1
-
-
17144374110
-
Determining the optimal obturation length: a meta-analysis of literature
-
Schaeffer M.A., White R.R., and Walton R.E. Determining the optimal obturation length: a meta-analysis of literature. J Endod 31 (2005) 271-274
-
(2005)
J Endod
, vol.31
, pp. 271-274
-
-
Schaeffer, M.A.1
White, R.R.2
Walton, R.E.3
-
2
-
-
0000324382
-
Apical limit of root canal instrumentation and obturation. Part 2. A histological study
-
Ricucci D., and Langeland K. Apical limit of root canal instrumentation and obturation. Part 2. A histological study. Int Endod J 31 (1998) 394-409
-
(1998)
Int Endod J
, vol.31
, pp. 394-409
-
-
Ricucci, D.1
Langeland, K.2
-
4
-
-
0037607470
-
The cemento-dentino-canal junction, the apical foramen, and the apical constriction: evaluation by optical microscopy
-
Ponce E.H., and Fernandez J.A.V. The cemento-dentino-canal junction, the apical foramen, and the apical constriction: evaluation by optical microscopy. J Endod 29 (2003) 214-219
-
(2003)
J Endod
, vol.29
, pp. 214-219
-
-
Ponce, E.H.1
Fernandez, J.A.V.2
-
5
-
-
77049220185
-
Microscopic investigation of root apexes
-
Kuttler Y. Microscopic investigation of root apexes. J Am Dent Assoc 50 (1955) 544-552
-
(1955)
J Am Dent Assoc
, vol.50
, pp. 544-552
-
-
Kuttler, Y.1
-
6
-
-
0036483617
-
Influence of the canal contents on the electrical assisted determination of the length of root canals
-
Pommer O., Stamm O., and Attin T. Influence of the canal contents on the electrical assisted determination of the length of root canals. J Endod 28 (2002) 83-85
-
(2002)
J Endod
, vol.28
, pp. 83-85
-
-
Pommer, O.1
Stamm, O.2
Attin, T.3
-
7
-
-
84886609551
-
New method for measuring the length of the root canal
-
Sunada I. New method for measuring the length of the root canal. J Dent Res 41 (1962) 375-387
-
(1962)
J Dent Res
, vol.41
, pp. 375-387
-
-
Sunada, I.1
-
9
-
-
0028402339
-
New electronic canal measuring device based on the ratio method
-
Kobayashi C., and Suda H. New electronic canal measuring device based on the ratio method. J Endod 20 (1994) 111-114
-
(1994)
J Endod
, vol.20
, pp. 111-114
-
-
Kobayashi, C.1
Suda, H.2
-
10
-
-
33745809484
-
The fundamental operating principles of electronic root canal length measurement devices
-
Nekoofar M.H., Ghandi M.M., Hayes S.J., and Dummer P.M. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J 39 (2006) 595-609
-
(2006)
Int Endod J
, vol.39
, pp. 595-609
-
-
Nekoofar, M.H.1
Ghandi, M.M.2
Hayes, S.J.3
Dummer, P.M.4
-
11
-
-
33645096500
-
A simple mounting model for consistent determination of the accuracy and repeatability of apex locators
-
El Ayouti A., and Löst C. A simple mounting model for consistent determination of the accuracy and repeatability of apex locators. Int Endod J 39 (2006) 108-112
-
(2006)
Int Endod J
, vol.39
, pp. 108-112
-
-
El Ayouti, A.1
Löst, C.2
-
12
-
-
0029286032
-
An in vivo evaluation of the ENDEX and RCM Mark II electronic apex locators in root canals with different contents
-
Arora R.K., and Gulabivala K. An in vivo evaluation of the ENDEX and RCM Mark II electronic apex locators in root canals with different contents. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 79 (1995) 497-503
-
(1995)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.79
, pp. 497-503
-
-
Arora, R.K.1
Gulabivala, K.2
-
13
-
-
0031297421
-
Determination of impedance changes at varying frequencies in relation to root canal file position and irrigant
-
Pilot T.F., and Pitts D.L. Determination of impedance changes at varying frequencies in relation to root canal file position and irrigant. J Endod 23 (1997) 719-724
-
(1997)
J Endod
, vol.23
, pp. 719-724
-
-
Pilot, T.F.1
Pitts, D.L.2
-
14
-
-
34548522474
-
Ledge formation: review of a great challenge in endodontics
-
Jafarzadeh H., and Abbott P.V. Ledge formation: review of a great challenge in endodontics. J Endod 33 (2007) 1155-1162
-
(2007)
J Endod
, vol.33
, pp. 1155-1162
-
-
Jafarzadeh, H.1
Abbott, P.V.2
-
15
-
-
4043150654
-
In vitro analysis of 'smear layer' on human dentine using ac-impedance spectroscopy
-
Eldarrat A.H., High A.S., and Kale G.M. In vitro analysis of 'smear layer' on human dentine using ac-impedance spectroscopy. J Dent 32 (2004) 547-554
-
(2004)
J Dent
, vol.32
, pp. 547-554
-
-
Eldarrat, A.H.1
High, A.S.2
Kale, G.M.3
-
16
-
-
0033181886
-
Effect of preflaring on Root ZX apex locators
-
Ibarrola J.L., Chapman B.L., Howard J.H., Knowles K.I., and Ludlow M.O. Effect of preflaring on Root ZX apex locators. J Endod 25 (1999) 625-626
-
(1999)
J Endod
, vol.25
, pp. 625-626
-
-
Ibarrola, J.L.1
Chapman, B.L.2
Howard, J.H.3
Knowles, K.I.4
Ludlow, M.O.5
-
17
-
-
0020994545
-
A model for demonstrating an electronic canal-length measuring device
-
Aurelio J.A., Nahmias Y., and Gerstein H. A model for demonstrating an electronic canal-length measuring device. J Endod 9 (1983) 568-569
-
(1983)
J Endod
, vol.9
, pp. 568-569
-
-
Aurelio, J.A.1
Nahmias, Y.2
Gerstein, H.3
-
18
-
-
27644542251
-
Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study
-
El Ayouti A., Kimionis I., Chu A.L., and Lost C. Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study. Int Endod J 38 (2005) 827-833
-
(2005)
Int Endod J
, vol.38
, pp. 827-833
-
-
El Ayouti, A.1
Kimionis, I.2
Chu, A.L.3
Lost, C.4
-
19
-
-
33645103350
-
Evaluation of the accuracy of three electronic apex locators using glass tubules
-
Fan W., Fan B., Gutmann J.L., Bian Z., and Fan M.W. Evaluation of the accuracy of three electronic apex locators using glass tubules. Int Endod J 39 (2006) 127-135
-
(2006)
Int Endod J
, vol.39
, pp. 127-135
-
-
Fan, W.1
Fan, B.2
Gutmann, J.L.3
Bian, Z.4
Fan, M.W.5
-
20
-
-
0028724947
-
An in vitro test of a simplified model to demonstrate the operation of electronic root canal measuring devices
-
Czerw R., Fulkerson M.S., and Donnelly J.C. An in vitro test of a simplified model to demonstrate the operation of electronic root canal measuring devices. J Endod 20 (1994) 605-606
-
(1994)
J Endod
, vol.20
, pp. 605-606
-
-
Czerw, R.1
Fulkerson, M.S.2
Donnelly, J.C.3
-
21
-
-
34447564209
-
Influence of apical constriction diameter on Root ZX apex locator precision
-
Herrera M., Abalos C., Planas A.J., and Llamas R. Influence of apical constriction diameter on Root ZX apex locator precision. J Endod 33 (2007) 995-998
-
(2007)
J Endod
, vol.33
, pp. 995-998
-
-
Herrera, M.1
Abalos, C.2
Planas, A.J.3
Llamas, R.4
-
22
-
-
0027548645
-
Accuracy of the Endex with variations in canal irrigants and foramen size
-
Fouad A.F., Rivera E.M., and Krell K.V. Accuracy of the Endex with variations in canal irrigants and foramen size. J Endod 19 (1993) 63-67
-
(1993)
J Endod
, vol.19
, pp. 63-67
-
-
Fouad, A.F.1
Rivera, E.M.2
Krell, K.V.3
-
23
-
-
0036675072
-
The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator
-
Meares W.A., and Steiman H.R. The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator. J Endod 28 (2002) 595-598
-
(2002)
J Endod
, vol.28
, pp. 595-598
-
-
Meares, W.A.1
Steiman, H.R.2
-
24
-
-
0036515292
-
The effects of sodium hypochlorite concentrations on the accuracy of an apex locating device
-
Tinaz A.C., Sevimli L.S., Görgül G., and Türköz E.G. The effects of sodium hypochlorite concentrations on the accuracy of an apex locating device. J Endod 28 (2002) 160-162
-
(2002)
J Endod
, vol.28
, pp. 160-162
-
-
Tinaz, A.C.1
Sevimli, L.S.2
Görgül, G.3
Türköz, E.G.4
-
25
-
-
0034231421
-
An overview of nickel-titanium alloys used in dentistry
-
Thompson S.A. An overview of nickel-titanium alloys used in dentistry. Int Endod J 33 (2000) 297-310
-
(2000)
Int Endod J
, vol.33
, pp. 297-310
-
-
Thompson, S.A.1
-
27
-
-
1542570492
-
The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files
-
Thomas A.S., Hartwell G.R., and Moon P.C. The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files. J Endod 29 (2003) 662-663
-
(2003)
J Endod
, vol.29
, pp. 662-663
-
-
Thomas, A.S.1
Hartwell, G.R.2
Moon, P.C.3
-
28
-
-
36248997689
-
Apical accuracy of two apex-locating handpieces in root canal retreatments of root-end resected teeth
-
Uzun O., Topuz O., Tinaz A.C., and Alaçam T. Apical accuracy of two apex-locating handpieces in root canal retreatments of root-end resected teeth. J Endod 33 (2007) 1444-1446
-
(2007)
J Endod
, vol.33
, pp. 1444-1446
-
-
Uzun, O.1
Topuz, O.2
Tinaz, A.C.3
Alaçam, T.4
-
29
-
-
33644589221
-
Accuracy of root length determination using Tri Auto ZX and ProTaper instruments: an in vitro study
-
Carneiro E., Bramante C.M., Picoli F., Letra A., da Silva Neto U.X., and Menezes R. Accuracy of root length determination using Tri Auto ZX and ProTaper instruments: an in vitro study. J Endod 32 (2006) 142-144
-
(2006)
J Endod
, vol.32
, pp. 142-144
-
-
Carneiro, E.1
Bramante, C.M.2
Picoli, F.3
Letra, A.4
da Silva Neto, U.X.5
Menezes, R.6
-
30
-
-
3242771371
-
Electronic apex locator
-
Kim E., and Lee S.J. Electronic apex locator. Dent Clin N Am 48; (2004) 35-54
-
(2004)
Dent Clin N Am
, vol.48
, pp. 35-54
-
-
Kim, E.1
Lee, S.J.2
-
31
-
-
4143097917
-
Current challenges and concepts in the preparation of root canal systems: a review
-
Peters O.A. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 30 (2004) 559-567
-
(2004)
J Endod
, vol.30
, pp. 559-567
-
-
Peters, O.A.1
-
33
-
-
0036651349
-
In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex-locating handpiece
-
Grimberg F., Banegas G., Chiacchio L., and Zmener O. In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex-locating handpiece. Int Endod J 35 (2002) 590-593
-
(2002)
Int Endod J
, vol.35
, pp. 590-593
-
-
Grimberg, F.1
Banegas, G.2
Chiacchio, L.3
Zmener, O.4
-
34
-
-
1942500340
-
Modeling AC current conduction through a human tooth
-
Krizaj D., Jan J., and Valencic V. Modeling AC current conduction through a human tooth. Bioelectromagnetics 25 (2004) 185-195
-
(2004)
Bioelectromagnetics
, vol.25
, pp. 185-195
-
-
Krizaj, D.1
Jan, J.2
Valencic, V.3
|