메뉴 건너뛰기




Volumn 14, Issue 2, 2009, Pages

In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems

Author keywords

Cortical bone; ISQ; Primary stability

Indexed keywords

ANIMAL TISSUE; ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; CORTICAL BONE; COW; DRILL; FREQUENCY ANALYSIS; IN VITRO STUDY; NONHUMAN; RIB; TOOTH IMPLANTATION;

EID: 59949083836     PISSN: 16984447     EISSN: 16986946     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (36)

References (27)
  • 1
    • 17844385046 scopus 로고    scopus 로고
    • Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures
    • Herrmann I, Lekholm U, Holm S, Kultje C. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int J Oral Maxillofac Implants. 2005;20:220-30.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 220-230
    • Herrmann, I.1    Lekholm, U.2    Holm, S.3    Kultje, C.4
  • 2
    • 0036547410 scopus 로고    scopus 로고
    • The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: Early results from clinical trials on ITI SLA implants
    • Cochran DL, Buser D, Ten Bruggenkate CM, Weingart D, Taylor TM, Bernard JP, et al. The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: early results from clinical trials on ITI SLA implants. Clin Oral Implants Res. 2002;13:144-53.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 144-153
    • Cochran, D.L.1    Buser, D.2    Ten Bruggenkate, C.M.3    Weingart, D.4    Taylor, T.M.5    Bernard, J.P.6
  • 3
    • 0019435541 scopus 로고
    • Osse-ointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osse-ointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155-70.
    • (1981) Acta Orthop Scand , vol.52 , pp. 155-170
    • Albrektsson, T.1    Brånemark, P.I.2    Hansson, H.A.3    Lindström, J.4
  • 5
    • 2942718771 scopus 로고    scopus 로고
    • Immediate implants after extraction. A review of the current situation
    • Peñarrocha M, Uribe R, Balaguer J. Immediate implants after extraction. A review of the current situation. Med Oral. 2004;9:234-42.
    • (2004) Med Oral , vol.9 , pp. 234-242
    • Peñarrocha, M.1    Uribe, R.2    Balaguer, J.3
  • 6
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11:491-501.
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 7
    • 0142088696 scopus 로고    scopus 로고
    • Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    • Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants. 2003;18:641-51.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 641-651
    • Barewal, R.M.1    Oates, T.W.2    Meredith, N.3    Cochran, D.L.4
  • 8
    • 0037491371 scopus 로고    scopus 로고
    • Primary stability and osseointegration: Preliminary clinical results with a tapered diminishing-thread implant
    • Abbou M. Primary stability and osseointegration: preliminary clinical results with a tapered diminishing-thread implant. Pract Proced Aesthet Dent. 2003;15:161-8.
    • (2003) Pract Proced Aesthet Dent , vol.15 , pp. 161-168
    • Abbou, M.1
  • 9
    • 0033629253 scopus 로고    scopus 로고
    • Influence of bicortical or monocortical anchorage on maxillary implant stability: A 15-year retrospective study of Brånemark System implants
    • Ivanoff CJ, Gröndahl K, Bergström C, Lekholm U, Brånemark PI. Influence of bicortical or monocortical anchorage on maxillary implant stability: a 15-year retrospective study of Brånemark System implants. Int J Oral Maxillofac Implants. 2000;15:103-10.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 103-110
    • Ivanoff, C.J.1    Gröndahl, K.2    Bergström, C.3    Lekholm, U.4    Brånemark, P.I.5
  • 11
    • 0035011470 scopus 로고    scopus 로고
    • Bone loading pattern around implants in average and atrophic edentulous maxillae: A finite-element analysis
    • Meyer U, Vollmer D, Runte C, Bourauel C, Joos U. Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis. J Craniomaxillofac Surg. 2001;29:100-5.
    • (2001) J Craniomaxillofac Surg , vol.29 , pp. 100-105
    • Meyer, U.1    Vollmer, D.2    Runte, C.3    Bourauel, C.4    Joos, U.5
  • 12
    • 0029377009 scopus 로고
    • Evaluation of bone density using cutting resistance measurements and microradiography: An in vitro study in pig ribs
    • Friberg B, Sennerby L, Roos J, Johansson P, Strid CG, Lekholm U. Evaluation of bone density using cutting resistance measurements and microradiography: an in vitro study in pig ribs. Clin Oral Implants Res. 1995;6:164-71.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 164-171
    • Friberg, B.1    Sennerby, L.2    Roos, J.3    Johansson, P.4    Strid, C.G.5    Lekholm, U.6
  • 13
    • 0029440426 scopus 로고
    • Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens
    • Friberg B, Sennerby L, Roos J, Lekholm U. Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens. Clin Oral Implants Res. 1995;6:213-9.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 213-219
    • Friberg, B.1    Sennerby, L.2    Roos, J.3    Lekholm, U.4
  • 14
    • 4644228515 scopus 로고    scopus 로고
    • Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants
    • O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res. 2004;15:474-80.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 474-480
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 15
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11:491-501.
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 16
    • 33645051957 scopus 로고    scopus 로고
    • Resonance frequency analysis and damping capacity assessment. Part 2: Peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments
    • Lachmann S, Laval JY, Jäger B, Axmann D, Gomez-Roman G, Groten M, et al. Resonance frequency analysis and damping capacity assessment. Part 2: peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments. Clin Oral Implants Res. 2006;17:80-4.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 80-84
    • Lachmann, S.1    Laval, J.Y.2    Jäger, B.3    Axmann, D.4    Gomez-Roman, G.5    Groten, M.6
  • 18
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996;7:261-7.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 19
    • 4644230057 scopus 로고    scopus 로고
    • Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants
    • Glauser R, Sennerby L, Meredith N, Rée A, Lundgren A, Gott- low J, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res. 2004;15:428-34.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 428-434
    • Glauser, R.1    Sennerby, L.2    Meredith, N.3    Rée, A.4    Lundgren, A.5    Gott- low, J.6
  • 20
    • 11844280921 scopus 로고    scopus 로고
    • Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6 months of loading
    • Sjöström M, Lundgren S, Nilson H, Sennerby L. Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6 months of loading. Int J Oral Maxillofac Surg. 2005;34:45-51.
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 45-51
    • Sjöström, M.1    Lundgren, S.2    Nilson, H.3    Sennerby, L.4
  • 22
    • 0036987398 scopus 로고    scopus 로고
    • Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study
    • Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study. Clin Implant Dent Relat Res. 2002;4:128-32.
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 128-132
    • Balleri, P.1    Cozzolino, A.2    Ghelli, L.3    Momicchioli, G.4    Varriale, A.5
  • 23
    • 23044454177 scopus 로고    scopus 로고
    • Resonance frequency analysis of one-stage dental implant stability during the osseointegration period
    • Ersanli S, Karabuda C, Beck F, Leblebicioglu B. Resonance frequency analysis of one-stage dental implant stability during the osseointegration period. J Periodontol. 2005;76:1066-71.
    • (2005) J Periodontol , vol.76 , pp. 1066-1071
    • Ersanli, S.1    Karabuda, C.2    Beck, F.3    Leblebicioglu, B.4
  • 24
    • 0033169238 scopus 로고    scopus 로고
    • Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study
    • Friberg B, Sennerby L, Linden B, Gröndahl K, Lekholm U. Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg. 1999;28:266-72.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 266-272
    • Friberg, B.1    Sennerby, L.2    Linden, B.3    Gröndahl, K.4    Lekholm, U.5
  • 25
    • 4644230057 scopus 로고    scopus 로고
    • Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants
    • Glauser R, Sennerby L, Meredith N, Rée A, Lundgren A, Gott-low J, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res. 2004;15:428-34.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 428-434
    • Glauser, R.1    Sennerby, L.2    Meredith, N.3    Rée, A.4    Lundgren, A.5    Gott-low, J.6
  • 26
    • 0025583331 scopus 로고
    • Divisions of available bone in implant dentistry
    • Misch CE. Divisions of available bone in implant dentistry. Int J Oral Implantol. 1990;7:9-17.
    • (1990) Int J Oral Implantol , vol.7 , pp. 9-17
    • Misch, C.E.1
  • 27
    • 33645084797 scopus 로고    scopus 로고
    • Resonance frequency analysis and damping capacity assessment. Part I: An in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability
    • Lachmann S, Jager B, Axmann D, Gomez-Roman G, Groten M, Weber H. Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res. 2006;17:75-9.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 75-79
    • Lachmann, S.1    Jager, B.2    Axmann, D.3    Gomez-Roman, G.4    Groten, M.5    Weber, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.