메뉴 건너뛰기




Volumn 33, Issue 12, 2007, Pages 1444-1446

Apical Accuracy of Two Apex-locating Handpieces in Root Canal Retreatments of Root-end Resected Teeth

Author keywords

Apex locator; retreatment; TCM Endo V; Tri Auto ZX

Indexed keywords

ARTICLE; DENTAL EQUIPMENT; ENDODONTICS; HISTOLOGY; HUMAN; INCISOR; INSTRUMENTATION; ODONTOMETRY; REPRODUCIBILITY; RETREATMENT; TOOTH ROOT;

EID: 36248997689     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2007.07.033     Document Type: Article
Times cited : (13)

References (22)
  • 1
    • 27644542251 scopus 로고    scopus 로고
    • Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study
    • ElAyouti A., Kimionis I., Chu A.L., and Löst C. Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study. Int Endod J 38 (2005) 827-833
    • (2005) Int Endod J , vol.38 , pp. 827-833
    • ElAyouti, A.1    Kimionis, I.2    Chu, A.L.3    Löst, C.4
  • 3
    • 3042613238 scopus 로고    scopus 로고
    • The influence of root-end resection and root-end cavity preparation on microleakage of root filled teeth in vitro
    • Kontakiotis E.G., Lagoudakos T.A., and Georgopoulou M.K. The influence of root-end resection and root-end cavity preparation on microleakage of root filled teeth in vitro. Int Endod J 37 (2004) 403-407
    • (2004) Int Endod J , vol.37 , pp. 403-407
    • Kontakiotis, E.G.1    Lagoudakos, T.A.2    Georgopoulou, M.K.3
  • 4
    • 0036480113 scopus 로고    scopus 로고
    • The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length
    • ElAyouti A., Weiger R., and Löst C. The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length. J Endod 28 (2002) 116-119
    • (2002) J Endod , vol.28 , pp. 116-119
    • ElAyouti, A.1    Weiger, R.2    Löst, C.3
  • 5
    • 33745809484 scopus 로고    scopus 로고
    • The fundamental operating principles of electronic root canal length measurement devices
    • Nekoofar M.H., Ghandi M.M., Hayes S.J., and Dummer P.M. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J 39 (2006) 595-609
    • (2006) Int Endod J , vol.39 , pp. 595-609
    • Nekoofar, M.H.1    Ghandi, M.M.2    Hayes, S.J.3    Dummer, P.M.4
  • 6
    • 0036651349 scopus 로고    scopus 로고
    • In vivo determination of root canal length: a preliminary report using the Tri Auto-ZX apex-locating handpiece
    • Grimberg F., Banegas G., Chiacchio L., and Zmener O. In vivo determination of root canal length: a preliminary report using the Tri Auto-ZX apex-locating handpiece. Int Endod J 35 (2002) 590-593
    • (2002) Int Endod J , vol.35 , pp. 590-593
    • Grimberg, F.1    Banegas, G.2    Chiacchio, L.3    Zmener, O.4
  • 7
    • 0028402339 scopus 로고
    • New electronic canal measuring device based on the ratio method
    • Kobayashi C., and Suda H. New electronic canal measuring device based on the ratio method. J Endod 20 (1994) 111-114
    • (1994) J Endod , vol.20 , pp. 111-114
    • Kobayashi, C.1    Suda, H.2
  • 9
    • 33644589221 scopus 로고    scopus 로고
    • Accuracy of root length determination using Tri Auto ZX and ProTaper instruments: an in vitro study
    • Carneiro E., Bramante C.M., Picoli F., Letra A., da Silva Neto U.X., and Menezes R. Accuracy of root length determination using Tri Auto ZX and ProTaper instruments: an in vitro study. J Endod 32 (2006) 142-144
    • (2006) J Endod , vol.32 , pp. 142-144
    • Carneiro, E.1    Bramante, C.M.2    Picoli, F.3    Letra, A.4    da Silva Neto, U.X.5    Menezes, R.6
  • 10
    • 33846223285 scopus 로고    scopus 로고
    • Efficacy of two rotary NiTi instruments in the removal of gutta-percha during root canal retreatment
    • Saad A.Y., Al-Hadlaq S.M., and Al-Katheeri N.H. Efficacy of two rotary NiTi instruments in the removal of gutta-percha during root canal retreatment. J Endod 33 (2007) 38-41
    • (2007) J Endod , vol.33 , pp. 38-41
    • Saad, A.Y.1    Al-Hadlaq, S.M.2    Al-Katheeri, N.H.3
  • 11
    • 33748294360 scopus 로고    scopus 로고
    • Efficacy of automated versus hand instrumentation during root canal retreatment: an ex vivo study
    • de Carvalho Maciel A.C., and Zaccaro Scelza M.F. Efficacy of automated versus hand instrumentation during root canal retreatment: an ex vivo study. Int Endod J 39 (2006) 779-784
    • (2006) Int Endod J , vol.39 , pp. 779-784
    • de Carvalho Maciel, A.C.1    Zaccaro Scelza, M.F.2
  • 12
    • 1542570492 scopus 로고    scopus 로고
    • The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files
    • Thomas A.S., Hartwell G.R., and Moon P.C. The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files. J Endod 29 (2003) 662-663
    • (2003) J Endod , vol.29 , pp. 662-663
    • Thomas, A.S.1    Hartwell, G.R.2    Moon, P.C.3
  • 13
    • 0036484408 scopus 로고    scopus 로고
    • Accuracy of a new apex locator: an in vitro study
    • Kaufman A.Y., Keila S., and Yoshpe M. Accuracy of a new apex locator: an in vitro study. Int Endod J 35 (2002) 186-192
    • (2002) Int Endod J , vol.35 , pp. 186-192
    • Kaufman, A.Y.1    Keila, S.2    Yoshpe, M.3
  • 14
    • 33947130655 scopus 로고    scopus 로고
    • Influence of embedding media on the assessment of electronic apex locators
    • Baldi J.V., Victorino F.R., Bernardes R.A., et al. Influence of embedding media on the assessment of electronic apex locators. J Endod 33 (2007) 476-479
    • (2007) J Endod , vol.33 , pp. 476-479
    • Baldi, J.V.1    Victorino, F.R.2    Bernardes, R.A.3
  • 15
    • 0346765851 scopus 로고
    • Reliability of Root ZX apex locator tested by an in vitro model
    • (abstract)
    • Kaufman A.Y., and Katz A. Reliability of Root ZX apex locator tested by an in vitro model. (abstract). J Endod 19 (1993) 201
    • (1993) J Endod , vol.19 , pp. 201
    • Kaufman, A.Y.1    Katz, A.2
  • 16
    • 0036834281 scopus 로고    scopus 로고
    • A simple model to demonstrate the apex locator
    • Tinaz A.C., Alacam T., and Topuz O. A simple model to demonstrate the apex locator. Int Endod J 35 (2002) 940-945
    • (2002) Int Endod J , vol.35 , pp. 940-945
    • Tinaz, A.C.1    Alacam, T.2    Topuz, O.3
  • 17
    • 1342343190 scopus 로고    scopus 로고
    • The accuracy of electronic working length determination
    • Hoer D., and Attin T. The accuracy of electronic working length determination. Int Endod J 37 (2004) 125-131
    • (2004) Int Endod J , vol.37 , pp. 125-131
    • Hoer, D.1    Attin, T.2
  • 18
    • 77049220185 scopus 로고
    • Microscopic investigation of root apexes
    • Kuttler Y. Microscopic investigation of root apexes. J Am Dent Assoc 50 (1955) 544-552
    • (1955) J Am Dent Assoc , vol.50 , pp. 544-552
    • Kuttler, Y.1
  • 19
    • 0020806709 scopus 로고
    • Expanded use of the electronic canal length measuring devices
    • Nahmias Y., Aurelio J.A., and Gerstein H. Expanded use of the electronic canal length measuring devices. J Endod 9 (1983) 347-349
    • (1983) J Endod , vol.9 , pp. 347-349
    • Nahmias, Y.1    Aurelio, J.A.2    Gerstein, H.3
  • 20
    • 0025617602 scopus 로고
    • Electronic determination of root canal length by newly developed measuring device: influences of the diameter of apical foramen, the size of K file and the root canal irrigants
    • Saito T., and Yamashita Y. Electronic determination of root canal length by newly developed measuring device: influences of the diameter of apical foramen, the size of K file and the root canal irrigants. Dent Jpn (Tokyo) 27 (1990) 65-72
    • (1990) Dent Jpn (Tokyo) , vol.27 , pp. 65-72
    • Saito, T.1    Yamashita, Y.2
  • 21
    • 0026836703 scopus 로고
    • Variables affecting electronic root canal measurement
    • Wu Y.N., Shi J.N., Huang L.Z., and Xu Y.Y. Variables affecting electronic root canal measurement. Int Endod J 25 (1992) 88-92
    • (1992) Int Endod J , vol.25 , pp. 88-92
    • Wu, Y.N.1    Shi, J.N.2    Huang, L.Z.3    Xu, Y.Y.4
  • 22
    • 33645103350 scopus 로고    scopus 로고
    • Evaluation of the accuracy of three electronic apex locators using glass tubules
    • Fan W., Fan B., Gutmann J.L., Bian Z., and Fan M.W. Evaluation of the accuracy of three electronic apex locators using glass tubules. Int Endod J 39 (2006) 127-135
    • (2006) Int Endod J , vol.39 , pp. 127-135
    • Fan, W.1    Fan, B.2    Gutmann, J.L.3    Bian, Z.4    Fan, M.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.