메뉴 건너뛰기




Volumn 36, Issue 2, 2009, Pages 556-568

Vision 2020: Proton therapy

Author keywords

Hadron therapy; Particle therapy; Proton therapy; Radiation oncology

Indexed keywords

DISEASE CONTROL; DISEASES; ONCOLOGY; PHOTONS; PROTON BEAMS; QUALITY ASSURANCE; RADIOTHERAPY;

EID: 59249093490     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3058485     Document Type: Review
Times cited : (136)

References (78)
  • 1
    • 33646160306 scopus 로고
    • Collisions of alpha particles with light atoms. III. Nitrogen and oxygen atoms
    • E. Rutherford, " Collisions of alpha particles with light atoms. III. Nitrogen and oxygen atoms.," Philos. Mag. 37, 571-580 (1919).
    • (1919) Philos. Mag. , vol.37 , pp. 571-580
    • Rutherford, E.1
  • 3
    • 0040138724 scopus 로고
    • Radiological use of fast protons
    • R. R. Wilson, " Radiological use of fast protons.," Radiology 47, 487-491 (1946).
    • (1946) Radiology , vol.47 , pp. 487-491
    • Wilson, R.R.1
  • 5
    • 85027217633 scopus 로고    scopus 로고
    • newsletter. Available from
    • " Particles. " newsletter. Available from: http://ptcog.web. psi.ch/ptcentres.html
    • Particles
  • 6
    • 59249097276 scopus 로고    scopus 로고
    • Treatment delivery systems
    • T. F. DeLaney and H. M. Kooy, eds. (Lippincott Williams and Wilkins, Philadelphia)
    • B. Gottschalk and E. Pedroni, " Treatment delivery systems.," Proton and Charged Particle Radiotherapy, T. F. DeLaney, and, H. M. Kooy, eds. (Lippincott Williams and Wilkins, Philadelphia, 2008), pp. 33-49.
    • (2008) Proton and Charged Particle Radiotherapy , pp. 33-49
    • Gottschalk, B.1    Pedroni, E.2
  • 7
    • 0000277337 scopus 로고
    • Instrumentation for treatment of cancer using proton and light-ion beams
    • W. T. Chu, B. A. Ludewigt, and T. R. Renner, " Instrumentation for treatment of cancer using proton and light-ion beams.," Rev. Sci. Instrum. 64, 2055-2122 (1993).
    • (1993) Rev. Sci. Instrum. , vol.64 , pp. 2055-2122
    • Chu, W.T.1    Ludewigt, B.A.2    Renner, T.R.3
  • 8
    • 39049164210 scopus 로고    scopus 로고
    • Intensity modulated proton therapy and its sensitivity to treatment uncertainties. 1. the potential effects of calculational uncertainties
    • A. J. Lomax, " Intensity modulated proton therapy and its sensitivity to treatment uncertainties. 1. The potential effects of calculational uncertainties.," Phys. Med. Biol. 53, 1027-1042 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 1027-1042
    • Lomax, A.J.1
  • 9
    • 39049126842 scopus 로고    scopus 로고
    • Intensity modulated proton therapy and its sensitivity to treatment uncertainties. 2. the potential effects of inter-fraction and inter-field motions
    • A. J. Lomax, " Intensity modulated proton therapy and its sensitivity to treatment uncertainties. 2. The potential effects of inter-fraction and inter-field motions.," Phys. Med. Biol. 53, 1043-1056 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 1043-1056
    • Lomax, A.J.1
  • 11
    • 28844435764 scopus 로고    scopus 로고
    • Number of patients potentially eligible for proton therapy
    • B. Glimelius, " Number of patients potentially eligible for proton therapy.," Acta Oncol. 44, 836-849 (2005).
    • (2005) Acta Oncol. , vol.44 , pp. 836-849
    • Glimelius, B.1
  • 12
    • 36048962204 scopus 로고    scopus 로고
    • Comparison of intensity modulated x-ray therapy and intensity modulated proton therapy for selective subvolume boosting: A phantom study
    • R. Flynn, D. Barbee, T. Mackie, and R. Jeraj, " Comparison of intensity modulated x-ray therapy and intensity modulated proton therapy for selective subvolume boosting: A phantom study.," Phys. Med. Biol. 52, 6073-6091 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , pp. 6073-6091
    • Flynn, R.1    Barbee, D.2    MacKie, T.3    Jeraj, R.4
  • 13
    • 40049105420 scopus 로고    scopus 로고
    • A computational implementation and comparison of several intensity modulated proton therapy treatment planning algorithms
    • L. Haisen, H. Romeijn, H. Fox, J. Palta, and J. Dempsey, " A computational implementation and comparison of several intensity modulated proton therapy treatment planning algorithms.," Med. Phys. 35, 1103-1112 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 1103-1112
    • Haisen, L.1    Romeijn, H.2    Fox, H.3    Palta, J.4    Dempsey, J.5
  • 14
    • 0032976831 scopus 로고    scopus 로고
    • A treatment planning inter-comparison of protons and intensity-modulated photon therapy
    • A. J. Lomax, " A treatment planning inter-comparison of protons and intensity-modulated photon therapy.," Radiother. Oncol. 51, 257-271 (1999).
    • (1999) Radiother. Oncol. , vol.51 , pp. 257-271
    • Lomax, A.J.1
  • 15
    • 33947535720 scopus 로고    scopus 로고
    • Particle radiation therapy using proton and heavier ion beams
    • D. Schultz-Ertner and H. Tsujii, " Particle radiation therapy using proton and heavier ion beams.," J. Clin. Oncol. 25, 953-964 (2007).
    • (2007) J. Clin. Oncol. , vol.25 , pp. 953-964
    • Schultz-Ertner, D.1    Tsujii, H.2
  • 16
    • 0027452557 scopus 로고
    • Clinical results of fractionated proton therapy
    • H. Tsujii, " Clinical results of fractionated proton therapy.," Int. J. Radiat. Oncol., Biol., Phys. 25, 49-60 (1993).
    • (1993) Int. J. Radiat. Oncol., Biol., Phys. , vol.25 , pp. 49-60
    • Tsujii, H.1
  • 17
    • 9144264801 scopus 로고    scopus 로고
    • Proton beams to replace photon beams in radical dose treatments
    • H. Suit, " Proton beams to replace photon beams in radical dose treatments.," Acta Oncol. 42, 800-808 (2003).
    • (2003) Acta Oncol. , vol.42 , pp. 800-808
    • Suit, H.1
  • 21
    • 34248144305 scopus 로고    scopus 로고
    • Experiences with an application of industrial robotics for accurate patient positioning in proton radiotherapy
    • C. E. Allgower, A. N. Schreuder, J. B. Farr, and A. E. Mascia, " Experiences with an application of industrial robotics for accurate patient positioning in proton radiotherapy.," Int. J. Med. Robotics Comput. Assist. Surg. 3, 72-81 (2007).
    • (2007) Int. J. Med. Robotics Comput. Assist. Surg. , vol.3 , pp. 72-81
    • Allgower, C.E.1    Schreuder, A.N.2    Farr, J.B.3    Mascia, A.E.4
  • 22
    • 0028891524 scopus 로고
    • The 200 MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization
    • E. Pedroni, " The 200 MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization.," Med. Phys. 22, 37-53 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 37-53
    • Pedroni, E.1
  • 23
    • 9244236564 scopus 로고    scopus 로고
    • Treatment planning and verification of proton therapy using spot scanning: Initial experience
    • A. Lomax, " Treatment planning and verification of proton therapy using spot scanning: Initial experience.," Med. Phys. 31, 3150-3157 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 3150-3157
    • Lomax, A.1
  • 24
    • 24644443217 scopus 로고    scopus 로고
    • Comparison of conventional-dose vs. high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate: A randomized controlled trial
    • A. L. Zeitman, " Comparison of conventional-dose vs. high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate: A randomized controlled trial.," JAMA, J. Am. Med. Assoc. 294, 1233-1239 (2005).
    • (2005) JAMA, J. Am. Med. Assoc. , vol.294 , pp. 1233-1239
    • Zeitman, A.L.1
  • 25
    • 38349183277 scopus 로고    scopus 로고
    • Should randomized clinical trial be required for proton radiotherapy?
    • M. Goitein and J. Cox, " Should randomized clinical trial be required for proton radiotherapy? " J. Clin. Oncol. 26, 175-176 (2008).
    • (2008) J. Clin. Oncol. , vol.26 , pp. 175-176
    • Goitein, M.1    Cox, J.2
  • 26
    • 39149105939 scopus 로고    scopus 로고
    • Should positive phase III clinical trial data be required before proton beam therapy is more widely adopted? No
    • H. Suit " Should positive phase III clinical trial data be required before proton beam therapy is more widely adopted? No.," Radiother. Oncol. 86, 148-153 (2008).
    • (2008) Radiother. Oncol. , vol.86 , pp. 148-153
    • Suit, H.1
  • 27
    • 0037305954 scopus 로고    scopus 로고
    • The relative costs of proton and x-ray radiation therapy
    • M. Goitein and M. Jermann, " The relative costs of proton and x-ray radiation therapy.," Clin. Oncol. 15, S37-S50 (2003).
    • (2003) Clin. Oncol. , vol.15
    • Goitein, M.1    Jermann, M.2
  • 28
    • 85027224869 scopus 로고    scopus 로고
    • PTCOG Educational Workshop, Jacksonville, Fl, May 2008, (accessed November 1).
    • Y. Jongen, " Cyclotrons and synchrocyclotrons.," PTCOG Educational Workshop, Jacksonville, Fl, May 2008, http://ptcog.web.psi.ch/ ptcog47-talks.html (accessed November 1, 2008).
    • (2008) Cyclotrons and Synchrocyclotrons
    • Jongen, Y.1
  • 29
    • 85027226220 scopus 로고    scopus 로고
    • PTCOG Educational Workshop, Jacksonville, Fl, May 2008, (accessed November 1).
    • J. Flanz, " Particle therapy: Technical approaches.," PTCOG Educational Workshop, Jacksonville, Fl, May 2008, http://ptcog.web.psi.ch/ ptcog47-talks.html (accessed November 1, 2008).
    • (2008) Particle Therapy: Technical Approaches
    • Flanz, J.1
  • 30
    • 0028307285 scopus 로고
    • A superconducting cyclotron for neutron radiation therapy
    • R. L. Maughan and W. E. Powers, " A superconducting cyclotron for neutron radiation therapy.," Med. Phys. 21, 779-785 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 779-785
    • Maughan, R.L.1    Powers, W.E.2
  • 31
    • 33847114418 scopus 로고    scopus 로고
    • New concepts in FFAG design for secondary beam facilities and other applications
    • M. D. Craddock, " New concepts in FFAG design for secondary beam facilities and other applications.," Proceedings of EPAC 2005, 2005, pp. 261-263.
    • (2005) Proceedings of EPAC 2005 , pp. 261-263
    • Craddock, M.D.1
  • 32
    • 0343227907 scopus 로고    scopus 로고
    • A new type of rf cavity for high intensity proton synchrotron using high permeability magnetic alloy
    • Y. Mori, " A new type of rf cavity for high intensity proton synchrotron using high permeability magnetic alloy.," Proceedings of EPAC 1998, pp. 299-301.
    • Proceedings of EPAC 1998 , pp. 299-301
    • Mori, Y.1
  • 33
    • 0006289457 scopus 로고    scopus 로고
    • Development of a FFAG proton synchrotron
    • M. Aiba, " Development of a FFAG proton synchrotron.," Proceedings of EPAC 2000, pp. 581-583.
    • Proceedings of EPAC 2000 , pp. 581-583
    • Aiba, M.1
  • 34
    • 0033343172 scopus 로고    scopus 로고
    • Fixed field circular accelerator designs
    • C. Johnstone, " Fixed field circular accelerator designs.," Proceedings of EPAC 1999, pp. 3068-3070.
    • Proceedings of EPAC 1999 , pp. 3068-3070
    • Johnstone, C.1
  • 35
    • 34547282650 scopus 로고    scopus 로고
    • Hadron cancer therapy complex using nonscaling fixed field alternating gradient accelerator and gantry design
    • E. Keil, A. M. Sessler, and D. Trbojevic, " Hadron cancer therapy complex using nonscaling fixed field alternating gradient accelerator and gantry design.," Phys. Rev. ST Accel. Beams 10, 054701 (2007).
    • (2007) Phys. Rev. ST Accel. Beams , vol.10 , pp. 054701
    • Keil, E.1    Sessler, A.M.2    Trbojevic, D.3
  • 36
    • 33750921269 scopus 로고    scopus 로고
    • Development of a laser-driven proton accelerator for cancer therapy
    • C.-M. Ma, " Development of a laser-driven proton accelerator for cancer therapy.," Laser Phys., 16, 1-8 (2006).
    • (2006) Laser Phys. , vol.16 , pp. 1-8
    • Ma, C.-M.1
  • 37
    • 0036912840 scopus 로고    scopus 로고
    • Particle in cell simulation of laser-accelerated proton beams for radiation therapy
    • E. Fourkal, B. Shahine, M. Ding, J.-S. Li, T. Tajima, and C.-M. Ma, " Particle in cell simulation of laser-accelerated proton beams for radiation therapy.," Med. Phys. 29, 2788-2798 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2788-2798
    • Fourkal, E.1    Shahine, B.2    Ding, M.3    Li, J.-S.4    Tajima, T.5    Ma, C.-M.6
  • 38
    • 42949176596 scopus 로고    scopus 로고
    • Accelerating protons to therapeutic energies with ultraintense, ultraclean, and ultrashort laser pulses
    • S. S. Bulanov, " Accelerating protons to therapeutic energies with ultraintense, ultraclean, and ultrashort laser pulses.," Med. Phys. 35, 1770-1776 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 1770-1776
    • Bulanov, S.S.1
  • 39
    • 44649154330 scopus 로고    scopus 로고
    • A compact linac for intensity modulated proton therapy based on a dielectric wall accelerator
    • G. J. Caporaso, " A compact linac for intensity modulated proton therapy based on a dielectric wall accelerator.," Phys. Medica 24, 98-101 (2008).
    • (2008) Phys. Medica , vol.24 , pp. 98-101
    • Caporaso, G.J.1
  • 40
    • 59249101654 scopus 로고    scopus 로고
    • A proposal for a novel compact intensity modulated proton therapy system using a dielectric wall accelerator
    • T. R. Mackie, " A proposal for a novel compact intensity modulated proton therapy system using a dielectric wall accelerator.," Med. Phys. 34, 2628 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 2628
    • MacKie, T.R.1
  • 42
    • 33847682874 scopus 로고    scopus 로고
    • Design study of a raster scanning system for moving target irradiation in heavy-ion therapy
    • T. Furukawa, T. Inaniwa, S. Sato, T. Tomitani, S. Iinohara, K. Noda, and T. Kanai, " Design study of a raster scanning system for moving target irradiation in heavy-ion therapy.," Med. Phys. 34, 1085-1097 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 1085-1097
    • Furukawa, T.1    Inaniwa, T.2    Sato, S.3    Tomitani, T.4    Iinohara, S.5    Noda, K.6    Kanai, T.7
  • 44
    • 51849122521 scopus 로고    scopus 로고
    • Clinical implementation of full Monte Carlo dose calculation in proton beam therapy
    • H. Paganetti, H. Jiang, K. Parodi, R. Slopsema, and M. Engelsman, " Clinical implementation of full Monte Carlo dose calculation in proton beam therapy.," Phys. Med. Biol. 53, 4825-4853 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4825-4853
    • Paganetti, H.1    Jiang, H.2    Parodi, K.3    Slopsema, R.4    Engelsman, M.5
  • 45
    • 16444381177 scopus 로고    scopus 로고
    • 4D Monte Carlo simulation of proton beam scanning: Modeling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry
    • H. Paganetti, H. Jiang, and A. Trofimov, " 4D Monte Carlo simulation of proton beam scanning: Modeling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry.," Phys. Med. Biol. 50, 983-990 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 983-990
    • Paganetti, H.1    Jiang, H.2    Trofimov, A.3
  • 46
    • 16444382388 scopus 로고    scopus 로고
    • The Monte Carlo SRNA-VOX code for 3D proton dose distribution in voxelized geometry using CT data
    • R. D. Ilie, V. Spasic-Jokic, P. Belicev, and M. Dragovic, " The Monte Carlo SRNA-VOX code for 3D proton dose distribution in voxelized geometry using CT data.," Phys. Med. Biol. 50, 1011-1017 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 1011-1017
    • Ilie, R.D.1    Spasic-Jokic, V.2    Belicev, P.3    Dragovic, M.4
  • 47
    • 27644597172 scopus 로고    scopus 로고
    • Monte Carlo simulations of a nozzle for the treatment of ocular tumors with high-energy proton beams
    • W. Newhauser, " Monte Carlo simulations of a nozzle for the treatment of ocular tumors with high-energy proton beams.," Phys. Med. Biol. 50, 5229-5249 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 5229-5249
    • Newhauser, W.1
  • 48
    • 34547115214 scopus 로고    scopus 로고
    • Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm
    • W. Newhauser, " Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm.," Phys. Med. Biol. 52, 4569-4584 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , pp. 4569-4584
    • Newhauser, W.1
  • 49
    • 41049103315 scopus 로고    scopus 로고
    • Worst case optimization: A method to account for uncertainties in the optimization of intensity modulated proton therapy
    • D. Pflugfelder, J. J. Wilkens, and U. Oelfke, " Worst case optimization: A method to account for uncertainties in the optimization of intensity modulated proton therapy.," Phys. Med. Biol. 53, 1689-1700 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 1689-1700
    • Pflugfelder, D.1    Wilkens, J.J.2    Oelfke, U.3
  • 50
    • 34249320889 scopus 로고    scopus 로고
    • Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy
    • K. Parodi, " Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy.," Int. J. Radiat. Oncol., Biol., Phys. 68, 920-934 (2007).
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.68 , pp. 920-934
    • Parodi, K.1
  • 51
    • 44349190821 scopus 로고    scopus 로고
    • Comparison between in-beam and offline positron emission tomography imaging of proton and carbon ion therapeutic irradiation at synchrotron- and cyclotron-based facilities
    • K. Parodi, T. Bortfeld, and T. Haberer, " Comparison between in-beam and offline positron emission tomography imaging of proton and carbon ion therapeutic irradiation at synchrotron- and cyclotron-based facilities.," Int. J. Radiat. Oncol., Biol., Phys. 71, 945-956 (2008).
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.71 , pp. 945-956
    • Parodi, K.1    Bortfeld, T.2    Haberer, T.3
  • 52
    • 33750557453 scopus 로고    scopus 로고
    • Dose-volume delivery guided proton therapy using beam on-line PET system
    • T. Nishio and T. Ogino, " Dose-volume delivery guided proton therapy using beam on-line PET system.," Med. Phys. 33, 4190-4197 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 4190-4197
    • Nishio, T.1    Ogino, T.2
  • 53
    • 48349094227 scopus 로고    scopus 로고
    • Quantitative assessment of the physical potential of proton beam range verification with PET/CT
    • A. Knopf, K. Parodi, H. Paganetti, E. Cascio, A. Bonab, and T. Bortfeld, " Quantitative assessment of the physical potential of proton beam range verification with PET/CT.," Phys. Med. Biol. 53, 4137-4151 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4137-4151
    • Knopf, A.1    Parodi, K.2    Paganetti, H.3    Cascio, E.4    Bonab, A.5    Bortfeld, T.6
  • 54
    • 0001069532 scopus 로고
    • Representation of a function by its line integrals with some radiological applications
    • A. M. Cormack, " Representation of a function by its line integrals with some radiological applications.," J. Appl. Phys. 34, 2722-2727 (1963).
    • (1963) J. Appl. Phys. , vol.34 , pp. 2722-2727
    • Cormack, A.M.1
  • 55
    • 12544260746 scopus 로고
    • Representation of a function by its line integrals with some radiological applications II
    • A. M. Cormack, " Representation of a function by its line integrals with some radiological applications II.," J. Appl. Phys. 35, 2908-2913 (1964).
    • (1964) J. Appl. Phys. , vol.35 , pp. 2908-2913
    • Cormack, A.M.1
  • 56
    • 0000257936 scopus 로고
    • Proton radiography
    • A. M. Koehler, " Proton radiography.," Science 160, 303-304 (1968).
    • (1968) Science , vol.160 , pp. 303-304
    • Koehler, A.M.1
  • 57
    • 0017120914 scopus 로고
    • Quantitative proton tomography: Preliminary experiments
    • A. M. Cormack and A. M. Koehler, " Quantitative proton tomography: Preliminary experiments.," Phys. Med. Biol. 21, 560-569 (1976).
    • (1976) Phys. Med. Biol. , vol.21 , pp. 560-569
    • Cormack, A.M.1    Koehler, A.M.2
  • 59
    • 0028900136 scopus 로고
    • Proton radiography as a tool for quality control in proton therapy
    • U. Schneider and E. Pedroni, " Proton radiography as a tool for quality control in proton therapy.," Med. Phys. 22, 353-363 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 353-363
    • Schneider, U.1    Pedroni, E.2
  • 61
    • 0033968791 scopus 로고    scopus 로고
    • The measurement of proton stopping powers using proton-cone-beam computed tomography
    • P. Zygmanski, K. P. Gall, M. S. Z. Rabin, and S. J. Rosenthal, " The measurement of proton stopping powers using proton-cone-beam computed tomography.," Phys. Med. Biol. 45, 511-528 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 511-528
    • Zygmanski, P.1    Gall, K.P.2    Rabin, M.S.Z.3    Rosenthal, S.J.4
  • 62
    • 3342890639 scopus 로고    scopus 로고
    • Conceptual design of a proton computed tomography system for applications in proton radiation therapy
    • R. Schulte, " Conceptual design of a proton computed tomography system for applications in proton radiation therapy.," IEEE Trans. Nucl. Sci. 51, 866-872 (2004).
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 866-872
    • Schulte, R.1
  • 63
    • 0030065290 scopus 로고    scopus 로고
    • The calibration of CT Hounsfield units for radiotherapy treatment planning
    • U. Schneider, E. Pedroni, and A. Lomax, " The calibration of CT Hounsfield units for radiotherapy treatment planning.," Phys. Med. Biol. 41, 111-124, (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 111-124
    • Schneider, U.1    Pedroni, E.2    Lomax, A.3
  • 65
    • 27844595423 scopus 로고    scopus 로고
    • Proton computed tomography as a tool for proton therapy planning: Preliminary computer simulations and comparisons with x-ray CT basics
    • J. T. de Assis, " Proton computed tomography as a tool for proton therapy planning: Preliminary computer simulations and comparisons with x-ray CT basics.," X-Ray Spectrom. 34, 481-492 (2005).
    • (2005) X-Ray Spectrom. , vol.34 , pp. 481-492
    • De Assis, J.T.1
  • 66
  • 67
    • 0343962206 scopus 로고    scopus 로고
    • Quality assurance for a treatment planning system in scanned ion beam therapy
    • O. Jäkel, G. H. Hartmann, C. P. Karger, P. Heeg, and J. Rassow, " Quality assurance for a treatment planning system in scanned ion beam therapy.," Med. Phys. 27, 1588-1600 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1588-1600
    • Jäkel, O.1    Hartmann, G.H.2    Karger, C.P.3    Heeg, P.4    Rassow, J.5
  • 68
    • 14544292041 scopus 로고    scopus 로고
    • Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams
    • E. Pedroni, S. Scheib, T. Böhringer, A. Coray, M. Grossmann, S. Lin, and A. Lomax, " Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams.," Phys. Med. Biol. 50, 541-561 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 541-561
    • Pedroni, E.1    Scheib, S.2    Böhringer, T.3    Coray, A.4    Grossmann, M.5    Lin, S.6    Lomax, A.7
  • 69
    • 0345035258 scopus 로고    scopus 로고
    • A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    • C. P. Karger, O. Jäkel, and G. H. Hartmann, " A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions.," Med. Phys. 26, 2125-2132 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2125-2132
    • Karger, C.P.1    Jäkel, O.2    Hartmann, G.H.3
  • 70
    • 34347373700 scopus 로고    scopus 로고
    • Multichannel detectors for profile measurements in clinical proton fields
    • D. Nichiporov and K. Solberg, " Multichannel detectors for profile measurements in clinical proton fields.," Med. Phys. 34, 2683-2690 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 2683-2690
    • Nichiporov, D.1    Solberg, K.2
  • 71
    • 0033735266 scopus 로고    scopus 로고
    • Performance of a fluorescent screen and CCD camera as a two dimensional system for dynamic treatment techniques
    • S. Boon, P. van Luijk, T. Böhringer, A. Coray, A. Lomax, E. Pedroni, B. Schaffner, and J. M. Schippers, " Performance of a fluorescent screen and CCD camera as a two dimensional system for dynamic treatment techniques.," Med. Phys. 27, 2198-2208 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2198-2208
    • Boon, S.1    Van Luijk, P.2    Böhringer, T.3    Coray, A.4    Lomax, A.5    Pedroni, E.6    Schaffner, B.7    Schippers, J.M.8
  • 72
    • 0031148917 scopus 로고    scopus 로고
    • Radiochromic film dosimetry for clinical proton beams
    • S. Vatnitsky, " Radiochromic film dosimetry for clinical proton beams.," Appl. Radiat. Isot. 48, 643-651 (1997).
    • (1997) Appl. Radiat. Isot. , vol.48 , pp. 643-651
    • Vatnitsky, S.1
  • 73
    • 0028866582 scopus 로고
    • Investigation of applicability of alanine and radiochromic detectors to dosimetry of proton clinical beams
    • D. Nichiporov, " Investigation of applicability of alanine and radiochromic detectors to dosimetry of proton clinical beams.," Appl. Radiat. Isot. 46, 1355-1362 (1995).
    • (1995) Appl. Radiat. Isot. , vol.46 , pp. 1355-1362
    • Nichiporov, D.1
  • 74
    • 85027228216 scopus 로고    scopus 로고
    • M.S. thesis, The University of Texas Health Science Center at Houston, Graduate School of Biomedical Sciences.
    • W. B. Warren, " Evaluation of ®Bang polymer gel dosimeters in proton beams.," M.S. thesis, The University of Texas Health Science Center at Houston, Graduate School of Biomedical Sciences, 2007.
    • (2007) Evaluation of ®bang Polymer Gel Dosimeters in Proton Beams
    • Warren, W.B.1
  • 75
    • 0025255518 scopus 로고
    • The radiobiological and physical basis for radiotherapy with protons and heavier ions
    • G. Kraft, " The radiobiological and physical basis for radiotherapy with protons and heavier ions.," Strahlenther. Onkol. 166, 10-13 (1990).
    • (1990) Strahlenther. Onkol. , vol.166 , pp. 10-13
    • Kraft, G.1
  • 76
    • 0033011695 scopus 로고    scopus 로고
    • Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
    • T. Kanai, " Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. 64, 201-210 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.64 , pp. 201-210
    • Kanai, T.1
  • 77
    • 0742289163 scopus 로고    scopus 로고
    • Recent advances in light ion radiation therapy
    • A. Brahme, " Recent advances in light ion radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. 58, 603-616 (2004).
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.58 , pp. 603-616
    • Brahme, A.1
  • 78
    • 85027239158 scopus 로고    scopus 로고
    • PTCOG Scientific Meeting, Jacksonville, Fl, May 2008, (accessed November 1).
    • R. Mohan, " Achieving what-you-see-is-what-you-get in proton therapy.," PTCOG Scientific Meeting, Jacksonville, Fl, May 2008, http://ptcog.web.psi.ch/ptcog47-talks.html (accessed November 1, 2008).
    • (2008) Achieving What-you-see-is-what-you-get in Proton Therapy
    • Mohan, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.