메뉴 건너뛰기




Volumn 42, Issue 3, 1996, Pages 469-470

Accuracy-based assessment of proficiency testing results with serum from single donations: Possibilities and limitations

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLOOD CHEMISTRY; DIAGNOSTIC ACCURACY; LABORATORY TEST; TECHNIQUE;

EID: 0029670425     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/42.3.469     Document Type: Article
Times cited : (25)

References (6)
  • 2
    • 0027413476 scopus 로고
    • College of American Pathologists Conference XXIII. Matrix effects and accuracy assessment in clinical chemistry
    • Miller WG, Kaufman HW, McLendon WW, eds. College of American Pathologists Conference XXIII. Matrix effects and accuracy assessment in clinical chemistry. Arch Pathol Lab Med 1993;117:343-436.
    • (1993) Arch Pathol Lab Med , vol.117 , pp. 343-436
    • Miller, W.G.1    Kaufman, H.W.2    McLendon, W.W.3
  • 3
    • 0027263203 scopus 로고
    • Candidate reference methods for the determination of target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. I. Method setup
    • Stöckl D, Reinauer H. Candidate reference methods for the determination of target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. I. Method setup. Clin Chem 1993;39:993-1000.
    • (1993) Clin Chem , vol.39 , pp. 993-1000
    • Stöckl, D.1    Reinauer, H.2
  • 4
    • 0027309485 scopus 로고
    • Candidate reference methods for the determination of target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. II. Method transfer
    • Thienpont LM, De Leenheer AP, Stöckl D, Reinauer H. Candidate reference methods for the determination of target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. II. Method transfer. Clin Chem 1993;39:1001-6.
    • (1993) Clin Chem , vol.39 , pp. 1001-1006
    • Thienpont, L.M.1    De Leenheer, A.P.2    Stöckl, D.3    Reinauer, H.4
  • 5
    • 0028829445 scopus 로고
    • Three routine methods for serum cortisol evaluated by comparison with an isotope dilution gas chromatography-mass spectrometry method
    • De Brabandere VI. Thienpont LM, Stöckl D, De Leenheer AP. Three routine methods for serum cortisol evaluated by comparison with an isotope dilution gas chromatography-mass spectrometry method [Tech Brief]. Clin Chem 1995;41:1781-3.
    • (1995) Clin Chem , vol.41 , pp. 1781-1783
    • De Brabandere, V.I.1    Thienpont, L.M.2    Stöckl, D.3    De Leenheer, A.P.4
  • 6
    • 0029034406 scopus 로고
    • Candidate reference method for determining serum creatinine by isocratic HPLC: Validation with isotope dilution gas chromatography-mass spectrometry and application for accuracy assessment of routine test kits
    • Thienpont LM, Van Landuyt K, Stöckl D, De Leenheer AP. Candidate reference method for determining serum creatinine by isocratic HPLC: validation with isotope dilution gas chromatography-mass spectrometry and application for accuracy assessment of routine test kits. Clin Chem 1995;41:995-1003.
    • (1995) Clin Chem , vol.41 , pp. 995-1003
    • Thienpont, L.M.1    Van Landuyt, K.2    Stöckl, D.3    De Leenheer, A.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.