-
1
-
-
4544327298
-
ACC/AHA guidelines for the management of patients with ST-elevation myocardial infarction: A report of the American College of Cardiology/ American Heart Association Task Force on Practice Guidelines (Committee to Revise the 1999 Guidelines for the Management of patients with acute myocardial infarction)
-
Antman EM, Anbe DT, Armstrong PW, et al: ACC/AHA guidelines for the management of patients with ST-elevation myocardial infarction: A report of the American College of Cardiology/ American Heart Association Task Force on Practice Guidelines (Committee to Revise the 1999 Guidelines for the Management of patients with acute myocardial infarction). J Am Coll Cardiol 44: E1-E211, 2004.
-
(2004)
J Am Coll Cardiol
, vol.44
-
-
Antman, E.M.1
Anbe, D.T.2
Armstrong, P.W.3
-
2
-
-
30344471501
-
Aortic counterpulsation: A review of the hemodynamic effects and indications for use
-
Santa-Cruz RA, Cohen MG, Ohman EM: Aortic counterpulsation: A review of the hemodynamic effects and indications for use. Cathet Cardiovasc Interv 67: 68-77, 2006.
-
(2006)
Cathet Cardiovasc Interv
, vol.67
, pp. 68-77
-
-
Santa-Cruz, R.A.1
Cohen, M.G.2
Ohman, E.M.3
-
3
-
-
0028061957
-
Intra-aortic balloon counterpulsation as a 'bridge' to cardiac transplantation. Effects in nonischemic and ischemic cardiomyopathy
-
Rosenbaum AM, Murali S, Uretsky BF: Intra-aortic balloon counterpulsation as a 'bridge' to cardiac transplantation. Effects in nonischemic and ischemic cardiomyopathy. Chest 106: 1683-1688, 1994.
-
(1994)
Chest
, vol.106
, pp. 1683-1688
-
-
Rosenbaum, A.M.1
Murali, S.2
Uretsky, B.F.3
-
4
-
-
0026757227
-
Ventricular assist devices for postcardiotomy cardiogenic shock: A combined registry experience
-
Pae WE Jr, Miller CA, Matthews Y, Pierce WS: Ventricular assist devices for postcardiotomy cardiogenic shock: A combined registry experience. J Thorac Cardiovasc Surg 104: 541-553, 1992.
-
(1992)
J Thorac Cardiovasc Surg
, vol.104
, pp. 541-553
-
-
Pae Jr, W.E.1
Miller, C.A.2
Matthews, Y.3
Pierce, W.S.4
-
5
-
-
0025728074
-
Left ventricular mechanics of ejecting, postischemic hearts during left ventricular circulatory assistance
-
Ratcliffe MB, Bavaria JE, Wenger RK, et al: Left ventricular mechanics of ejecting, postischemic hearts during left ventricular circulatory assistance. J Thorac Cardiovasc Surg 101: 245-255, 1991.
-
(1991)
J Thorac Cardiovasc Surg
, vol.101
, pp. 245-255
-
-
Ratcliffe, M.B.1
Bavaria, J.E.2
Wenger, R.K.3
-
6
-
-
19944431767
-
Comparison of pulsatile with nonpulsatile mechanical support in a porcine model of profound cardiogenic shock
-
Drakos SG, Charitos CE, Ntalianis A, et al: Comparison of pulsatile with nonpulsatile mechanical support in a porcine model of profound cardiogenic shock. ASAIO J 51: 26-29, 2005.
-
(2005)
ASAIO J
, vol.51
, pp. 26-29
-
-
Drakos, S.G.1
Charitos, C.E.2
Ntalianis, A.3
-
7
-
-
0030054590
-
Coronary microcirculation during left heart bypass with a centrifugal pump
-
Hata M, Shiono M, Orime Y, et al: Coronary microcirculation during left heart bypass with a centrifugal pump. Artif Organs 20: 678-680, 1996.
-
(1996)
Artif Organs
, vol.20
, pp. 678-680
-
-
Hata, M.1
Shiono, M.2
Orime, Y.3
-
8
-
-
0026590249
-
Mechanical support of the left ventricle in ischemia induced left ventricular failure: An experimental study
-
Zobel G, Dacar D, Kuttnig M, et al: Mechanical support of the left ventricle in ischemia induced left ventricular failure: an experimental study. Int J Artif Organs 15: 114-119, 1992.
-
(1992)
Int J Artif Organs
, vol.15
, pp. 114-119
-
-
Zobel, G.1
Dacar, D.2
Kuttnig, M.3
-
9
-
-
22544473208
-
Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock
-
Holger T, Sick P, Boudriot E, et al: Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock. Eur Heart J 26: 1276-1283, 2005.
-
(2005)
Eur Heart J
, vol.26
, pp. 1276-1283
-
-
Holger, T.1
Sick, P.2
Boudriot, E.3
-
10
-
-
33747178169
-
A randomized multicenter clinical study to evaluate the safety and efficacy of the Tandem Heart percutaneous ventricular assist device versus conventional therapy with intra-aortic balloon pumping for treatment of cardiogenic shock
-
Burkhoff D, Cohen H, Brunckhorst C, O'Neil W: A randomized multicenter clinical study to evaluate the safety and efficacy of the Tandem Heart percutaneous ventricular assist device versus conventional therapy with intra-aortic balloon pumping for treatment of cardiogenic shock. Am Heart J 152: 469 e1-e8, 2006.
-
(2006)
Am Heart J
, vol.152
, Issue.469
-
-
Burkhoff, D.1
Cohen, H.2
Brunckhorst, C.3
O'Neil, W.4
-
11
-
-
33747410890
-
Cardiac failure: Mechanical support strategies
-
Boehmer JP, Popjes E: Cardiac failure: Mechanical support strategies. Crit Care Med 34(suppl): S268-S277, 2006.
-
(2006)
Crit Care Med
, vol.34
, Issue.SUPPL.
-
-
Boehmer, J.P.1
Popjes, E.2
-
12
-
-
0026099801
-
Ventricular load optimization by unloading therapy in patients with heart failure
-
Kameyama T, Asanoi H, Ishizaka S, Sasayama S: Ventricular load optimization by unloading therapy in patients with heart failure. J Am Coll Cardiol 17: 199-207, 1991.
-
(1991)
J Am Coll Cardiol
, vol.17
, pp. 199-207
-
-
Kameyama, T.1
Asanoi, H.2
Ishizaka, S.3
Sasayama, S.4
-
13
-
-
0023212826
-
Early postoperative changes in left ventricular chamber size, architecture, and function in aortic stenosis and aortic regurgitation and their relation to intraoperative changes in afterload: A prospective two-dimensional echocardiographic study
-
Sutton M, Plappert T, Spiegel A, et al: Early postoperative changes in left ventricular chamber size, architecture, and function in aortic stenosis and aortic regurgitation and their relation to intraoperative changes in afterload: A prospective two-dimensional echocardiographic study. Circulation 76: 77-89, 1987.
-
(1987)
Circulation
, vol.76
, pp. 77-89
-
-
Sutton, M.1
Plappert, T.2
Spiegel, A.3
-
14
-
-
0037132601
-
-
Lamb H, Beyerbacht H, de Roos Albert, et al: Left ventricular remodelling early after aortic valve replacement: Differential effects on diastolic function in aortic valve stenosis and aortic regurgitation. J Am Coll Cardiol 40: 2182-2188, 2002.
-
Lamb H, Beyerbacht H, de Roos Albert, et al: Left ventricular remodelling early after aortic valve replacement: Differential effects on diastolic function in aortic valve stenosis and aortic regurgitation. J Am Coll Cardiol 40: 2182-2188, 2002.
-
-
-
-
15
-
-
0038674390
-
Aortic valve replacement for aortic regurgitation and stenosis, in patients with severe left ventricular dysfunction
-
Rothenburger M, Drebber K, Tjan T, et al: Aortic valve replacement for aortic regurgitation and stenosis, in patients with severe left ventricular dysfunction. Eur J Cardio Thorac Surg 23: 703-709, 2003.
-
(2003)
Eur J Cardio Thorac Surg
, vol.23
, pp. 703-709
-
-
Rothenburger, M.1
Drebber, K.2
Tjan, T.3
-
16
-
-
31044433499
-
Aortic valve replacement: A safe and durable option in patients with impaired left ventricular systolic function
-
Chukwuemeka A, Rao V, Armstrong S, et al: Aortic valve replacement: A safe and durable option in patients with impaired left ventricular systolic function. Eur J Cardio Thorac Surg 29: 133-138, 2006.
-
(2006)
Eur J Cardio Thorac Surg
, vol.29
, pp. 133-138
-
-
Chukwuemeka, A.1
Rao, V.2
Armstrong, S.3
-
17
-
-
0032918116
-
Ventriculoarterial coupling with intra-aortic balloon pump in acute isch-emic heart failure
-
Kawaguchi O, Pae WE, Daily BB, Pierce WS: Ventriculoarterial coupling with intra-aortic balloon pump in acute isch-emic heart failure. J Thorac Cardiovasc Surg 117: 164-171, 1999.
-
(1999)
J Thorac Cardiovasc Surg
, vol.117
, pp. 164-171
-
-
Kawaguchi, O.1
Pae, W.E.2
Daily, B.B.3
Pierce, W.S.4
-
18
-
-
0031759187
-
Aortic function in patients during intra-aortic balloon pumping determined by the pressure-diameter relation
-
Stefanadis C, Dernellis J, Tsiamis E, et al: Aortic function in patients during intra-aortic balloon pumping determined by the pressure-diameter relation. J Thorac Cardiovasc Surg 116: 1052-1059, 1998.
-
(1998)
J Thorac Cardiovasc Surg
, vol.116
, pp. 1052-1059
-
-
Stefanadis, C.1
Dernellis, J.2
Tsiamis, E.3
-
19
-
-
0031808568
-
Effective arterial elastance and the hemodynamic effects of intra-aortic balloon counterpulsation in patients with coronary heart disease
-
Marchionni N, Fumagalli S, Baldereschi G, et al: Effective arterial elastance and the hemodynamic effects of intra-aortic balloon counterpulsation in patients with coronary heart disease. Am Heart J 135: 855-861, 1998.
-
(1998)
Am Heart J
, vol.135
, pp. 855-861
-
-
Marchionni, N.1
Fumagalli, S.2
Baldereschi, G.3
-
20
-
-
0028844353
-
Effects of timing on ventriculoarterial coupling and mechanical efficiency during intra-aortic balloon pumping
-
Sakamoto T, Suzuki A, Kazama S, et al: Effects of timing on ventriculoarterial coupling and mechanical efficiency during intra-aortic balloon pumping. ASAIO J 41: M580-M583, 1995.
-
(1995)
ASAIO J
, vol.41
-
-
Sakamoto, T.1
Suzuki, A.2
Kazama, S.3
-
21
-
-
0030065979
-
Myocardial salvage by the use of reperfusion and intra-aortic balloon pump: Experimental study
-
Nanas JN, Nanas SN, Kontoyannis DA, et al: Myocardial salvage by the use of reperfusion and intra-aortic balloon pump: Experimental study. Ann Thorac Surg 61: 629-634, 1996.
-
(1996)
Ann Thorac Surg
, vol.61
, pp. 629-634
-
-
Nanas, J.N.1
Nanas, S.N.2
Kontoyannis, D.A.3
-
22
-
-
0014807141
-
Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption, and coronary blood flow in dogs
-
Powell WJ Jr, Daggett WM, Magro AE, et al: Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption, and coronary blood flow in dogs. Circ Res 26: 753-764, 1970.
-
(1970)
Circ Res
, vol.26
, pp. 753-764
-
-
Powell Jr, W.J.1
Daggett, W.M.2
Magro, A.E.3
-
23
-
-
0028222727
-
Counterpulsation: Historical background, technical improvements, hemodynamic and metabolic effects
-
Nanas JN, Moulopoulos SD: Counterpulsation: Historical background, technical improvements, hemodynamic and metabolic effects. Cardiology 84: 156-167, 1994.
-
(1994)
Cardiology
, vol.84
, pp. 156-167
-
-
Nanas, J.N.1
Moulopoulos, S.D.2
-
24
-
-
0028114532
-
Predictable reduction in left ventricular stroke work and oxygen utilization with an implantable centrifugal pump
-
Goldstein AH, Pacella JJ, Clark RE: Predictable reduction in left ventricular stroke work and oxygen utilization with an implantable centrifugal pump. Ann Thorac Surg 58: 1018-1024, 1994.
-
(1994)
Ann Thorac Surg
, vol.58
, pp. 1018-1024
-
-
Goldstein, A.H.1
Pacella, J.J.2
Clark, R.E.3
-
25
-
-
0018409025
-
Left ventricular mechanics of counterpulsation and left heart bypass, individually and in combination
-
Rose EA, Marrin CA, Bregman D, Spotnitz HM: Left ventricular mechanics of counterpulsation and left heart bypass, individually and in combination. J Thorac Cardiovasc Surg 77: 127-137, 1979.
-
(1979)
J Thorac Cardiovasc Surg
, vol.77
, pp. 127-137
-
-
Rose, E.A.1
Marrin, C.A.2
Bregman, D.3
Spotnitz, H.M.4
-
26
-
-
0024308122
-
Effect of cannulation site on the primary determinants of myocardial oxygen consumption during left heart bypass
-
Cohen DJ, Kress DC, Swanson DK, et al: Effect of cannulation site on the primary determinants of myocardial oxygen consumption during left heart bypass. J Surg Res 47: 159-165, 1989.
-
(1989)
J Surg Res
, vol.47
, pp. 159-165
-
-
Cohen, D.J.1
Kress, D.C.2
Swanson, D.K.3
-
27
-
-
0343485051
-
Influence of biopump with and without intra-aortic balloon on the coronary and carotid flow
-
Pego-Fernandes PM, Stolf NA, Moreira LF, et al: Influence of biopump with and without intra-aortic balloon on the coronary and carotid flow. Ann Thorac Surg 69: 536-540, 2000.
-
(2000)
Ann Thorac Surg
, vol.69
, pp. 536-540
-
-
Pego-Fernandes, P.M.1
Stolf, N.A.2
Moreira, L.F.3
-
28
-
-
0025130209
-
Effects of left ventricular assist for cardiogenic shock on cardiac function and organ blood flow distribution
-
Sukehiro S, Flameng W: Effects of left ventricular assist for cardiogenic shock on cardiac function and organ blood flow distribution. Ann Thorac Surg 50: 374-383, 1990.
-
(1990)
Ann Thorac Surg
, vol.50
, pp. 374-383
-
-
Sukehiro, S.1
Flameng, W.2
-
29
-
-
0031054117
-
High stroke volume para-aortic counterpulsation device versus centrifugal pump in cardiogenic shock: Experimental study
-
Nanas SN, Nanas JN, Charitos CE, et al: High stroke volume para-aortic counterpulsation device versus centrifugal pump in cardiogenic shock: Experimental study. World J Surg 21: 318-322, 1997.
-
(1997)
World J Surg
, vol.21
, pp. 318-322
-
-
Nanas, S.N.1
Nanas, J.N.2
Charitos, C.E.3
-
30
-
-
0025192070
-
Effect of circulatory assist devices on stunned myocardium
-
Bavaria JE, Furukawa S, Kreiner G, et al: Effect of circulatory assist devices on stunned myocardium. Ann Thorac Surg 49: 123-128, 1990.
-
(1990)
Ann Thorac Surg
, vol.49
, pp. 123-128
-
-
Bavaria, J.E.1
Furukawa, S.2
Kreiner, G.3
|