메뉴 건너뛰기




Volumn 19, Issue 1, 2009, Pages 110-120

A noncontrast-enhanced pulse sequence optimized to visualize human peripheral vessels

Author keywords

MR angiography; MR imaging; MR venography; Pulse sequence; Vessels

Indexed keywords

ADULT; ARTICLE; CASE REPORT; CONTROLLED STUDY; DEEP VEIN THROMBOSIS; FEMALE; HUMAN; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PERIPHERAL CIRCULATION; PHLEBOGRAPHY; PRIORITY JOURNAL; PROCESS OPTIMIZATION; SIGNAL NOISE RATIO; SPATIAL ORIENTATION; SYNOVIAL FLUID; VARICOSIS;

EID: 59249088274     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-008-1113-8     Document Type: Article
Times cited : (13)

References (27)
  • 1
    • 0024383809 scopus 로고
    • Three-dimensional time-of-flight magnetic resonance angiography using spin saturation
    • Dumoulin CL, Cline HE, Souza SP, Wagle WA, Walker MF (1989) Three-dimensional time-of-flight magnetic resonance angiography using spin saturation. Magn Reson Med 11(1):35-46
    • (1989) Magn Reson Med , vol.11 , Issue.1 , pp. 35-46
    • Dumoulin, C.L.1    Cline, H.E.2    Souza, S.P.3    Wagle, W.A.4    Walker, M.F.5
  • 3
    • 0025163595 scopus 로고
    • Extracranial carotid arteries: Evaluation with "black-blood" MR angiography
    • Edelman RR, Mattle HP, Wallner B (1990) Extracranial carotid arteries: evaluation with "black-blood" MR angiography. Radiology 177:45-50
    • (1990) Radiology , vol.177 , pp. 45-50
    • Edelman, R.R.1    Mattle, H.P.2    Wallner, B.3
  • 4
    • 0028351567 scopus 로고
    • Gadolinium-enhanced MR aortography
    • Prince MR (1994) Gadolinium-enhanced MR aortography. Radiology 191:155-64
    • (1994) Radiology , vol.191 , pp. 155-164
    • Prince, M.R.1
  • 5
    • 0034111614 scopus 로고    scopus 로고
    • Pelvic and lower extremity veins: Contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience
    • Ruehm SG, Wiesner W, Debatin JF (2000) Pelvic and lower extremity veins: contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience. Radiology 215:421-427
    • (2000) Radiology , vol.215 , pp. 421-427
    • Ruehm, S.G.1    Wiesner, W.2    Debatin, J.F.3
  • 7
    • 0037371628 scopus 로고    scopus 로고
    • Deep venous thrombosis: Diagnosis by using venous enhanced subtracted peak arterial MR venography versus conventional venography
    • Fraser DGW, Moody AR, Davidson IR, Martel AL, Morgan PS (2003) Deep venous thrombosis: Diagnosis by using venous enhanced subtracted peak arterial MR venography versus conventional venography. Radiology 226:812-820
    • (2003) Radiology , vol.226 , pp. 812-820
    • Fraser, D.G.W.1    Moody, A.R.2    Davidson, I.R.3    Martel, A.L.4    Morgan, P.S.5
  • 9
    • 4544338304 scopus 로고    scopus 로고
    • Gadolinium-based contrast media may be nephrotoxic even at approved doses
    • Thomsen HS (2004) Gadolinium-based contrast media may be nephrotoxic even at approved doses. Eur Radiol 14(9):1654-1656
    • (2004) Eur Radiol , vol.14 , Issue.9 , pp. 1654-1656
    • Thomsen, H.S.1
  • 11
    • 0031884958 scopus 로고    scopus 로고
    • Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 2 T
    • Duerk JL, Lewin JS, Wendt M, Petersilge C (1998) Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 2 T. J Magn Reson Imaging 8(1):203-208
    • (1998) J Magn Reson Imaging , vol.8 , Issue.1 , pp. 203-208
    • Duerk, J.L.1    Lewin, J.S.2    Wendt, M.3    Petersilge, C.4
  • 12
    • 21244491945 scopus 로고    scopus 로고
    • Analysis and compensation of eddy currents in balanced SSFP
    • Bieri O, Markl M, Scheffler K (2005) Analysis and compensation of eddy currents in balanced SSFP. Magn Reson Med 54:129-137
    • (2005) Magn Reson Med , vol.54 , pp. 129-137
    • Bieri, O.1    Markl, M.2    Scheffler, K.3
  • 13
    • 0025232486 scopus 로고
    • Steady-state free precession imaging in the presence of motion: Application for improved visualization of the cerebrospinal fluid
    • Haacke EM, Wielopolski PA, Tkach JA, Modic MT (1990) Steady-state free precession imaging in the presence of motion: Application for improved visualization of the cerebrospinal fluid. Radiology 175:545-552
    • (1990) Radiology , vol.175 , pp. 545-552
    • Haacke, E.M.1    Wielopolski, P.A.2    Tkach, J.A.3    Modic, M.T.4
  • 14
    • 0034979158 scopus 로고    scopus 로고
    • Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study
    • Barkhausen J, Quick HH, Lauenstein T, Goyen M, Ruehm SG, Laub G, Debatin JF, Ladd ME (2001) Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study. Radiology 220(1):252-256
    • (2001) Radiology , vol.220 , Issue.1 , pp. 252-256
    • Barkhausen, J.1    Quick, H.H.2    Lauenstein, T.3    Goyen, M.4    Ruehm, S.G.5    Laub, G.6    Debatin, J.F.7    Ladd, M.E.8
  • 15
    • 0036206965 scopus 로고    scopus 로고
    • Thoracic aortic dissection and aneurysm: Evaluation with nonenhanced true FISP MR angiography in less than 4 minutes
    • Pereles FS, McCarthy RM, Baskaran V, Carr JC, Kapoor V, Krupinski EA, Finn JP (2002) Thoracic aortic dissection and aneurysm: Evaluation with nonenhanced true FISP MR angiography in less than 4 minutes. Radiology 223(1):270-274
    • (2002) Radiology , vol.223 , Issue.1 , pp. 270-274
    • Pereles, F.S.1    McCarthy, R.M.2    Baskaran, V.3    Carr, J.C.4    Kapoor, V.5    Krupinski, E.A.6    Finn, J.P.7
  • 16
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • Scheffler K, Lehnhardt S (2003) Principles and applications of balanced SSFP techniques. Eur Radiol 13(11):2409-2418
    • (2003) Eur Radiol , vol.13 , Issue.11 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 17
    • 0034839555 scopus 로고    scopus 로고
    • 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries
    • Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D (2001) 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries. Magn Reson Med 46(3):494-502
    • (2001) Magn Reson Med , vol.46 , Issue.3 , pp. 494-502
    • Deshpande, V.S.1    Shea, S.M.2    Laub, G.3    Simonetti, O.P.4    Finn, J.P.5    Li, D.6
  • 23
    • 0023948465 scopus 로고
    • Deep venous thrombosis: Is contrast venography still the diagnostic "gold standard"?
    • Redman HC (1988) Deep venous thrombosis: Is contrast venography still the diagnostic "gold standard"? Radiology 168(1):277-278
    • (1988) Radiology , vol.168 , Issue.1 , pp. 277-278
    • Redman, H.C.1
  • 24
    • 0029682454 scopus 로고    scopus 로고
    • Detection of deep venous thrombosis: Prospective comparison of MR imaging and sonography
    • Evans AJ, Sostman HD, Witty LA et al (1996) Detection of deep venous thrombosis: Prospective comparison of MR imaging and sonography. J Magn Reson Imaging 1:44-51
    • (1996) J Magn Reson Imaging , vol.1 , pp. 44-51
    • Evans, A.J.1    Sostman, H.D.2    Witty, L.A.3
  • 26
    • 34548449828 scopus 로고    scopus 로고
    • Technical requirements, biophysical considerations and protocol optimization with magnetic resonance angiography using blood-pool agents
    • Rohrer M, Geerts-Ossevoort L, Laub G (2007) Technical requirements, biophysical considerations and protocol optimization with magnetic resonance angiography using blood-pool agents. Eur Radiol Suppl 17:B7-B12
    • (2007) Eur Radiol Suppl , vol.17
    • Rohrer, M.1    Geerts-Ossevoort, L.2    Laub, G.3
  • 27
    • 34548433459 scopus 로고    scopus 로고
    • Application of blood-pool agents in visualization of peripheral vessels
    • Giovagnoni A, Catalano C (2007) Application of blood-pool agents in visualization of peripheral vessels. Eur Radiol Suppl 17:B18-B23
    • (2007) Eur Radiol Suppl , vol.17
    • Giovagnoni, A.1    Catalano, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.