메뉴 건너뛰기




Volumn 19, Issue 11, 2008, Pages

Accurate dew-point measurement over a wide temperature range using a quartz crystal microbalance dew-point sensor

Author keywords

Quartz crystal microbalance dew point sensor; Supercooled dew

Indexed keywords

NATURAL FREQUENCIES; QUARTZ; SUPERCOOLING;

EID: 58149280586     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/19/11/115206     Document Type: Article
Times cited : (33)

References (30)
  • 1
    • 0022813956 scopus 로고
    • Humidity sensors: Principles and applications
    • Yamazoe N and Shimizu Y 1986 Humidity sensors: principles and applications Sensors Actuators 10 379-98
    • (1986) Sensors Actuators , vol.10 , Issue.3-4 , pp. 379-398
    • Yamazoe, N.1    Shimizu, Y.2
  • 2
    • 0032396624 scopus 로고    scopus 로고
    • Determination of water vapor and aerosol densities in the tropospheric atmosphere from nitrogen and water vapor Raman signals
    • Kim D H, Cha H K, Lee J M, Yeon K H and Choi S Ch 1998 Determination of water vapor and aerosol densities in the tropospheric atmosphere from nitrogen and water vapor Raman signals J. Korean Phys. Soc. 33 301-7
    • (1998) J. Korean Phys. Soc. , vol.33 , Issue.3 , pp. 301-307
    • Kim, D.H.1    Cha, H.K.2    Lee, J.M.3    Yeon, K.H.4    Ch, C.S.5
  • 3
    • 0030234081 scopus 로고    scopus 로고
    • Humidity sensors based on polymer thin films
    • Sakai Y, Sadaoka Y and Matsuguchi M 1996 Humidity sensors based on polymer thin films Sensors Actuators B 35 85-90
    • (1996) Sensors Actuators , vol.35 , Issue.1-3 , pp. 85-90
    • Sakai, Y.1    Sadaoka, Y.2    Matsuguchi, M.3
  • 4
    • 58149325887 scopus 로고
    • Ceramic sensors for humidity detection: The state-of-the-art and future developments
    • Traversa E 1995 Ceramic sensors for humidity detection: the state-of-the-art and future developments Sensors Actuators B 23 135-56
    • (1995) Sensors Actuators , vol.23 , Issue.2-3 , pp. 135-156
    • Traversa, E.1
  • 5
    • 0037186194 scopus 로고    scopus 로고
    • Recent achievements in miniaturized humidity sensors-a review of transduction techniques
    • Rittersma Z M 2002 Recent achievements in miniaturized humidity sensors-a review of transduction techniques Sensors Actuators A 96 196-210
    • (2002) Sensors Actuators , vol.96 , Issue.2-3 , pp. 196-210
    • Rittersma, Z.M.1
  • 6
    • 33645959877 scopus 로고    scopus 로고
    • Humidity sensitive properties of ZnO nanotetrapods investigated by a quartz crystal microbalance
    • Wang X H, Ding Y F, Zhang J, Zhu Z Q, You S Z, Chen S Q and Zhu J 2006 Humidity sensitive properties of ZnO nanotetrapods investigated by a quartz crystal microbalance Sensors Actuators B 115 421-7
    • (2006) Sensors Actuators , vol.115 , Issue.1 , pp. 421-427
    • Wang, X.H.1    Ding, Y.F.2    Zhang, J.3    Zhu, Z.Q.4    You, S.Z.5    Chen, S.Q.6    Zhu, J.7
  • 7
    • 17444413719 scopus 로고    scopus 로고
    • Quartz crystal microbalance coated with carbon nanotube films used as humidity sensor
    • Zhang Y, Yu K, Jiang D, Luo L and Zhu Z 2005 Quartz crystal microbalance coated with carbon nanotube films used as humidity sensor Sensors Actuators A 120 142-6
    • (2005) Sensors Actuators , vol.120 , Issue.1 , pp. 142-146
    • Zhang, Y.1    Yu, K.2    Jiang, D.3    Luo, L.4    Zhu, Z.5
  • 8
    • 16644381479 scopus 로고    scopus 로고
    • 3 thick film template as sensitive capacity trace moisture sensor
    • 3 thick film template as sensitive capacity trace moisture sensor Sensors Actuators B 106 258-62
    • (2005) Sensors Actuators , vol.106 , Issue.1 , pp. 258-262
    • Mistry, K.K.1    Saha, D.2    Sengupta, K.3
  • 9
    • 0033706330 scopus 로고    scopus 로고
    • Some investigation results of the instability of humidity sensors based on alumina and porous silicon materials
    • Mai L H, Hoa P T M, Binh N T B, Ha N T T and An D K 2000 Some investigation results of the instability of humidity sensors based on alumina and porous silicon materials Sensors Actuators B 66 63-5
    • (2000) Sensors Actuators , vol.66 , Issue.1-3 , pp. 63-65
    • Mai, L.H.1    Hoa, P.T.M.2    Binh, N.T.B.3    Ha, N.T.T.4    An, D.K.5
  • 10
    • 14744305132 scopus 로고    scopus 로고
    • Polymeric humidity sensor using polyelectrolytes derived from alkoxysilane cross-linker
    • Lee C W, Joo S W and Gong M S 2005 Polymeric humidity sensor using polyelectrolytes derived from alkoxysilane cross-linker Sensors Actuators B 105 150-8
    • (2005) Sensors Actuators , vol.105 , Issue.2 , pp. 150-158
    • Lee, C.W.1    Joo, S.W.2    Gong, M.S.3
  • 11
    • 0036682861 scopus 로고    scopus 로고
    • Humidity sensitive properties of substituted polyacetylenes
    • Li Y and Yang M 2002 Humidity sensitive properties of substituted polyacetylenes Synth. Met. 129 285-90
    • (2002) Synth. Met. , vol.129 , Issue.3 , pp. 285-290
    • Li, Y.1    Yang, M.2
  • 12
  • 13
    • 0037741187 scopus 로고    scopus 로고
    • A plastic optical fibre sensor for real-time humidity monitoring
    • Muto S, Suzuki O, Amano T and Morisawa M 2003 A plastic optical fibre sensor for real-time humidity monitoring Meas. Sci. Technol. 14 746-50
    • (2003) Meas. Sci. Technol. , vol.14 , Issue.6 , pp. 746-750
    • Muto, S.1    Suzuki, O.2    Amano, T.3    Morisawa, M.4
  • 14
    • 84951279351 scopus 로고
    • Verwendung von schwingquarzen zur wagung dunner schechten and zur mikrowagung
    • Sauerbrey G 1959 Verwendung von schwingquarzen zur wagung dunner schechten and zur mikrowagung Z. Phys. 155 206-22
    • (1959) Z. Phys. , vol.155 , Issue.2 , pp. 206-222
    • Sauerbrey, G.1
  • 15
    • 0034275864 scopus 로고    scopus 로고
    • Quartz crystal microbalance (QCM) used as humidity sensor
    • Pascal-Delannoy F, Sorli B and Boyer A 2000 Quartz crystal microbalance (QCM) used as humidity sensor Sensors Actuators 84 285-91
    • (2000) Sensors Actuators , vol.84 , Issue.3 , pp. 285-291
    • Pascal-Delannoy, F.1    Sorli, B.2    Boyer, A.3
  • 16
    • 79956009706 scopus 로고    scopus 로고
    • Sensitivity of a platinum-polyyne-based sensor to low relative humidity and chemical vapors
    • Caliendo C, Fratoddi I and Russo M V 2002 Sensitivity of a platinum-polyyne-based sensor to low relative humidity and chemical vapors Appl. Phys. Lett. 80 4849-51
    • (2002) Appl. Phys. Lett. , vol.80 , Issue.25 , pp. 4849-4851
    • Caliendo, C.1    Fratoddi, I.2    Russo, M.V.3
  • 17
    • 9544222626 scopus 로고    scopus 로고
    • The application of CNT/Nafion composite material to low humidity sensing measurement
    • Chen H W, Wu R J, Chan K H, Sun Y L and Su P G 2005 The application of CNT/Nafion composite material to low humidity sensing measurement Sensors Actuators B 104 80-4
    • (2005) Sensors Actuators , vol.104 , Issue.1 , pp. 80-84
    • Chen, H.W.1    Wu, R.J.2    Chan, K.H.3    Sun, Y.L.4    Su, P.G.5
  • 18
    • 32044453132 scopus 로고    scopus 로고
    • A highly stable quartz crystal microbalance sensor and its application to water vapor measurements
    • Kwon S Y, Choi B I, Kim J C and Nham H S 2006 A highly stable quartz crystal microbalance sensor and its application to water vapor measurements J. Korean Phys. Soc. 48 161-5
    • (2006) J. Korean Phys. Soc. , vol.48 , pp. 161-165
    • Kwon, S.Y.1    Choi, B.I.2    Kim, J.C.3    Nham, H.S.4
  • 20
    • 38549120731 scopus 로고    scopus 로고
    • Recognition of supercooled dew in a quartz crystal microbalance dew-point sensor by slip phenomena
    • Kwon S Y, Kim J C and Choi B I 2007 Recognition of supercooled dew in a quartz crystal microbalance dew-point sensor by slip phenomena Metrologia 44 L37-40
    • (2007) Metrologia , vol.44 , Issue.5
    • Kwon, S.Y.1    Kim, J.C.2    Choi, B.I.3
  • 21
    • 79956037412 scopus 로고    scopus 로고
    • Compensation of temperature effects in quartz crystal microbalance measurements
    • Rahtu A and Ritala M 2002 Compensation of temperature effects in quartz crystal microbalance measurements Appl. Phys. Lett. 80 521-3
    • (2002) Appl. Phys. Lett. , vol.80 , Issue.3 , pp. 521-523
    • Rahtu, A.1    Ritala, M.2
  • 22
    • 0029344270 scopus 로고
    • Development and testing of a high temperature quartz crystal microbalance
    • Mecea V M, Carlsson J O, Heszler P and Bartan M 1995 Development and testing of a high temperature quartz crystal microbalance Vacuum 46 691-4
    • (1995) Vacuum , vol.46 , Issue.7 , pp. 691-694
    • Mecea, V.M.1    Carlsson, J.O.2    Heszler, P.3    Bartan, M.4
  • 26
    • 0000192865 scopus 로고
    • Important new values of the physical constants of 1986, vapour pressure formulations based on ITS-90, and psychrometric formulae
    • Sonntag D 1990 Important new values of the physical constants of 1986, vapour pressure formulations based on ITS-90, and psychrometric formulae Z. Meteorol. 40 340-4
    • (1990) Z. Meteorol. , vol.40 , Issue.5 , pp. 340-344
    • Sonntag, D.1
  • 28
    • 0348171978 scopus 로고    scopus 로고
    • The measurement of tiny dew droplets at the initial deposition stage and dew point using a phase-shift interference microscope
    • Matsumoto S 2003 The measurement of tiny dew droplets at the initial deposition stage and dew point using a phase-shift interference microscope Meas. Sci. Technol. 14 2075-80
    • (2003) Meas. Sci. Technol. , vol.14 , Issue.12 , pp. 2075-2080
    • Matsumoto, S.1
  • 29
    • 33751071395 scopus 로고    scopus 로고
    • Fast dew point hygrometer with silicon integrated detector-optimization of dynamic properties
    • Weremczuk J, Tarapata G, Paczesny D and Jachowicz R 2006 Fast dew point hygrometer with silicon integrated detector-optimization of dynamic properties Sensors Actuators A 132 195-8
    • (2006) Sensors Actuators , vol.132 , Issue.1 , pp. 195-198
    • Weremczuk, J.1    Tarapata, G.2    Paczesny, D.3    Jachowicz, R.4
  • 30
    • 33645965549 scopus 로고    scopus 로고
    • Evanescently coupled dewpoint sensor based on a silicon waveguide
    • Stoddart P R, Pearce J B and Mazzolini A P 2006 Evanescently coupled dewpoint sensor based on a silicon waveguide Sensors Actuators A 128 225-9
    • (2006) Sensors Actuators , vol.128 , Issue.2 , pp. 225-229
    • Stoddart, P.R.1    Pearce, J.B.2    Mazzolini, A.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.