High stroke volume para-aortic counterpulsation device versus centrifugal pump in cardiogenic shock: Experimental study

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; ASCENDING AORTA; BLOOD PUMP; CARDIOGENIC SHOCK; CONTROLLED STUDY; DEVICE; DOG; HEART INDEX; HEART LEFT VENTRICLE FAILURE; HEART STROKE VOLUME; HEART TRANSPLANTATION; HEART VENTRICLE ENDDIASTOLIC PRESSURE; MEAN ARTERIAL PRESSURE; NONHUMAN;

EID: 0031054117     PISSN: 03642313     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002689900236     Document Type: Article
Times cited : (2)

References (20)
  • 6
    • 0024547613 scopus 로고
    • Use of a left ventricular assist device as a bridge to transplantation in a pediatric patient
    • Frazier, O.H., Bricker, J.T., Macris, M.P., Cooley, D.A.: Use of a left ventricular assist device as a bridge to transplantation in a pediatric patient. Tex. Heart Inst. J. 16:46, 1989
    • (1989) Tex. Heart Inst. J. , vol.16 , pp. 46
    • Frazier, O.H.1    Bricker, J.T.2    Macris, M.P.3    Cooley, D.A.4
  • 11
    • 0024341274 scopus 로고
    • The Pierce-Donachy ventricular assist device as a bridge to cardiac transplantation
    • Gray, L.A., Jr., Ganzel, B.L., Mavroudis, C., Slater, A.D.: The Pierce-Donachy ventricular assist device as a bridge to cardiac transplantation. Ann. Thorac. Surg. 48:222, 1989
    • (1989) Ann. Thorac. Surg. , vol.48 , pp. 222
    • Gray Jr., L.A.1    Ganzel, B.L.2    Mavroudis, C.3    Slater, A.D.4
  • 15
    • 0022596454 scopus 로고
    • Comparison of an implanted abdominal aortic counterpulsation device with the intraaortic balloon pump in a heart failure model
    • Nanas, J.N., Mason, J.W., Taenaka, Y., Olsen, D.B.: Comparison of an implanted abdominal aortic counterpulsation device with the intraaortic balloon pump in a heart failure model. J. Am. Coll. Cardiol. 7:1028, 1986
    • (1986) J. Am. Coll. Cardiol. , vol.7 , pp. 1028
    • Nanas, J.N.1    Mason, J.W.2    Taenaka, Y.3    Olsen, D.B.4
  • 17
    • 0030022664 scopus 로고    scopus 로고
    • A valveless high stroke volume counterpulsation device restores hemodynamics in patients with congestive heart failure and intractable cardiogenic shock awaiting heart transplantation
    • Nanas, J.N., Lolas, L., Charitos, C., Nanas, S.N., Margari, Z.J., Agapetos, E., Moulopoulos, S.D.: A valveless high stroke volume counterpulsation device restores hemodynamics in patients with congestive heart failure and intractable cardiogenic shock awaiting heart transplantation. J. Thorac. Cardiovasc. Surg. 111:55, 1996
    • (1996) J. Thorac. Cardiovasc. Surg. , vol.111 , pp. 55
    • Nanas, J.N.1    Lolas, L.2    Charitos, C.3    Nanas, S.N.4    Margari, Z.J.5    Agapetos, E.6    Moulopoulos, S.D.7
  • 19
    • 0000771344 scopus 로고
    • Hemodynamic determinants of oxygen consumption of the heart with a special reference to the tension time index
    • Sarnoff, S.J., Braunwald, E., Welch, G.H.: Hemodynamic determinants of oxygen consumption of the heart with a special reference to the tension time index. Am. J. Physiol. 192:148, 1958
    • (1958) Am. J. Physiol. , vol.192 , pp. 148
    • Sarnoff, S.J.1    Braunwald, E.2    Welch, G.H.3
  • 20
    • 0016438136 scopus 로고
    • A clinical method for detecting subendocardial ischemia following cardiopulmonary bypass
    • Philips, P.A., Marty, A.T., Miyaamoto, A.M.: A clinical method for detecting subendocardial ischemia following cardiopulmonary bypass. J. Thorac. Cardiovasc. Surg. 69:30, 1975
    • (1975) J. Thorac. Cardiovasc. Surg. , vol.69 , pp. 30
    • Philips, P.A.1    Marty, A.T.2    Miyaamoto, A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.