메뉴 건너뛰기




Volumn 17, Issue 2, 2009, Pages 179-183

Does stress shielding occur with the use of long-stem prosthesis in total knee arthroplasty?

Author keywords

Arthroplasty; Bone mineral density; Knee; Long stem; Stress shielding

Indexed keywords

AGED; ARTICLE; BONE DENSITY; FEMALE; HUMAN; KNEE ARTHROPLASTY; KNEE OSTEOARTHRITIS; KNEE PROSTHESIS; MALE; MECHANICAL STRESS; METHODOLOGY; PHOTON ABSORPTIOMETRY; PROSTHESIS; RADIOGRAPHY; RETROSPECTIVE STUDY; TIBIA; TREATMENT OUTCOME;

EID: 58849158703     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-008-0649-0     Document Type: Article
Times cited : (8)

References (35)
  • 2
    • 0030787629 scopus 로고    scopus 로고
    • Periprosthetic bone remodeling after cementless total hip replacement
    • 4
    • KC Ang S Das De JCH Goh SL Low K Bose 1997 Periprosthetic bone remodeling after cementless total hip replacement J Bone Joint Surg Am 79 4 675 679
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 675-679
    • Ang, K.C.1    De, D.S.2    Goh, J.C.H.3    Low, S.L.4    Bose, K.5
  • 4
    • 0026519501 scopus 로고
    • Producing and avoiding stress shielding. Laboratory and clinical observations of non-cemented total hip arthroplasty
    • JD Bobyn ES Mortimer AH Glassman CA Engh JE Miller CE Brooks 1992 Producing and avoiding stress shielding. Laboratory and clinical observations of non-cemented total hip arthroplasty Clin Orthop 274 79 96
    • (1992) Clin Orthop , vol.274 , pp. 79-96
    • Bobyn, J.D.1    Mortimer, E.S.2    Glassman, A.H.3    Engh, C.A.4    Miller, J.E.5    Brooks, C.E.6
  • 5
    • 0022498343 scopus 로고
    • The influence of tibial component intra-medullary stems and implant cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty. An invitro study
    • RB Bourne JB Finlay 1986 The influence of tibial component intra-medullary stems and implant cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty. An invitro study Clin Orthop 208 95 99
    • (1986) Clin Orthop , vol.208 , pp. 95-99
    • Bourne, R.B.1    Finlay, J.B.2
  • 6
    • 0026795145 scopus 로고
    • A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty
    • 7
    • CA Engh TF McGovern JD Bobyn WH Harris 1992 A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty J Bone Joint Surg Am 74 7 1009 1120
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1009-1120
    • Engh, C.A.1    McGovern, T.F.2    Bobyn, J.D.3    Harris, W.H.4
  • 8
    • 1842405951 scopus 로고    scopus 로고
    • Treatment of major defects of bone with bulk allografts and stemmed components during total knee arthroplasty
    • 7
    • GA Engh PJ Herzwurm NL Parks 1997 Treatment of major defects of bone with bulk allografts and stemmed components during total knee arthroplasty J Bone Joint Surg Am 79 7 1030 1039
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1030-1039
    • Engh, G.A.1    Herzwurm, P.J.2    Parks, N.L.3
  • 9
    • 0024950156 scopus 로고
    • The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system
    • FC Ewald 1989 The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system Clin Orthop 248 9 12
    • (1989) Clin Orthop , vol.248 , pp. 9-12
    • Ewald, F.C.1
  • 11
    • 0024314577 scopus 로고
    • The biology of osteoarthritis
    • D Hammerman 1989 The biology of osteoarthritis N Engl J Med 320 1322 1330
    • (1989) N Engl J Med , vol.320 , pp. 1322-1330
    • Hammerman, D.1
  • 12
    • 0030850523 scopus 로고    scopus 로고
    • Intra-articular tibial plateau stress fracture associated with osteoarthrosis and valgus knee deformity
    • 6
    • D Hendel GJ Velan M Weisbort 1997 Intra-articular tibial plateau stress fracture associated with osteoarthrosis and valgus knee deformity J Arthroplasty 12 6 713 715
    • (1997) J Arthroplasty , vol.12 , pp. 713-715
    • Hendel, D.1    Velan, G.J.2    Weisbort, M.3
  • 14
    • 0020510446 scopus 로고
    • The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements
    • 5
    • JN Insall RW Hood LB Flawn DJ Sullivan 1983 The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements J Bone Joint Surg Am 65 5 619 628
    • (1983) J Bone Joint Surg Am , vol.65 , pp. 619-628
    • Insall, J.N.1    Hood, R.W.2    Flawn, L.B.3    Sullivan, D.J.4
  • 15
    • 0020445303 scopus 로고
    • The posterior stabilized condylar prosthesis: A modification of the total condylar design: Two to four-year clinical experience
    • 9
    • JN Insall PF Lachiewicz AH Burstein 1982 The posterior stabilized condylar prosthesis: a modification of the total condylar design: two to four-year clinical experience J Bone Joint Surg Am 64 9 1317 1323
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 1317-1323
    • Insall, J.N.1    Lachiewicz, P.F.2    Burstein, A.H.3
  • 17
    • 0018346367 scopus 로고
    • The total condylar knee prosthesis: A report of two hundred and twenty cases
    • 2
    • J Insall WN Scott CS Ranawat 1979 The total condylar knee prosthesis: a report of two hundred and twenty cases J Bone Joint Surg Am 61 2 173 180
    • (1979) J Bone Joint Surg Am , vol.61 , pp. 173-180
    • Insall, J.1    Scott, W.N.2    Ranawat, C.S.3
  • 18
    • 0034095675 scopus 로고    scopus 로고
    • Changes in bone mineral density of the proximal femur after total knee arthroplasty
    • 4
    • Y Ishii K Yagisawa Y Ikezawa 2000 Changes in bone mineral density of the proximal femur after total knee arthroplasty J Arthroplasty 15 4 519 522
    • (2000) J Arthroplasty , vol.15 , pp. 519-522
    • Ishii, Y.1    Yagisawa, K.2    Ikezawa, Y.3
  • 19
    • 0034878493 scopus 로고    scopus 로고
    • The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty
    • 6
    • LM Jazrawi B Bai FJ Kummer R Hiebert SA Stuchin 2001 The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty J Arthroplasty 16 6 759 767
    • (2001) J Arthroplasty , vol.16 , pp. 759-767
    • Jazrawi, L.M.1    Bai, B.2    Kummer, F.J.3    Hiebert, R.4    Stuchin, S.A.5
  • 20
    • 0033818714 scopus 로고    scopus 로고
    • The effect of pre-operative bone quality on the fixation of the tibial component in total knee arthroplasty
    • 6
    • MG Li KG Nilsson 2000 The effect of pre-operative bone quality on the fixation of the tibial component in total knee arthroplasty J Arthroplasty 15 6 744 753
    • (2000) J Arthroplasty , vol.15 , pp. 744-753
    • Li, M.G.1    Nilsson, K.G.2
  • 21
    • 0035145732 scopus 로고    scopus 로고
    • Changes in bone density after cemented total knee arthroplasty. Influence of stem design
    • 1
    • JH Lonner M Klotz C Levitz PA Lotke 2001 Changes in bone density after cemented total knee arthroplasty. Influence of stem design J Arthroplasty 16 1 107 111
    • (2001) J Arthroplasty , vol.16 , pp. 107-111
    • Lonner, J.H.1    Klotz, M.2    Levitz, C.3    Lotke, P.A.4
  • 24
  • 25
    • 0028566201 scopus 로고
    • Cemented long-stem revision total knee arthroplasty
    • PB Murray JA Rand AD Hanssen 1994 Cemented long-stem revision total knee arthroplasty Clin Orthop 309 116 123
    • (1994) Clin Orthop , vol.309 , pp. 116-123
    • Murray, P.B.1    Rand, J.A.2    Hanssen, A.D.3
  • 27
    • 0023026366 scopus 로고
    • Osteoarthritis
    • JG Peyron 1986 Osteoarthritis Clin Orthop 213 13 19
    • (1986) Clin Orthop , vol.213 , pp. 13-19
    • Peyron, J.G.1
  • 28
    • 0020052795 scopus 로고
    • Effects of tibial components on load transfer in the upper tibia
    • D Reilly PS Walker M Ben-Dov FC Ewald 1982 Effects of tibial components on load transfer in the upper tibia Clin Orthop 165 273 282
    • (1982) Clin Orthop , vol.165 , pp. 273-282
    • Reilly, D.1    Walker, P.S.2    Ben-Dov, M.3    Ewald, F.C.4
  • 29
    • 0023511631 scopus 로고
    • The history of some fundamental concepts in bone biomechanics
    • 11/12
    • H Roesler 1987 The history of some fundamental concepts in bone biomechanics J Biomech 20 11/12 1025 1034
    • (1987) J Biomech , vol.20 , pp. 1025-1034
    • Roesler, H.1
  • 30
    • 0025075842 scopus 로고
    • Total knee replacement after fractures about the knee
    • RP Roffi PO Merritt 1990 Total knee replacement after fractures about the knee Orthop Rev 19 614 620
    • (1990) Orthop Rev , vol.19 , pp. 614-620
    • Roffi, R.P.1    Merritt, P.O.2
  • 31
    • 0035014499 scopus 로고    scopus 로고
    • Osteoporosis with low dose corticosteroids. Contribution of underlying disease effects and discriminatory ability of ultrasound versus bone densitometry
    • 5
    • P Sambrook A Raj D Hunter V Naganathan R Mason B Robinson 2001 Osteoporosis with low dose corticosteroids. Contribution of underlying disease effects and discriminatory ability of ultrasound versus bone densitometry J Rheumatol 28 5 1063 1067
    • (2001) J Rheumatol , vol.28 , pp. 1063-1067
    • Sambrook, P.1    Raj, A.2    Hunter, D.3    Naganathan, V.4    Mason, R.5    Robinson, B.6
  • 32
    • 0032729167 scopus 로고    scopus 로고
    • Non-union of tibial stress fractures in patients with deformed arthritic knees
    • 4
    • MR Sawant SP Bendall TG Kavanagh ND Citron 1999 Non-union of tibial stress fractures in patients with deformed arthritic knees J Bone Joint Surg Br 81 4 663 666
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 663-666
    • Sawant, M.R.1    Bendall, S.P.2    Kavanagh, T.G.3    Citron, N.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.