메뉴 건너뛰기




Volumn 54, Issue 11-12, 2008, Pages 423-438

Immunoassays & Co.: Past, present, future? - A review and outlook from personal experience and involvement over the past 35 years

Author keywords

Antibody; Antigen; Health care; History; Immunoassay; Methodology; Point of need; Point of care; Quality assessment; Trends

Indexed keywords

ANTIGEN;

EID: 60549086565     PISSN: 14336510     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (15)

References (166)
  • 3
    • 0000977149 scopus 로고
    • Quantitative aspects of the reaction between insulin and insulin-binding antibody
    • Berson SA, Yalow RS. Quantitative aspects of the reaction between insulin and insulin-binding antibody. J Clin Invest. 1959; 38: 1996-2016.
    • (1959) J Clin Invest , vol.38 , pp. 1996-2016
    • Berson, S.A.1    Yalow, R.S.2
  • 4
    • 0000380542 scopus 로고
    • Immunoassay of endogenous plasma insulin in man
    • Yalow RS, Berson SA. Immunoassay of endogenous plasma insulin in man. J Clin Invest. 1960; 39: 1157-75.
    • (1960) J Clin Invest , vol.39 , pp. 1157-1175
    • Yalow, R.S.1    Berson, S.A.2
  • 5
    • 36149060174 scopus 로고
    • Estimation of protein bound 131 I in plasma
    • Ekins R.P. Estimation of protein bound 131 I in plasma. Phys Med Biol. 1959; 4: 182-4.
    • (1959) Phys Med Biol , vol.4 , pp. 182-184
    • Ekins, R.P.1
  • 6
    • 0000767174 scopus 로고
    • The estimation of thyroxine in human plasma by an electrophoretic technique
    • Ekins R.P. The estimation of thyroxine in human plasma by an electrophoretic technique. Clin Chim Acta. 1960; 5:453-9.
    • (1960) Clin Chim Acta , vol.5 , pp. 453-459
    • Ekins, R.P.1
  • 9
    • 0013900536 scopus 로고
    • Radioimmunoassay for human luteinizing hormone. [My paper]
    • Odell WD, Ross GT, Rayford PL. Radioimmunoassay for human luteinizing hormone. [My paper] Metabolism. 1966; 15: 287-9.
    • (1966) Metabolism , vol.15 , pp. 287-289
    • Odell, W.D.1    Ross, G.T.2    Rayford, P.L.3
  • 10
    • 0014385908 scopus 로고
    • Radioimmunoassay of ACTH in plasma. [My paper]
    • Berson SA, Yalow RS. Radioimmunoassay of ACTH in plasma. [My paper] J Clin Invest. 1968; 47: 2725-51.
    • (1968) J Clin Invest , vol.47 , pp. 2725-2751
    • Berson, S.A.1    Yalow, R.S.2
  • 11
    • 0014169267 scopus 로고
    • Studies of thyrotropin physiology by means of radioimmunoassay
    • Odell WD, Wilber JF, Utiger RD. Studies of thyrotropin physiology by means of radioimmunoassay. Recent Prog Horm Res. 1967; 23: 47-85.
    • (1967) Recent Prog Horm Res , vol.23 , pp. 47-85
    • Odell, W.D.1    Wilber, J.F.2    Utiger, R.D.3
  • 12
    • 0014222324 scopus 로고
    • Luteinizing hormone activity in plasma during the menstrual cycle
    • Ross GT, Odell WD, Rayford PL. Luteinizing hormone activity in plasma during the menstrual cycle. Science 1967; 155: 1679-80.
    • (1967) Science , vol.155 , pp. 1679-1680
    • Ross, G.T.1    Odell, W.D.2    Rayford, P.L.3
  • 13
    • 0014436556 scopus 로고
    • Immunoradiometric assay of human growth hormone
    • Miles LE, Hales CN, Immunoradiometric assay of human growth hormone. Lancet 1968; 2 (7566): 492-3.
    • (1968) Lancet , vol.2 , Issue.7566 , pp. 492-493
    • Miles, L.E.1    Hales, C.N.2
  • 14
    • 0015116634 scopus 로고
    • Enzyme-linked immununosorbent assay (ELISA) Quantitative assay of immunoglobulin G
    • Engvall E, Perlmann P. Enzyme-linked immununosorbent assay (ELISA) Quantitative assay of immunoglobulin G. Immunochemistry 1971; 8: 871-4.
    • (1971) Immunochemistry , vol.8 , pp. 871-874
    • Engvall, E.1    Perlmann, P.2
  • 16
    • 0029827838 scopus 로고    scopus 로고
    • Immunoradiometric and luminescence immunoenzymometric assay of human thyrotropin from dried blood spots for screening of neonatal hypothyroidism
    • Jirkalova V, Cap J, Strakova H, Pribysova J, Plicka J, Lomsky R. Immunoradiometric and luminescence immunoenzymometric assay of human thyrotropin from dried blood spots for screening of neonatal hypothyroidism Eur J Clin Chem Clin Biochem. 1996; 34: 823-7.
    • (1996) Eur J Clin Chem Clin Biochem , vol.34 , pp. 823-827
    • Jirkalova, V.1    Cap, J.2    Strakova, H.3    Pribysova, J.4    Plicka, J.5    Lomsky, R.6
  • 17
    • 60549094629 scopus 로고
    • Localization of tissue antigens with the fluorescent antibody technique: Application to human anterior pituitary hormones
    • Cruickshank B, Currie AR. Localization of tissue antigens with the fluorescent antibody technique: application to human anterior pituitary hormones. Immunology. 1958; 1: 13-26.
    • (1958) Immunology , vol.1 , pp. 13-26
    • Cruickshank, B.1    Currie, A.R.2
  • 18
    • 60549111260 scopus 로고
    • Methods for the detection of auto-antibodies
    • Torrigiani G. Methods for the detection of auto-antibodies. Acta Allergol. 1963;18: 489-94.
    • (1963) Acta Allergol , vol.18 , pp. 489-494
    • Torrigiani, G.1
  • 21
    • 0002550862 scopus 로고
    • Time-resolved fluoroimmunoassay, advantages and limitations
    • Eds. Van-Dyke K, Van-Dyke R, CRC Press, Boca Raton, Chapter 16, 233-53. ISBN 0-8493-5865-5
    • Lövgren T, Pettersson K. Time-resolved fluoroimmunoassay, advantages and limitations. In: Luminescence immunoassay and molecular applications, Eds. Van-Dyke K, Van-Dyke R, CRC Press, Boca Raton, 1990; Chapter 16, 233-53. ISBN 0-8493-5865-5.
    • (1990) Luminescence immunoassay and molecular applications
    • Lövgren, T.1    Pettersson, K.2
  • 22
    • 0003008520 scopus 로고
    • Time-resolved fluorometry
    • Eds. Hemmilä I, Ståhlberg T, Mottram P, Wallac Oy, Turku, Chapter 5, 83-119. ISBN 951-9489-29-0
    • Hemmilä I, Harju R. Time-resolved fluorometry. In: Bioanalytical applications of labelling technologies, Eds. Hemmilä I, Ståhlberg T, Mottram P, Wallac Oy, Turku, 1994; Chapter 5, 83-119. ISBN 951-9489-29-0.
    • (1994) Bioanalytical applications of labelling technologies
    • Hemmilä, I.1    Harju, R.2
  • 23
    • 0345476275 scopus 로고    scopus 로고
    • Analytical and clinical evaluation of TSH and thyroid hormones by electrochemiluminescent immunoassays
    • Sánchez-Carbayo M, Mauri M, Alfayate R, Miralles C, Soria F. Analytical and clinical evaluation of TSH and thyroid hormones by electrochemiluminescent immunoassays. Clin Biochem. 1999; 32: 395-403.
    • (1999) Clin Biochem , vol.32 , pp. 395-403
    • Sánchez-Carbayo, M.1    Mauri, M.2    Alfayate, R.3    Miralles, C.4    Soria, F.5
  • 24
    • 0024293251 scopus 로고
    • Preparation and characterization of singly labeled ruthenium polypyridine cytochrome c derivatives
    • Pan LP, Durham B, Wolinska J, Millett F. Preparation and characterization of singly labeled ruthenium polypyridine cytochrome c derivatives. Biochemistry 1988; 27: 7 180-7.
    • (1988) Biochemistry , vol.27 , Issue.7 , pp. 180-187
    • Pan, L.P.1    Durham, B.2    Wolinska, J.3    Millett, F.4
  • 26
    • 0029656004 scopus 로고    scopus 로고
    • Limitations of serum prostate specific antigen in predicting peripheral and transition zone cancer volumes as measured by correlation coefficients
    • Noldus J, Stamey TA Limitations of serum prostate specific antigen in predicting peripheral and transition zone cancer volumes as measured by correlation coefficients. J Urol. 1996; 155: 232-7.
    • (1996) J Urol , vol.155 , pp. 232-237
    • Noldus, J.1    Stamey, T.A.2
  • 29
    • 0020410472 scopus 로고
    • An evaluation of the sensitivity of five home pregnancy tests to known concentrations of human chorionic gonadotropin
    • Hanlon JT, Caiola SM, Muhlbaier LH, Dennis BH, Edelman DA, Dingfelder JR An evaluation of the sensitivity of five home pregnancy tests to known concentrations of human chorionic gonadotropin. Am J Obstet Gynecol. 1982; 144: 778-82.
    • (1982) Am J Obstet Gynecol , vol.144 , pp. 778-782
    • Hanlon, J.T.1    Caiola, S.M.2    Muhlbaier, L.H.3    Dennis, B.H.4    Edelman, D.A.5    Dingfelder, J.R.6
  • 30
    • 0035177781 scopus 로고    scopus 로고
    • Blind trials of an onsite saliva drug test for marijuana and opiates
    • Jehanli A, Brannan S, Moore L, Spiehler VR. Blind trials of an onsite saliva drug test for marijuana and opiates. J Forensic Sci. 2001; 46: 1214-20.
    • (2001) J Forensic Sci , vol.46 , pp. 1214-1220
    • Jehanli, A.1    Brannan, S.2    Moore, L.3    Spiehler, V.R.4
  • 31
    • 60549091023 scopus 로고
    • The measurement of neutralizing antibodies to streptococcal hyaluronidase by a turbidimetric method
    • Harris S, Harris TN. The measurement of neutralizing antibodies to streptococcal hyaluronidase by a turbidimetric method. J. Immunol. 1949: 63: 233-47.
    • (1949) J. Immunol , vol.63 , pp. 233-247
    • Harris, S.1    Harris, T.N.2
  • 32
    • 84948363012 scopus 로고    scopus 로고
    • Kreutzer HJ An immunological turbidimetric method for serum transferrin determination. J Clin Chem Clin Biochem. 1976; 14: 401-6.
    • Kreutzer HJ An immunological turbidimetric method for serum transferrin determination. J Clin Chem Clin Biochem. 1976; 14: 401-6.
  • 33
    • 0034108431 scopus 로고    scopus 로고
    • Evaluation of a sensitive immunoluminometric assay for the determination of C-reactive protein (CRP) in serum and plasma and the establishment of reference ranges for different groups of subjects
    • Wood WG, Lüdemann J, Mitusch R, Heinrich J, Maass R, Frick U. Evaluation of a sensitive immunoluminometric assay for the determination of C-reactive protein (CRP) in serum and plasma and the establishment of reference ranges for different groups of subjects. Clin Lab. 2000; 46: 131-40.
    • (2000) Clin Lab , vol.46 , pp. 131-140
    • Wood, W.G.1    Lüdemann, J.2    Mitusch, R.3    Heinrich, J.4    Maass, R.5    Frick, U.6
  • 34
    • 60549090078 scopus 로고
    • Cardiolipin antigen: Nephelometric measurements. I
    • Hartmann J. Cardiolipin antigen: nephelometric measurements. I. Acta Pathol Microbiol Scand. 1955; 36: 82-6.
    • (1955) Acta Pathol Microbiol Scand , vol.36 , pp. 82-86
    • Hartmann, J.1
  • 35
    • 0016287354 scopus 로고
    • Automated nephelometric immunoassay II. Its application to the determination of hapten
    • Cambiaso CL, Riccomi HA, Masson PL, Heremans JF Automated nephelometric immunoassay II. Its application to the determination of hapten. J Immunol Methods. 1974; 5: 293-302.
    • (1974) J Immunol Methods , vol.5 , pp. 293-302
    • Cambiaso, C.L.1    Riccomi, H.A.2    Masson, P.L.3    Heremans, J.F.4
  • 38
    • 0028207586 scopus 로고
    • Automated latex agglutination immunoassay of serum ferritin with a centrifugal analyzer
    • Simó JM, Joven J, Clivillé X, Sans T Automated latex agglutination immunoassay of serum ferritin with a centrifugal analyzer. Clin Chem. 1994; 40: 625-9.
    • (1994) Clin Chem , vol.40 , pp. 625-629
    • Simó, J.M.1    Joven, J.2    Clivillé, X.3    Sans, T.4
  • 39
    • 0015457944 scopus 로고
    • Radioimmunoassay of gastrin with activated charcoal
    • Schrumpf E, Sand T. Radioimmunoassay of gastrin with activated charcoal. Scand J Gastroenterol. 1972; 7: 683-7.
    • (1972) Scand J Gastroenterol , vol.7 , pp. 683-687
    • Schrumpf, E.1    Sand, T.2
  • 40
    • 0014244818 scopus 로고
    • Charcoal-dextran radioimmunoassay of human growth hormone
    • Wool MS, Selenkow HA Charcoal-dextran radioimmunoassay of human growth hormone. Acta Endocrinol (Copenh). 1968; 57: 109-14.
    • (1968) Acta Endocrinol (Copenh) , vol.57 , pp. 109-114
    • Wool, M.S.1    Selenkow, H.A.2
  • 41
    • 0018847736 scopus 로고
    • Luteinizing hormone-releasing hormone (LRH) extraction from peripheral plasma using bentonite and its measurement by radioimmunoassay during the menstrual cycle and in menopause
    • Malacara JM, Velasco E, García-Vela A. Luteinizing hormone-releasing hormone (LRH) extraction from peripheral plasma using bentonite and its measurement by radioimmunoassay during the menstrual cycle and in menopause. Rev Invest Clin. 1980; 32: 11-20.
    • (1980) Rev Invest Clin , vol.32 , pp. 11-20
    • Malacara, J.M.1    Velasco, E.2    García-Vela, A.3
  • 42
    • 0013881506 scopus 로고
    • Radioimmunoassay of human growth hormone using ion exchange resin
    • Lazarus L, Young JD. Radioimmunoassay of human growth hormone using ion exchange resin. J Clin Endocrinol Metab. 1966; 26: 213-8.
    • (1966) J Clin Endocrinol Metab , vol.26 , pp. 213-218
    • Lazarus, L.1    Young, J.D.2
  • 44
    • 0015906316 scopus 로고
    • New radioimmunoassay technique using second antibody to solid phase applied to assays of human chorionic somatomammotropin
    • Cocola F, Genazzani AR, Neri P. New radioimmunoassay technique using second antibody to solid phase applied to assays of human chorionic somatomammotropin. J Nucl Biol Med. 1973; 17: 14-21.
    • (1973) J Nucl Biol Med , vol.17 , pp. 14-21
    • Cocola, F.1    Genazzani, A.R.2    Neri, P.3
  • 45
    • 0015146643 scopus 로고
    • Use of polyethylene glycol to separate free and antibody-bound peptide hormones in radioimmunoassays
    • Desbuquois B, Aurbach GD. Use of polyethylene glycol to separate free and antibody-bound peptide hormones in radioimmunoassays. J Clin Endocrinol Metab. 1971; 33: 732-8.
    • (1971) J Clin Endocrinol Metab , vol.33 , pp. 732-738
    • Desbuquois, B.1    Aurbach, G.D.2
  • 46
    • 84950088560 scopus 로고
    • A rapid and specific method for separation of bound and free antigen in radioimmunoassay systems
    • Wood WG, Stalla G, Müller OA, Scriba PC. A rapid and specific method for separation of bound and free antigen in radioimmunoassay systems. J Clin Chem Clin Biochem. 1979; 17: 111-4.
    • (1979) J Clin Chem Clin Biochem , vol.17 , pp. 111-114
    • Wood, W.G.1    Stalla, G.2    Müller, O.A.3    Scriba, P.C.4
  • 47
    • 0015347498 scopus 로고
    • Radioimmunoassay of human growth hormone using ammonium sulphate [in Japanese]
    • Ogawa N, Takahara J, Ofuji T. Radioimmunoassay of human growth hormone using ammonium sulphate [in Japanese] Rinsho Byori. 1972; 20: 415-7.
    • (1972) Rinsho Byori , vol.20 , pp. 415-417
    • Ogawa, N.1    Takahara, J.2    Ofuji, T.3
  • 48
    • 0013944652 scopus 로고
    • Solid-phase radioimmunoassay of human growth hormone
    • Catt K, Niall HD, Tregear GW Solid-phase radioimmunoassay of human growth hormone. Biochem J. 1966; 100: 31-3.
    • (1966) Biochem J , vol.100 , pp. 31-33
    • Catt, K.1    Niall, H.D.2    Tregear, G.W.3
  • 49
    • 0014515415 scopus 로고
    • Antibody in polyacrylamide gel, a solid phase reagent for radioimmunoassay
    • Goodfriend T, Ball D, Updike S. Antibody in polyacrylamide gel, a solid phase reagent for radioimmunoassay. Immunochemistry. 1969; 6: 481-4.
    • (1969) Immunochemistry , vol.6 , pp. 481-484
    • Goodfriend, T.1    Ball, D.2    Updike, S.3
  • 50
    • 0016691672 scopus 로고
    • The specificity of a solid phase radioimmunoassay for human immunoglobulins
    • Eady RP, Chapple JC, Hough DW, Stevenson GT. The specificity of a solid phase radioimmunoassay for human immunoglobulins. J Immunol Methods. 1975; 7: 179-86.
    • (1975) J Immunol Methods , vol.7 , pp. 179-186
    • Eady, R.P.1    Chapple, J.C.2    Hough, D.W.3    Stevenson, G.T.4
  • 52
    • 0014954856 scopus 로고
    • Solid-phase radioimmunoassay of protein biosynthesis
    • Sox HC Jr, Mohit B. Solid-phase radioimmunoassay of protein biosynthesis. Science. 1970; 168: 1467-8.
    • (1970) Science , vol.168 , pp. 1467-1468
    • Sox Jr, H.C.1    Mohit, B.2
  • 54
    • 0018178753 scopus 로고
    • Automated measurement of serum thyroxine with the "ARIA II" as compared with competitive protein binding and radioimmunoassay
    • Reese MG, Johnson L. Automated measurement of serum thyroxine with the "ARIA II" as compared with competitive protein binding and radioimmunoassay. Clin Chem. 1978; 24: 342-4.
    • (1978) Clin Chem , vol.24 , pp. 342-344
    • Reese, M.G.1    Johnson, L.2
  • 56
    • 0018408147 scopus 로고
    • Horseradish peroxidase: A study of the kinetics and the determination of optimal reaction conditions, using hydrogen peroxide and 2,2′-azinobis 3-ethylbenzthiazoline-6-sulfonic acid (ABTS) as substrates
    • Gallati, VH. Horseradish peroxidase: a study of the kinetics and the determination of optimal reaction conditions, using hydrogen peroxide and 2,2′-azinobis 3-ethylbenzthiazoline-6-sulfonic acid (ABTS) as substrates. J Clin Chem Clin Biochem. 1979; 17: 1-7.
    • (1979) J Clin Chem Clin Biochem , vol.17 , pp. 1-7
    • Gallati, V.H.1
  • 57
    • 0030830524 scopus 로고    scopus 로고
    • Measurement of free triiodothyronine in intensive care patients-comparison of two routine methods
    • Vogeser M, Jacob K. Measurement of free triiodothyronine in intensive care patients-comparison of two routine methods. Eur J Clin Chem Clin Biochem. 1997; 35: 873-5.
    • (1997) Eur J Clin Chem Clin Biochem , vol.35 , pp. 873-875
    • Vogeser, M.1    Jacob, K.2
  • 58
    • 14244257013 scopus 로고    scopus 로고
    • Evaluation of a new automated electrochemiluminescent sex hormone-binding globulin (SHBG) immunoassay
    • Reynders M, Anckaert E, Schiettecatte J, Smitz J Evaluation of a new automated electrochemiluminescent sex hormone-binding globulin (SHBG) immunoassay. Clin Chem Lab Med. 2005; 43: 86-9.
    • (2005) Clin Chem Lab Med , vol.43 , pp. 86-89
    • Reynders, M.1    Anckaert, E.2    Schiettecatte, J.3    Smitz, J.4
  • 60
    • 0031712056 scopus 로고    scopus 로고
    • Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and Emit): A critical overview of performance characteristics and comparison with HPLC
    • Schütz E, Svinarov D, Shipkova M, Niedmann PD, Armstrong VW, Wieland E, Oellerich M. Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and Emit): a critical overview of performance characteristics and comparison with HPLC. Clin Chem. 1998; 44: 2158-64.
    • (1998) Clin Chem , vol.44 , pp. 2158-2164
    • Schütz, E.1    Svinarov, D.2    Shipkova, M.3    Niedmann, P.D.4    Armstrong, V.W.5    Wieland, E.6    Oellerich, M.7
  • 61
    • 0031261426 scopus 로고    scopus 로고
    • Product development: The making of the Abbott ARCHITECT
    • Kisner HJ. Product development: the making of the Abbott ARCHITECT. Clin Lab Manage Rev. 1997; 11: 419-21.
    • (1997) Clin Lab Manage Rev , vol.11 , pp. 419-421
    • Kisner, H.J.1
  • 63
    • 0028107839 scopus 로고
    • Analytical performance of Immulite assay of thyroid-stimulating hormone
    • Lamb EJ, Noonan KA, Burrin JM. Analytical performance of Immulite assay of thyroid-stimulating hormone. Clin Chem. 1994; 40: 1598-600.
    • (1994) Clin Chem , vol.40 , pp. 1598-1600
    • Lamb, E.J.1    Noonan, K.A.2    Burrin, J.M.3
  • 65
    • 33748128839 scopus 로고    scopus 로고
    • The new enzyme-linked immunosorbent digoxin assay on the ADVIA Integrated Modular System is virtually free from oleander interference
    • Dasgupta A, Kang E, Datta P. The new enzyme-linked immunosorbent digoxin assay on the ADVIA Integrated Modular System is virtually free from oleander interference. Ther Drug Monit. 2006; 28: 282-5.
    • (2006) Ther Drug Monit , vol.28 , pp. 282-285
    • Dasgupta, A.1    Kang, E.2    Datta, P.3
  • 67
    • 84961471710 scopus 로고
    • Comparison of the automated random access immunoassay analysers, ACS-180 (Ciba Coming) and AIA- 1200 (Tosoh)
    • Costongs GM, Janson PC. Comparison of the automated random access immunoassay analysers, ACS-180 (Ciba Coming) and AIA- 1200 (Tosoh). Eur J Clin Chem Clin Biochem. 1993; 31: 701-6.
    • (1993) Eur J Clin Chem Clin Biochem , vol.31 , pp. 701-706
    • Costongs, G.M.1    Janson, P.C.2
  • 69
    • 0032976340 scopus 로고    scopus 로고
    • Performance characteristics of the creatine kinase-MB mass assay on the Vitros ECi analyzer
    • Christenson RH, Demers LM, Goldsmith BM, Noel SA, Duh SH. Performance characteristics of the creatine kinase-MB mass assay on the Vitros ECi analyzer. Clin Biochem. 1999; 32: 237-40.
    • (1999) Clin Biochem , vol.32 , pp. 237-240
    • Christenson, R.H.1    Demers, L.M.2    Goldsmith, B.M.3    Noel, S.A.4    Duh, S.H.5
  • 72
    • 0033962302 scopus 로고    scopus 로고
    • Une nouvelle technique de dosage du 17β-estradiol sur le Kryptor® (Cis-Bio international): Utilisation au cours des cycles stimulés
    • Taïeb J, Sarnel C, Benattar C, Lindenbaum A. Une nouvelle technique de dosage du 17β-estradiol sur le Kryptor® (Cis-Bio international): utilisation au cours des cycles stimulés Ann Biol Clin (Paris). 2000; 58: 71-9.
    • (2000) Ann Biol Clin (Paris) , vol.58 , pp. 71-79
    • Taïeb, J.1    Sarnel, C.2    Benattar, C.3    Lindenbaum, A.4
  • 73
    • 33645011357 scopus 로고    scopus 로고
    • First trimester Down syndrome screening: Distribution of markers and comparison of assays for quantification of pregnancy-associated plasma protein-A
    • Wøjdemann KR, Larsen SO, Rode L, Shalmi A, Sundberg K, Christiansen M, Tabor A. First trimester Down syndrome screening: distribution of markers and comparison of assays for quantification of pregnancy-associated plasma protein-A. Scand J Clin Lab Invest. 2006; 66: 101-11.
    • (2006) Scand J Clin Lab Invest , vol.66 , pp. 101-111
    • Wøjdemann, K.R.1    Larsen, S.O.2    Rode, L.3    Shalmi, A.4    Sundberg, K.5    Christiansen, M.6    Tabor, A.7
  • 74
    • 3342962458 scopus 로고    scopus 로고
    • Circulating cytokines and chemokines in acute symptomatic parvovirus B19 infection: Negative association between levels of pro-inflammatory cytokines and development of B19-associated arthritis
    • Kerr JR, Cunniffe VS, Kelleher P, Coats AJ, Mattey DL. Circulating cytokines and chemokines in acute symptomatic parvovirus B19 infection: negative association between levels of pro-inflammatory cytokines and development of B19-associated arthritis. J Med Virol. 2004; 74: 147-55.
    • (2004) J Med Virol , vol.74 , pp. 147-155
    • Kerr, J.R.1    Cunniffe, V.S.2    Kelleher, P.3    Coats, A.J.4    Mattey, D.L.5
  • 75
    • 14844289526 scopus 로고    scopus 로고
    • Comparative evaluation of two enzyme linked immunosorbent assay methods and three Western Blot methods for the diagnosis of culture-confirmed early Lyme borreliosis in Italy
    • Marangoni A, Sparacino M, Mondardini V, Cavrini F, Storni E, Donati M, Cevenini R, Sambri V. Comparative evaluation of two enzyme linked immunosorbent assay methods and three Western Blot methods for the diagnosis of culture-confirmed early Lyme borreliosis in Italy. New Microbiol. 2005; 28: 37-43.
    • (2005) New Microbiol , vol.28 , pp. 37-43
    • Marangoni, A.1    Sparacino, M.2    Mondardini, V.3    Cavrini, F.4    Storni, E.5    Donati, M.6    Cevenini, R.7    Sambri, V.8
  • 78
    • 0030958882 scopus 로고    scopus 로고
    • Initial evaluation of cystatin C measurement by particle-enhanced immunonephelometry on the Behring nephehometer systems (BNA, BN II)
    • Finney H, Newman DJ, Gruber W, Merle P, Price CP. Initial evaluation of cystatin C measurement by particle-enhanced immunonephelometry on the Behring nephehometer systems (BNA, BN II). Clin Chem. 1997; 43: 1016-22.
    • (1997) Clin Chem , vol.43 , pp. 1016-1022
    • Finney, H.1    Newman, D.J.2    Gruber, W.3    Merle, P.4    Price, C.P.5
  • 79
    • 34848822293 scopus 로고    scopus 로고
    • An improved application for the enzyme multipled immunoassay technique for caffeine, amikacin, and methotrexate assays on the Dade-Behring Dimension RxL Max clinical chemistry system
    • Mendu DR, Chou PP, Soldin SJ. An improved application for the enzyme multipled immunoassay technique for caffeine, amikacin, and methotrexate assays on the Dade-Behring Dimension RxL Max clinical chemistry system. Ther Drug Monit. 2007; 29: 632-7.
    • (2007) Ther Drug Monit , vol.29 , pp. 632-637
    • Mendu, D.R.1    Chou, P.P.2    Soldin, S.J.3
  • 80
    • 1842581895 scopus 로고    scopus 로고
    • Analytical performance of the CEDIA cyclosporine PLUS whole blood immunoassay
    • Butch AW, Fukuchi AM. Analytical performance of the CEDIA cyclosporine PLUS whole blood immunoassay. J Anal Toxicol. 2004; 28: 204-10.
    • (2004) J Anal Toxicol , vol.28 , pp. 204-210
    • Butch, A.W.1    Fukuchi, A.M.2
  • 81
    • 0026629091 scopus 로고
    • Automated quantitative nephelometric latex immunoassay for determining ferritin in human serum
    • Borque L, Rus A, del Cura J, Maside C, Escanero J. Automated quantitative nephelometric latex immunoassay for determining ferritin in human serum. J Clin Lab Anal. 1992; 6: 239-44.
    • (1992) J Clin Lab Anal , vol.6 , pp. 239-244
    • Borque, L.1    Rus, A.2    del Cura, J.3    Maside, C.4    Escanero, J.5
  • 82
    • 0014398812 scopus 로고
    • Radioassays of non-antigenic hormones
    • Murphy BE. Radioassays of non-antigenic hormones. Trans Assoc Am Physicians. 1968; 81: 92-103.
    • (1968) Trans Assoc Am Physicians , vol.81 , pp. 92-103
    • Murphy, B.E.1
  • 83
    • 0014053958 scopus 로고
    • Regulation of the pituitary-thyroid axis in man: Relationship of TSH concentration to concentration of free and total thyroxine in plasma
    • Reichlin S, Utiger RD. Regulation of the pituitary-thyroid axis in man: relationship of TSH concentration to concentration of free and total thyroxine in plasma. J Clin Endocrinol Metab. 1967; 27: 251-5.
    • (1967) J Clin Endocrinol Metab , vol.27 , pp. 251-255
    • Reichlin, S.1    Utiger, R.D.2
  • 84
    • 0016639157 scopus 로고
    • In vitro testing of thyroid function: A review
    • Pain RW. In vitro testing of thyroid function: a review. Pathology. 1975; 7: 1-12.
    • (1975) Pathology , vol.7 , pp. 1-12
    • Pain, R.W.1
  • 85
    • 0017578045 scopus 로고
    • Radioimmunoassay of free thyroid hormone concentrations in the investigation of thyroid disease
    • Yeo PP, Lewis M, Evered DC. Radioimmunoassay of free thyroid hormone concentrations in the investigation of thyroid disease. Clin Endocrinol (Oxf). 1977; 6: 159-65.
    • (1977) Clin Endocrinol (Oxf) , vol.6 , pp. 159-165
    • Yeo, P.P.1    Lewis, M.2    Evered, D.C.3
  • 86
    • 1642487141 scopus 로고
    • Serum free thyroxine in pregnancy
    • Kurtz A, Dwyer K, Ekins R. Serum free thyroxine in pregnancy. Br Med J. 1979; 2(6189): 550-1.
    • (1979) Br Med J , vol.2 , Issue.6189 , pp. 550-551
    • Kurtz, A.1    Dwyer, K.2    Ekins, R.3
  • 88
    • 0014693061 scopus 로고
    • Determination of therapeutic and toxic serum digoxin concentrations by radioimmunoassay
    • Smith TW, Butler VP Jr, Haber E. Determination of therapeutic and toxic serum digoxin concentrations by radioimmunoassay. N Engl J Med. 1969; 281: 1212-6.
    • (1969) N Engl J Med , vol.281 , pp. 1212-1216
    • Smith, T.W.1    Butler Jr, V.P.2    Haber, E.3
  • 90
    • 0018256130 scopus 로고
    • A sensitive radioimmunoassay for 6-keto-prostaglandin F1alpha: Preliminary observations on circulating concentrations
    • Mitchell MD. A sensitive radioimmunoassay for 6-keto-prostaglandin F1alpha: preliminary observations on circulating concentrations. Prostaglandins Med. 1978; 1: 13-21.
    • (1978) Prostaglandins Med , vol.1 , pp. 13-21
    • Mitchell, M.D.1
  • 91
    • 0014775681 scopus 로고
    • Association of IgE with reaginic activity in sera from grass pollen- and horse dander-sensitive individuals
    • Frick OL, Ishizaka K. Association of IgE with reaginic activity in sera from grass pollen- and horse dander-sensitive individuals. J Allergy. 1970; 45: 220-33.
    • (1970) J Allergy , vol.45 , pp. 220-233
    • Frick, O.L.1    Ishizaka, K.2
  • 93
    • 0025937829 scopus 로고
    • Specific IgE to reindeer epithelium in Finnish reindeer herders
    • Reijula K, Halmepuro L, Hannuksela M, Larmi E, Hassi J. Specific IgE to reindeer epithelium in Finnish reindeer herders. Allergy. 1991; 46: 577-81.
    • (1991) Allergy , vol.46 , pp. 577-581
    • Reijula, K.1    Halmepuro, L.2    Hannuksela, M.3    Larmi, E.4    Hassi, J.5
  • 94
    • 0021971068 scopus 로고
    • Correlation of allergy test results obtained by IgE FAST, RAST, and prick-puncture methods
    • Seltzer JM, Halpern GM, Tsay YG. Correlation of allergy test results obtained by IgE FAST, RAST, and prick-puncture methods. Ann Allergy. 1985; 54: 25-30.
    • (1985) Ann Allergy , vol.54 , pp. 25-30
    • Seltzer, J.M.1    Halpern, G.M.2    Tsay, Y.G.3
  • 95
    • 0022515883 scopus 로고
    • Comparison of two assays for the determination of specific IgE in serum of atopic and nonatopic subjects: The Allergenetics FAST and the Phadezym RAST
    • Pécoud A, Peitrequin R, Fasel J, Frei PC. Comparison of two assays for the determination of specific IgE in serum of atopic and nonatopic subjects: the Allergenetics FAST and the Phadezym RAST. Allergy. 1986; 41: 243-9.
    • (1986) Allergy , vol.41 , pp. 243-249
    • Pécoud, A.1    Peitrequin, R.2    Fasel, J.3    Frei, P.C.4
  • 96
    • 0018076494 scopus 로고
    • Membranous ghomerulonephritis associated with anti-tubular and anti-alveolar basement membrane antibodies
    • Levy M, Gagnadoux MF, Beziau A, Habib R. Membranous ghomerulonephritis associated with anti-tubular and anti-alveolar basement membrane antibodies. Clin Nephrol. 1978; 10: 158-65.
    • (1978) Clin Nephrol , vol.10 , pp. 158-165
    • Levy, M.1    Gagnadoux, M.F.2    Beziau, A.3    Habib, R.4
  • 97
    • 0019907153 scopus 로고
    • Auto-antibodies in infectious mononucleosis, as determined by ELISA
    • Halbert SP, Anken M. Auto-antibodies in infectious mononucleosis, as determined by ELISA. Int Arch Allergy Appl Immunol. 1982;69 (3):257-61.
    • (1982) Int Arch Allergy Appl Immunol , vol.69 , Issue.3 , pp. 257-261
    • Halbert, S.P.1    Anken, M.2
  • 99
    • 0028365857 scopus 로고
    • Anti-thyroid peroxidase (anti-TPO) antibodies in thyroid diseases, non-thyroidal illness and controls. Clinical validity of a new commercial method for detection of anti-TPO (thyroid microsomal) autoantibodies
    • Engler H, Riesen WF, Keller B. Anti-thyroid peroxidase (anti-TPO) antibodies in thyroid diseases, non-thyroidal illness and controls. Clinical validity of a new commercial method for detection of anti-TPO (thyroid microsomal) autoantibodies. Clin Chim Acta. 1994; 225: 123-36.
    • (1994) Clin Chim Acta , vol.225 , pp. 123-136
    • Engler, H.1    Riesen, W.F.2    Keller, B.3
  • 100
    • 0022553796 scopus 로고
    • A multiple sample immunoblotting system (MSIS) for the intrinsic detection of antinuclear autoantibodies
    • Navarro E, Bach M, Durán N, Puigdomènech P, Palau J. A multiple sample immunoblotting system (MSIS) for the intrinsic detection of antinuclear autoantibodies. J Immunol Methods. 1986; 91: 75-81.
    • (1986) J Immunol Methods , vol.91 , pp. 75-81
    • Navarro, E.1    Bach, M.2    Durán, N.3    Puigdomènech, P.4    Palau, J.5
  • 101
    • 0017815354 scopus 로고
    • Rapid and sensitive radioimmunoassays for the c-terminal region of human parathyrin
    • Wood WG, Marschner I, Scriba PC. Rapid and sensitive radioimmunoassays for the c-terminal region of human parathyrin. Fresenius' Z Anal Chem 1978; 290: 170-1.
    • (1978) Fresenius' Z Anal Chem , vol.290 , pp. 170-171
    • Wood, W.G.1    Marschner, I.2    Scriba, P.C.3
  • 102
    • 0021328121 scopus 로고
    • Rapid radioimmunoassay for parathyroid hormone: Its use in hypercalcemic crisis
    • Mallette LE, Coscia AM. Rapid radioimmunoassay for parathyroid hormone: its use in hypercalcemic crisis. South Med J. 1984; 77: 323-6.
    • (1984) South Med J , vol.77 , pp. 323-326
    • Mallette, L.E.1    Coscia, A.M.2
  • 103
    • 0017861871 scopus 로고
    • Rapid, sensitive and reproducible assays for human parathyrin
    • Wood WG, Kuflicki G, Marschner I, Rapid, sensitive and reproducible assays for human parathyrin. Acta Endocrinol (Kbh) 1978; Suppl. 215: 116-7.
    • (1978) Acta Endocrinol (Kbh) , vol.215 , Issue.SUPPL. , pp. 116-117
    • Wood, W.G.1    Kuflicki, G.2    Marschner, I.3
  • 104
    • 0018764974 scopus 로고
    • Tests on three antisera and subsequent development of radioimmunoassay for different regions of human parathyrin
    • Wood WG, Marschner I, Scriba PC. Tests on three antisera and subsequent development of radioimmunoassay for different regions of human parathyrin. Horm Met Res. 1979; 11: 309-17.
    • (1979) Horm Met Res , vol.11 , pp. 309-317
    • Wood, W.G.1    Marschner, I.2    Scriba, P.C.3
  • 105
    • 0023186323 scopus 로고
    • Circulating intact parathyroid hormone measured by a two-site immunochemiluminometric assay
    • Brown RC, Aston JP, Weeks I, Woodhead JS. Circulating intact parathyroid hormone measured by a two-site immunochemiluminometric assay. J Clin Endocrinol Metab. 1987; 65: 407-14.
    • (1987) J Clin Endocrinol Metab , vol.65 , pp. 407-414
    • Brown, R.C.1    Aston, J.P.2    Weeks, I.3    Woodhead, J.S.4
  • 106
    • 33747763334 scopus 로고    scopus 로고
    • Quantification of recombinant human parathyroid hormone (rhPTH(1-84)) in human plasma by immunoassay: Commercial kit evaluation and validation to support pharmacokinetic studies
    • Epub Jun 9
    • Sukovaty RL, Lee JW, Fox J, Toney K, Papac DI, Grover TA, Wells DS. Quantification of recombinant human parathyroid hormone (rhPTH(1-84)) in human plasma by immunoassay: commercial kit evaluation and validation to support pharmacokinetic studies. J Pharm Biomed Anal. 2006; 42: 261-71. Epub 2006 Jun 9.
    • (2006) J Pharm Biomed Anal. 2006 , vol.42 , pp. 261-271
    • Sukovaty, R.L.1    Lee, J.W.2    Fox, J.3    Toney, K.4    Papac, D.I.5    Grover, T.A.6    Wells, D.S.7
  • 107
    • 60549097234 scopus 로고    scopus 로고
    • Roche Diagnostics News Release - FDA clearance for the 9-minute STAT parathyroid hormone test on the Elecsys 1010 and 2010 systems and cobas e 411 analyser. Indianapolis, 2007-04-23. www.roche-diagnostics.us/ press_room/2007/pr_70659.html
    • Roche Diagnostics News Release - FDA clearance for the 9-minute STAT parathyroid hormone test on the Elecsys 1010 and 2010 systems and cobas e 411 analyser. Indianapolis, 2007-04-23. www.roche-diagnostics.us/ press_room/2007/pr_70659.html
  • 109
    • 0022911199 scopus 로고
    • Two homologous radioimmunoassays for parathyrin compared and applied to disorders of calcium metabolism
    • Schmidt-Gayk H, Schmitt-Fiebig M, Hitzler W, Armbruster FP, Mayer E. Two homologous radioimmunoassays for parathyrin compared and applied to disorders of calcium metabolism. Clin Chem. 1986; 32: 57-62.
    • (1986) Clin Chem , vol.32 , pp. 57-62
    • Schmidt-Gayk, H.1    Schmitt-Fiebig, M.2    Hitzler, W.3    Armbruster, F.P.4    Mayer, E.5
  • 110
    • 0023479809 scopus 로고
    • Sensitive homologous radioimmunoassay for human parathyroid hormone to diagnose hypoparathyroid conditions
    • Zillikens D, Armbruster FP, Stern J, Schmidt-Gayk H, Raue F. Sensitive homologous radioimmunoassay for human parathyroid hormone to diagnose hypoparathyroid conditions. Ann Clin Biochem. 1987; 24: 608-13.
    • (1987) Ann Clin Biochem , vol.24 , pp. 608-613
    • Zillikens, D.1    Armbruster, F.P.2    Stern, J.3    Schmidt-Gayk, H.4    Raue, F.5
  • 112
    • 0018827448 scopus 로고
    • Interrelations of PTH, cAMP, creatinine and uric acid in nephrectomized patients under DNA or PTH application
    • Dunzendorfer U, Ohlenschläger G, Schmidt-Gayk H. Interrelations of PTH, cAMP, creatinine and uric acid in nephrectomized patients under DNA or PTH application. Urol Int. 1980; 35: 328-33.
    • (1980) Urol Int , vol.35 , pp. 328-333
    • Dunzendorfer, U.1    Ohlenschläger, G.2    Schmidt-Gayk, H.3
  • 113
    • 0023869406 scopus 로고
    • Enhanced suppression of 1,25(OH)2D3 and intact parathyroid hormone in Graves' disease as compared to toxic nodular goiter
    • Czernobilsky H, Scharla S, Schmidt-Gayk H, Ziegler R. Enhanced suppression of 1,25(OH)2D3 and intact parathyroid hormone in Graves' disease as compared to toxic nodular goiter. Calcif Tissue Int. 1988; 42: 5-12.
    • (1988) Calcif Tissue Int , vol.42 , pp. 5-12
    • Czernobilsky, H.1    Scharla, S.2    Schmidt-Gayk, H.3    Ziegler, R.4
  • 115
    • 0026656795 scopus 로고
    • Disturbed calcium metabolism in subjects with elevated diastolic blood pressure
    • Reichel H, Liebethal R, Hense HW, Schmidt-Gayk H, Ritz E. Disturbed calcium metabolism in subjects with elevated diastolic blood pressure. Clin Investig. 1992; 70: 748-51.
    • (1992) Clin Investig , vol.70 , pp. 748-751
    • Reichel, H.1    Liebethal, R.2    Hense, H.W.3    Schmidt-Gayk, H.4    Ritz, E.5
  • 117
    • 0030629647 scopus 로고    scopus 로고
    • Measurement of vitamin D and its metabolites (calcidiol and calcitriol) and their clinical significance
    • Schmidt-Gayk H, Bouillon R, Roth HJ. Measurement of vitamin D and its metabolites (calcidiol and calcitriol) and their clinical significance. Scand J Clin Lab Invest Suppl. 1997; 227: 35-45.
    • (1997) Scand J Clin Lab Invest Suppl , vol.227 , pp. 35-45
    • Schmidt-Gayk, H.1    Bouillon, R.2    Roth, H.J.3
  • 119
    • 0033623670 scopus 로고    scopus 로고
    • Circaannual rhythms and interactions of vitamin D metabolites, parathyroid hormone, and biochemical markers of skeletal homeostasis: A prospective study
    • Woitge HW, Knothe A, Witte K, Schmidt-Gayk H, Ziegler R, Lemmer B, Seibel MJ. Circaannual rhythms and interactions of vitamin D metabolites, parathyroid hormone, and biochemical markers of skeletal homeostasis: a prospective study. J Bone Miner Res. 2000; 15: 2443-50.
    • (2000) J Bone Miner Res , vol.15 , pp. 2443-2450
    • Woitge, H.W.1    Knothe, A.2    Witte, K.3    Schmidt-Gayk, H.4    Ziegler, R.5    Lemmer, B.6    Seibel, M.J.7
  • 120
    • 1642443472 scopus 로고    scopus 로고
    • Performance evaluation of automated assays for beta-CrossLaps, N-MID-Osteocalcin and intact parathyroid hormone (BIOROSE Multicenter Study)
    • Schmidt-Gayk H, Spanuth E, Kötting J, Bartl R, Felsenberg D, Pfeilschifter J, Raue F, Roth HJ. Performance evaluation of automated assays for beta-CrossLaps, N-MID-Osteocalcin and intact parathyroid hormone (BIOROSE Multicenter Study). Clin Chem Lab Med. 2004; 42: 90-5.
    • (2004) Clin Chem Lab Med , vol.42 , pp. 90-95
    • Schmidt-Gayk, H.1    Spanuth, E.2    Kötting, J.3    Bartl, R.4    Felsenberg, D.5    Pfeilschifter, J.6    Raue, F.7    Roth, H.J.8
  • 121
    • 11244278652 scopus 로고    scopus 로고
    • Evaluation of serum betacarboxy-terminal cross-linking telopeptide of type I collagen as marker of bone resorption in chronic hemodialysis patients
    • Reichel H, Roth HJ, Schmidt-Gayk H. Evaluation of serum betacarboxy-terminal cross-linking telopeptide of type I collagen as marker of bone resorption in chronic hemodialysis patients. Nephron Clin Pract. 2004; 98: c112-8.
    • (2004) Nephron Clin Pract , vol.98
    • Reichel, H.1    Roth, H.J.2    Schmidt-Gayk, H.3
  • 123
  • 124
    • 0028235157 scopus 로고
    • CYFRA 21-1, a sensitive and specific new tumour marker for squamous cell lung cancer. Report of the first European multicentre evaluation. CYFRA 21-1 Multicentre Study Group
    • Rastel D, Ramaioli A, Cornillie F, Thirion B. CYFRA 21-1, a sensitive and specific new tumour marker for squamous cell lung cancer. Report of the first European multicentre evaluation. CYFRA 21-1 Multicentre Study Group. Eur J Cancer. 1994; 30A: 601-6.
    • (1994) Eur J Cancer , vol.30 A , pp. 601-606
    • Rastel, D.1    Ramaioli, A.2    Cornillie, F.3    Thirion, B.4
  • 125
    • 0032732636 scopus 로고    scopus 로고
    • Human lymphocytes express hGH-N gene transcripts of 22kDa, 20kDa and minor forms of GH, but not hGH-V gene
    • Hattori N, Kitagawa K, Inagaki C Human lymphocytes express hGH-N gene transcripts of 22kDa, 20kDa and minor forms of GH, but not hGH-V gene. Eur J Endocrinol. 1999; 141: 413-8.
    • (1999) Eur J Endocrinol , vol.141 , pp. 413-418
    • Hattori, N.1    Kitagawa, K.2    Inagaki, C.3
  • 126
    • 0034136356 scopus 로고    scopus 로고
    • Detection of exogenous growth hormone (GH) administration by monitoring ratio of 20kDa- and 22kDa-GH in serum and urine
    • Momomura S, Hashimoto Y, Shimazaki Y, Irie M Detection of exogenous growth hormone (GH) administration by monitoring ratio of 20kDa- and 22kDa-GH in serum and urine. Endocr J. 2000; 47: 97-101.
    • (2000) Endocr J , vol.47 , pp. 97-101
    • Momomura, S.1    Hashimoto, Y.2    Shimazaki, Y.3    Irie, M.4
  • 128
    • 34250708359 scopus 로고    scopus 로고
    • Importance of CEA and CA 15-3 during disease progression in metastatic breast cancer patients
    • Laessig D, Nagel D, Heinemann V, Untch M, Kahlert S, Bauerfeind I, Stieber P. Importance of CEA and CA 15-3 during disease progression in metastatic breast cancer patients. Anticancer Res. 2007; 27(4A): 1963-8.
    • (2007) Anticancer Res , vol.27 , Issue.4 A , pp. 1963-1968
    • Laessig, D.1    Nagel, D.2    Heinemann, V.3    Untch, M.4    Kahlert, S.5    Bauerfeind, I.6    Stieber, P.7
  • 129
  • 130
    • 60549092529 scopus 로고    scopus 로고
    • Directive 98/79/EC of the European Parliament and of the Council of 27 October 1998 on in vitro diagnostic medical devices. Official Journal L 331, 7.12.1998, 1-40.
    • Directive 98/79/EC of the European Parliament and of the Council of 27 October 1998 on in vitro diagnostic medical devices. Official Journal L 331, 7.12.1998, 1-40.
  • 131
    • 60549117339 scopus 로고    scopus 로고
    • Inventory of External QA Programs for Clinical (Medical) Laboratories. World wide directory on the internet, website address: http://wwwn.cdc.gov/mlp/EQA_programs.aspx.
    • Inventory of External QA Programs for Clinical (Medical) Laboratories. World wide directory on the internet, website address: http://wwwn.cdc.gov/mlp/EQA_programs.aspx.
  • 132
    • 60549092327 scopus 로고    scopus 로고
    • Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen gemäß Beschluss des Vorstandes der Bundesärztekammer vom 23. November 2007. Deutsches Ärztebl. 2008; 105: A341-55
    • Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen gemäß Beschluss des Vorstandes der Bundesärztekammer vom 23. November 2007. Deutsches Ärztebl. 2008; 105: A341-55.
  • 133
    • 60549104605 scopus 로고    scopus 로고
    • UK-NEQAS, United Kingdom National External Quality Assessment Service
    • UK-NEQAS - United Kingdom National External Quality Assessment Service. Website: http://www.ukneqas.org.uk/content/Pageserver.asp.
    • Website
  • 135
    • 60549101532 scopus 로고    scopus 로고
    • QUALAB, Schweizerische Kommission für Qualitätssicherung im medizinischen Labor; Commission suisse pour l'assurance qualité dans le laboratoire médical; Commissione svizzera per l'assicurazione di qualità nel laboratorio medico; website
    • QUALAB - Schweizerische Kommission für Qualitätssicherung im medizinischen Labor; Commission suisse pour l'assurance qualité dans le laboratoire médical; Commissione svizzera per l'assicurazione di qualità nel laboratorio medico; website: http://www.qualab.ch/
  • 136
    • 60549086605 scopus 로고    scopus 로고
    • AFSSAPS, Agence Française de Sécurité SAnitaire des Produits de Santé website
    • AFSSAPS - Agence Française de Sécurité SAnitaire des Produits de Santé website: http://agmed.sante.gouv.fr/htm/ 10/cnq/indcnq.htm
  • 137
    • 0025727023 scopus 로고
    • Matrix effects in immunoassays
    • Wood, WG. "Matrix effects" in immunoassays. Scand J Clin Invest. 1991; 51: Suppl. 205, 105-12.
    • (1991) Scand J Clin Invest , vol.51 , Issue.SUPPL. 205 , pp. 105-112
    • Wood, W.G.1
  • 138
    • 0029670425 scopus 로고    scopus 로고
    • Accuracy-based assessment of proficiency testing results with serum from single donations: Possibilities and limitations
    • Stöckl D, Libeer JC, Reinauer H, Thienpont LM, De Leenheer AP. Accuracy-based assessment of proficiency testing results with serum from single donations: possibilities and limitations. Clin Chem. 1996; 42: 469-70.
    • (1996) Clin Chem , vol.42 , pp. 469-470
    • Stöckl, D.1    Libeer, J.C.2    Reinauer, H.3    Thienpont, L.M.4    De Leenheer, A.P.5
  • 139
    • 0038129689 scopus 로고    scopus 로고
    • Trueness verification in European external quality assessment schemes: Time to care about the quality of the samples
    • Thienpont LM, Stöckl D, Friedecký B, Kratochvíla J, Budina M. Trueness verification in European external quality assessment schemes: time to care about the quality of the samples. Scand J Clin Lab Invest. 2003; 63: 195-201.
    • (2003) Scand J Clin Lab Invest , vol.63 , pp. 195-201
    • Thienpont, L.M.1    Stöckl, D.2    Friedecký, B.3    Kratochvíla, J.4    Budina, M.5
  • 140
    • 34247524276 scopus 로고    scopus 로고
    • Sample commutability in external quality assessment surveys (EQAS) for thyroid-related antibodies-state of the art
    • Wood WG. Sample commutability in external quality assessment surveys (EQAS) for thyroid-related antibodies-state of the art. Clin Lab. 2007; 53: 217-22.
    • (2007) Clin Lab , vol.53 , pp. 217-222
    • Wood, W.G.1
  • 141
    • 3142568414 scopus 로고    scopus 로고
    • Rapid simultaneous quantification of immunosuppressants in transplant patients by turbulent flow chromatography combined with tandem mass spectrometry
    • Ceglarek U, Lembcke J, Fiedler GM, Werner M, Witzigmann H, Hauss JP, Thiery J. Rapid simultaneous quantification of immunosuppressants in transplant patients by turbulent flow chromatography combined with tandem mass spectrometry. Clin Chim Acta. 2004; 346: 181-90.
    • (2004) Clin Chim Acta , vol.346 , pp. 181-190
    • Ceglarek, U.1    Lembcke, J.2    Fiedler, G.M.3    Werner, M.4    Witzigmann, H.5    Hauss, J.P.6    Thiery, J.7
  • 142
    • 33747871781 scopus 로고    scopus 로고
    • Inclusion of MPA and in a rapid multi-drug LC-tandem mass spectrometric method for simultaneous determination of immunosuppressants
    • Epub May 17
    • Ceglarek U, Casetta B, Lembcke J, Baumann S, Fiedler GM, Thiery J. Inclusion of MPA and in a rapid multi-drug LC-tandem mass spectrometric method for simultaneous determination of immunosuppressants. Clin Chim Acta. 2006; 373: 168-71. Epub 2006 May 17.
    • (2006) Clin Chim Acta. 2006 , vol.373 , pp. 168-171
    • Ceglarek, U.1    Casetta, B.2    Lembcke, J.3    Baumann, S.4    Fiedler, G.M.5    Thiery, J.6
  • 143
    • 0035140321 scopus 로고    scopus 로고
    • A mass spectrometric method for quantitation of intact insulin in blood samples
    • Darby SM, Miller ML, Allen RO, LeBeau M. A mass spectrometric method for quantitation of intact insulin in blood samples. J Anal Toxicol. 2001; 25: 8-14.
    • (2001) J Anal Toxicol , vol.25 , pp. 8-14
    • Darby, S.M.1    Miller, M.L.2    Allen, R.O.3    LeBeau, M.4
  • 144
    • 33646347143 scopus 로고    scopus 로고
    • Sensitive quantitative analysis of C-peptide in human plasma by 2-dimensional liquid chromatography-mass spectrometry isotope-dilution assay
    • Epub Mar 23
    • Rogatsky E, Balent B, Goswami G, Tomuta V, Jayatillake H, Cruikshank G, Vele L, Stein DT. Sensitive quantitative analysis of C-peptide in human plasma by 2-dimensional liquid chromatography-mass spectrometry isotope-dilution assay. Clin Chem. 2006; 52: 872-9. Epub 2006 Mar 23.
    • (2006) Clin Chem. 2006 , vol.52 , pp. 872-879
    • Rogatsky, E.1    Balent, B.2    Goswami, G.3    Tomuta, V.4    Jayatillake, H.5    Cruikshank, G.6    Vele, L.7    Stein, D.T.8
  • 145
    • 0015593464 scopus 로고
    • The effects of sitosterol on serum cholesterol, platelet economy, thrombogenesis and atherosclerosis in the rabbit
    • Murphy EA, Rowsell HC, Mustard JF. The effects of sitosterol on serum cholesterol, platelet economy, thrombogenesis and atherosclerosis in the rabbit. Atherosclerosis. 1973; 17: 257-68.
    • (1973) Atherosclerosis , vol.17 , pp. 257-268
    • Murphy, E.A.1    Rowsell, H.C.2    Mustard, J.F.3
  • 147
    • 0032917446 scopus 로고    scopus 로고
    • Performance of a reagent strip device for quantitation of the urine albumin: Creatinine ratio in a point of care setting
    • Parsons M, Newman DJ, Pugia M, Newall RG, Price CP. Performance of a reagent strip device for quantitation of the urine albumin: creatinine ratio in a point of care setting. Clin Nephrol. 1999; 51: 220-7.
    • (1999) Clin Nephrol , vol.51 , pp. 220-227
    • Parsons, M.1    Newman, D.J.2    Pugia, M.3    Newall, R.G.4    Price, C.P.5
  • 148
    • 0037867008 scopus 로고    scopus 로고
    • An amplification-free hybridization-based DNA assay to detect Streptococcus pneumoniae utilizing the up-converting phosphor technology
    • Zuiderwijk M, Tanke HJ, Sam Niedbala R, Corstjens PL. An amplification-free hybridization-based DNA assay to detect Streptococcus pneumoniae utilizing the up-converting phosphor technology. Clin Biochem. 2003; 36: 401-3.
    • (2003) Clin Biochem , vol.36 , pp. 401-403
    • Zuiderwijk, M.1    Tanke, H.J.2    Sam Niedbala, R.3    Corstjens, P.L.4
  • 149
    • 0016586652 scopus 로고
    • Prototype for an implantable insulin delivery pump
    • Thomas LJ, Bessman SP. Prototype for an implantable insulin delivery pump. Proc West Pharmacol Soc. 1975; 18: 393-8.
    • (1975) Proc West Pharmacol Soc , vol.18 , pp. 393-398
    • Thomas, L.J.1    Bessman, S.P.2
  • 150
    • 0024514006 scopus 로고
    • In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method
    • Brückel J, Kerner W, Zier H, Steinbach G, Pfeiffer EF. In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method. Klin Wochenschr. 1989; 67: 491-5.
    • (1989) Klin Wochenschr , vol.67 , pp. 491-495
    • Brückel, J.1    Kerner, W.2    Zier, H.3    Steinbach, G.4    Pfeiffer, E.F.5
  • 151
    • 33748940470 scopus 로고    scopus 로고
    • Detection of creatinine enriched on a surface imprinted polystyrene film using FT-ATR-IR
    • Sep-Oct;
    • Sreenivasan K. Detection of creatinine enriched on a surface imprinted polystyrene film using FT-ATR-IR. J Mol Recognit. 2006 Sep-Oct;19(5):408-12
    • (2006) J Mol Recognit , vol.19 , Issue.5 , pp. 408-412
    • Sreenivasan, K.1
  • 152
    • 33846661912 scopus 로고    scopus 로고
    • Modulations in the intestinal disaccharide hydrolases and membrane dynamics: Effect of non-steroidal anti-inflammatory drugs aspirin and nimesulide
    • Epub Jul 20
    • Kaushal N, Sanyal SN. Modulations in the intestinal disaccharide hydrolases and membrane dynamics: effect of non-steroidal anti-inflammatory drugs aspirin and nimesulide. Mol Cell Biochem. 2007; 294: 107-15. Epub 2006 Jul 20
    • (2006) Mol Cell Biochem. 2007 , vol.294 , pp. 107-115
    • Kaushal, N.1    Sanyal, S.N.2
  • 154
    • 0031781727 scopus 로고    scopus 로고
    • Rapid identification of urinary tract infection bacteria using hyperspectral whole-organism finger-printing and artificial neural networks
    • Goodacre R, Timmins EM, Burton R, Kaderbhai N, Woodward AM, Kell DB, Rooney PJ. Rapid identification of urinary tract infection bacteria using hyperspectral whole-organism finger-printing and artificial neural networks. Microbiology. 1998; 144:1157-70.
    • (1998) Microbiology , vol.144 , pp. 1157-1170
    • Goodacre, R.1    Timmins, E.M.2    Burton, R.3    Kaderbhai, N.4    Woodward, A.M.5    Kell, D.B.6    Rooney, P.J.7
  • 155
    • 0031265246 scopus 로고    scopus 로고
    • Measurement of blood glucose concentration using infra-red spectroscopy]
    • Shichiri M, Nishida K, Uemura T. [Measurement of blood glucose concentration using infra-red spectroscopy] Nippon Rinsho. 1997; 55 Suppl: 895-9.
    • (1997) Nippon Rinsho , vol.55 , Issue.SUPPL. , pp. 895-899
    • Shichiri, M.1    Nishida, K.2    Uemura, T.3
  • 157
    • 0027262446 scopus 로고
    • Study of immunoglobulin G thin layers obtained by the Langmuir-Blodgett method: Application to immunosensors
    • Barraud A, Perrot H, Billard V, Martelet C, Therasse J. Study of immunoglobulin G thin layers obtained by the Langmuir-Blodgett method: application to immunosensors. Biosens Bio-electron. 1993; 8: 39-48.
    • (1993) Biosens Bio-electron , vol.8 , pp. 39-48
    • Barraud, A.1    Perrot, H.2    Billard, V.3    Martelet, C.4    Therasse, J.5
  • 158
    • 34250788815 scopus 로고    scopus 로고
    • Point-of-care testing, medical error, and patient safety: A 2007 assessment
    • Ehrmeyer SS, Laessig RH. Point-of-care testing, medical error, and patient safety: a 2007 assessment. Clin Chem Lab Med. 2007; 45: 766-73.
    • (2007) Clin Chem Lab Med , vol.45 , pp. 766-773
    • Ehrmeyer, S.S.1    Laessig, R.H.2
  • 159
    • 33750098540 scopus 로고    scopus 로고
    • Scalise D. Poised for growth. Point-of-care testing. Hosp Health Netw. 2006; 80: 77-83. (Erratum in: Hosp Health Netw. 2006; 80: 10).
    • Scalise D. Poised for growth. Point-of-care testing. Hosp Health Netw. 2006; 80: 77-83. (Erratum in: Hosp Health Netw. 2006; 80: 10).
  • 160
    • 0036067536 scopus 로고    scopus 로고
    • The future of home testing-implications for traditional laboratories
    • Lehmann CA. The future of home testing-implications for traditional laboratories. Clin Chim Acta. 2002; 323: 31-6.
    • (2002) Clin Chim Acta , vol.323 , pp. 31-36
    • Lehmann, C.A.1
  • 161
    • 85168046622 scopus 로고    scopus 로고
    • Bush DM. The U.S. Mandatory Guidelines for Federal Workplace Drug Testing Programs: current status and future considerations. Forensic Sci Int. 2008; 174: 111-9. Epub 2007 Apr 16.
    • Bush DM. The U.S. Mandatory Guidelines for Federal Workplace Drug Testing Programs: current status and future considerations. Forensic Sci Int. 2008; 174: 111-9. Epub 2007 Apr 16.
  • 162
    • 33847682623 scopus 로고    scopus 로고
    • Nichols JH, Christenson RH, Clarke W, Gronowski A, Hammett-Stabler CA, Jacobs E, Kazmierczak S, Lewandrowski K, Price C, Sacks DB, Sautter RL, Shipp G, Sokoll L, Watson ID, Winter W, Zucker ML; National Academy of Clinical Biochemistry. Executive summary. The National Academy of Clinical Biochemistry Laboratory Medicine Practice Guideline: evidence-based practice for point-of-care testing. Clin Chim Acta. 2007; 379: 14-28; discussion 29-30. Epub 2007 Jan 12. (Comment in: Clin Chim Acta. 2007; 381: 184-5; author reply 186-7).
    • Nichols JH, Christenson RH, Clarke W, Gronowski A, Hammett-Stabler CA, Jacobs E, Kazmierczak S, Lewandrowski K, Price C, Sacks DB, Sautter RL, Shipp G, Sokoll L, Watson ID, Winter W, Zucker ML; National Academy of Clinical Biochemistry. Executive summary. The National Academy of Clinical Biochemistry Laboratory Medicine Practice Guideline: evidence-based practice for point-of-care testing. Clin Chim Acta. 2007; 379: 14-28; discussion 29-30. Epub 2007 Jan 12. (Comment in: Clin Chim Acta. 2007; 381: 184-5; author reply 186-7).
  • 163
    • 33746624199 scopus 로고    scopus 로고
    • The impact of point of care testing on diabetes services along Victoria's Mallee Track: Results of a community-based diabetes risk assessment and management program
    • Epub Jul 15
    • Shephard MD, Mazzachi BC, Shephard AK, McLaughlin KJ, Denner B, Barnes G. The impact of point of care testing on diabetes services along Victoria's Mallee Track: results of a community-based diabetes risk assessment and management program. Rural Remote Health. 2005; 5: 371. Epub 2005 Jul 15.
    • (2005) Rural Remote Health. 2005 , vol.5 , pp. 371
    • Shephard, M.D.1    Mazzachi, B.C.2    Shephard, A.K.3    McLaughlin, K.J.4    Denner, B.5    Barnes, G.6
  • 164
    • 21844471002 scopus 로고    scopus 로고
    • Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
    • von Lode P. Point-of-care immunotesting: approaching the analytical performance of central laboratory methods. Clin Biochem. 2005; 38: 591-606.
    • (2005) Clin Biochem , vol.38 , pp. 591-606
    • von Lode, P.1
  • 166
    • 0036605186 scopus 로고    scopus 로고
    • Empowering patients with point-of-care testing
    • Bissell M, Sanfilippo F. Empowering patients with point-of-care testing. Trends Biotechnol. 2002; 20: 269-70.
    • (2002) Trends Biotechnol , vol.20 , pp. 269-270
    • Bissell, M.1    Sanfilippo, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.