메뉴 건너뛰기




Volumn 51, Issue 1, 2004, Pages 200-204

Extended Coverage First-Pass Perfusion Imaging Using Slice-Interleaved TSENSE

Author keywords

Contrast agent; Heart; MRI; Perfusion; SENSE; TSENSE

Indexed keywords

HEART; MAGNETIC RESONANCE IMAGING;

EID: 0345742630     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10663     Document Type: Article
Times cited : (66)

References (11)
  • 1
    • 0031899389 scopus 로고    scopus 로고
    • Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI
    • Ding S, Wolff SD, Epstein FH. Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI. Magn Reson Med 1998;39:514-519.
    • (1998) Magn Reson Med , vol.39 , pp. 514-519
    • Ding, S.1    Wolff, S.D.2    Epstein, F.H.3
  • 3
    • 0035078795 scopus 로고    scopus 로고
    • First-pass myocardial perfusion MR imaging with interleaved notched saturation: Feasibility study
    • Slavin GS, Wolff SD, Gupta SN, Foo TK. First-pass myocardial perfusion MR imaging with interleaved notched saturation: feasibility study. Radiology 2001;219:258-263.
    • (2001) Radiology , vol.219 , pp. 258-263
    • Slavin, G.S.1    Wolff, S.D.2    Gupta, S.N.3    Foo, T.K.4
  • 4
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • Madore B, Glover GH, Pelc NJ. Unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn Reson Med 1999;42:813-828,
    • (1999) Magn Reson Med , vol.42 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 5
    • 0347584136 scopus 로고    scopus 로고
    • First-pass cardiac MRI using UNFOLD
    • Epstein FH, Kellman P, McVeigh ER. First-pass cardiac MRI using UNFOLD. Radiology 2000;217:(Suppl)379.
    • (2000) Radiology , vol.217 , Issue.SUPPL. , pp. 379
    • Epstein, F.H.1    Kellman, P.2    McVeigh, E.R.3
  • 7
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001;45:846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 8
    • 0028113844 scopus 로고
    • The effect of high speed gradients on fast gradient echo imaging
    • Reeder SB, McVeigh ER. The effect of high speed gradients on fast gradient echo imaging. Magn Reson Med 1994;32:612-621.
    • (1994) Magn Reson Med , vol.32 , pp. 612-621
    • Reeder, S.B.1    McVeigh, E.R.2
  • 10
    • 0033646259 scopus 로고    scopus 로고
    • Low latency temporal filter design for real time interventional MR imaging using UNFOLD
    • Kellman P, Epstein FH, McVeigh ER. Low latency temporal filter design for real time interventional MR imaging using UNFOLD. Magn Reson Med 2000;44:933-939.
    • (2000) Magn Reson Med , vol.44 , pp. 933-939
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.