메뉴 건너뛰기




Volumn 36, Issue 2, 2009, Pages 662-671

A new single acquisition, two-image difference method for determining MR image SNR

Author keywords

Image quality; MRI; SNR

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMAGE SEGMENTATION; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; SIGNAL TO NOISE RATIO;

EID: 59249086236     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3036118     Document Type: Article
Times cited : (17)

References (20)
  • 3
    • 0027453763 scopus 로고
    • The use of power images to perform quantitative analysis on low SNR MR images
    • A. J. Miller and P. M. Joseph, " The use of power images to perform quantitative analysis on low SNR MR images.," Magn. Reson. Imaging 11, 1051-1056 (1993).
    • (1993) Magn. Reson. Imaging , vol.11 , pp. 1051-1056
    • Miller, A.J.1    Joseph, P.M.2
  • 4
    • 0027317240 scopus 로고
    • An unbiased signal to noise ratio measure for magnetic resonance images
    • G. McGibney and M. R. Smith, " An unbiased signal to noise ratio measure for magnetic resonance images.," Med. Phys. 20, 1077-1078 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1077-1078
    • McGibney, G.1    Smith, M.R.2
  • 5
    • 0030425801 scopus 로고    scopus 로고
    • Quantification and improvement of the signal-to-noise ratio in a magnetic resonance image acquisition procedure
    • J. Sijbers, P. Scheunders, N. Bonnet, D. Van Dyck, and E. Raman, " Quantification and improvement of the signal-to-noise ratio in a magnetic resonance image acquisition procedure.," Magn. Reson. Imaging 14 (10), 1157-1163 (1996).
    • (1996) Magn. Reson. Imaging , vol.14 , Issue.10 , pp. 1157-1163
    • Sijbers, J.1    Scheunders, P.2    Bonnet, N.3    Van Dyck, D.4    Raman, E.5
  • 6
    • 0030726766 scopus 로고    scopus 로고
    • Signal to noise measurements in magnitude images from NMR phased arrays
    • C. D. Constantinides, E. Atalar, and E. R. McVeigh, " Signal to noise measurements in magnitude images from NMR phased arrays.," Magn. Reson. Med. 38, 852-857 (1997).
    • (1997) Magn. Reson. Med. , vol.38 , pp. 852-857
    • Constantinides, C.D.1    Atalar, E.2    McVeigh, E.R.3
  • 7
  • 8
    • 0032800940 scopus 로고    scopus 로고
    • A comparison of two methods for measuring the signal to noise ratio on MR images
    • M. J. Firbank, A. Coulthard, R. M. Harrison, and E. D. Williams, " A comparison of two methods for measuring the signal to noise ratio on MR images.," Phys. Med. Biol. 44, N261-N264 (1999).
    • (1999) Phys. Med. Biol. , vol.44
    • Firbank, M.J.1    Coulthard, A.2    Harrison, R.M.3    Williams, E.D.4
  • 9
    • 85027221762 scopus 로고    scopus 로고
    • National Manufacturers Electrical Association, MS1- determination of signal-to-noise ratio (SNR) in diagnostic magnetic resonance images, NEMA, Washington, DC.
    • National Manufacturers Electrical Association, MS1- 2001 determination of signal-to-noise ratio (SNR) in diagnostic magnetic resonance images, NEMA, Washington, DC.
    • (2001)
  • 10
    • 0021254150 scopus 로고
    • A signal to noise calibration procedure for NMR imaging systems
    • W. A. Edelstein, P. A. Bottomley, and L. M. Pfeifer, " A signal to noise calibration procedure for NMR imaging systems.," Med. Phys. 11, 180-185 (1984).
    • (1984) Med. Phys. , vol.11 , pp. 180-185
    • Edelstein, W.A.1    Bottomley, P.A.2    Pfeifer, L.M.3
  • 11
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • O. Dietrich, J. G. Raya, S. B. Reeder, M. F. Reiser, and S. O. Schoenberg, " Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters.," J. Magn. Reson Imaging 26, 375-385 (2007).
    • (2007) J. Magn. Reson Imaging , vol.26 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Reiser, M.F.4    Schoenberg, S.O.5
  • 12
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • R. M. Henkelman, " Measurement of signal intensities in the presence of noise in MR images.," Med. Phys. 12, 232-233 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 13
    • 77956301240 scopus 로고    scopus 로고
    • A new single acquisition, two-image difference method for determining MR image SNR
    • M. C. Steckner, " A new single acquisition, two-image difference method for determining MR image SNR.," International Society of Magnetic Resonance in Medicine, 2006, p. 2398.
    • (2006) International Society of Magnetic Resonance in Medicine , pp. 2398
    • Steckner, M.C.1
  • 14
    • 85027239975 scopus 로고    scopus 로고
    • Philips Medical Systems, Best, The Netherlands (personal communication).
    • Miha Fuderer, Philips Medical Systems, Best, The Netherlands (personal communication).
    • Fuderer, M.1
  • 15
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • K. P. Pruessmann, " SENSE: Sensitivity encoding for fast MRI.," Magn. Reson. Med. 42 (5), 952-962 (1999).
    • (1999) Magn. Reson. Med. , vol.42 , Issue.5 , pp. 952-962
    • Pruessmann, K.P.1
  • 16
    • 34247196111 scopus 로고    scopus 로고
    • Automatic estimation of the noise variance from the histogram of a magnetic resonance image
    • J. Sijbers, D. Poot, A. J. den Dekker, and W. Pintjens, " Automatic estimation of the noise variance from the histogram of a magnetic resonance image.," Phys. Med. Biol. 52, 1335-1348 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , pp. 1335-1348
    • Sijbers, J.1    Poot, D.2    Den Dekker, A.J.3    Pintjens, W.4
  • 17
    • 27644527486 scopus 로고    scopus 로고
    • Image reconstruction in SNR units: A general method for SNR measurement
    • P. Kellman and E. R. McVeigh, " Image reconstruction in SNR units: A general method for SNR measurement.," Magn. Reson. Med. 54, 1439-1447 (2005).
    • (2005) Magn. Reson. Med. , vol.54 , pp. 1439-1447
    • Kellman, P.1    McVeigh, E.R.2
  • 19
    • 0032951953 scopus 로고    scopus 로고
    • Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging
    • D. K. Sodickson, " Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging.," Magn. Reson. Med. 41 (5), 1009-1022 (1999).
    • (1999) Magn. Reson. Med. , vol.41 , Issue.5 , pp. 1009-1022
    • Sodickson, D.K.1
  • 20
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • M. A. Griswold, " Generalized autocalibrating partially parallel acquisitions (GRAPPA).," Magn. Reson. Med. 47 (6), 1202-1210 (2002).
    • (2002) Magn. Reson. Med. , vol.47 , Issue.6 , pp. 1202-1210
    • Griswold, M.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.