메뉴 건너뛰기




Volumn 11, Issue 3, 2006, Pages 178-181

Resonance frequency analysis after the placement of 133 dental implants;Estudio del análisis de frecuencia de resonancia tras la colocación de 133 implantes dentales

Author keywords

Dental implants; Implant stability quotient (ISQ); Insertion force (IF); Resonance frequency analysis (RFA)

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FREQUENCY ANALYSIS; HUMAN; MALE; MANDIBLE; MAXILLA; TOOTH IMPLANTATION;

EID: 33745059281     PISSN: 16984447     EISSN: 16986946     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (29)

References (9)
  • 1
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-7.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 2
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    • Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8:234-43.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 234-243
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 3
    • 0033169238 scopus 로고    scopus 로고
    • Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study
    • Friberg B, Sennerby L, Linden B, Grondahl K, Lekholm U. Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg 1999;28:266-72.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 266-272
    • Friberg, B.1    Sennerby, L.2    Linden, B.3    Grondahl, K.4    Lekholm, U.5
  • 5
    • 33745096144 scopus 로고    scopus 로고
    • A study on the change of implant stability using resonance frequency analysis
    • Chan-Jin Park, Yung-Soo Kim, Chang-Whe Kim, Lee-Ra Cho, Yang-Jin Yi. A study on the change of implant stability using resonance frequency analysis. J Korean Acad Prosthodont 2003;41:271-87.
    • (2003) J Korean Acad Prosthodont , vol.41 , pp. 271-287
    • Park, C.-J.1    Kim, Y.-S.2    Kim, C.-W.3    Cho, L.-R.4    Yi, Y.-J.5
  • 6
    • 0142027493 scopus 로고    scopus 로고
    • Resonance frequency análisis in inmediate loading of dental implants
    • Horwitz J, Zuabi O, Peled M. Resonance frequency análisis in inmediate loading of dental implants. Refuat Hapeh Vehashinayim 2003;20:80-8.
    • (2003) Refuat Hapeh Vehashinayim , vol.20 , pp. 80-88
    • Horwitz, J.1    Zuabi, O.2    Peled, M.3
  • 7
    • 0036987398 scopus 로고    scopus 로고
    • Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study
    • Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study. Clin Implant Dent Relat Res 2002;4:128-32.
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 128-132
    • Balleri, P.1    Cozzolino, A.2    Ghelli, L.3    Momicchioli, G.4    Varriale, A.5
  • 8
    • 0036481346 scopus 로고    scopus 로고
    • Resonance frequency assessment of dental implant stability with various bone qualities: A numerical approach
    • Huang HM, Lee SY, Yeh CY, Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Implants Res 2002;13:65-74.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 65-74
    • Huang, H.M.1    Lee, S.Y.2    Yeh, C.Y.3    Lin, C.T.4
  • 9
    • 0142088696 scopus 로고    scopus 로고
    • Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    • Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2003;18:641-51.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 641-651
    • Barewal, R.M.1    Oates, T.W.2    Meredith, N.3    Cochran, D.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.