrott, M.6
  • 3
    • 60649096102 scopus 로고    scopus 로고
    • D.B. Sacks, M. Arnold, G.L. Bakris, et al. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Draft version 1107. Available at: http://www.aacc.org/sitecollectiondocuments/nacb/lmpg/diabetes/1107_diabetesupdate_draftguidelines.pdf.
    • D.B. Sacks, M. Arnold, G.L. Bakris, et al. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Draft version 1107. Available at: http://www.aacc.org/sitecollectiondocuments/nacb/lmpg/diabetes/1107_diabetesupdate_draftguidelines.pdf.
  • 4
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of longterm complications in insulin-dependent diabetes mellitus
    • DCCT Research Group. The effect of intensive treatment of diabetes on the development and progression of longterm complications in insulin-dependent diabetes mellitus. N Engl J Med 329 (1993) 977-986
    • (1993) N Engl J Med , vol.329 , pp. 977-986
    • DCCT Research Group1
  • 5
    • 0034939686 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanent Diabetes Registry
    • Karter A.J., Ackerson L.M., Darbinian J.A., et al. Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanent Diabetes Registry. Am J Med 111 (2001) 1-9
    • (2001) Am J Med , vol.111 , pp. 1-9
    • Karter, A.J.1    Ackerson, L.M.2    Darbinian, J.A.3
  • 6
    • 0033542663 scopus 로고    scopus 로고
    • Frequency of blood glucose monitoring in relation to glycemic control: observation study with diabetes database
    • Evans J.M.M., Newton R.W., Ruta D.A., et al. Frequency of blood glucose monitoring in relation to glycemic control: observation study with diabetes database. Br Med J 319 (1999) 83-86
    • (1999) Br Med J , vol.319 , pp. 83-86
    • Evans, J.M.M.1    Newton, R.W.2    Ruta, D.A.3
  • 7
    • 0043171112 scopus 로고    scopus 로고
    • Intensified blood glucose monitoring improves glycemic control in stable, insulin-treated veterans with type 2 diabetes
    • Murata G.H., Shah J.H., Hoffman R.M., et al. Intensified blood glucose monitoring improves glycemic control in stable, insulin-treated veterans with type 2 diabetes. Diabetes Care 26 (2003) 1759-1763
    • (2003) Diabetes Care , vol.26 , pp. 1759-1763
    • Murata, G.H.1    Shah, J.H.2    Hoffman, R.M.3
  • 8
    • 34548627226 scopus 로고    scopus 로고
    • Recommendations and conclusions from a mini-symposium on self-blood glucose monitoring
    • Reynolds R.M., and Webb D.J. Recommendations and conclusions from a mini-symposium on self-blood glucose monitoring. J R Coll Physicians Edinb 36 (2006) 155-158
    • (2006) J R Coll Physicians Edinb , vol.36 , pp. 155-158
    • Reynolds, R.M.1    Webb, D.J.2
  • 9
    • 34047160837 scopus 로고    scopus 로고
    • Consensus statement on self-monitoring in diabetes: Institute of Health Economics, Alberta, Canada
    • Consensus statement on self-monitoring in diabetes: Institute of Health Economics, Alberta, Canada. Int J Technol Assess Health Care 23 (2007) 146-151
    • (2007) Int J Technol Assess Health Care , vol.23 , pp. 146-151
  • 10
    • 4844219794 scopus 로고    scopus 로고
    • Home blood glucose monitoring in type 2 diabetes
    • Reynolds R.M., and Strachan M.W.J. Home blood glucose monitoring in type 2 diabetes. BMJ 326 (2004) 754-755
    • (2004) BMJ , vol.326 , pp. 754-755
    • Reynolds, R.M.1    Strachan, M.W.J.2
  • 11
    • 19944412732 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose in patients with type 2 diabetes who are not using insulin: a systematic review
    • Welschen L.M.C., Bloemendal E., Nijpels G., et al. Self-monitoring of blood glucose in patients with type 2 diabetes who are not using insulin: a systematic review. Diabetes Care 28 (2005) 1510-1517
    • (2005) Diabetes Care , vol.28 , pp. 1510-1517
    • Welschen, L.M.C.1    Bloemendal, E.2    Nijpels, G.3
  • 12
    • 0036074992 scopus 로고    scopus 로고
    • Reduction in self-monitoring of blood glucose in persons with type 2 diabetes results in cost savings and no change in glycemic control
    • Meier J.L., Swislocki L.M., Lopez J.R., Noth R.H., Bartlebaugh P., and Siegel D. Reduction in self-monitoring of blood glucose in persons with type 2 diabetes results in cost savings and no change in glycemic control. Am J Managed Care 8 (2002) 557-565
    • (2002) Am J Managed Care , vol.8 , pp. 557-565
    • Meier, J.L.1    Swislocki, L.M.2    Lopez, J.R.3    Noth, R.H.4    Bartlebaugh, P.5    Siegel, D.6
  • 13
    • 0036834583 scopus 로고    scopus 로고
    • Meal-related structured self-monitoring of blood glucose: effects on diabetes control in non-insulin-treated type 2 diabetic patients
    • Schwedes U., and Siebolds M. Meal-related structured self-monitoring of blood glucose: effects on diabetes control in non-insulin-treated type 2 diabetic patients. Diabetes Care 25 (2002) 1928-1932
    • (2002) Diabetes Care , vol.25 , pp. 1928-1932
    • Schwedes, U.1    Siebolds, M.2
  • 14
    • 16344382163 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose as part of a multi-component therapy among non-insulin requiring type 2 diabetes patients: a meta-analysis (1966-2004)
    • Sarol J.N., Nicodemus N.A., Tan K.M., and Grava M.B. Self-monitoring of blood glucose as part of a multi-component therapy among non-insulin requiring type 2 diabetes patients: a meta-analysis (1966-2004). Curr Med Res Opin 21 (2005) 173-183
    • (2005) Curr Med Res Opin , vol.21 , pp. 173-183
    • Sarol, J.N.1    Nicodemus, N.A.2    Tan, K.M.3    Grava, M.B.4
  • 15
    • 33747597295 scopus 로고    scopus 로고
    • Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24500 patients form 191 centers in Germany and Austria
    • Schütt M., Kern W., Krause U., et al. Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24500 patients form 191 centers in Germany and Austria. Exp Clin Endocrinol Diabetes 114 (2006) 384-388
    • (2006) Exp Clin Endocrinol Diabetes , vol.114 , pp. 384-388
    • Schütt, M.1    Kern, W.2    Krause, U.3
  • 16
    • 33750192669 scopus 로고    scopus 로고
    • Self monitoring in type 2 diabetes: a randomized trial of reimbursement policy
    • Johnson J.A., Majumdar S.R., Bowker S.L., Toth E.L., and Edwards A. Self monitoring in type 2 diabetes: a randomized trial of reimbursement policy. Diabet Med 23 (2006) 1247-1251
    • (2006) Diabet Med , vol.23 , pp. 1247-1251
    • Johnson, J.A.1    Majumdar, S.R.2    Bowker, S.L.3    Toth, E.L.4    Edwards, A.5
  • 17
    • 0034939686 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser permanent diabetes registry
    • Karter A.J., Ackerson L.M., Darbinian J.A., et al. Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser permanent diabetes registry. Am J Med 111 (2001) 1-9
    • (2001) Am J Med , vol.111 , pp. 1-9
    • Karter, A.J.1    Ackerson, L.M.2    Darbinian, J.A.3
  • 18
    • 0036834583 scopus 로고    scopus 로고
    • Meal-related structured self monitoring of blood glucose: effect on diabetes control in non-insulin-treated type 2 diabetic patients
    • Schwedes U., Siebolds M., and Mertes G. Meal-related structured self monitoring of blood glucose: effect on diabetes control in non-insulin-treated type 2 diabetic patients. Diabetes Care 25 (2002) 1928-1932
    • (2002) Diabetes Care , vol.25 , pp. 1928-1932
    • Schwedes, U.1    Siebolds, M.2    Mertes, G.3
  • 19
    • 0043171112 scopus 로고    scopus 로고
    • Intensified blood glucose monitoring improves glycemiccontrol in stable, insulin-treated veterans with type 2 diabetes: the Diabetes Outcomes in Veterans Study (DOVES)
    • Murata G.H., Shah J.H., Hoffman R.M., et al. Intensified blood glucose monitoring improves glycemiccontrol in stable, insulin-treated veterans with type 2 diabetes: the Diabetes Outcomes in Veterans Study (DOVES). Diabetes Care 26 (2003) 1759-1763
    • (2003) Diabetes Care , vol.26 , pp. 1759-1763
    • Murata, G.H.1    Shah, J.H.2    Hoffman, R.M.3
  • 20
    • 9144269668 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose significantly improves metabolic control in patients with type 2 diabetes mellitus: the Auto-Surveillance Intervention Active (ASIA) study
    • Guerci B., Drouin P., Grangé V., et al. Self-monitoring of blood glucose significantly improves metabolic control in patients with type 2 diabetes mellitus: the Auto-Surveillance Intervention Active (ASIA) study. Diabetes Metab 29 (2003) 587-594
    • (2003) Diabetes Metab , vol.29 , pp. 587-594
    • Guerci, B.1    Drouin, P.2    Grangé, V.3
  • 21
    • 16244383852 scopus 로고    scopus 로고
    • The effect of self monitoring of blood glucose concentrations on glycated hemoglobin levels in diabetic patients not taking insulin: a blinded, randomized trial
    • Davidson M.B., Castellanos M., Kain D., et al. The effect of self monitoring of blood glucose concentrations on glycated hemoglobin levels in diabetic patients not taking insulin: a blinded, randomized trial. Am J Med 118 (2005) 422-425
    • (2005) Am J Med , vol.118 , pp. 422-425
    • Davidson, M.B.1    Castellanos, M.2    Kain, D.3
  • 22
    • 23944433439 scopus 로고    scopus 로고
    • The DiGEM trial protocol-a randomised controlled trial to determine the effect on glycaemic control of different strategies of blood glucose self-monitoring in people with type 2 diabetes
    • Farmer A., Wade A., French D.P., Goyder E., Kinmonth A.L., and Neil A. The DiGEM trial protocol-a randomised controlled trial to determine the effect on glycaemic control of different strategies of blood glucose self-monitoring in people with type 2 diabetes. BMC Fam Pract 6 (2005) 25
    • (2005) BMC Fam Pract , vol.6 , pp. 25
    • Farmer, A.1    Wade, A.2    French, D.P.3    Goyder, E.4    Kinmonth, A.L.5    Neil, A.6
  • 23
    • 33746604294 scopus 로고    scopus 로고
    • Is self-monitoring of blood glucose appropriate for all type 2 diabetic patients? The Fremantle Diabetes Study
    • Davis W.A., Bruce D.G., and Davis T.M.E. Is self-monitoring of blood glucose appropriate for all type 2 diabetic patients? The Fremantle Diabetes Study. Diabetes Care 29 (2006) 1764-1770
    • (2006) Diabetes Care , vol.29 , pp. 1764-1770
    • Davis, W.A.1    Bruce, D.G.2    Davis, T.M.E.3
  • 24
    • 31844437604 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: an epidemiological cohort study
    • Martin S., Schneider B., Heinemann L., et al. Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: an epidemiological cohort study. Diabetologia. 49 (2006) 271-278
    • (2006) Diabetologia. , vol.49 , pp. 271-278
    • Martin, S.1    Schneider, B.2    Heinemann, L.3
  • 25
    • 34447636939 scopus 로고    scopus 로고
    • Impact of self monitoring of blood glucose in the management of patients with non-insulin treated diabetes: open parallel group randomised trial
    • Farmer A., Wade A., Goyder E., et al. Impact of self monitoring of blood glucose in the management of patients with non-insulin treated diabetes: open parallel group randomised trial. BMJ 335 (2007) 132
    • (2007) BMJ , vol.335 , pp. 132
    • Farmer, A.1    Wade, A.2    Goyder, E.3
  • 27
    • 44449096635 scopus 로고    scopus 로고
    • Cost effectiveness of self monitoring of blood glucose in patients with non-insulin treated type 2 diabetes: economic evaluation of data from the DiGEM trial
    • Simon J., Gray A., Clarke P., et al. Cost effectiveness of self monitoring of blood glucose in patients with non-insulin treated type 2 diabetes: economic evaluation of data from the DiGEM trial. BMJ 336 (2008) 1177-1180
    • (2008) BMJ , vol.336 , pp. 1177-1180
    • Simon, J.1    Gray, A.2    Clarke, P.3
  • 28
    • 44449103216 scopus 로고    scopus 로고
    • Efficacy of self monitoring of blood glucose in patients with newly diagnosed type 2 diabetes (ESMON study): randomised controlled trial
    • O'Kane M.J., Bunting B., Copeland M., Coates V.E., and ESMON study group. Efficacy of self monitoring of blood glucose in patients with newly diagnosed type 2 diabetes (ESMON study): randomised controlled trial. BMJ 336 (2008) 1174-1177
    • (2008) BMJ , vol.336 , pp. 1174-1177
    • O'Kane, M.J.1    Bunting, B.2    Copeland, M.3    Coates, V.E.4    ESMON study group5
  • 29
    • 41149098928 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose in type 2 diabetes: a new look at published trials
    • Kempf K., Neukirchen W., Martin S., and Kolb H. Self-monitoring of blood glucose in type 2 diabetes: a new look at published trials. Diabetologia 51 (2008) 686-688
    • (2008) Diabetologia , vol.51 , pp. 686-688
    • Kempf, K.1    Neukirchen, W.2    Martin, S.3    Kolb, H.4
  • 30
    • 34548616859 scopus 로고    scopus 로고
    • Self monitoring of blood glucose in type 2 diabetes: longitudinal qualitative study of patients' perspectives
    • Peel E., Douglas M., and Lawton J. Self monitoring of blood glucose in type 2 diabetes: longitudinal qualitative study of patients' perspectives. BMJ 335 (2007) 493
    • (2007) BMJ , vol.335 , pp. 493
    • Peel, E.1    Douglas, M.2    Lawton, J.3
  • 31
    • 24144459072 scopus 로고    scopus 로고
    • International Federation of Clinical Chemistry Scientific Division Working Group on Selective Electrodes and Point of Care Testing. Approved IFCC recommendation on reporting results for blood glucose
    • D'Orazio P., Burnett R.W., Fogh-Andersen N., et al. International Federation of Clinical Chemistry Scientific Division Working Group on Selective Electrodes and Point of Care Testing. Approved IFCC recommendation on reporting results for blood glucose. Clin Chem 51 (2005) 1573-1576
    • (2005) Clin Chem , vol.51 , pp. 1573-1576
    • D'Orazio, P.1    Burnett, R.W.2    Fogh-Andersen, N.3
  • 32
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring in cardiovascular surgery
    • Clark Jr. L.C., and Lyons C. Electrode systems for continuous monitoring in cardiovascular surgery. Ann N Y Acad Sci 102 (1962) 29-45
    • (1962) Ann N Y Acad Sci , vol.102 , pp. 29-45
    • Clark Jr., L.C.1    Lyons, C.2
  • 33
    • 13844316705 scopus 로고    scopus 로고
    • Resource guide 2005. Blood glucose meters and data management system
    • American Diabetes Association. Resource guide 2005. Blood glucose meters and data management system. Diabetes Forecast 58 (2005) RG36-46
    • (2005) Diabetes Forecast , vol.58
    • American Diabetes Association1
  • 34
    • 38649115012 scopus 로고    scopus 로고
    • Evaluation of point-of-care glucose testing accuracy using locally-smoothed median absolute difference curves
    • Kost G.J., Tran N.K., Abad V.J., and Louie R.F. Evaluation of point-of-care glucose testing accuracy using locally-smoothed median absolute difference curves. Clin Chim Acta 389 (2008) 31-39
    • (2008) Clin Chim Acta , vol.389 , pp. 31-39
    • Kost, G.J.1    Tran, N.K.2    Abad, V.J.3    Louie, R.F.4
  • 35
    • 34249902075 scopus 로고    scopus 로고
    • Assessing the quality of glucose monitor studies: a critical evaluation of published reports
    • Mahoney J., and Ellison J. Assessing the quality of glucose monitor studies: a critical evaluation of published reports. Clin Chem 53 (2007) 1122-1128
    • (2007) Clin Chem , vol.53 , pp. 1122-1128
    • Mahoney, J.1    Ellison, J.2
  • 36
    • 0035036668 scopus 로고    scopus 로고
    • IFCC recommendation on reporting results for blood glucose
    • Burnett R.W., D'Orazio P., Fogh-Andersen N., et al. IFCC recommendation on reporting results for blood glucose. Clin Chim Acta 307 (2001) 205-209
    • (2001) Clin Chim Acta , vol.307 , pp. 205-209
    • Burnett, R.W.1    D'Orazio, P.2    Fogh-Andersen, N.3
  • 37
    • 2642541633 scopus 로고    scopus 로고
    • Standardized evaluation of instruments for self-monitoring of blood glucose by patients and a technologist
    • Kristensen G.B., Nerhus K., Thue G., and Sandberg S. Standardized evaluation of instruments for self-monitoring of blood glucose by patients and a technologist. Clin Chem 50 (2004) 1068-1071
    • (2004) Clin Chem , vol.50 , pp. 1068-1071
    • Kristensen, G.B.1    Nerhus, K.2    Thue, G.3    Sandberg, S.4
  • 39
    • 0030066052 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose
    • American Diabetes Association. Self-monitoring of blood glucose. Diabetes Care 19 Suppl 1 (1996) S62-S66
    • (1996) Diabetes Care , vol.19 , Issue.SUPPL. 1
    • American Diabetes Association1
  • 41
    • 3342992259 scopus 로고    scopus 로고
    • In vitro diagnostic test systems-requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus
    • ISO, Geneva, Switzerland
    • International Organization for Standardization. In vitro diagnostic test systems-requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus. ISO/TC 212/SC. Final Draft International Standard ISO/FDIS 15197 (2003), ISO, Geneva, Switzerland
    • (2003) ISO/TC 212/SC. Final Draft International Standard ISO/FDIS 15197
    • International Organization for Standardization1
  • 42
    • 38649086009 scopus 로고    scopus 로고
    • Meeting the challenge of the International Standard ISO 15197 for capillary glucose accuracy
    • Kost G.J., Louie R., Veerasamy N., et al. Meeting the challenge of the International Standard ISO 15197 for capillary glucose accuracy. Clin Chem 51 (2005) A255
    • (2005) Clin Chem , vol.51
    • Kost, G.J.1    Louie, R.2    Veerasamy, N.3
  • 44
    • 0031938405 scopus 로고    scopus 로고
    • Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care/hospital/ambulatory patients in the United States and Canada
    • Kost G.J., Vu H.T., Lee J.H., et al. Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care/hospital/ambulatory patients in the United States and Canada. Crit Care Med 26 (1998) 581-590
    • (1998) Crit Care Med , vol.26 , pp. 581-590
    • Kost, G.J.1    Vu, H.T.2    Lee, J.H.3
  • 45
    • 0026671274 scopus 로고
    • Implementation of capillary blood glucose monitoring in a teaching hospital and determination of program requirements to maintain quality testing
    • Lewandrowski K., Cheek R., Nathan D.M., et al. Implementation of capillary blood glucose monitoring in a teaching hospital and determination of program requirements to maintain quality testing. Am J Med 93 (1992) 419-426
    • (1992) Am J Med , vol.93 , pp. 419-426
    • Lewandrowski, K.1    Cheek, R.2    Nathan, D.M.3
  • 46
    • 33745461465 scopus 로고    scopus 로고
    • Results and feasibility of an external quality assessment scheme for self-monitoring of blood glucose
    • Kristensen G.B., Nerhus K., Thue G., and Sandberg S. Results and feasibility of an external quality assessment scheme for self-monitoring of blood glucose. Clin Chem 52 (2006) 1311-1317
    • (2006) Clin Chem , vol.52 , pp. 1311-1317
    • Kristensen, G.B.1    Nerhus, K.2    Thue, G.3    Sandberg, S.4
  • 47
    • 10244261555 scopus 로고    scopus 로고
    • Feasibility of a quality assurance programme of bedside blood glucose testing in a hospital setting: 7 years' experience
    • Nobels F., Beckers F., Bailleul E., De Schrijver P., Sierens L., and Van Crombrugge P. Feasibility of a quality assurance programme of bedside blood glucose testing in a hospital setting: 7 years' experience. Diabet Med 21 (2004) 1288-1291
    • (2004) Diabet Med , vol.21 , pp. 1288-1291
    • Nobels, F.1    Beckers, F.2    Bailleul, E.3    De Schrijver, P.4    Sierens, L.5    Van Crombrugge, P.6
  • 49
    • 84984945194 scopus 로고    scopus 로고
    • Multicenter study of the prevalence of blood contamination on Point-of-Care Glucose Meters and recommendations for controlling contamination
    • Louie R., Lau M., Lee J., Tang Z., and Kost G. Multicenter study of the prevalence of blood contamination on Point-of-Care Glucose Meters and recommendations for controlling contamination. Point of Care 4 (2005) 158-163
    • (2005) Point of Care , vol.4 , pp. 158-163
    • Louie, R.1    Lau, M.2    Lee, J.3    Tang, Z.4    Kost, G.5
  • 50
    • 33644847768 scopus 로고    scopus 로고
    • Effect of adverse storage conditions on performance of glucometer test strips
    • Bamberg R., Schulman K., MacKenzie M., Moore J., and Olchesky S. Effect of adverse storage conditions on performance of glucometer test strips. Clin Lab Sci 18 (2005) 203-209
    • (2005) Clin Lab Sci , vol.18 , pp. 203-209
    • Bamberg, R.1    Schulman, K.2    MacKenzie, M.3    Moore, J.4    Olchesky, S.5
  • 51
    • 0036597372 scopus 로고    scopus 로고
    • Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites
    • Ellison J.M., Stegmann J.M., Colner S.L., et al. Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites. Diabetes Care 25 (2002) 961-964
    • (2002) Diabetes Care , vol.25 , pp. 961-964
    • Ellison, J.M.1    Stegmann, J.M.2    Colner, S.L.3
  • 52
    • 0033843815 scopus 로고    scopus 로고
    • Potential for error from underfilling Glucometer Elite test strips
    • Wiener K. Potential for error from underfilling Glucometer Elite test strips. Diabet Med 17 (2000) 555-556
    • (2000) Diabet Med , vol.17 , pp. 555-556
    • Wiener, K.1
  • 53
    • 0023888222 scopus 로고
    • Effect of hematocrit concentration on blood glucose value determined on Glucometer II
    • Barreau P.B., and Buttery J.E. Effect of hematocrit concentration on blood glucose value determined on Glucometer II. Diabetes Care. 11 (1988) 116-118
    • (1988) Diabetes Care. , vol.11 , pp. 116-118
    • Barreau, P.B.1    Buttery, J.E.2
  • 54
    • 20344392145 scopus 로고    scopus 로고
    • Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction
    • Rao L.V., Jakubiak F., Sidwell J.S., Winkelman J.W., and Snyder M.L. Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction. Clin Chim Acta 356 (2005) 178-183
    • (2005) Clin Chim Acta , vol.356 , pp. 178-183
    • Rao, L.V.1    Jakubiak, F.2    Sidwell, J.S.3    Winkelman, J.W.4    Snyder, M.L.5
  • 55
    • 0033849382 scopus 로고    scopus 로고
    • Effects of different hematocrit levels on glucose measurements with handheld meters for point of care testing
    • Tang Z., Lee J.H., Louie R.F., and Kost G.J. Effects of different hematocrit levels on glucose measurements with handheld meters for point of care testing. Arch Pathol Lab Med 124 (2000) 1135-1140
    • (2000) Arch Pathol Lab Med , vol.124 , pp. 1135-1140
    • Tang, Z.1    Lee, J.H.2    Louie, R.F.3    Kost, G.J.4
  • 56
    • 0024577154 scopus 로고
    • Screening for hypoglycaemia with plasma in neonatal blood of high hematocrit value
    • Kaplan M., Blondheim O., and Alon I. Screening for hypoglycaemia with plasma in neonatal blood of high hematocrit value. Crit Care Med 17 (1989) 279-282
    • (1989) Crit Care Med , vol.17 , pp. 279-282
    • Kaplan, M.1    Blondheim, O.2    Alon, I.3
  • 57
    • 0027214655 scopus 로고
    • The effect of variations in hematocrit, mean cell volume and red blood count on reagent strip tests for glucose
    • Kilpatrick E.S., Rumley A.G., and Myin H. The effect of variations in hematocrit, mean cell volume and red blood count on reagent strip tests for glucose. Ann Clin Biochem 30 (1993) 485-487
    • (1993) Ann Clin Biochem , vol.30 , pp. 485-487
    • Kilpatrick, E.S.1    Rumley, A.G.2    Myin, H.3
  • 58
    • 38149122251 scopus 로고    scopus 로고
    • Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers
    • Mann E.A., Salinas J., Pidcoke H.F., Wolf S.E., Holcomb J.B., and Wade C.E. Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers. J Trauma 64 (2008) 15-20
    • (2008) J Trauma , vol.64 , pp. 15-20
    • Mann, E.A.1    Salinas, J.2    Pidcoke, H.F.3    Wolf, S.E.4    Holcomb, J.B.5    Wade, C.E.6
  • 59
    • 34548306928 scopus 로고    scopus 로고
    • Interference of maltose, icodextrin, galactose, or xylose with some blood glucose monitoring systems
    • Schleis T.G. Interference of maltose, icodextrin, galactose, or xylose with some blood glucose monitoring systems. Pharmacotherapy 27 (2007) 1313-1321
    • (2007) Pharmacotherapy , vol.27 , pp. 1313-1321
    • Schleis, T.G.1
  • 60
    • 0031949345 scopus 로고    scopus 로고
    • Toxic levels of acetaminophen produce a major positive interference on Glucometer Elite and Accu-chek Advantage glucose meters
    • Cartier L.J., Leclerc P., Pouliot M., Nadeau L., Turcotte G., and Fruteau-de-Laclos B. Toxic levels of acetaminophen produce a major positive interference on Glucometer Elite and Accu-chek Advantage glucose meters. Clin Chem 44 (1998) 893-894
    • (1998) Clin Chem , vol.44 , pp. 893-894
    • Cartier, L.J.1    Leclerc, P.2    Pouliot, M.3    Nadeau, L.4    Turcotte, G.5    Fruteau-de-Laclos, B.6
  • 61
    • 0026687889 scopus 로고
    • An overview of minimally invasive technologies
    • Ginsberg B.H. An overview of minimally invasive technologies. Clin Chem 38 (1992) 1596-1600
    • (1992) Clin Chem , vol.38 , pp. 1596-1600
    • Ginsberg, B.H.1
  • 62
    • 0001340335 scopus 로고    scopus 로고
    • Glucose sensors in the mid-1990s
    • Kaufman F. Glucose sensors in the mid-1990s. Diabetes Annu 10 (1996) 251-257
    • (1996) Diabetes Annu , vol.10 , pp. 251-257
    • Kaufman, F.1
  • 64
    • 0032995738 scopus 로고    scopus 로고
    • Spectroscopic and clinical aspects of noninvasive glucose measurements
    • Khalil O.S. Spectroscopic and clinical aspects of noninvasive glucose measurements. Clin Chem 45 (1999) 165-177
    • (1999) Clin Chem , vol.45 , pp. 165-177
    • Khalil, O.S.1
  • 65
    • 33645051466 scopus 로고    scopus 로고
    • Continuous glucose monitoring and closed-loop systems
    • Hovorka R. Continuous glucose monitoring and closed-loop systems. Diabet Med 23 (2006) 1-12
    • (2006) Diabet Med , vol.23 , pp. 1-12
    • Hovorka, R.1
  • 66
    • 54749108405 scopus 로고    scopus 로고
    • Clinical use of real-time continuous glucose monitoring
    • Battelino T., and Bolinder J. Clinical use of real-time continuous glucose monitoring. Curr Diabetes Rev 4 (2008) 218-222
    • (2008) Curr Diabetes Rev , vol.4 , pp. 218-222
    • Battelino, T.1    Bolinder, J.2
  • 67
    • 0033759474 scopus 로고    scopus 로고
    • Can interstitial glucose assessment replace blood glucose measurements?
    • Rebrin K., and Steil G. Can interstitial glucose assessment replace blood glucose measurements?. Diabetes Technol Ther 2 (2000) 461-472
    • (2000) Diabetes Technol Ther , vol.2 , pp. 461-472
    • Rebrin, K.1    Steil, G.2
  • 68
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial
    • Garg S., Zisser H., Schwartz S., et al. Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. Diabetes Care 29 (2006) 44-50
    • (2006) Diabetes Care , vol.29 , pp. 44-50
    • Garg, S.1    Zisser, H.2    Schwartz, S.3
  • 69
    • 0037386040 scopus 로고    scopus 로고
    • Use of the GlucoWatch Biographer in children with type 1 diabetes
    • Chase H.P., Roberts M.D., Wightman C., et al. Use of the GlucoWatch Biographer in children with type 1 diabetes. Pediatrics 111 (2003) 790-794
    • (2003) Pediatrics , vol.111 , pp. 790-794
    • Chase, H.P.1    Roberts, M.D.2    Wightman, C.3
  • 70
    • 0034117324 scopus 로고    scopus 로고
    • Performance evaluation of the MiniMed Continuous Glucose Monitoring System during patient home use
    • Gross T.M., Bode B.W., Einhorn D., et al. Performance evaluation of the MiniMed Continuous Glucose Monitoring System during patient home use. Diabetes Technol Ther 2 (2000) 49-56
    • (2000) Diabetes Technol Ther , vol.2 , pp. 49-56
    • Gross, T.M.1    Bode, B.W.2    Einhorn, D.3
  • 71
    • 33845616782 scopus 로고    scopus 로고
    • Microdialysis-based 48-hour continuous glucose monitoring with GlucoDay: clinical performance and patients' acceptance
    • Kubiak T., Wörle B., Kuhr B., et al. Microdialysis-based 48-hour continuous glucose monitoring with GlucoDay: clinical performance and patients' acceptance. Diabetes Technol Ther 8 (2006) 570-575
    • (2006) Diabetes Technol Ther , vol.8 , pp. 570-575
    • Kubiak, T.1    Wörle, B.2    Kuhr, B.3
  • 72
    • 33845660357 scopus 로고    scopus 로고
    • Clinical experience with an integrated continuous glucose sensor/insulin pump platform: a feasibility study
    • Mastrototaro J.J., Cooper K.W., Soundararajan G., Sanders J.B., and Shah R.V. Clinical experience with an integrated continuous glucose sensor/insulin pump platform: a feasibility study. Adv Ther 23 (2006) 725-732
    • (2006) Adv Ther , vol.23 , pp. 725-732
    • Mastrototaro, J.J.1    Cooper, K.W.2    Soundararajan, G.3    Sanders, J.B.4    Shah, R.V.5
  • 73
    • 0032842227 scopus 로고    scopus 로고
    • Analytical characterization of electrochemical biosensor test strips for measurement of glucose in low-volume interstitial fluid samples
    • Collison M.E., Stout P.J., Glushko T.S., et al. Analytical characterization of electrochemical biosensor test strips for measurement of glucose in low-volume interstitial fluid samples. Clin Chem 45 (1999) 1665-1673
    • (1999) Clin Chem , vol.45 , pp. 1665-1673
    • Collison, M.E.1    Stout, P.J.2    Glushko, T.S.3
  • 75
    • 0031257640 scopus 로고    scopus 로고
    • Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
    • Bantle J.P., and Thomas W. Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid. J Lab Clin Med 130 (1997) 436-441
    • (1997) J Lab Clin Med , vol.130 , pp. 436-441
    • Bantle, J.P.1    Thomas, W.2
  • 76
    • 0242300688 scopus 로고    scopus 로고
    • The accuracy of the GlucoWatch G2 Biographer in children with type 1 diabetes: results of the Diabetes Research in Children Network (DirecNet) accuracy study
    • Diabetes Research in Children Network (DirecNet) Study Group. The accuracy of the GlucoWatch G2 Biographer in children with type 1 diabetes: results of the Diabetes Research in Children Network (DirecNet) accuracy study. Diabetes Technol Ther 5 (2003) 791-800
    • (2003) Diabetes Technol Ther , vol.5 , pp. 791-800
    • Diabetes Research in Children Network (DirecNet) Study Group1
  • 77
    • 1442275324 scopus 로고    scopus 로고
    • Accuracy of the GlucoWatch G2 Biographer and the Continuous Glucose Monitoring System during hypoglycemia: experience of the Diabetes Research in Children Network
    • Diabetes Research in Children Network (DirecNet) Study Group. Accuracy of the GlucoWatch G2 Biographer and the Continuous Glucose Monitoring System during hypoglycemia: experience of the Diabetes Research in Children Network. Diabetes Care 27 (2004) 722-726
    • (2004) Diabetes Care , vol.27 , pp. 722-726
    • Diabetes Research in Children Network (DirecNet) Study Group1
  • 78
    • 58149391125 scopus 로고    scopus 로고
    • Continuous glucose monitoring and type 1 diabetes
    • Montagnana M, Lippi G, Guidi GC. Continuous glucose monitoring and type 1 diabetes. N Engl J Med 2009;360:190.
    • (2009) N Engl J Med , vol.360 , pp. 190
    • Montagnana, M.1    Lippi, G.2    Guidi, G.C.3
  • 79
    • 27644556801 scopus 로고    scopus 로고
    • A review of continuous glucose monitoring technology
    • Klonoff D.C. A review of continuous glucose monitoring technology. Diabetes Technol Ther 7 (2005) 770-775
    • (2005) Diabetes Technol Ther , vol.7 , pp. 770-775
    • Klonoff, D.C.1
  • 82
    • 0036302980 scopus 로고    scopus 로고
    • Telemedicine as a tool for intensive management of diabetes: the DIABTel experience
    • Gómez E.J., Hernando M.E., García A., et al. Telemedicine as a tool for intensive management of diabetes: the DIABTel experience. Comput Methods Programs Biomed 69 (2002) 163-177
    • (2002) Comput Methods Programs Biomed , vol.69 , pp. 163-177
    • Gómez, E.J.1    Hernando, M.E.2    García, A.3
  • 83
    • 43549083277 scopus 로고    scopus 로고
    • Real-time continuous glucose monitoring together with telemedical assistance improves glycemic control and glucose stability in pump-treated patients
    • Rigla M., Hernando M.E., Gómez E.J., et al. Real-time continuous glucose monitoring together with telemedical assistance improves glycemic control and glucose stability in pump-treated patients. Diabetes Technol Ther 10 (2008) 194-199
    • (2008) Diabetes Technol Ther , vol.10 , pp. 194-199
    • Rigla, M.1    Hernando, M.E.2    Gómez, E.J.3
  • 85
    • 0034780780 scopus 로고    scopus 로고
    • Preventing medical errors in point-of-care testing: security, validation, safeguards, and connectivity
    • Kost G.J. Preventing medical errors in point-of-care testing: security, validation, safeguards, and connectivity. Arch Pathol Lab Med 125 (2001) 1307-1315
    • (2001) Arch Pathol Lab Med , vol.125 , pp. 1307-1315
    • Kost, G.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.