메뉴 건너뛰기




Volumn 29, Issue 2, 2009, Pages 466-473

Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imaging

Author keywords

Constrained reconstruction; Myocardial perfusion; Radial; Total variation; Undersampled

Indexed keywords

ARTICLE; CONTROLLED STUDY; HEART BEAT; HEART MUSCLE PERFUSION; HUMAN; IMAGE ANALYSIS; INFORMATION PROCESSING; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 60549090085     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21585     Document Type: Article
Times cited : (132)

References (26)
  • 1
    • 17644412367 scopus 로고    scopus 로고
    • Coronary artery disease: Myocardial perfusion MR imaging with sensitivity encoding versus conventional angiography
    • Plein S, Radjenovic A, Ridgway JP, Barmby D, Greenwood JP, et al. Coronary artery disease: myocardial perfusion MR imaging with sensitivity encoding versus conventional angiography. Radiology 2005;235:423-430.
    • (2005) Radiology , vol.235 , pp. 423-430
    • Plein, S.1    Radjenovic, A.2    Ridgway, J.P.3    Barmby, D.4    Greenwood, J.P.5
  • 2
    • 0242432559 scopus 로고    scopus 로고
    • Comparison of temporal filtering methods for dynamic contrast MRI myocardial perfusion studies
    • DiBella EVR, Wu YJ, Alexander AL, Parker DL, Green D, et al. Comparison of temporal filtering methods for dynamic contrast MRI myocardial perfusion studies. Magn Reson Med 2003;49:895-902.
    • (2003) Magn Reson Med , vol.49 , pp. 895-902
    • DiBella, E.V.R.1    Wu, Y.J.2    Alexander, A.L.3    Parker, D.L.4    Green, D.5
  • 3
    • 32544440010 scopus 로고    scopus 로고
    • Extension of the UNFOLD method to include free breathing
    • Madore B, Hoge WS, Kwong R. Extension of the UNFOLD method to include free breathing. Magn Reson Med 2006;55:352-362.
    • (2006) Magn Reson Med , vol.55 , pp. 352-362
    • Madore, B.1    Hoge, W.S.2    Kwong, R.3
  • 7
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 8
    • 27644587498 scopus 로고    scopus 로고
    • On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies
    • DiBella EVR, Parker DL, Sinusas AJ. On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies. Magn Reson Med 2005;54:1295-1299.
    • (2005) Magn Reson Med , vol.54 , pp. 1295-1299
    • DiBella, E.V.R.1    Parker, D.L.2    Sinusas, A.J.3
  • 9
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58:1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 15
    • 0033646318 scopus 로고    scopus 로고
    • k-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI
    • Song HK, DoughertyL. k-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI. Magn Reson Med 2000;44:825-832.
    • (2000) Magn Reson Med , vol.44 , pp. 825-832
    • Song, H.K.1    DoughertyL2
  • 16
    • 0034900220 scopus 로고    scopus 로고
    • Quantification of the effect of water exchange in dynamic contrast enhanced MRI perfusion measurements in the brain and heart
    • Larsson HBW, Rosenbaum S, Fritz-Hansen T. Quantification of the effect of water exchange in dynamic contrast enhanced MRI perfusion measurements in the brain and heart. Magn Reson Med 2001;46:272-281.
    • (2001) Magn Reson Med , vol.46 , pp. 272-281
    • Larsson, H.B.W.1    Rosenbaum, S.2    Fritz-Hansen, T.3
  • 17
    • 34248191402 scopus 로고    scopus 로고
    • Perfusion MRI with radial acquisition for arterial input function assessment
    • Kholmovski EG, DiBella EVR. Perfusion MRI with radial acquisition for arterial input function assessment. Magn Reson Med 2007;57:821-827.
    • (2007) Magn Reson Med , vol.57 , pp. 821-827
    • Kholmovski, E.G.1    DiBella, E.V.R.2
  • 18
    • 27544442176 scopus 로고    scopus 로고
    • Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
    • Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ. Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Investig Radiol 2005;40:715-724.
    • (2005) Investig Radiol , vol.40 , pp. 715-724
    • Rohrer, M.1    Bauer, H.2    Mintorovitch, J.3    Requardt, M.4    Weinmann, H.J.5
  • 19
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainity principles: Exact signal reconstruction from highly incomplete frequency information
    • Candes E, Romberg J, Tao T. Robust uncertainity principles: exact signal reconstruction from highly incomplete frequency information. IEEE Trans Information Theory 2006;52:489-509.
    • (2006) IEEE Trans Information Theory , vol.52 , pp. 489-509
    • Candes, E.1    Romberg, J.2    Tao, T.3
  • 20
    • 34250380862 scopus 로고    scopus 로고
    • Robust radial imaging with predetermined isotropic gradient delay correction (abstract 2379)
    • Seattle;
    • Speier P, Trautwein F. Robust radial imaging with predetermined isotropic gradient delay correction (abstract 2379). In: Proceedings of the 14th Annual Meeting of ISMRM, Seattle; 2006.
    • (2006) Proceedings of the 14th Annual Meeting of ISMRM
    • Speier, P.1    Trautwein, F.2
  • 21
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • Rudin LI, Osher S, Fatemi E. Nonlinear total variation based noise removal algorithms. Physica D 1992;60:259-268.
    • (1992) Physica D , vol.60 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 22
    • 36149030663 scopus 로고
    • Analysis of bounded variation penalty methods for ill-posed problems
    • Acar R, Vogel CR. Analysis of bounded variation penalty methods for ill-posed problems. Inverse Problems 1994;10:1217-1229.
    • (1994) Inverse Problems , vol.10 , pp. 1217-1229
    • Acar, R.1    Vogel, C.R.2
  • 23
    • 0000236333 scopus 로고    scopus 로고
    • The L-curve and its use in the numerical treatment of inverse problems
    • Johnston P, editor, Southampton, UK: WIT Press; p
    • Hansen PC. 2001. The L-curve and its use in the numerical treatment of inverse problems. In: Johnston P, editor. Computational inverse problems in electrocardiology. Southampton, UK: WIT Press; p 119-142.
    • (2001) Computational inverse problems in electrocardiology , pp. 119-142
    • Hansen, P.C.1
  • 24
    • 45849103511 scopus 로고    scopus 로고
    • Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics
    • Dietrich O, Raya JG, Reeder SB, Ingrisch M, Reiser MF, Schoen-berg SO. Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics. Magn Reson Imaging 2008;26:754-762.
    • (2008) Magn Reson Imaging , vol.26 , pp. 754-762
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Ingrisch, M.4    Reiser, M.F.5    Schoen-berg, S.O.6
  • 25
    • 3042759869 scopus 로고    scopus 로고
    • Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance
    • Gatehouse PD, Elkington AG, Ablitt NA, Yang GZ, Pennell DJ, Firmin DN. Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance. J Magn Reson Imaging 2004;20:39-45.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 39-45
    • Gatehouse, P.D.1    Elkington, A.G.2    Ablitt, N.A.3    Yang, G.Z.4    Pennell, D.J.5    Firmin, D.N.6
  • 26
    • 60549085720 scopus 로고    scopus 로고
    • A comparison of L1 and L2 norms as temporal constraints for reconstruction of undersampled dynamic contrast enhanced cardiac scans with respiratory motion (Abstract 340)
    • Toronto;
    • Adluru G, Di Bella EVR. A comparison of L1 and L2 norms as temporal constraints for reconstruction of undersampled dynamic contrast enhanced cardiac scans with respiratory motion (Abstract 340). In: Proceedings of 16th ISMRM, Toronto; 2008.
    • (2008) Proceedings of 16th ISMRM
    • Adluru, G.1    Di Bella, E.V.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.