메뉴 건너뛰기




Volumn 50, Issue 1, 2003, Pages 210-213

Fat-suppressed steady-state free precession imaging using phase detection

Author keywords

Angiography; Fat suppression; SSFP; Steady state; TrueFISP

Indexed keywords

ANGIOGRAPHY; SIGNAL DETECTION;

EID: 0037924531     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10488     Document Type: Article
Times cited : (100)

References (21)
  • 1
    • 0000369227 scopus 로고
    • Steady-state free precession in nuclear magnetic resonance
    • Carr HY. Steady-state free precession in nuclear magnetic resonance, Phys Rev 1958;112:1693-1701.
    • (1958) Phys Rev , vol.112 , pp. 1693-1701
    • Carr, H.Y.1
  • 6
    • 0037306841 scopus 로고    scopus 로고
    • Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation
    • Reeder SB, Alley MT, Pelc NJ, Gold GE. Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation. AJR Am J Roentgenol 2003;180:357-362.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 357-362
    • Reeder, S.B.1    Alley, M.T.2    Pelc, N.J.3    Gold, G.E.4
  • 7
    • 0035009703 scopus 로고    scopus 로고
    • Magnetization preparation during the steady-state: Fat-saturated 3D true FISP
    • Scheffler K, Heid O, Hennig J. Magnetization preparation during the steady-state: fat-saturated 3D true FISP. Magn Reson Med 2001;45: 1075-1080.
    • (2001) Magn Reson Med , vol.45 , pp. 1075-1080
    • Scheffler, K.1    Heid, O.2    Hennig, J.3
  • 10
    • 0034956696 scopus 로고    scopus 로고
    • Characterization and reduction of the transient response in steady-state MR imaging
    • Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG. Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 2001;46:149-158.
    • (2001) Magn Reson Med , vol.46 , pp. 149-158
    • Hargreaves, B.A.1    Vasanawala, S.S.2    Pauly, J.M.3    Nishimura, D.G.4
  • 11
    • 0023872880 scopus 로고
    • An analysis of fast imaging sequences with steady-state transverse magnetization refocusing
    • Zur Y, Stokar S, Bendel P. An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 1988;6:175-193.
    • (1988) Magn Reson Med , vol.6 , pp. 175-193
    • Zur, Y.1    Stokar, S.2    Bendel, P.3
  • 12
    • 0000440460 scopus 로고
    • Signal intensity in fast NMR imaging with short repetition times
    • Buxton RB, Fisel CR, Chien D, Brady TJ. Signal intensity in fast NMR imaging with short repetition times. J Magn Reson 1989;83:576-585.
    • (1989) J Magn Reson , vol.83 , pp. 576-585
    • Buxton, R.B.1    Fisel, C.R.2    Chien, D.3    Brady, T.J.4
  • 13
    • 33749622370 scopus 로고
    • Spin echoes
    • Hahn EL. Spin echoes. Phys Rev 1950;80:580-594.
    • (1950) Phys Rev , vol.80 , pp. 580-594
    • Hahn, E.L.1
  • 14
    • 0037311485 scopus 로고    scopus 로고
    • Is TrueFISP a gradient-echo or spin-echo sequence?
    • Scheffler K, Hennig J. Is TrueFISP a gradient-echo or spin-echo sequence? Magn Reson Med 2003;49:395-397.
    • (2003) Magn Reson Med , vol.49 , pp. 395-397
    • Scheffler, K.1    Hennig, J.2
  • 15
    • 0033472075 scopus 로고    scopus 로고
    • A pictorial description of steady-states in rapid magnetic resonance imaging
    • Scheffler K. A pictorial description of steady-states in rapid magnetic resonance imaging. Concepts Magn Reson 1999;11:291-304.
    • (1999) Concepts Magn Reson , vol.11 , pp. 291-304
    • Scheffler, K.1
  • 17
    • 0035180571 scopus 로고    scopus 로고
    • Real-time cardiac cine imaging with SPIDER: Steady-state projection imaging with dynamic echo-train readout
    • Larson AC, Simonetti OP. Real-time cardiac cine imaging with SPIDER: steady-state projection imaging with dynamic echo-train readout. Magn Reson Med 2001;46:1059-1066.
    • (2001) Magn Reson Med , vol.46 , pp. 1059-1066
    • Larson, A.C.1    Simonetti, O.P.2
  • 19
    • 0036892338 scopus 로고    scopus 로고
    • FIESTA-ET: High-resolution cardiac imaging using echo-planar steady-state free precession
    • Slavin GS, Saranathan M. FIESTA-ET: high-resolution cardiac imaging using echo-planar steady-state free precession. Magn Reson Med 2002; 48:934-941.
    • (2002) Magn Reson Med , vol.48 , pp. 934-941
    • Slavin, G.S.1    Saranathan, M.2
  • 21
    • 0037605811 scopus 로고    scopus 로고
    • Rapid three-dimensional imaging with the hourglass trajectory
    • Honolulu
    • Thedens DR. Rapid three-dimensional imaging with the hourglass trajectory. In: Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, 2002. p 2360.
    • (2002) Proceedings of the 10th Annual Meeting of ISMRM , pp. 2360
    • Thedens, D.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.