메뉴 건너뛰기




Volumn 4, Issue 4, 2008, Pages 348-354

Computer-assisted implant surgery; a flapless surgical/immediate loaded approach with 1 year follow-up

Author keywords

Computer assisted implantology; Dental implants; Flapless surgery; Immediate loading; Prosthodontic driven implant placement

Indexed keywords

BONE; COMPUTERIZED TOMOGRAPHY; QUALITY CONTROL;

EID: 59049087939     PISSN: 14785951     EISSN: 1478596X     Source Type: Journal    
DOI: 10.1002/rcs.219     Document Type: Article
Times cited : (12)

References (28)
  • 1
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark P-I, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plastic Reconstr Surg 1977; 16: 1-132.
    • (1977) Scand J Plastic Reconstr Surg , vol.16 , pp. 1-132
    • Brånemark, P.-I.1    Hansson, B.O.2    Adell, R.3
  • 2
    • 0031151465 scopus 로고    scopus 로고
    • Immediate loading of Brånemark implants in edentulous mandibles. A preliminary report
    • Balshi TJ, Wolfinger GJ. Immediate loading of Brånemark implants in edentulous mandibles. A preliminary report. Implant Dentistry 1997; 6: 83-88.
    • (1997) Implant Dentistry , vol.6 , pp. 83-88
    • Balshi, T.J.1    Wolfinger, G.J.2
  • 3
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: Results on 226 consecutive cases
    • Chiapasco M, Gatti C, Rossi E, et al. Implant-retained mandibular overdentures with immediate loading: results on 226 consecutive cases. Clin Oral Implant Res 1997; 8: 48-57.
    • (1997) Clin Oral Implant Res , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3
  • 4
    • 0031178276 scopus 로고    scopus 로고
    • Ten-year results for Branemark implants immediately loaded with fixed prostheses at implant placement
    • Schnitman PA. Ten-year results for Branemark implants immediately loaded with fixed prostheses at implant placement. Int J Oral Maxillofac Implants 1997; 12: 495-503.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 495-503
    • Schnitman, P.A.1
  • 5
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches. Ten consecutive case reports with 1 to 5 year data
    • Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches. Ten consecutive case reports with 1 to 5 year data. Int J Oral Maxillofac Implants 1997; 12: 319-324.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 6
    • 0034186403 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: A prospective study of ITI implants
    • Gatti C, Haefliger W, Chiapasco M. Implant-retained mandibular overdentures with immediate loading: a prospective study of ITI implants. Int J Oral Maxillofac Implants 2000; 15: 383-388.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 383-388
    • Gatti, C.1    Haefliger, W.2    Chiapasco, M.3
  • 7
    • 0034183762 scopus 로고    scopus 로고
    • Immediate loading of implants in partially and fully edentulous jaws. A series of 27 case reports
    • Jaffin RA, Kumar A, Berman CL. Immediate loading of implants in partially and fully edentulous jaws. A series of 27 case reports. J Periodontol 2000; 71: 833-838.
    • (2000) J Periodontol , vol.71 , pp. 833-838
    • Jaffin, R.A.1    Kumar, A.2    Berman, C.L.3
  • 8
    • 0034574209 scopus 로고    scopus 로고
    • Immediate function of Branemark implants in the esthetic zone: A retrospective clinical study with 6 months to 4 years of follow-up
    • Malo P, Rangert B, Dvarsater L. Immediate function of Branemark implants in the esthetic zone: a retrospective clinical study with 6 months to 4 years of follow-up. Clin Implant Dentistry Rel Res 2000; 2: 138-146.
    • (2000) Clin Implant Dentistry Rel Res , vol.2 , pp. 138-146
    • Malo, P.1    Rangert, B.2    Dvarsater, L.3
  • 9
    • 12244306956 scopus 로고    scopus 로고
    • Early and immediate restoration and loading of implants in completely edentulous patients
    • Chiapasco M. Early and immediate restoration and loading of implants in completely edentulous patients. Int J Oral Maxillofac Implants 2004; 19: 76-91.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 76-91
    • Chiapasco, M.1
  • 10
    • 0027244789 scopus 로고
    • Early results from reconstruction ofseverely atrophic (Class VI) maxillae by immediate endosseous implants in conjunction with bone grafting and Le Fort I osteotomy
    • Isaksson S, Ekfeld A, Alberius P, et al. Early results from reconstruction ofseverely atrophic (Class VI) maxillae by immediate endosseous implants in conjunction with bone grafting and Le Fort I osteotomy. Int J Oral Maxillofac Surg 1993; 22: 144-148.
    • (1993) Int J Oral Maxillofac Surg , vol.22 , pp. 144-148
    • Isaksson, S.1    Ekfeld, A.2    Alberius, P.3
  • 11
    • 2542433556 scopus 로고    scopus 로고
    • Maxillofacial application of implants in conjunction with bone grafts
    • Lang NP, Karring T, Lindhe J eds, Quintessenz Verlag: Berlin
    • Weingart D, Petrin G. Maxillofacial application of implants in conjunction with bone grafts. In Proceedings of the 3rd EuropeanWorkshop on Periodontology - Implant Dentistry, Lang NP, Karring T, Lindhe J (eds). Quintessenz Verlag: Berlin, 1999; 544-556.
    • (1999) Proceedings of the 3rd EuropeanWorkshop on Periodontology - Implant Dentistry , pp. 544-556
    • Weingart, D.1    Petrin, G.2
  • 12
    • 0036516691 scopus 로고    scopus 로고
    • Flapless implant surgery: A 10-year clinical retrospective analysis
    • Campelo LD, Camara JR. Flapless implant surgery: A 10-year clinical retrospective analysis. Int J Oral Maxillofac Implants 2002; 17: 271-276.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 271-276
    • Campelo, L.D.1    Camara, J.R.2
  • 13
    • 0032201306 scopus 로고    scopus 로고
    • Placement of dental implants without flap surgery: A clinical report
    • al-Ansari BH, Morris RR. Placement of dental implants without flap surgery: a clinical report. Int J Oral Maxillofac Implants 1998; 13: 861-865.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 861-865
    • al-Ansari, B.H.1    Morris, R.R.2
  • 14
    • 14844342688 scopus 로고    scopus 로고
    • Intraoperative computerized navigation for flapless implant surgery and immediate loading in the edentulous mandible
    • Casap N, Tarazi E, Wexler A, et al. Intraoperative computerized navigation for flapless implant surgery and immediate loading in the edentulous mandible. Int J Oral Maxillofac Implants 2005; 20: 92-98.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 92-98
    • Casap, N.1    Tarazi, E.2    Wexler, A.3
  • 15
    • 0029303274 scopus 로고
    • Bending overload and implant fracture: A retrospective clinical analysis
    • Rangert B, KroghPH, LangerB, et al. Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1995; 10: 326-334.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 326-334
    • Rangert, B.1    Krogh, P.H.2    Langer, B.3
  • 16
    • 0032140178 scopus 로고    scopus 로고
    • The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures
    • Hobkirk JA, Havthoulas TK. The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures. J Prosthet Dent 1998; 80: 169-174.
    • (1998) J Prosthet Dent , vol.80 , pp. 169-174
    • Hobkirk, J.A.1    Havthoulas, T.K.2
  • 17
    • 0141575639 scopus 로고    scopus 로고
    • Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging
    • Kopp KC, Koslow AH, Abdo OS. Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. J Prosthet Dent 2003; 89: 611-615.
    • (2003) J Prosthet Dent , vol.89 , pp. 611-615
    • Kopp, K.C.1    Koslow, A.H.2    Abdo, O.S.3
  • 18
    • 0033140345 scopus 로고    scopus 로고
    • Biomechanical and functional behavior of implants
    • Stanford CM. Biomechanical and functional behavior of implants. Adv Dent Res 1999; 13: 88-92.
    • (1999) Adv Dent Res , vol.13 , pp. 88-92
    • Stanford, C.M.1
  • 19
    • 38149137150 scopus 로고    scopus 로고
    • The effectiveness of immediate, early, and conventional loading of dental implants: A Cochrane systematic review of randomized controlled clinical trials
    • Dula K, Mini R van der Stelt P, et al. The effectiveness of immediate, early, and conventional loading of dental implants: a Cochrane systematic review of randomized controlled clinical trials. Int J Oral Maxillofac Implants 2007; 22: 893-904.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 893-904
    • Dula, K.1    Mini, R.2    van der Stelt, P.3
  • 20
    • 0344364562 scopus 로고    scopus 로고
    • Preoperative radiologic planning of implants in compromised patients
    • Jacobs R. Preoperative radiologic planning of implants in compromised patients. Periodontology 2003; 33: 12-25.
    • (2003) Periodontology , vol.33 , pp. 12-25
    • Jacobs, R.1
  • 21
    • 0033742261 scopus 로고    scopus 로고
    • Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography
    • Besimo CE, Lambrecht JT, Guindy JS. Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography. Dentomaxillofac Radiol 2000; 29(1): 46-51.
    • (2000) Dentomaxillofac Radiol , vol.29 , Issue.1 , pp. 46-51
    • Besimo, C.E.1    Lambrecht, J.T.2    Guindy, J.S.3
  • 22
    • 0141608169 scopus 로고    scopus 로고
    • Computer-assisted implant placement. A case report: Treatment of the mandible
    • Tardieu PB, Vrielinck L, Escolano E. Computer-assisted implant placement. A case report: treatment of the mandible. Int J Oral Maxillofac Implants 2003; 18: 599-604.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 599-604
    • Tardieu, P.B.1    Vrielinck, L.2    Escolano, E.3
  • 23
    • 41949113148 scopus 로고    scopus 로고
    • Flapless implant surgery: Review of the literature and report of two cases with computer-guided surgical approach
    • Azari A, Nikzad S. Flapless implant surgery: review of the literature and report of two cases with computer-guided surgical approach. J Oral Maxillofac Surg 2008; 66: 1015-1021.
    • (2008) J Oral Maxillofac Surg , vol.66 , pp. 1015-1021
    • Azari, A.1    Nikzad, S.2
  • 24
    • 45949085744 scopus 로고    scopus 로고
    • Computer-assisted implantology: Historical background and potential outcomes - a review
    • Azari A, Nikzad S. Computer-assisted implantology: historical background and potential outcomes - a review. Int J Med Robotics Comput Assist Surg 2008; 4: 95-104.
    • (2008) Int J Med Robotics Comput Assist Surg , vol.4 , pp. 95-104
    • Azari, A.1    Nikzad, S.2
  • 25
    • 0036367728 scopus 로고    scopus 로고
    • Precision surgical template for implant placement: A new systematic approach
    • Wat PY, Chow TW, Luk HW, et al. Precision surgical template for implant placement: a new systematic approach. Clin Implant Dent Relat 2002; 4(2): 88-92.
    • (2002) Clin Implant Dent Relat , vol.4 , Issue.2 , pp. 88-92
    • Wat, P.Y.1    Chow, T.W.2    Luk, H.W.3
  • 26
    • 0041758383 scopus 로고    scopus 로고
    • The use of lipiodol in spiral tomography for dental implant imaging
    • Siu AS, Li TK, Chu FC, et al. The use of lipiodol in spiral tomography for dental implant imaging. Implant Dent 2003; 12(1): 35-40.
    • (2003) Implant Dent , vol.12 , Issue.1 , pp. 35-40
    • Siu, A.S.1    Li, T.K.2    Chu, F.C.3
  • 27


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.