메뉴 건너뛰기




Volumn 28, Issue 8, 2002, Pages 595-598

The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; HYPOCHLORITE SODIUM;

EID: 0036675072     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004770-200208000-00008     Document Type: Article
Times cited : (65)

References (17)
  • 1
    • 0027604758 scopus 로고
    • Accuracy of an electronic apex locator: A clinical evaluation in maxillary molars
    • Hembrough JH, Weine FS, Pisano JV, Eskoz N. Accuracy of an electronic apex locator: a clinical evaluation in maxillary molars. J Endodon 1993;19:242-6.
    • (1993) J Endodon , vol.19 , pp. 242-246
    • Hembrough, J.H.1    Weine, F.S.2    Pisano, J.V.3    Eskoz, N.4
  • 3
    • 0347025124 scopus 로고
    • Experimental studies on ionophoresis
    • Suzuki K. Experimental studies on ionophoresis. J Jpn Stomatol 1942; 16:411-7.
    • (1942) J Jpn Stomatol , vol.16 , pp. 411-417
    • Suzuki, K.1
  • 4
    • 84886609551 scopus 로고
    • New method for measuring the length of the root canal
    • Sunada I. New method for measuring the length of the root canal. J Dent Res 1962;41:375-87.
    • (1962) J Dent Res , vol.41 , pp. 375-387
    • Sunada, I.1
  • 5
    • 0029286032 scopus 로고
    • An in vivo evaluation of the ENDEX and RCM Mark II electronic apex locators in root canals with different contents
    • Arora R, Gulabivala K. An in vivo evaluation of the ENDEX and RCM Mark II electronic apex locators in root canals with different contents. Oral Surg Oral Med Oral Pathol 1995;79:497-503.
    • (1995) Oral Surg Oral Med Oral Pathol , vol.79 , pp. 497-503
    • Arora, R.1    Gulabivala, K.2
  • 6
    • 0028402339 scopus 로고
    • New electronic canal measuring device based on the ratio method
    • Kobayashi C, Suda H. New electronic canal measuring device based on the ratio method. J Endodon 1994;20:111-4.
    • (1994) J Endodon , vol.20 , pp. 111-114
    • Kobayashi, C.1    Suda, H.2
  • 7
    • 0030275701 scopus 로고    scopus 로고
    • An in vivo evaluation of Root ZX electronic apex locator
    • Shabahang S, Goon W, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endodon 1996;22:616-8.
    • (1996) J Endodon , vol.22 , pp. 616-618
    • Shabahang, S.1    Goon, W.2    Gluskin, A.H.3
  • 8
    • 0031600449 scopus 로고    scopus 로고
    • An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals
    • Dunlap CA, Remeikis NA, BeGole EA, Rauschenberger CR. An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endodon 1998;24:48-50.
    • (1998) J Endodon , vol.24 , pp. 48-50
    • Dunlap, C.A.1    Remeikis, N.A.2    Begole, E.A.3    Rauschenberger, C.R.4
  • 10
    • 0032086679 scopus 로고    scopus 로고
    • SEM study of in vivo accuracy of the Root ZX electronic apex locator
    • Pagavino G, Pace R, Baccetti T. A SEM study of in vivo accuracy of the Root ZX electronic apex locator. J Endodon 1998;24:438-41.
    • (1998) J Endodon , vol.24 , pp. 438-441
    • Pagavino, G.1    Pace, R.2    Baccetti, T.A.3
  • 11
    • 0034207998 scopus 로고    scopus 로고
    • Effect of using electronic apex locators on selected parameters
    • Fouad AF, Reid LC. Effect of using electronic apex locators on selected parameters. J Endodon 2000;26:364-7.
    • (2000) J Endodon , vol.26 , pp. 364-367
    • Fouad, A.F.1    Reid, L.C.2
  • 12
    • 0023285935 scopus 로고
    • An experimental study of the principle of electronic root canal measurement
    • Huang L. An experimental study of the principle of electronic root canal measurement. J Endodon 1987;13:60-4.
    • (1987) J Endodon , vol.13 , pp. 60-64
    • Huang, L.1
  • 13
    • 0030274468 scopus 로고    scopus 로고
    • Electronic length measurement using small and large files in enlarged canals
    • Nguyen HQ, Kaufman AY, Komorowski RC, Friedman S. Electronic length measurement using small and large files in enlarged canals. Int Endod J 1996;29:359-64.
    • (1996) Int Endod J , vol.29 , pp. 359-364
    • Nguyen, H.Q.1    Kaufman, A.Y.2    Komorowski, R.C.3    Friedman, S.4
  • 14
    • 0033088550 scopus 로고    scopus 로고
    • In vitro evaluation of the reliability of the Root ZX electronic apex locator
    • Ounsi HF, Naaman A. In vitro evaluation of the reliability of the Root ZX electronic apex locator. Int Endod J 1999;32:120-3.
    • (1999) Int Endod J , vol.32 , pp. 120-123
    • Ounsi, H.F.1    Naaman, A.2
  • 15
    • 0033223699 scopus 로고    scopus 로고
    • An in vitro comparison of two modern apex locators
    • Weiger R, John C, Geigle H, Löst C. An in vitro comparison of two modern apex locators. J Endodon 1999;25:765-8.
    • (1999) J Endodon , vol.25 , pp. 765-768
    • Weiger, R.1    John, C.2    Geigle, H.3    Löst, C.4
  • 17
    • 0024849016 scopus 로고
    • An in vitro comparison of five root canal length measuring instruments
    • Fouad AF, Krell KV. An in vitro comparison of five root canal length measuring instruments. J Endodon 1989;15:573-7.
    • (1989) J Endodon , vol.15 , pp. 573-577
    • Fouad, A.F.1    Krell, K.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.