메뉴 건너뛰기




Volumn 79, Issue 4, 1997, Pages 675-679

Periprosthetic bone remodelling after cementless total hip replacement. A prospective comparison of two different implant designs

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; BONE DENSITY; BONE MINERAL; BONE REMODELING; CLINICAL ARTICLE; CONFERENCE PAPER; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; HUMAN; MALE; PRIORITY JOURNAL; PROSTHESIS FIXATION; RIGIDITY; TIME; TOTAL HIP PROSTHESIS;

EID: 0030787629     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.79B4.7410     Document Type: Conference Paper
Times cited : (85)

References (14)
  • 1
    • 0029021451 scopus 로고
    • Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty
    • Cohen B, Rushton N. Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty. J Bone Joint Surg [Br] 1995;77-B:479-83.
    • (1995) J Bone Joint Surg [Br] , vol.77 B , pp. 479-483
    • Cohen, B.1    Rushton, N.2
  • 2
    • 0026795145 scopus 로고
    • A quantitative evaluation of periprosthetic bone-remodelling after cementless total hip athroplasty
    • Engh CA, McGovern TF, Bobyn JD, Harris WH. A quantitative evaluation of periprosthetic bone-remodelling after cementless total hip athroplasty. J Bone Joint Surg [Am] 1992;74-A: 1009-20.
    • (1992) J Bone Joint Surg [Am] , vol.74 A , pp. 1009-1020
    • Engh, C.A.1    McGovern, T.F.2    Bobyn, J.D.3    Harris, W.H.4
  • 3
    • 0026464523 scopus 로고
    • Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty
    • Kiratli BJ, Heiner JP, McBeath AA, Wilson MA. Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty. J Orthop Res 1992;10:836-44.
    • (1992) J Orthop Res , vol.10 , pp. 836-844
    • Kiratli, B.J.1    Heiner, J.P.2    McBeath, A.A.3    Wilson, M.A.4
  • 4
    • 0025884653 scopus 로고
    • Quantifying bone loss from the proximal femur after total hip arthroplasty
    • McCarthy CK, Steinberg GG, Agren M, et al. Quantifying bone loss from the proximal femur after total hip arthroplasty. J Bone Joint Surg [Br] 1991;73-B:774-8.
    • (1991) J Bone Joint Surg [Br] , vol.73 B , pp. 774-778
    • McCarthy, C.K.1    Steinberg, G.G.2    Agren, M.3
  • 5
    • 0029134888 scopus 로고
    • Bone remodelling in the proximal femur after Charnley total hip arthroplasty
    • Cohen B, Rushton N. Bone remodelling in the proximal femur after Charnley total hip arthroplasty. J Bone Joint Surg [Br] 1995;77-B:815-9.
    • (1995) J Bone Joint Surg [Br] , vol.77 B , pp. 815-819
    • Cohen, B.1    Rushton, N.2
  • 6
    • 0027409719 scopus 로고
    • Dual-energy x-ray absorptiometry measurement of bone mineral density around porouscoated cementless femoral implants
    • Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW. Dual-energy x-ray absorptiometry measurement of bone mineral density around porouscoated cementless femoral implants. J Bone Joint Surg [Br] 1993;75-B:279-87.
    • (1993) J Bone Joint Surg [Br] , vol.75 B , pp. 279-287
    • Kilgus, D.J.1    Shimaoka, E.E.2    Tipton, J.S.3    Eberle, R.W.4
  • 7
    • 0028944925 scopus 로고
    • Atrophy of the proximal part of the femur after total hip arthroplasty without cement: A qualitative comparison of cobalt-chromium and titanium femoral stems with use of dual X-ray absorptiometry
    • Hughes SS, Furia JP, Smith P, Pellegrini VD Jr. Atrophy of the proximal part of the femur after total hip arthroplasty without cement: a qualitative comparison of cobalt-chromium and titanium femoral stems with use of dual X-ray absorptiometry. J Bone Joint Surg [Am] 1995;77-A:231-9.
    • (1995) J Bone Joint Surg [Am] , vol.77 A , pp. 231-239
    • Hughes, S.S.1    Furia, J.P.2    Smith, P.3    Pellegrini Jr., V.D.4
  • 8
    • 0026519501 scopus 로고
    • Producing and avoiding stress shielding: Laboratory and clinical observations of non-cemented total hip arthroplasty
    • Bobyn JD, Mortimer ES, Glassman AH, et al. Producing and avoiding stress shielding: laboratory and clinical observations of non-cemented total hip arthroplasty. Clin Orthop 1992;274:79-96.
    • (1992) Clin Orthop , vol.274 , pp. 79-96
    • Bobyn, J.D.1    Mortimer, E.S.2    Glassman, A.H.3
  • 9
    • 0026560894 scopus 로고
    • Determinants of stress shielding: Design versus materials versus interface
    • Sumner DR, Galante JO. Determinants of stress shielding: design versus materials versus interface. Clin Orthop 1992;274:202-12.
    • (1992) Clin Orthop , vol.274 , pp. 202-212
    • Sumner, D.R.1    Galante, J.O.2
  • 10
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes R, Weinans H, van Rietbergen B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop 1992;274:124-34.
    • (1992) Clin Orthop , vol.274 , pp. 124-134
    • Huiskes, R.1    Weinans, H.2    Van Rietbergen, B.3
  • 11
    • 0022454624 scopus 로고
    • The isoelastic, noncemented total hip arthroplasty: Preliminary experience with 400 cases
    • Andrew TA, Flanagan JP, Gerundini M, Bombelli R. The isoelastic, noncemented total hip arthroplasty: preliminary experience with 400 cases. Clin Orthop 1986;206:128-38.
    • (1986) Clin Orthop , vol.206 , pp. 128-138
    • Andrew, T.A.1    Flanagan, J.P.2    Gerundini, M.3    Bombelli, R.4
  • 12
    • 0348225578 scopus 로고
    • Primary isoelastic total hip arthroplasty
    • Horne JG. Primary isoelastic total hip arthroplasty. J Bone Joint Surg [Br] 1991;73-B:Suppl I:19.
    • (1991) J Bone Joint Surg [Br] , vol.73 B , Issue.1 SUPPL. , pp. 19
    • Horne, J.G.1
  • 13
    • 0011674667 scopus 로고    scopus 로고
    • Spotorno-Morscher cementless hip arthroplasty: The medium-term results in patients 60 years and under
    • Ellis SC, Servant CTJ, Morrison PJM, Ross AC. Spotorno-Morscher cementless hip arthroplasty: the medium-term results in patients 60 years and under. J Bone Joint Surg [Br] 1997;79-B:Suppl I:95.
    • (1997) J Bone Joint Surg [Br] , vol.79 B , Issue.1 SUPPL. , pp. 95
    • Ellis, S.C.1    Servant, C.T.J.2    Morrison, P.J.M.3    Ross, A.C.4
  • 14
    • 0028863493 scopus 로고
    • Effect of femoral rotation on bone mineral density measurements with dual energy X-ray absorptiometry
    • Goh JC, Low SL, Bose K. Effect of femoral rotation on bone mineral density measurements with dual energy X-ray absorptiometry. Calcif Tissue Int 1995;57:340-3.
    • (1995) Calcif Tissue Int , vol.57 , pp. 340-343
    • Goh, J.C.1    Low, S.L.2    Bose, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.