메뉴 건너뛰기




Volumn 27, Issue 7, 2000, Pages 1588-1600

Quality assurance for a treatment planning system in scanned ion beam therapy

Author keywords

Quality assurance; Scanned ion beam; Treatment planning

Indexed keywords

APPLICATION PROGRAMS; DATA PRIVACY; GEOMETRY; HEAVY IONS; ION BEAMS; PHANTOMS; QUALITY ASSURANCE; SOFTWARE TESTING;

EID: 0343962206     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.599025     Document Type: Article
Times cited : (46)

References (20)
  • 3
    • 0031652741 scopus 로고    scopus 로고
    • Treatment planning for heavy ion irradiation
    • O. Jäkel and M. Krämer, "Treatment planning for heavy ion irradiation," Phys. Medica, Suppl. 1 14, 53-62 (1998).
    • (1998) Phys. Medica , vol.14 , Issue.SUPPL. 1 , pp. 53-62
    • Jäkel, O.1    Krämer, M.2
  • 4
    • 0342310130 scopus 로고    scopus 로고
    • Therapy planning for heavy ion irradiation
    • edited by U. Amaldi, B. Larsson, and Y. Lemoigne Elsevier, Amsterdam
    • M. Krämer and O. Jäkel, "Therapy planning for heavy ion irradiation," in Advances in Hadrontherapy, edited by U. Amaldi, B. Larsson, and Y. Lemoigne (Elsevier, Amsterdam, 1997), pp. 351-358.
    • (1997) Advances in Hadrontherapy , pp. 351-358
    • Krämer, M.1    Jäkel, O.2
  • 5
    • 0027287746 scopus 로고
    • Dreidimensionale bestrahlungsplanung -untersuchungen zur klinischen integration
    • G. Gademann et al., "Dreidimensionale Bestrahlungsplanung -Untersuchungen zur Klinischen Integration," Strahlenther. Onkol. 169, 159-167 (1993).
    • (1993) Strahlenther. Onkol. , vol.169 , pp. 159-167
    • Gademann, G.1
  • 7
    • 85027239322 scopus 로고
    • (International Electrotechnical Commission, Central Office, Geneva, 1989-10) identical to DIN 6847-4, Deutsches Institut für Normung, Beuth Verlag, Berlin
    • IEC Standard 976, Medical Electron Accelerators: Functional Performance Characteristics (International Electrotechnical Commission, Central Office, Geneva, 1989-10) (identical to DIN 6847-4, Deutsches Institut für Normung, Beuth Verlag, Berlin 1990-10).
    • (1990) Medical Electron Accelerators: Functional Performance Characteristics
  • 9
    • 0005497179 scopus 로고    scopus 로고
    • Deutsches Institut fäur Normung, Beuth Verlag, Berlin, Teil 5
    • DIN-Norm 6847-5, Medizinische Elektronenbeschleuniger-Anlagen (Deutsches Institut fäur Normung, Beuth Verlag, Berlin, 1998-01). Teil 5.
    • (1998) Medizinische Elektronenbeschleuniger-Anlagen
  • 12
    • 0031789601 scopus 로고    scopus 로고
    • AAPM radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning
    • B. Fraass, K. Doppke, M. Hunt, G. Kutcher, G. Starkschall, R. Stern, and J. Van Dyk, "AAPM Radiation Therapy Committee Task group 53: Quality assurance for clinical radiotherapy treatment planning," Med. Phys. 25, 1773-1829 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1773-1829
    • Fraass, B.1    Doppke, K.2    Hunt, M.3    Kutcher, G.4    Starkschall, G.5    Stern, R.6    Van Dyk, J.7
  • 15
    • 0345035258 scopus 로고    scopus 로고
    • A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    • C. P. Karger, O. Jákel, G. H. Hartmann, and P. Heeg, "A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions" Med. Phys. 26, 2125-2132 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2125-2132
    • Karger, C.P.1    Jákel, O.2    Hartmann, G.H.3    Heeg, P.4
  • 16
    • 0344655664 scopus 로고    scopus 로고
    • Determination of water absorbed dose in a carbon ion beam using thimble ionization chambers
    • G. H. Hartmann, O. Jäkel, P. Heeg, C. P. Karger, and A. Kriessbach, "Determination of water absorbed dose in a carbon ion beam using thimble ionization chambers," Phys. Med. Biol. 44, 1193-1206 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1193-1206
    • Hartmann, G.H.1    Jäkel, O.2    Heeg, P.3    Karger, C.P.4    Kriessbach, A.5
  • 17
    • 0031807135 scopus 로고    scopus 로고
    • The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power
    • B. Schaffner and E. Pedroni, "The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power," Phys. Med. Biol. 43, 1579-1592 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1579-1592
    • Schaffner, B.1    Pedroni, E.2
  • 18
    • 0031772165 scopus 로고    scopus 로고
    • Relationship between CT number and electron density, scatter angle, and nuclear reaction for hadron-therapy treatment planning
    • N. Matsufuji, H. Tomura, Y. Futami, H. Yamashita, A. Higashi, S. Minohara, M. Endo, and T. Kanai, "Relationship between CT number and electron density, scatter angle, and nuclear reaction for hadron-therapy treatment planning," Phys. Med. Biol. 43, 3261-3275 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3261-3275
    • Matsufuji, N.1    Tomura, H.2    Futami, Y.3    Yamashita, H.4    Higashi, A.5    Minohara, S.6    Endo, M.7    Kanai, T.8
  • 20
    • 0003438221 scopus 로고
    • Use of computers in external beam radiotherapy procedures with high-energy photons and electrons
    • ICRU, Bethesda, Maryland
    • ICRU Report 42, Use of Computers in External Beam Radiotherapy Procedures with High-Energy Photons and Electrons (ICRU, Bethesda, Maryland, 1987).
    • (1987) ICRU Report 42 , vol.42


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.